• Title/Summary/Keyword: Ammonia half-saturation constant

Search Result 2, Processing Time 0.014 seconds

Ammonia half-saturation constants of sludge with different community compositions of ammonia-oxidizing bacteria

  • Kayee, Pantip;Rongsayamanont, Chaiwat;Kunapongkiti, Pattaraporn;Limpiyakorn, Tawan
    • Environmental Engineering Research
    • /
    • v.21 no.2
    • /
    • pp.140-144
    • /
    • 2016
  • Owing to the kinetic differences in ammonia oxidation among ammonia-oxidizing microorganisms (AOM), there is no standard set of kinetic values that can be used as a representative set for nitrifying wastewater treatment plant (WWTP) design. As a result, this study clarified a link between the half-saturation constants for ammonia oxidation (Ks) and the dominant ammonia-oxidizing bacterial (AOB) groups in sludge from full-scale WWTPs and laboratory-scale nitrifying reactors. Quantitative polymerase chain reaction analyses revealed that AOB affiliated with the Nitrosomonas oligotropha cluster were the dominant AOM groups in the sludge taken from the low-ammonia-level WWTPs, while AOB associate with the Nitrosomonas europaea cluster comprised the majority of AOM groups in the sludge taken from the high-ammonia-level WWTPs and nitrifying reactors. A respirometric assay demonstrated that the ammonia Ks values for the high-ammonia-level WWTPs and nitrifying reactors were higher than those of the low-ammonia-level plants. Using the Ks values of available AOM cultures as a reference, the Ks values of the analyzed sludge were mainly influenced by the dominant AOB species. These findings implied that.different sets of kinetic values may be required for WWTPs with different dominant AOM species for more accurate WWTP design and operations.

Effects of Disinfectant Concentration, pH, Temperature, Ammonia, and Suspended Solids on the Chlorine Disinfection of Combined Sewer Overflow (소독제 농도, pH, 온도, 암모니아 농도, 부유물질이 강우 월류수 염소 소독에 미치는 영향)

  • Kim, Sang-Hyoun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.10
    • /
    • pp.685-690
    • /
    • 2014
  • The treatment of combined sewer overflow (CSO) is one of potential concerns in domestic wastewater treatment in Korea due to the pre-announce of CSO regulations. This work investigated the effects of disinfectant (NaOCl) concentration (0.11 to 4.0 mg $Cl_2/L$), pH (6.5 to 8.0), temperature (15 to $25^{\circ}C$), ammonia (10 to 41 mg N/L), and suspended solids (91 to 271 mg SS/L) on the chlorine disinfection of CSO. The effect of NaOCl concentration on the pseudo-$1^{st}$ order reaction rate for total coliform inactivation was described well with a saturation-type model with the half-velocity constant of 1.212 mg/L. The total coliform inactivation reaction rate decreased with SS and pH, and increased with temperature. Ammonia in the examined range did not affect the disinfection kinetics. A chlorine contact tank with the injection chlorine level of 1 mg $Cl_2/L$ and the hydraulic retention time of 1.25 min is estimated to reduce total coliform from $1{\times}10^5MPN/mL$ to 1,000 MPN/mL at 271 mg SS/L, $15^{\circ}C$, and pH 8.0. Chlorine would be a proper option for the disinfection of CSO.