• Title/Summary/Keyword: Amplitude compression

Search Result 93, Processing Time 0.025 seconds

Determination of the dispersion profile of a dispersion decreasing fiber and the input pulse amplitude for efficient adiabatic pulse compression (효과적인 단열 펄스 압축을 위한 분산감소 광섬유의 분산 특성 및 입력 펄스 진폭 결정)

  • 최봉수;서동선
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.3
    • /
    • pp.123-130
    • /
    • 1997
  • We determine the dispersion profile of a dispersion decreasing fiber(DDF) for optimum pulse compression from a trade-off between high pulse compression and low pedestal power/short DDF length. We find that the optimum vlaue of the exponential dispersion decreasing factor .alpha. is 0.95 and that the corresponding optimum fiber length is 1.5 times of the initial soliton period. Passing through the dDF, ~10 times of pulse comparession ratio can be achieved without significant increase in pedestal power. To compress relatively broad pulses using a given DDF optimized at a specific pulse width, we also detemrine the optimum input pulse amplitude, as a function of input pulse width.

  • PDF

Characteristics the Pressure Variations according to the Exhaust Pipe of 4-Stroke Single Engine (4행정 단기통 엔진의 배기관에 따른 압력 변동 특성)

  • Lee, Hyo-Deok;Choi, Seok-Cheun;Lee, Sang-Chul;Lee, Kwang-Young;Jeong, Hyo-Min;Chung, Han-Shik
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1666-1671
    • /
    • 2004
  • In this study, a experimental method has been introduced for the various exhaust pipe geometry of 4-stroke single engine. The main experimental parameters are the variation of exhaust pipe diameters and lengths, to measuring the pulsating flow when the intake and exhaust valves are working, As the results of experimental test, the various exhaust geometry were influenced strongly on the exhaust pressure. As the exhaust pipe diameter was decreased, the amplitude and the number of compression wave in exhaust pressure was increased. According to decreasing pipe diameter, the number of compression wave in exhaust pressure was decreased. When the pipe diameter was increase, the second amplitude was increased.

  • PDF

Computational and Experimental Analysis of Variable Exhaust Pipe Diameters in Four-Stroke Gasoline Engine (4 행정 가솔린 엔진 내의 다양한 배기 파이프 직경 변화에 따른 실험과 수치해석)

  • Choi, Seuk-Cheun;Lee, Hae-Jeong;Shin, You-Sik;Chung, Han-Shik;Jeong, Hyo-Min;Lee, Kwang-Young
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.684-689
    • /
    • 2004
  • In this study, a experimental method has been introduced for the various exhaust pipe geometry of 4-stroke single cylinder engine. The main experimental parameters are the variation of exhaust pipe diameters and lengths, to measuring the pulsating flow when the intake and exhaust valves are working. As the results of experimental test, the various exhaust geometry were influenced strongly on the exhaust pressure. As the exhaust pipe diameter was decreased, the amplitude and the number of compression wave in exhaust pressure was increased. According to decreasing pipe diameter, the number of compression wave in exhaust pressure was decreased. When the pipe diameter was increase, the second amplitude was increased.

  • PDF

Development of Ultrasonic Pulse Compression Using Golay Codes (Golay 코드를 사용한 초음파펄스압축법 개발)

  • Kim, Young-H.;Kim, Young-Gil;Jeong, Peter
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.3
    • /
    • pp.185-193
    • /
    • 1994
  • Conventional ultrasonic flaw detection system uses a large amplitude narrow pulse to excite a transducer. However, these systems are limited in pulse energy. An excessively large amplitude causes a dielectric breakage of the transducer, and an excessively long pulse causes decrease of the resolution. Using the pulse compression, a long pulse of pseudorandom signal can be used without sacrificing resolution by signal correlation. In the present work, the pulse compression technique was implemented into an ultrasonic system. Golay code was used as a pseudorandom signal in this system, since pair sum of autocorrelations has no sidelobe. The equivalent input pulse of the Golay code was derived to analyze the pulse compression system. Throughout the experiment, the pulse compression technique has demonstrated for its improved SNR(signal to noise ratio) by reducing the system's white noise. And the experimental data also indicated that the SNR enhancement was propotional to the square root of the code length used. The technique seems to perform particularly well with highly energy-absorbent materials such as polymers, plastics and rubbers.

  • PDF

Performance Evaluation of ECG Compression Algorithms using Classification of Signals based PQSRT Wave Features (PQRST파 특징 기반 신호의 분류를 이용한 심전도 압축 알고리즘 성능 평가)

  • Koo, Jung-Joo;Choi, Goang-Seog
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.4C
    • /
    • pp.313-320
    • /
    • 2012
  • An ECG(Electrocardiogram) compression can increase the processing speed of system as well as reduce amount of signal transmission and data storage of long-term records. Whereas conventional performance evaluations of loss or lossless compression algorithms measure PRD(Percent RMS Difference) and CR(Compression Ratio) in the viewpoint of engineers, this paper focused on the performance evaluations of compression algorithms in the viewpoint of diagnostician who diagnosis ECG. Generally, for not effecting the diagnosis in the ECG compression, the position, length, amplitude and waveform of the restored signal of PQRST wave should not be damaged. AZTEC, a typical ECG compression algorithm, is validated its effectiveness in conventional performance evaluation. In this paper, we propose novel performance evaluation of AZTEC in the viewpoint of diagnostician.

AN EXPERIMENTAL STUDY OF ELECTROPHYSIOLOGICAL AND HISTOLOGICAL ASSESSMENT ON THE INJURY TYPES IN RABBIT INFERIOR ALVEOLAR NERVE (가토의 하치조 신경 손상 형태에 따른 전기생리학적 및 조직학적 변화에 관한 실험적 연구)

  • Lee, Jae-Eun;Lee, Dong-Keun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.18 no.4
    • /
    • pp.679-700
    • /
    • 1996
  • Inferior alveolar nerve dysfunction may be the result of trauma, disease, or iatrogenic injury. Inferior alveolar nerve injury is inherent risk in endodontic therapy, orthognathic surgery of the mandible, and extraction of mandibular teeth, particularly the third molars. The sensory disturbances of inferior alveolar nerve associated with such injury have been well documented clinical problem that is commonly evaluated by several clinical sensory test including Tinels sign, Von Frey test(static light touch detection), directional discrimination, two-point discrimination, pin pressure nociceptive discrimination, and thermal test. These methods used to detect and assess inferior alveolar nerve injury have been subjective in nature, relying on the cooperation of the patients. In addition, many of these techniques are sensitive to differences in the examiners experience and skill with the particular technique. Data obtained at different times or by different examiners are therefore difficult to compare. Prior experimental studies have used electro diagnostic methods(sensory evoked potential) to objectively evaluate inferior alveolar nerve after nerve injury. This study was designed with inferior alveolar nerve of rabbit. Several types of injury including mind, moderate, severe compression and perforation with 19 gauze, 21 gauze needle and 6mm, 10mm traction were applied for taking the sesory evoked ppterntial. Latency and amplitude of injury rabbit inferior alveolar nerve were investigated with sensory evoked potential using unpaired t-test. The results were as follows : 1. Intensity of threshold (T1) was $128{\pm}16{\mu}A$ : latency, $0.87{\pm}0.07$ microsecond : amplitude, $0.4{\pm}0.1{\mu}V$ : conduction velocity, 23.3 m/s in sensory evoked potential of uninjured rabbit inferior alveolar nerve. 2. Rabbit inferior alveolar nerve consists of type II and III sensory nerve fiber. 3. Latency was increased and amplitude was decreased in compression injury. The more injured, the more changed in latency and amplitude. 4. Findings in perforation injury was similar to compression injury. Waveform for sensory evoked potential improved by increasing postinjured time. 5. Increasing latency was prominent in traction injury rabbit inferior alveolar nerve. 6. In microscopic histopathological findings, significant degeneration and disorganization of the internal architecture were seen in nerve facicle of severe compression and 10mm traction group. From the above findings, electrophysiological assessment(sensory evoked potential) of rabbit injured inferior alveolar nerve is reliable technique in diagnosis and prognosis of nerve injury.

  • PDF

Research and Standardization Trends of Digital Hologram Compression (디지털 홀로그램 압축 기술 및 표준화 동향)

  • Oh, K.J.;Park, J.
    • Electronics and Telecommunications Trends
    • /
    • v.34 no.6
    • /
    • pp.145-155
    • /
    • 2019
  • Holography is a technique that can acquire and reproduce 3D objects nearly perfectly by representing both the amplitude and phase of light. Recently, digital holography has received considerable attention because it is simpler than analog holography from acquisition to reproduction. The data size of the digital hologram increases tremendously as the quality of digital holograms depends on their pixel pitch and resolution. Hence, efficient compression is necessary to realize holographic imaging services. In this report, we introduce recent digital hologram compression techniques and JPEG Pleno holography, which is the first international standardization activity for digital hologram compression. Furthermore, we discuss the future of this field.

Experimental research on the propagation of plastic hinge length for multi-scale reinforced concrete columns under cyclic loading

  • Tang, Zhenyun;Ma, Hua;Guo, Jun;Xie, Yongping;Li, Zhenbao
    • Earthquakes and Structures
    • /
    • v.11 no.5
    • /
    • pp.823-840
    • /
    • 2016
  • The plastic hinge lengths of beams and columns are a critical demand parameter in the nonlinear analysis of structures using the finite element method. The numerical model of a plastic hinge plays an important role in evaluating the response and damage of a structure to earthquakes or other loads causing the formation of plastic hinges. Previous research demonstrates that the plastic hinge length of reinforced concrete (RC) columns is closely related to section size, reinforcement ratio, reinforcement strength, concrete strength, axial compression ratio, and so on. However, because of the limitations of testing facilities, there is a lack of experimental data on columns with large section sizes and high axial compression ratios. In this work, we conducted a series of quasi-static tests for columns with large section sizes (up to 700 mm) and high axial compression ratios (up to 0.6) to explore the propagation of plastic hinge length during the whole loading process. The experimental results show that besides these parameters mentioned in previous work, the plastic hinge of RC columns is also affected by loading amplitude and size effect. Therefore, an approach toward considering the effect of these two parameters is discussed in this work.

Application of Biosignal Data Compression for u-Health Sensor Network System (u-헬스 센서 네트워크 시스템의 생체신호 압축 처리)

  • Lee, Yong-Gyu;Park, Ji-Ho;Yoon, Gil-Won
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.5
    • /
    • pp.352-358
    • /
    • 2012
  • A sensor network system can be an efficient tool for healthcare telemetry for multiple users due to its power efficiency. One drawback is its limited data size. This paper proposed a real-time application of data compression/decompression method in u-Health monitoring system in order to improve the network efficiency. Our high priority was given to maintain a high quality of signal reconstruction since it is important to receive undistorted waveform. Our method consisted of down sampling coding and differential Huffman coding. Down sampling was applied based on the Nyquist-Shannon sampling theorem and signal amplitude was taken into account to increase compression rate in the differential Huffman coding. Our method was successfully tested in a ZigBee and WLAN dual network. Electrocardiogram (ECG) had an average compression ratio of 3.99 : 1 with 0.24% percentage root mean square difference (PRD). Photoplethysmogram (PPG) showed an average CR of 37.99 : 1 with 0.16% PRD. Our method produced an outstanding PRD compared to other previous reports.

The combined reinforcement to recycled aggregate concrete by circular steel tube and basalt fiber

  • Zhang, Xianggang;Zhang, Songpeng;Chen, Xu;Gao, Xiang;Zhou, Chunheng
    • Computers and Concrete
    • /
    • v.29 no.5
    • /
    • pp.323-334
    • /
    • 2022
  • In order to study the axial compression performance of basalt-fiber reinforced recycled concrete (BFRRC) filled circular steel tubular short columns, the axial compression performance tests of seven short column specimens were conducted to observe the mechanical whole-process and failure mode of the specimens, the load-displacement curves and the load-strain curves of the specimens were obtained, the influence of design parameters on the axial compression performance of BFRRC filled circular steel tubular short columns was analyzed, and a practical mathematical model of stiffness degradation and a feasible stress-strain curve equation for the whole process were suggested. The results show that under the axial compression, the steel tube buckled and the core BFRRC was crushed. The load-axial deformation curves of all specimens show a longer deformation flow amplitude. Compared with the recycled coarse aggregate (RCA) replacement ratio and the basalt fiber dosage, the BFRRC strength has a great influence on the peak bearing capacity of the specimen. The RCA replacement ratio and the BFRRC strength are detrimental to ductility, whereas the basalt fiber dosage is beneficial to ductility.