• Title/Summary/Keyword: Ammonium ion selective

Search Result 35, Processing Time 0.02 seconds

Ammonium Ion Binding Property of Naphtho-Crown Ethers Containing Thiazole as Sub-Cyclic Unit

  • Kim, Hong-Seok;Do, Kyung-Soon;Kim, Ki-Soo;Shim, Jun-Ho;Cha, Geun-Sig;Nam, Hak-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.10
    • /
    • pp.1465-1470
    • /
    • 2004
  • A short and efficient synthesis, solvent extraction and potentiometric measurements of new thiazole-containing naphtho-crown ethers are reported. The naphthalene moiety enhances the ammonium ion selectivity over potassium ion. The selectivity of ${NH_4}^+/K^+$ follows the trend $3\;{\approx}\;2\;>\;1$, indicating that the differences in conformational changes of 2 and 3 in forming ammonium complexes affect little on the resulting ammonium/potassium extraction selectivity ratio. The ammonium ion-selective electrodes were prepared with noctylphenyl ether plasticized poly(vinyl chloride) membranes containing 1-4 the effect of one naphthalene unit introduced on either right (2) or left (3) side of thiazolo-crown ether on their potentiometric properties (e.g., ammonium ion selectivity over other cations, response slopes, and detection limits) were not apparent. However, the ammonium ion selectivity of 1, 2 and 3 over other alkali metal and alkaline earth metal cations is 10-100 times higher than that of nonactin.

Suggestion for deep learning approach to solve the interference effect of ammonium ion on potassium ion-selective electrode

  • Kim, Min-Yeong;Heo, Jae-Yeong;Oh, Eun Hun;Lee, Joo-Yul;Lee, Kyu Hwan
    • Journal of the Korean institute of surface engineering
    • /
    • v.55 no.3
    • /
    • pp.156-163
    • /
    • 2022
  • An ammonium ion with a size and charge similar to that of potassium can bind to valinomycin, which is used as an ion carrier for potassium, and cause a meaningful interference effect on the detection of potassium ions. Currently, there are few ion sensors that correct the interference effect of ammonium ions, and there are few studies that specifically suggest the mechanism of the interference effect. By fabricating a SPCE-based potassium ion-selective electrode, the electromotive force was measured in the concentration range of potassium in the nutrient solution, and the linear range was measured to be 10-5 to 10-2 M, and the detection limit was 10-5.19 M. And the interference phenomenon of the potassium sensor was investigated in the concentration range of ammonium ions present in the nutrient solution. Therefore, a data-based analysis strategy using deep learning was presented as a method to minimize the interference effect.

Ammonium Ion Effects and Its In Situ Removal by Using Immobilized Adsorbent in Hybridoma Cell Culture (하이브리도마 세포배양에서 암모늄 이온의 영향 및 고정화 흡착제에 의한 암모늄 이온의 동시제거)

  • 정연호;이해익
    • KSBB Journal
    • /
    • v.11 no.3
    • /
    • pp.329-339
    • /
    • 1996
  • The effects of ammonium ion on cell growth kinetics, monoclonal antibody productivity, and cell metabolism of hybridoma cells were investigated. The mouse-mouse hybridoma cell line VlIIH-8 producing mouse IgG2a was used as a model system. Ammonium ion showed an inhibitory effect on cell growth and monoclonal antibody production. New immobilized adsorbents were developed for the reduction of the inhibitory effect of ammonium ion. The ammonium ion selective zeolite, Phillipsite-Gismondine was entrapped in calcium alginate bead or in dialysis membrane and applied to the hybridoma cell culture system for the in situ removal of ammonium ion from culture media. The effects of ammonium the both serum supplemented and serum free media on the cell growth were studied by applying immobilized adsorbents of calcium alginate bead type. The results demonstrated a substantial enhancement in cell growth. Applying immobilized adsorbents of dialysis membrane type to serum supplemented media also resulted in the stimulation of cell growth, cell viability and monoclonal antibody production.

  • PDF

Effects of Particle Size and Temperature on the Ammonium Ion Exchange by Natural Zeolite (천연제올라이트의 암모늄이온교환에 미치는 입자 크기 및 온도영향에 관한 연구)

  • Song, Chang Soo;Kim, Hee Jun;Chung, Tai Hak
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.3
    • /
    • pp.75-80
    • /
    • 1998
  • Ammonium ion is notorious for the adverse effects upon many of the important uses of water such as toxcity to fish, corrosion of metals and concrete, and concern over man's consumption. A clinoptilolite, which is a naturally occurring zeolite selective for ammonium ion exchange, has been used. Batch isotherm experiments were conducted for measuring ammonium ion exchange capacity. The ion exchange capacity was well described either by the Langmuir equation or by the Freundlich equation. As the particle size of the clinoptilolite decreased, exchange capacity was increased. The smaller particle size enhaced the exchange of ammonium ion due to the greater surface area and decreased diffusion to the exchange sites within the zeolite. Ammonium ion exchange capacity tended to decrease when the temperature increased from $20^{\circ}C$ to $35^{\circ}C$, and the temperature correction factor was found to be 0.98 in the Langmuir equation.

  • PDF

Performance of Self-Manufactured Ion Selective Microelectrode (ISME) for Continuous Monitoring of Ammonia and Nitrate Ions

  • Byun, Im-Gyu
    • Journal of Environmental Science International
    • /
    • v.21 no.12
    • /
    • pp.1449-1454
    • /
    • 2012
  • The ion selective microelectrodes (ISME) have been applied to observe the continuous profiles of NO3-N and NH4-N in bulk solutions or biofilms. In order to evaluate the performance and applicability of ion concentration measuring system, the characteristics, such as slope of calibration curve, detection limit and potentiometric selectivity coefficient were investigated. The slopes of calibration curve showed high degree of correspondence for each target ion concentrations. And the detection limits of nitrate and ammonia ion selective microelectrode were 10-4.7 M and 10-4.4 M, respectively. These ion selective microelectrodes were proved that their own performance could be maintained for 16 days after making. NO3-N and NH4-N selective microelectrodes were also adapted to detect the continuous ion profiles of cilia media packed MLE (Modified Ludzack-Ettinger) process. And the monitored nitrate and ammonia ion profiles with the ion selective microelectrode were stable and well corresponded to the results with conventional ion chromatograph. However, the electric potential was unstable until 8 hr because of the unknown noise. The tip shape and performance of the ion selective microelectrode was stably kept over 2 days continuous monitoring.

Comparative Studies on Ammonium Ion Selective Electrodes Using Poly(Vinyl Chloride) and Polyurethane as Substrate Matrix Materials (Poly(Vinyl Chloride)와 Polyurethane을 지지체로 사용한 암모늄이온 선택성 전극의 특성비교)

  • Cho Chang-Ae;Park Su-Moon
    • Journal of the Korean Electrochemical Society
    • /
    • v.7 no.3
    • /
    • pp.148-154
    • /
    • 2004
  • Ammonium ion selective electrodes have been prepared using nonactin as an ionophore and poly(vinyl chloride) (PVC) or polyurethane(PU) as a polymer matrix with or without a plasticizer, bis(2-ethylhexyl) adipate, and their performances have been evaluated. The reults indicate that PU-based electrodes can be designed to perform better although PVC-based electrodes generally show better performances. In efforts to explain the obervation, we also carried out atomic force microscopy as well as impedance studies, and the results suggests that islands of ion-ophores are formed in the PVC membranes through which ion transfers appear to be more facile than through the PU membranes. The PU membranes appear to have ionophores better dispersed throughout the film and are more resistive to ion mobilities in comparison to PVC films.

The Polymer Membrane Electrode by Surfactants for Measuring Continuously Thiocyanate Ion in Wastewater (폐수중 티오시안산이온을 측정하기 위한 계면활성제를 이용한 고분자 막전극)

  • 최종석;안형환;강안수;우인성;황명환
    • Journal of the Korean Society of Safety
    • /
    • v.6 no.4
    • /
    • pp.13-20
    • /
    • 1991
  • Ion-selective electrode responsive to the thiocynate ion prepared by using the quaternary ammonium salts as a active material and PVC as a membrane matrix. The effect of chemical structure and composition of active material, and the membrane thickness on the linear response. the detection limit, and Nernstian slope of the electrode studied. Under the above optimum conditions of membrane, the effect of pH and the selectivity coefficients to various interfering anions were compared and investigated. It was concluded that the functions of thiocynate ion-selective electrode(ISE) were closely related to the chemical structure of the quaternary ammonium salts. The linear response, and the detection limit of the electrode potential increased with the increase of the carbon chain length of the alkyl group in the quaternary ammonium salts in the ascending order of Aliquat 336T, TOAT, TDAT, and TDDAT. The optimum membrane thickness was 0.3mm. The electrode characteristics was better with the decrease of the concentration of active material, and the best concentration was 3 weight percent. The membrane potential was independent of the pH variation in the region from pH 2 to 12. The order of the selectivity coefficients is as follows:Cl $O_4$$^{[-10]}$$I^{[-10]}$ >N $O_3$$^{[-10]}$ >B $r^{[-10]}$$F^{[-10]}$ >C $l^{[-10]}$ >O $A_{c}$ $^{[-10]}$ 〓S $O_4$$^{2-}$.

  • PDF

Application of a. Strip Ion-Selective Electrode Sensor for Hydroponic Nutrient Solution Analysis - NO3 Analysis - (양액의 영양분 분석을 위한 Strip형 이온선택성전극 센서 의 응용 -NO3 이온 분석 -)

  • 김기영
    • Journal of Biosystems Engineering
    • /
    • v.28 no.4
    • /
    • pp.335-342
    • /
    • 2003
  • A simple disposable thick-film potentiometric strip has been developed and evaluated for hydroponics application. The strip consisted of low ion-selective electrodes (ISE) fabricated by screen-printing technology. The electrochemical responses of ion sensors for nitrate, ammonium, potassium, and magnesium were measured with specially designed 16-channel low voltage signal transducers. The analytical characteristics of the sensors were comparable with those of conventional ISE sensors. The thick-film sensors exhibit linear relationships over five concentration decades. The concentration of N $O_3$ - ion in standard solution can be determined by direct potentiometric measurements without any conditioning before measurements. However, measurement of $K^{+}$, N $H_4$$^{+}$, and $Mg^{2+}$ ionic concentrations in nutrient solutions seems not feasible.

Pilymeric Membrane Sodium Ion-Selective Electrodes Based on Calix[4}arene Triesters

  • Kim, Yun Deok;Jeong, Hae Sang;Gang, Seong Ok;Nam, Gye Cheon;Jeon, Seung Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.4
    • /
    • pp.405-408
    • /
    • 2001
  • New lipophilic triesters of calix[4]arene and calix[4]quinone are investigated as sodium ion-selective ionophores in poly(vinyl chloride) membrane electrodes. For an ion selective electrode based on calix[4]arene triester I, the linear response is 1 ${\times}$10-3.5 to 1 ${\times}$ 10-1 M of Na+ concentrations. The selectivity coefficients for sodium ion over alkali metal and ammonium ions are determined. The detection limit (logaNa+ = -4.50) and the selectivity coefficient (logKNa+,K+pot = -1.86) are obtained for polymeric membrane electrode containing calix[4]arene triester I.

Development of High Density Mammalian CellCulture system for the Production of Tissue-Type Plasminogen Activator

  • Park, Byong-Gon;Chun, Joo-Mi;Lee, Chang-Jin;Chun, Gie-Taek;Kim, Ik-Hwan;Jeong, Yeon-Ho
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.5 no.2
    • /
    • pp.123-129
    • /
    • 2000
  • A high cell density culture system for the anchorage dependent CHO cells was developed based on the combination of in removal of ammonium ion and microcarrier culture system, and semi-fed-batch feeding of glucose and glutamine was employed to the developed culture system. The glass bead was selected as an optimum microcarrier in terms of cell growth. An ammonium ion selective zeolite, Phillipsite-Gismondine, was packed in a dialysis menium ion. The semi-fed-batch operation was employer to the novel culture system for the high density cell culture, and the results showed the cell growth was improved by 32% and tPA productivity by 250%.

  • PDF