• Title/Summary/Keyword: Ammonia removal rate

Search Result 223, Processing Time 0.02 seconds

Ammonia removal rate on ammonia loading rates in seawater filtering system using rotating biological contactor (RBC) (회전원판을 이용한 해수 순환여과 시스템에서 암모니아 부하율에 따른 암모니아 제거율)

  • SON Maeng Hyun;JEON Im Gi;CHO Kee Chae;KIM Kang Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.33 no.4
    • /
    • pp.367-372
    • /
    • 2000
  • A series of experiment was conducted to investigate the relationship between ammoia removal rate and ammonia loading rates in seawater filtering system using rotating biological contactor (RBC). In this experiment, RBC system was consisted of rotating polyvinyl film disks, which provided $12 m^2$ of total effective surface area in $0.075 m^3$ of volume. $NH_4Cl$ was added by $10{\~}150 g$ as a ammonia nitrogen source to determine ammonia removal rate in RBC system. Relationship between time required for ammonia removal (y: hour) and nitrogen inputted ($x: NH_4-N mg/l$) in RBC system was as followed: $y=3.51+7.76 lnx (r^2=0.936)$. At ammonia concentration $2 mg/l$, it took 10 hour for removal of ammonia in the RBC system. However, at ammonia concentration of $5 and 16.5 mg/l$, it took 16 and 27 hours, respectively. There was a decreasing tencency of an increasing ammonia in the rearing water. Finally, the ammonia removal rate in the RBC system increased with the rise of total ammonia concentration up to $16.5 mg/l$.

  • PDF

Ammonia Removal Characteristics by Pyroligneous Liquid at Livestock Farmhouse (축산농가에서 목초액을 이용한 암모니아 가스의 제거 특성에 관한 연구)

  • 박정호;전기일;정창훈
    • Journal of Environmental Science International
    • /
    • v.12 no.12
    • /
    • pp.1309-1313
    • /
    • 2003
  • This study was carried out to obtain the optimal ammonia removal efficiency using pyroligenous liquid for the economical and environment-friendly odor removal at a petty livestock farmhouse. The ammonia removal efficiencies were evaluated due to changing dilution rates(${\times}$10, ${\times}$20, ${\times}$30, ${\times}$50 and ${\times}$100 times) and different spray amounts(10$m\ell$ and 20$m\ell$) of pyroligenous liquid. The wet scrubber device was used to remove odor in closed-type livestock farmhouse. According to dilution rate of the pyroligenous liquid, the optimum rate was 20 times and the removal efficiency increased by decreasing dilution rates. In the case of spray amounts with the optimum dilution, the amount was 20 me and the removal efficiency increased by increasing spray amount. Also, the removal efficiency by using wet deodorizing device was 83.0-97.0% with 20 times diluted liquid.

Removal of ammonia by packed bed bioreactor using immobilized nitrifiers (고정화 생물 반응기에 의한 암모니아 제거)

  • 김병진;이경범;서근학
    • Journal of Environmental Science International
    • /
    • v.8 no.2
    • /
    • pp.177-182
    • /
    • 1999
  • Nitrifier consortium entrapped in Ca-alginate bead were packed into aerated packed bed bioreactor and non aerated packed bed bioreactor and the performances of two bioreactors were evaluated for the removal of ammonia nitrogen from synthetic aquaculture water. Total ammonia nitrogen(TAN) removal rate was decrease in aerated packed bed bioreactor below 0.3hr of hydraulic residence time(HRT), but increased in non aerated packed bed bioreactor until 0.5hr of HRT. At HRT of 0.05hr, TAN removal rate of non aerated packed bed bioreactor was about 335g TAN/㎥/day and the optimum ratio of packing height and inside diameter of reactor (H/D) was 4. The performance of two bioreactors indicated that non aerated packed bed bioreactor was better than aerated packed bed bioreactor in ammonia removal from synthetic aquaculture water.

  • PDF

Treatment of Piggery Wastewater by Anoxic-Oxic Biofilm Process (준혐기-호기 생물막 공정을 이용한 돈사폐수 처리)

  • 임재명;한동준
    • Journal of environmental and Sanitary engineering
    • /
    • v.12 no.2
    • /
    • pp.1-12
    • /
    • 1997
  • This research aims to develop biofilm process for the nutrient removal of piggery wastewater. The developed process is the four stage anoxic-oxic biofilm process with recirculation of the final effluent. In summery, the results are as follows: 1. Nitrification in the piggery wastewater built up nitrite because of the high strength ammonia nitrogen. The nitrification of nitrobacter by free ammonia was inhibited in the total ammonia nitrogen loading rate with more than 0.2 kgNH$_{3}$-N/m$^{3}$·d. 2. The maximal total ammonia nitrogen removal rate was obtained at 22$\circ $C and without being affected by the loading rate. But total oxidized nitrogen production rate was largely affected by loading rate. 3. Autooxidation by the organic limit was a cause of the phosphorus release in the aerobic biofilm process. But the phosphorus removal rate was 90 percent less than the influent phosphorus volumetric loading rate of above 0.1 kgP/m$^{3}$·d. Therefore, the phosphorus removal necessarily accompanied the influent loading rate. 4. On the anoxic-oxic BF process, the total average COD mass balance was approximately 67.6 percent. Under this condition, the COD mass removal showed that the cell synthesis and metabolism in aerobic reactor was 42.8 percent and that the denitrification in anoxic reactor was 10.7 percent, respectively.

  • PDF

Characteristics of Ammonia Removal by Natural Neutralizer (천연중화제를 이용한 암모니아 제거특성)

  • Kim, Tak-Hyun;Park, Hyung-Yong;Kim, Sangyong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.4
    • /
    • pp.651-659
    • /
    • 2000
  • The characteristics of ammonia removal by natural neutralizer were studied by using a scrubber type equipment. As operation parameters, neutralizer dilution ratio, neutralizer inlet flowrate, air flowrate and initial ammonia concentration were selected and their effects on ammonia removal efficiency were investigated. The optimal removal effect was achieved at neutralizer dilution ratio of 1.0% and neutralizer inlet flowrate of $60m{\ell}/min$. On the other hand, with respect to air flowrate and initial ammonia concentration, there was no significant effect on removal efficiency, when loading rate was considered. In addition, ammonia removal reaction was investigated by analyzing the ammonia oxides, such as nitrites and nitrates, after reacting ammonium solution with natural neutralizer. The result shows a partial oxidation by natural neutralizer besides dominant absorption of ammonia.

  • PDF

Effects of Pre-Oxidation for Recirculation of Aquaculture Wastewater (양어용수 재이용을 위한 전 산화처리의 효과)

  • Lim, Jae-Lim;Shin, Hang-Sik
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.1
    • /
    • pp.103-111
    • /
    • 2000
  • Ozonation and advanced oxidation($H_2O_2/O_3$) process were investigated under various experimental conditions to improve the efficiency of biological filter used for the treatment of recycled wastewater from aquaculture. Ammonia removal followed the first-order reaction whose reaction rate constant(k) was $2.0{\times}10^{-2}min^{-1}$ in ozonation. The ammonia removal rate increased according as the bicarbonate alkalinity is increased. About 46% $NH_3$ was oxidized by ozone at 200 mg/L as $CaCO_3$. When alkalinity existed in wastewater, ammonia removal rate by advanced oxidation was very low due to the inhibition effect of bicarbonate. However, when initial pH was adjusted to about 8.2 by 0.1 N KOH, ammonia removal rate was improved higher than that by ozonation. Especially. ammonia removal rate was the highest at $H_2O_2/O_3$ of 0.25 and about 90% of ammonia was removed in 30 min at this ratio as pH was maintained over 9. In the case of wastewater containing ammonia and organic constituents, ammonia removal efficiency by both ozonation and advanced oxidation decreased seriously because organic constituents consumed the oxidant faster than ammonia. In addition the optimal $H_2O_2/O_3$ ratio was changed. Like ammonia removal, DOC(dissolved organic carbon) increased for first 10 min and then decreased slowly because the particulate organic constituents were oxidized rapidly and then produce DOC. Even when the ammonia concentration by twice, oxidation of DOC was not retarded.

  • PDF

Ammonia Removal Characteristics of Biolfilm Reactor (생물막을 이용한 상수 원수에서의 암모니아 제거 특성)

  • Shin, Hang-Sik;Lim, Kycong-Ho;Lee, Sang-Min
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.10 no.1
    • /
    • pp.78-84
    • /
    • 1996
  • The presence of ammonia, usually in the form of ammonium ion ($NH_4{^+}$), can enhance bacterial growth m the distribution system and make the production of drinking water more costly if ammonium must be removed to ensure good disinfection. Removal of ammonia by biological oxidation could be economical which prevents excess chlorine dosage In this research, effects of hydraulic retention time (HRT) and media type on the ammonia removal efficiencies of submerged biofilm reactor were investigated. The biofilm reactors combined the characteristics of high biological solids capture efficiency and good hydraulic control. The results indicate that biofilms can remove over 77 percent of the ammonia with HRT of longer than 2 hr even at low temperature ranging from 14.6 to $16.6^{\circ}C$. The HRT has a significant effect on nitrification. The overall nitrification and efficiency of ammonia removal increase with increasing HRT. It has also been observed that when the fibrous media was used, the ammonia removal, nitrification rate and endurance to shock improved.

  • PDF

Removal of Ammonia-N by Immobilized Nitrifier Consortium (고정화된 질화 세균군에 의한 암모니아성 질소 제거)

  • 서근학;김병진;조문철;조진구;김용하;김성구
    • KSBB Journal
    • /
    • v.13 no.3
    • /
    • pp.238-243
    • /
    • 1998
  • Nitrifier consortium immobilized in Ca and Ba-alginate beads were packed into two bioreactors and the performances of bioreactors were evaluated for the removal of ammonia nitrogen from synthetic aquaculture water. The total ammonia nitrogen (TAN) concentration of the influent was continually kept about 2g TAN/㎥. At the HRT of 0.6hr, ammonia nitrogen removal rate of two bioreactors were about 52.6 and 51.0g TAN/$\textrm{m}^3$/day, respectively. At the respect of ammonia nitrogen removal, two bioreactor showed the similar abilities. The second trial with nitrifier consortium immobilized in Ca-alginate bead was carried out to evaluate the ammonia nitrogen removal rate for 35 days. The highest ammonia nitrogen removal rate was 82g TAN/$\textrm{m}^3$ when HRT was about 0.3hr.

  • PDF

The Recycling Water Treatment of High Density Fish Culture System Using the Aerated Submerged Filter -1. Ammonia Removal Characteristics in Sea Water- (폭기식 잠수여상을 이용한 고밀도 양식장의 순환수 처리 -1. 해수중의 암모니아 제거 특성-)

  • LEE Heon-Mo;LEE Jae-Kwan;JUNG Byung-Gon;YANG Byung-Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.26 no.5
    • /
    • pp.502-509
    • /
    • 1993
  • Submerged filter process was used to evaluate the nitrifying efficiency of ammonia in the recycling water of marine aquatic culture system. The ammonia removal efficiency was achieved as high as $99\%$ at the hydraulic surface loading rate of up to $4.3{\ell}/m^2-day$. And the nitrite accumulation did not occur in the reactor even when the hydraulic surface loading rate of up to $36.8{\ell}/m^2day$ was applied. In the present study, the relationship between the effluent ammonia concentration and ammonia surface loading rate was formulated as an equation. The attachment rate of biofilm on the filter media at the ammonia surface loading rate of 62.3 and $311.7mg/m^2day$ was 15 and $55mg/m^2-day$, respectively, showing the linear relationship between the attachment rate and ammonia loading rates. Biofilm thickness and density of the filter media were found to be the function of the ammonia loading rate.

  • PDF

Removal of Low Concentration Ammonia Nitrogen using a Packed Bed Bioreactor Immobilized with Nitrifier Consortium (질화세균을 고정화한 충전층 생물반응기에서 저농도 암모니아성 질소 제거)

  • Lee, Chang-Keun;Kim, Byong-Jin;Lee, Min-Su;Kim, Yong-Ha;Suh, Kuen-Hack
    • Clean Technology
    • /
    • v.13 no.1 s.36
    • /
    • pp.16-21
    • /
    • 2007
  • This study estimated the effect of hydraulic residence time(HRT), influent total ammonia nitrogen(TAN) concentration, temperature and pH in the packed-bed bioreactor using immobilized nitrifiers. Removal rate of ammonia nitrogen was increased with decreasing HRT and the optimum HRT was 0.2 hour when influent TAN was $2g/m^3$. At this point, removal rate was $226.1\;g/m^3{\cdot}day$ and removal efficiency was 88.8%. Removal rate of ammonia nitrogen was Increased with increasing TAN concentration. Removal rate and efficiency of ammonia nitrogen were kept constant at $20{\sim}35^{\circ}C$ and pH $8{\sim}9$ value.

  • PDF