• 제목/요약/키워드: Ambient area

검색결과 602건 처리시간 0.026초

Task-Ambient 공조시스템의 난방시 열환경 특성에 관한 실험적 연구 (The Thermal Environmental Characteristics for Task-Ambient Air-Conditioning System in Heating Condition)

  • 이정재;윤창오;정광섭;한화택;박영철
    • 설비공학논문집
    • /
    • 제13권2호
    • /
    • pp.115-121
    • /
    • 2001
  • Recently, the requirement of healthier and more comfortable environment makes the zoning domain more details. However, it has limitation to satisfy the thermal comfort of an individual because of the effect of the heat generation from the OA machine and partitions in indoor room. In this paper, we certify the validity of task-ambient air-conditioning system that has been developed as a new concept of personal air-conditioning system, and specify design strategies for more efficient task-ambient air-conditioning system with a specification guided by indoor environmental characteristics analyzed through experiment data. In this experiment, we changed the temperature and the quantity of air-flow in task domain to understand characteristic behavior of the thermal environment and investigate the possibility of energy saving. The experiment result is that the environment of the task area depends on the condition of supply air, and though the airflow of the low temperature is supplied with the ambient area, the personal environment and the efficiency of energy saving are improved by controlling the temperature and the quantity of the air shot around the task domain.

  • PDF

고온.고압 환경에서 가열평판에 충돌하는 디젤분무의 특성 (Characteristics of Impinging Diesel Spray on the Heated Flat Wall in High Temperature and High Pressure Environments)

  • 임경훈;이봉수;김종현;구자예
    • 대한기계학회논문집B
    • /
    • 제25권5호
    • /
    • pp.627-633
    • /
    • 2001
  • Characteristics of a diesel spray impingement with the variation of ambient temperature, wall temperature and ambient pressure were investigated through shadowgraphy method by using high speed camera. The radial penetration of spray was increased with ambient temperature and wall temperature. It is resulted from the decrease of ambient gas density caused by the increase of temperature. The height of spray was also increased with ambient temperature and wall temperature, because the height of stagnate region is noticeably increased, although height of wall jet vortex is decreased. At the same ambient pressure, the area ratio of impinging spray of room temperature environment to high temperature environment was increased, as the temperature difference between room temperature and high temperature increases. And the increment of area ratio was higher at low ambient pressure than high ambient pressure.

서울시 주요도로변 대기 중 니켈, 크롬, 구리 농도와 차종별 교통량과의 상관관계에 관한 연구 (A Study on Ni, Cr and Cu Concentrations of Ambient Air Adjacent to Heavy Traffic Road Side in Seoul and Correlations between Those and Traffic Volume by Types of Car)

  • 조준호;박석환
    • 한국환경보건학회지
    • /
    • 제25권3호
    • /
    • pp.51-57
    • /
    • 1999
  • This study was carried out to investigate the concentrations of Ni, Cr and Cu, to analyze the correlations among those, and between concentrations and traffic volumes by type of car in roadside ambient air at Chongro-, Chungkechon- and Kangnam terminal- area in Seoul from October 1st to October 31st in 1997. The results were as follows ; 1. The means of concentrations of Ni in roadside ambient air were 34.1, 25.1 and 23.6 ng/m$^3$ at Chungkechon, Kangnam terminal and Chongro area, respectively. The highest concentrations of Ni by time were 26.8 in the evening, 45.5 in the evening and 49.4 ng/m$^3$ in the forenoon at Chongro, Chungkechon and Kangnam terminal area, respectively. 2. The means of concentrations of Cr in road side ambient air were 97.7, 80.1 and 70.9 ng/m$^3$ at Chong, Chungkechon and Kangnam terminal area, respectively. The highest concentrations of Cu by time were 205.3 in the evening, 114.4 in the evening and 92.3 ng/m$^3$ in the forenoon at Chongro, Chungkechon and Kangnam terminal area, respectively. 4. The tendencies of concentrations of Ni and Cr by time were similar to each other. Especially, at Kangnam terminal area, correlation coefficients between concentrations of Ni and Cr and the traffic volume of bus were high(r=0.997,0.975). 5. The tendency of concentration of Cu and the traffic volume of passenger car at each area were high(r=0.832, 0.968) 6. Correlation coefficients between Cu and Zn, and between Ni and Cr were 0.762 and 0.842, respectively. This means that the possibility of co-existence of Cu-Zn or Ni-Cr is very high.

  • PDF

대구지역 공단과 인근 주거지역의 휘발성유기화합물질 오염도 평가 (Evaluation of Volatile Organic Compounds Levels in Industrial Complex and Nearby Residential Areas of Daegu)

  • 조완근;이진우
    • 한국환경과학회지
    • /
    • 제13권6호
    • /
    • pp.519-525
    • /
    • 2004
  • Air pollution from the Daegu industrial complex (Die) in Korea has been a common nuisance and cause of complaints for nearby residents. The current study measured the indoor and outdoor levels of six VOC (benzene, toluene, ethylbenzene, and three isomeric xylenes) at two residential areas with a different proximity to the ODIC, plus the ambient levels at two industrial areas within the boundary of the DDIC. The QA/QC program included the range of correlation coefficient (0.94-0.99) for calibration curves, within the permissible range. Toluene was the most abundant VOC in the ambient air both in residential and industrial areas. Both indoor and outdoor air concentrations of all target VOC except benzene were higher in residential area near the DIC compared to that further away from the DIC. Moreover, the ambient air concentrations of all target VOC except benzene for two industrial sites (A and B) were significantly higher than the outdoor or indoor air concentrations in the two residential areas. The findings further suggested that VOC ambient levels measured in a residential area near the DIC be used as a potential indicator of odor-causing unidentified air pollutants transported from the DIC. Moreover, it was found that the elevated ambient toluene levels outweighed the indoor sources with respect to the environmental exposure of residents nearby the DIC. However, in the residential area further away from the DIC, the toluene indoor sources outweighed the outdoor sources.

분사 조건이 다공형 GDI 인젝터의 분무 거동에 미치는 영향 (Effect of Injection Conditions on the Spray Behaviors of the Multi-hole GDI Injector)

  • 박정환;박수한;이창식;박성욱
    • 한국자동차공학회논문집
    • /
    • 제20권2호
    • /
    • pp.116-122
    • /
    • 2012
  • The purpose of this study is to investigate the overall spray behavior characteristics for various injection conditions in a gasoline direct injection(GDI) injector with multi-hole. The spray characteristics, such as the spray penetration, the spray angle, and the injection quantity, were studied through the change of the injection pressure, the ambient pressure, and the energizing duration in a high-pressure chamber with a constant volume. The n-heptane with 99.5% purity was used as the test fuel. In a constant volume chamber, the injected spray was visualized by the spray visualization system, which consisted of the high-speed camera, the metal-halide lamp, the injector control device, and the image analysis system with the image processing program. It was revealed that the injection quantity was mainly affected by the difference between the injection pressure and the ambient pressure. For low injection pressure conditions, the injection quantity was decreased by the increase of the ambient pressure, while it nearly maintained regardless of the ambient pressure at high injection pressure. According to the increase of the ambient pressure in the constant volume chamber, the spray development became slow, consequently, the spray tip penetration decreased, and the spray area increased. In additions, the circular cone area decreased, and the vortex area increased.

한국과 일본의 환경대기 중 폴리염화비페닐(PCB)의 농도수준 및 발생원 해석에 관한 연구 (A Study on Pollution Levels and Source of Polychlorinated Biphenyl (PCB) in the Ambient Air of Korea and Japan)

  • 김정수;송병주;김종국;김교근
    • 대한환경공학회지
    • /
    • 제27권2호
    • /
    • pp.170-176
    • /
    • 2005
  • 한국과 일본의 환경대기 시료를 대상으로 PCB 전이성질체 분석을 통하여, 오염정도 및 이성질체 분포 특성을 파악하고 통계적 처리기법을 통하여 발생원을 추정하였다. 환경대기 중 PCB 농도는 한국이 $0.003{\sim}1.01\;pgTEQ/m^3$ (평균 $0.22\;pgTEQ/m^3$), 일본이 $0.002{\sim}0.014\;pgTEQ/m^3$(평균 $0.007\;pgTEQ/m^3$)으로 나타났다. 한국의 환경대기 중 PCB 농도는 공단지역이 도시지역간의 농도 변화폭이 매우 크게 나타났다. 이성질체 분포에 있어서는 대체로 유사한 경향을 나타내었으나 한국의 공단 지역에서는 $7{\sim}10CB$의 고염소화 동족체가 검출되어 특정한 오염원이 존재할 가능성이 시사되었다. 주성분 분석을 통하여 한국과 일본의 환경대기 중 PCB 오염원을 추정한 결과 한국 환경대기 시료가 일본 환경대기 시료에 비하여 소각로 영향을 많이 받고 있으며 PCB 제품 영향은 일본에 비해 상대적으로 적은 것으로 판단된다.

저온측과 고온측 냉매간 열교환이 열펌프의 성능특성에 미치는 영향 (Effect of the Heat Exchange between Low and High Temperature Refrigerant on the Heat Pump Performance)

  • 이건중;송현갑
    • Journal of Biosystems Engineering
    • /
    • 제24권4호
    • /
    • pp.343-350
    • /
    • 1999
  • The ambient air is commonly used as low-temperature heat source for heat pump operation. However, the coefficient of performance(COP) of the air to water heat pump is decreased with the ambient air temperature drop. In this study to solve this problem, the AVACTHE(Automatic Variable Area Capillary Type Heat Exchanger) with 3 levels of heat exchange area(0, 1,495.4, 1,794.5$\textrm{cm}^2$)was installed in the refrigerant circuit of the heat pump. The AVACTHE effect on the performance of heat pump was tested with the ambient air temperature variation. The COP improvement of the heat pump could be achieved by the AVACTHE installation when below -5$^{\circ}C$ of the ambient air temperature.

  • PDF

저온측과 고온측 냉매간 열교환이 열펌프의 성능특성에 미치는 영향 (Effect of the Heat Exchange between Low and High Temperature Refrigerant on the Heat Pump Performance)

  • 이건중;송현갑
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1999년도 동계 학술대회 논문집
    • /
    • pp.211-218
    • /
    • 1999
  • The ambient air is commonly used as low-temperature heat sources for heat pump operation. However, the coefficient of performance (COP) of the air -water heat pump is decreased with the ambient air temperature drop. In this study to solve this problem , the AVACTHE(Automatic Variable Area Capillary Type Heat Exchanger) with 3 levels of heat exchange area(0, 1495.4, 1794.5$\textrm{cm}^2$) was installed in the refrigerant circuit of the heat pump. The AVACTHE effect on the performance of heat pump was tested with the ambient air temperature variation. The high level COP of the heat pump could be achieved by the AVACTHE installation when below -5$^{\circ}C$ of the ambient air temperature.

  • PDF

Spatial Analysis of Ambient Air Quality Using GIS

  • Choi, Byoung-Gil;Lee, Hee-Kwan;Ra, Young-Woo
    • Korean Journal of Geomatics
    • /
    • 제2권2호
    • /
    • pp.145-151
    • /
    • 2002
  • GIS technique is applied to the analysis of ambient air quality information. For this study, the TMS-monitored air quality information was imported with the geographical information of the TMS stations in Capital Area. It is found that currently available GIS technique has a great extend of potential for air quality management. From the analysis of air quality information, the GIS application demonstrates the poor air quality in the central Capital Area and the it is improved as it travels down to the suburb area. The ambient air quality is also proven to be highly influenced by the ozone concentration in a mid-summer day.

  • PDF

경기도 환경대기중 휘발성유기화합물의 오염실태 조사연구 (III) (A Study on the VOCs Contamination of Ambient Air int Kyonggi-do Area (III))

  • 김종보;김종찬;최승석;임흥빈;최양희;이수문
    • 환경위생공학
    • /
    • 제17권2호
    • /
    • pp.63-70
    • /
    • 2002
  • We investigated the concentration degree of VOCs for ambient air in the air environment control area of Kyonggi-do in 2001. The VOCs showing higher concentration were in the ascending order of Toluene > n-Butane > 1-Butene > Benzene > n-Hexane. The concentration distribution ratio mentioned above showed almost same pattern in each city. The relative concentration ratio of Benzene, Toluene, Ethylbenzene, Xylenes which are aromatic VOCs were 1 : 6.3 : 0.6 : 1.6. It was similar to the pattern in 1999 but different from the pattern in 2000. In the aspect of seasons, the highest B.T.E.X concentration was indicated in fall and in the aspect of areas, the higher concentration showed in the ascending order of Buchon > Ansan > Kwangmyong > Shihung > Sungnam. The average concentration of target VOCs for ambient air in the air environment control area of Kyonggi-do showed lower concentration than the metropolis of Seoul but higher concentration than Kwang-ju city and Dae-gu city. The amount of total VOCs was increasing, comparing with it last year and the more increasing tendency is anticipated so that it will need to establish the proper regulative criteria.