• Title/Summary/Keyword: Amplatzer duct occluder

Search Result 4, Processing Time 0.022 seconds

The hybrid perventricular closure of apical muscular ventricular septal defect with Amplatzer duct occluder

  • Kim, Soo Jin;Huh, June;Song, Jin Young;Yang, Ji-Hyuk;Jun, Tae-Gook;Kang, I-Seok
    • Clinical and Experimental Pediatrics
    • /
    • v.56 no.4
    • /
    • pp.176-181
    • /
    • 2013
  • Purpose: Apical muscular ventricular septal defects (MVSDs), especially in small infants, can be difficult to manage using surgical and percutaneous closure. An intraoperative perventricular procedure is a good option for closing apical MVSDs in small children with or without associated cardiac anomalies. We evaluated the results of hybrid perventricular closure of apical MVSDs performed using an Amplatzer duct occluder (ADO). Methods: We retrospectively reviewed the medical records of 5 patients who underwent hybrid perventricular closure of MVSDs with ADOs, from March 2006 to May 2011. The median patient age at the time of the procedure was 12 months (range, 25 days to 25 months), and the median body weight was 9.1 kg (range, 4.3 to 15 kg). Two patients had multiple ventricular septal defects (VSDs; additional perimembranous VSD in 1 patient and multiple MVSDs in the other) and 3 patients had associated cardiac anomalies; complete transposition of the great arteries in 1 patient and an atrial septal defect in 2 patients. All the procedures were performed on beating hearts, exception in 1 case. The ADO selected for the aortic side was at least 1 to 2 mm larger than the largest VSD in the left ventricle side. Results: The procedure was successful in all patients and each device was well positioned. During the median follow-up of 2.4 years, a small residual VSD was noted in 2 patients who had multiple VSDs and no leakage was seen in the other 3 patients. Conclusion: Perventricular closure of MVSD with an ADO is a good option for patients with apical MVSD. However, careful manipulation is important, especially in the case of small infants.

Use of an Amplatzer Vascular Plug to occlude a tubular type of patent ductus arteriosus (원통형 모양 동맥관의 경피적 폐쇄술에서의 Amplatzer Vascular Plug 의 사용)

  • Choi, Eun-Young;Jang, So-Ick;Kim, Soo-Jin
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.9
    • /
    • pp.1035-1037
    • /
    • 2009
  • Patent ductus arteriosus (PDA) is a common congenital heart defect. All PDAs, regardless of size or degree of symptoms, require occlusion. Transcatheter PDA occlusion features fewer complications than trans-thoracic closure. It is also more cost-effective and has an excellent occlusion rate. Therefore, transcatheter PDA occlusion is accepted as the standard treatment option for PDA. However, tubular-type PDAs are difficult to close with ordinary detachable coils or the Amplatzer Duct Occluder; thus, these lesions remain a challenge for transcatheter closure. We attempted to occlude a tubular-type PDA by using an oversized Amplatzer Vascular Plug, which allowed intraluminal packing of the ductus. By using this treatment method, PDA occlusion was achieved safely with an excellent final outcome. We suggest that this approach may be a good option for transcatheter closure of a tubular-type PDA.

Clinical outcome of transcatheter closure of patent ductus arteriosus in small children weighing 10 kg or less

  • Park, Young-A;Kim, Nam-Kyun;Park, Su-Jin;Yun, Bong-Sic;Choi, Jae-Young;Sul, Jun-Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.12
    • /
    • pp.1012-1017
    • /
    • 2010
  • Purpose: Transcatheter closure has become an effective therapy in most patients with patent ductus arteriosus (PDA). However, there are difficulties in transcatheter closure of PDA in small children. We reviewed clinical outcomes of transcatheter closure of PDA in children weighing less than 10 kg in a single center. Methods: Between January 2003 and December 2009, 314 patients with PDA underwent transcatheter closure in our institute. Among them, 115 weighed less than 10 kg. All of these patients underwent transcatheter closure of PDA using either COOK Detachable $Coil^{(R)}$, PFM Nit-$Occlud^{(R)}$, or Amplatzer duct $occluder^{(R)}$. A retrospective review of the treatment results and complications was performed. Results: The mean age of patients was $9.1{\pm}5.9$ months (median, 8 months), and mean weight was $7.6{\pm}1.8kg$ (median, 7.8 kg). The mean diameter of PDA was $3.2{\pm}1.4mm$ (median, 3 mm). Complete occlusion occurred in 113 patients (98%). One patient was sent to surgery because of a failed attempt at device closure, and another patient had a small residual shunt after device placement. The average mean length of hospital stay was $3.0{\pm}3.3$ days, and mean follow-up duration was $21.0{\pm}19.6$ months. There were no major complications in any of the patients. Conclusion: Transcatheter closure of PDA is considered safe and efficacious in infants weighing less than 10 kg. With sufficient experience and further effort, transcatheter closure of PDA can be accepted as the gold standard of treatment for this group of patients.

A new strategy for transcatheter closure of patent ductus arteriosus with recent-generation devices (경피적 동맥관 폐쇄술에서 최근의 기구들의 전략적 이용과 결과)

  • Kim, Sang Yee;Lee, Soo Hyun;Kim, Nam Kyun;Choi, Jae Young;Sul, Jun Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.4
    • /
    • pp.488-493
    • /
    • 2009
  • Purpose : The aim of this study was to assess the efficacy and safety of recent-generation patent ductus arteriosus (PDA) closure devices applied by a new selection strategy according to the characteristics of each PDA. Methods : From February 2003 to January 2006, 138 patients underwent transcatheter closure of PDA (study group). According to the size and morphology of each ductus, a COOK Detachable Coil or 'flex' PFM Nit-Occlud was used for a small ductus (group 1, n=43); 'medium' PFM Nit-Occlud (group 2, n=49) for a moderate ductus; and an Amplatzer Duct Occluder (group 3, n=46) for a large ductus. The 83 patients who underwent transcatheter closure of PDA from February 2000 to January 2003 were defined as the comparison group. The Qp/Qs ratio, pulmonary/aorta pressure ratio, and MD of the ductus were compared. Immediate and follow-up results including residual shunts and complications were also evaluated and compared among groups. Results : In all 138 patients, complete occlusions were confirmed without major complications, while procedure failure (n=2, 2.2%), device embolization (n=1, 1.1%), and persistent residual shunt (n=4, 4.5%) were documented in the comparison group. Total complication rates were lower in the study group than in the comparison group (study group, 1.4%; comparison group, 9.0%; P<0.05). Conclusion : A novel strategy adopting the merits of various recent-generation devices for transcatheter closure of PDA provides excellent clinical results with minimal risk.