• Title/Summary/Keyword: Ambient area

Search Result 602, Processing Time 0.025 seconds

The Thermal Environmental Characteristics for Task-Ambient Air-Conditioning System in Heating Condition (Task-Ambient 공조시스템의 난방시 열환경 특성에 관한 실험적 연구)

  • 이정재;윤창오;정광섭;한화택;박영철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.2
    • /
    • pp.115-121
    • /
    • 2001
  • Recently, the requirement of healthier and more comfortable environment makes the zoning domain more details. However, it has limitation to satisfy the thermal comfort of an individual because of the effect of the heat generation from the OA machine and partitions in indoor room. In this paper, we certify the validity of task-ambient air-conditioning system that has been developed as a new concept of personal air-conditioning system, and specify design strategies for more efficient task-ambient air-conditioning system with a specification guided by indoor environmental characteristics analyzed through experiment data. In this experiment, we changed the temperature and the quantity of air-flow in task domain to understand characteristic behavior of the thermal environment and investigate the possibility of energy saving. The experiment result is that the environment of the task area depends on the condition of supply air, and though the airflow of the low temperature is supplied with the ambient area, the personal environment and the efficiency of energy saving are improved by controlling the temperature and the quantity of the air shot around the task domain.

  • PDF

Characteristics of Impinging Diesel Spray on the Heated Flat Wall in High Temperature and High Pressure Environments (고온.고압 환경에서 가열평판에 충돌하는 디젤분무의 특성)

  • Im, Gyeong-Hun;Lee, Bong-Su;Kim, Jong-Hyeon;Gu, Ja-Ye
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.5
    • /
    • pp.627-633
    • /
    • 2001
  • Characteristics of a diesel spray impingement with the variation of ambient temperature, wall temperature and ambient pressure were investigated through shadowgraphy method by using high speed camera. The radial penetration of spray was increased with ambient temperature and wall temperature. It is resulted from the decrease of ambient gas density caused by the increase of temperature. The height of spray was also increased with ambient temperature and wall temperature, because the height of stagnate region is noticeably increased, although height of wall jet vortex is decreased. At the same ambient pressure, the area ratio of impinging spray of room temperature environment to high temperature environment was increased, as the temperature difference between room temperature and high temperature increases. And the increment of area ratio was higher at low ambient pressure than high ambient pressure.

A Study on Ni, Cr and Cu Concentrations of Ambient Air Adjacent to Heavy Traffic Road Side in Seoul and Correlations between Those and Traffic Volume by Types of Car (서울시 주요도로변 대기 중 니켈, 크롬, 구리 농도와 차종별 교통량과의 상관관계에 관한 연구)

  • Jo, Jun-Ho;Park, Seok-Hwan
    • Journal of Environmental Health Sciences
    • /
    • v.25 no.3
    • /
    • pp.51-57
    • /
    • 1999
  • This study was carried out to investigate the concentrations of Ni, Cr and Cu, to analyze the correlations among those, and between concentrations and traffic volumes by type of car in roadside ambient air at Chongro-, Chungkechon- and Kangnam terminal- area in Seoul from October 1st to October 31st in 1997. The results were as follows ; 1. The means of concentrations of Ni in roadside ambient air were 34.1, 25.1 and 23.6 ng/m$^3$ at Chungkechon, Kangnam terminal and Chongro area, respectively. The highest concentrations of Ni by time were 26.8 in the evening, 45.5 in the evening and 49.4 ng/m$^3$ in the forenoon at Chongro, Chungkechon and Kangnam terminal area, respectively. 2. The means of concentrations of Cr in road side ambient air were 97.7, 80.1 and 70.9 ng/m$^3$ at Chong, Chungkechon and Kangnam terminal area, respectively. The highest concentrations of Cu by time were 205.3 in the evening, 114.4 in the evening and 92.3 ng/m$^3$ in the forenoon at Chongro, Chungkechon and Kangnam terminal area, respectively. 4. The tendencies of concentrations of Ni and Cr by time were similar to each other. Especially, at Kangnam terminal area, correlation coefficients between concentrations of Ni and Cr and the traffic volume of bus were high(r=0.997,0.975). 5. The tendency of concentration of Cu and the traffic volume of passenger car at each area were high(r=0.832, 0.968) 6. Correlation coefficients between Cu and Zn, and between Ni and Cr were 0.762 and 0.842, respectively. This means that the possibility of co-existence of Cu-Zn or Ni-Cr is very high.

  • PDF

Evaluation of Volatile Organic Compounds Levels in Industrial Complex and Nearby Residential Areas of Daegu (대구지역 공단과 인근 주거지역의 휘발성유기화합물질 오염도 평가)

  • Jo, Wan Geun;Lee, Jin U
    • Journal of Environmental Science International
    • /
    • v.13 no.6
    • /
    • pp.519-525
    • /
    • 2004
  • Air pollution from the Daegu industrial complex (Die) in Korea has been a common nuisance and cause of complaints for nearby residents. The current study measured the indoor and outdoor levels of six VOC (benzene, toluene, ethylbenzene, and three isomeric xylenes) at two residential areas with a different proximity to the ODIC, plus the ambient levels at two industrial areas within the boundary of the DDIC. The QA/QC program included the range of correlation coefficient (0.94-0.99) for calibration curves, within the permissible range. Toluene was the most abundant VOC in the ambient air both in residential and industrial areas. Both indoor and outdoor air concentrations of all target VOC except benzene were higher in residential area near the DIC compared to that further away from the DIC. Moreover, the ambient air concentrations of all target VOC except benzene for two industrial sites (A and B) were significantly higher than the outdoor or indoor air concentrations in the two residential areas. The findings further suggested that VOC ambient levels measured in a residential area near the DIC be used as a potential indicator of odor-causing unidentified air pollutants transported from the DIC. Moreover, it was found that the elevated ambient toluene levels outweighed the indoor sources with respect to the environmental exposure of residents nearby the DIC. However, in the residential area further away from the DIC, the toluene indoor sources outweighed the outdoor sources.

Effect of Injection Conditions on the Spray Behaviors of the Multi-hole GDI Injector (분사 조건이 다공형 GDI 인젝터의 분무 거동에 미치는 영향)

  • Park, Jeong-Hwan;Park, Su-Han;Lee, Chang-Sik;Park, Sung-Wook
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.2
    • /
    • pp.116-122
    • /
    • 2012
  • The purpose of this study is to investigate the overall spray behavior characteristics for various injection conditions in a gasoline direct injection(GDI) injector with multi-hole. The spray characteristics, such as the spray penetration, the spray angle, and the injection quantity, were studied through the change of the injection pressure, the ambient pressure, and the energizing duration in a high-pressure chamber with a constant volume. The n-heptane with 99.5% purity was used as the test fuel. In a constant volume chamber, the injected spray was visualized by the spray visualization system, which consisted of the high-speed camera, the metal-halide lamp, the injector control device, and the image analysis system with the image processing program. It was revealed that the injection quantity was mainly affected by the difference between the injection pressure and the ambient pressure. For low injection pressure conditions, the injection quantity was decreased by the increase of the ambient pressure, while it nearly maintained regardless of the ambient pressure at high injection pressure. According to the increase of the ambient pressure in the constant volume chamber, the spray development became slow, consequently, the spray tip penetration decreased, and the spray area increased. In additions, the circular cone area decreased, and the vortex area increased.

A Study on Pollution Levels and Source of Polychlorinated Biphenyl (PCB) in the Ambient Air of Korea and Japan (한국과 일본의 환경대기 중 폴리염화비페닐(PCB)의 농도수준 및 발생원 해석에 관한 연구)

  • Kim, Kyoung-Soo;Song, Byung-Joo;Kim, Jong-Guk;Kim, Kyeo-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.2
    • /
    • pp.170-176
    • /
    • 2005
  • This study was conducted to investigate the level of PCBs and distribution of PCB congeners in the ambient air of Korea and Japan. The source of PCBs were also studied by a statistical method. The TEQ concentration of PCB in the ambient air of Korea and Japan were between 0.003 and $1.01\;pgTEQ/m^3$(mean value : $0.22\;pgTEQ/m^3$) and between 0.002 and $0.014\;pgTEQ/m^3$ (mean value: $0.007\;pgTEQ/m^3$), respectively. The ambient air of industrial area of Korea showed a fluctuation in PCB concentration than other sampling area. The isomer distribution patterns in the ambient air was more or less similar in all sampling places. In addition, highly chlorinated homologues ($7{\sim}10CB$) were detected in the only Korea industrial area. This observation suggests that there is a possibility of specific source of PCBs in the industrial area. The source identification of PCB in ambient air was performed using multivariate statistical analysis(principal component analysis). As a result, it is estimated that the Korean ambient air was more influenced by combustion process than the ambient air of Japan and also the effect of PCB commercial products was relatively a small.

Effect of the Heat Exchange between Low and High Temperature Refrigerant on the Heat Pump Performance (저온측과 고온측 냉매간 열교환이 열펌프의 성능특성에 미치는 영향)

  • 이건중;송현갑
    • Journal of Biosystems Engineering
    • /
    • v.24 no.4
    • /
    • pp.343-350
    • /
    • 1999
  • The ambient air is commonly used as low-temperature heat source for heat pump operation. However, the coefficient of performance(COP) of the air to water heat pump is decreased with the ambient air temperature drop. In this study to solve this problem, the AVACTHE(Automatic Variable Area Capillary Type Heat Exchanger) with 3 levels of heat exchange area(0, 1,495.4, 1,794.5$\textrm{cm}^2$)was installed in the refrigerant circuit of the heat pump. The AVACTHE effect on the performance of heat pump was tested with the ambient air temperature variation. The COP improvement of the heat pump could be achieved by the AVACTHE installation when below -5$^{\circ}C$ of the ambient air temperature.

  • PDF

Effect of the Heat Exchange between Low and High Temperature Refrigerant on the Heat Pump Performance (저온측과 고온측 냉매간 열교환이 열펌프의 성능특성에 미치는 영향)

  • 이건중;송현갑
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1999.12a
    • /
    • pp.211-218
    • /
    • 1999
  • The ambient air is commonly used as low-temperature heat sources for heat pump operation. However, the coefficient of performance (COP) of the air -water heat pump is decreased with the ambient air temperature drop. In this study to solve this problem , the AVACTHE(Automatic Variable Area Capillary Type Heat Exchanger) with 3 levels of heat exchange area(0, 1495.4, 1794.5$\textrm{cm}^2$) was installed in the refrigerant circuit of the heat pump. The AVACTHE effect on the performance of heat pump was tested with the ambient air temperature variation. The high level COP of the heat pump could be achieved by the AVACTHE installation when below -5$^{\circ}C$ of the ambient air temperature.

  • PDF

Spatial Analysis of Ambient Air Quality Using GIS

  • Choi, Byoung-Gil;Lee, Hee-Kwan;Ra, Young-Woo
    • Korean Journal of Geomatics
    • /
    • v.2 no.2
    • /
    • pp.145-151
    • /
    • 2002
  • GIS technique is applied to the analysis of ambient air quality information. For this study, the TMS-monitored air quality information was imported with the geographical information of the TMS stations in Capital Area. It is found that currently available GIS technique has a great extend of potential for air quality management. From the analysis of air quality information, the GIS application demonstrates the poor air quality in the central Capital Area and the it is improved as it travels down to the suburb area. The ambient air quality is also proven to be highly influenced by the ozone concentration in a mid-summer day.

  • PDF

A Study on the VOCs Contamination of Ambient Air int Kyonggi-do Area (III) (경기도 환경대기중 휘발성유기화합물의 오염실태 조사연구 (III))

  • 김종보;김종찬;최승석;임흥빈;최양희;이수문
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.2
    • /
    • pp.63-70
    • /
    • 2002
  • We investigated the concentration degree of VOCs for ambient air in the air environment control area of Kyonggi-do in 2001. The VOCs showing higher concentration were in the ascending order of Toluene > n-Butane > 1-Butene > Benzene > n-Hexane. The concentration distribution ratio mentioned above showed almost same pattern in each city. The relative concentration ratio of Benzene, Toluene, Ethylbenzene, Xylenes which are aromatic VOCs were 1 : 6.3 : 0.6 : 1.6. It was similar to the pattern in 1999 but different from the pattern in 2000. In the aspect of seasons, the highest B.T.E.X concentration was indicated in fall and in the aspect of areas, the higher concentration showed in the ascending order of Buchon > Ansan > Kwangmyong > Shihung > Sungnam. The average concentration of target VOCs for ambient air in the air environment control area of Kyonggi-do showed lower concentration than the metropolis of Seoul but higher concentration than Kwang-ju city and Dae-gu city. The amount of total VOCs was increasing, comparing with it last year and the more increasing tendency is anticipated so that it will need to establish the proper regulative criteria.