대기오염집중측정소별 2013~2015년 사이의 PM2.5 화학적 특성 차이 및 유발인자 조사 (Difference in Chemical Composition of PM2.5 and Investigation of its Causing Factors between 2013 and 2015 in Air Pollution Intensive Monitoring Stations)

  • 유근혜;박승식;김영성;신혜정;임철수;반수진;유정아;강현정;서영교;강경식;조미라;정선아;이민희;황태경;강병철;김효선
    • 한국대기환경학회지
    • /
    • 제34권1호
    • /
    • pp.16-37
    • /
    • 2018
  • In this study, difference in chemical composition of $PM_{2.5}$ observed between the year 2013 and 2015 at six air quality intensive monitoring stations (Bangryenogdo (BR), Seoul (SL), Daejeon (DJ), Gwangju (GJ), Ulsan (US), and Jeju (JJ)) was investigated and the possible factors causing their difference were also discussed. $PM_{2.5}$, organic and elemental carbon (OC and EC), and water-soluble ionic species concentrations were observed on a hourly basis in the six stations. The difference in chemical composition by regions was examined based on emissions of gaseous criteria pollutants (CO, $SO_2$, and $NO_2$), meteorological parameters (wind speed, temperature, and relative humidity), and origins and transport pathways of air masses. For the years 2013 and 2014, annual average $PM_{2.5}$ was in the order of SL ($${\sim_=}DJ$$)>GJ>BR>US>JJ, but the highest concentration in 2015 was found at DJ, following by GJ ($${\sim_=}SJ$$)>BR>US>JJ. Similar patterns were found in $SO{_4}^{2-}$, $NO_3{^-}$, and $NH_4{^+}$. Lower $PM_{2.5}$ at SL than at DJ and GJ was resulted from low concentrations of secondary ionic species. Annual average concentrations of OC and EC by regions had no big difference among the years, but their patterns were distinct from the $PM_{2.5}$, $SO{_4}^{2-}$, $NO_3{^-}$, and $NH_4{^+}$ concentrations by regions. 4-day air mass backward trajectory calculations indicated that in the event of daily average $PM_{2.5}$ exceeding the monthly average values, >70% of the air masses reaching the all stations were coming from northeastern Chinese polluted regions, indicating the long-range transportation (LTP) was an important contributor to $PM_{2.5}$ and its chemical composition at the stations. Lower concentrations of secondary ionic species and $PM_{2.5}$ at SL in 2015 than those at DJ and GJ sites were due to the decrease in impact by LTP from polluted Chinese regions, rather than the difference in local emissions of criteria gas pollutants ($SO_2$, $NO_2$, and $NH_3$) among the SL, DJ, and GJ sites. The difference in annual average $SO{_4}^{2-}$ by regions was resulted from combination of the difference in local $SO_2$ emissions and chemical conversion of $SO_2$ to $SO{_4}^{2-}$, and LTP from China. However, the $SO{_4}^{2-}$ at the sites were more influenced by LTP than the formation by chemical transformation of locally emitted $SO_2$. The $NO_3{^-}$ increase was closely associated with the increase in local emissions of nitrogen oxides at four urban sites except for the BR and JJ, as well as the LTP with a small contribution. Among the meterological parameters (wind speed, temperature, and relative humidity), the ambient temperature was most important factor to control the variation of $PM_{2.5}$ and its major chemical components concentrations. In other words, as the average temperature increases, the $PM_{2.5}$, OC, EC, and $NO_3{^-}$ concentrations showed a decreasing tendency, especially with a prominent feature in $NO_3{^-}$. Results from a case study that examined the $PM_{2.5}$ and its major chemical data observed between February 19 and March 2, 2014 at the all stations suggest that ambient $SO{_4}^{2-}$ and $NO_3{^-}$ concentrations are not necessarily proportional to the concentrations of their precursor emissions because the rates at which they form and their gas/particle partitioning may be controlled by factors (e.g., long range transportation) other than the concentration of the precursor gases.

물의 T-s 선도 상에서 엑서지 및 엑서지율의 고찰 (Consideration of Exergy and Exergy Ratio on T-s Chart of Water)

  • 김덕진;김덕봉
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.827-832
    • /
    • 2009
  • Exergy is the amount of reversible work obtainable when some matter is brought to a state of thermodynamic equilibrium with ambient. This exergy is availability or useful work induced from carnot cycle, and this can calculate the irreversible loss work which occurs within any thermal or power cycle. The exergy ratio is the value of exergy divided by enthalpy of ambient reference, where the quality of energy or enthalpy in substances is evaluated by exergy ratio. Exergy is very important in optimal design method of thermal system or each component, and the value of exergy at given state is calculated by equation. Here, designer can easily understand and find the value of enthalpy because enthalpy is graphically drawn in chart, however exergy did not. In this paper, exergy and exergy ratio of air were drawn on temperature-entropy chart, and we wish to this chart is a help to design, analysis and education.

  • PDF

대기오염 수준이 교통수단별 통행시간에 미치는 영향 분석 (The Impact of Air Quality on Traveling Time by Transportation Mode)

  • 조은정;김현철
    • 자원ㆍ환경경제연구
    • /
    • 제30권2호
    • /
    • pp.207-235
    • /
    • 2021
  • 본 논문은 오존과 미세먼지 수준이 도보, 자가용, 버스, 전철의 통행시간에 미치는 영향을 분석한다. 가구통행실태조사 자료와 SUR 모형을 이용하여 분석한 결과, 대기오염 농도가 높아질수록 자가용 통행시간이 증가하고, 버스의 통행시간이 감소하는 것으로 나타난다. 그러나 대기오염 경보가 발령되면 버스의 통행시간이 증가하는 공익적 행위가 일부 나타나지만, 자가용의 통행시간이 증가하거나 변화가 없고, 전철의 통행시간이 증가하지 않는 것으로 나타난다. 이는 경보의 발령으로 제공되는 정보가 배출 저감을 위한 통행행태 변화보다는 오염상황에의 노출을 줄이는 회피행동에 더 큰 영향을 미쳤음을 시사한다.

대구지역 공중이용시설의 실내 $\cdot$ 외 공기 중 기준성오염물질의 농도 (Concentrations of Criteria Pollutants in Indoor and Ambient Air of Public Facilities in Taegu Area)

  • 송희봉;민경섭;한개희;김종우;백성옥
    • 한국대기환경학회지
    • /
    • 제12권4호
    • /
    • pp.429-439
    • /
    • 1996
  • A comprehensive air quality monitoring was carried out in this study to investigate the concentrations of criteria air pollutants in indoor and outdoor air of public facilities in Taegu area. Four different kinds of public facilities were seleced as sampling sites, which are underground stores, stations & terminals, general hospitals, and department stores. Each group of the public facilities was consisted of three different sampling sites. As a consequence, a total of 12 different sampling sites were surveyed throughout this study. Sampling was conducted simultaneously indoors, three times per day (in the morning, afternoon, and evening) and four times per year (spring, summer, fall, and winter) at each sampling site during the period of October 1994 to July 1995. A range of criteria pollutants were measured in order to obtain a broad profile of indoor and ambient air quality, including total suspended particles (TSP), carbon monoxide (CO), carbon dioxide ($CO_2$), formaldehyde (HCHO), sulfur dioxide ($SO_2$), and nitrogen dioxide ($NO_2$). In addition, temperature, relative humidity, and air current were measured on site together with those air pollutants. Results of this study indicated that the indoor levels of TSP, CO, $SO_2, and NO_2$ appeared to be generally higher in stations/terminals and underground stores than those in department stores and hospitals. However, HCHO and $CO_2$ were found to have higher levels in the department stores and hospitals than other places, indicating that the effects of indoor sources for these pollutants are significantly different from other combustion related pollutants such as TSP, CO, and $SO_2$. It was also found that there are marked seasonal and daily variations both in indoor and outdoor air quality. In general, combustion related pollutants such as CO, $SO_2$ and $NO_2$ showed a typical pattern of higher levels in winter than insummer, and also higher in the morning and/or in the evening than in the afternoon. However, the seasonal and daily patterns of HCHO appeared to be opposite to the combustion related pollutants, i.e., higher both in summer and in the afternoon, implying the effect of temperature on the volatilization from indoor sources of HCHO. Results of correlation analyses between indoor and outdoor air quality also indicated that the effects of outdoor sources on the indoor levels of TSP, $SO_2$, CO, and $NO_2$ and much significant, whilst no significant correlations between indoor and outdoor levels were found for HCHO and $CO_2$.

  • PDF

Air Pollution Exposure and Cardiovascular Disease

  • Lee, Byeong-Jae;Kim, Bumseok;Lee, Kyuhong
    • Toxicological Research
    • /
    • 제30권2호
    • /
    • pp.71-75
    • /
    • 2014
  • Ambient air pollution (AAP) and particulate matters (PM) have been closely associated with adverse health effects such as respiratory disease and cardiovascular diseases. Previous studies have examined the adverse health effects associated with short- and long-term exposure to AAP and outdoor PM on respiratory disease. However, the effect of PM size ($PM_{2.5}$ and $PM_{10}$) on cardiovascular disease has not been well studied. Thus, it remains unclear how the size of the inhalable particles (coarse, fine, or ultrafine) affects mortality and morbidity. Airborne PM concentrations are commonly used for ambient air quality management worldwide, owing to the known effects on cardiorespiratory health. In this article, we assess the relationship between cardiovascular diseases and PM, with a particular focus on PM size. We discuss the association of $PM_{2.5}$ and $PM_{10}$, nitrogen dioxide ($NO_2$), and elemental carbon with mortality and morbidity due to cardiovascular diseases, stroke, and altered blood pressure, based on epidemiological studies. In addition, we provide evidence that the adverse health effects of AAP and PM are more pronounced among the elderly, children, and people with preexisting cardiovascular and respiratory conditions. Finally, we critically summarize the literature pertaining to cardiovascular diseases, including atherosclerosis and stroke, and introduce potential studies to better understand the health significance of AAP and PM on cardiovascular disease.

공기 중 석면농도 분석시 관상어용 기포발생기를 개조한 장치와 기존의 상업용 시료 채취기와의 성능 비교 (Comparison of the Efficiency between a Remodeled Bubble Generating Pumps for an Aquarium Fish and the Existed Commercial Air Sampler for the Sampling of Ambient Air Asbestos)

  • 장봉기;탁현욱;송수진;조봉현;김영지;손부순;이종화
    • 한국산업보건학회지
    • /
    • 제24권4호
    • /
    • pp.492-500
    • /
    • 2014
  • Objectives: The purpose of this study is to estimate the applicability of regional sample collection of environmental samples. The concentration of asbestos fibers were analyzed with two devices. One was an existing commercial air sampling pump that has been proved to be accurate and exact, and the other is a remodeled pump for sample collection which was made from an electric bubble generator originally designed for aquarium fish. Samples were collected with the two devices under the same environmental conditions and collection equipment. A comparative analysis of the concentration of ambient asbestos fiber was then performed. Methods: Based on previous research, six farmhouses with asbestos fiber slate roofs known to have high concentrations of asbestos fiber were selected. Using the existing commercial air sampling pump and the remodeled electric bubble generator, four to seven samples were collected each day one meter downwind from the edge of the slate roof at high volume (about 4 L/min) and low volume (about 1.4 L/min). The analyzer responsible for sample quality control of asbestos fibers counted the number of asbestos fibers with a phase microscope. Results: The rates of flow change of the existed sampler and the remodeled pump at high volume were 0.82% and 0.17%, respectively. The rates of flow change at low volume were 3.83% and 1.09%, but there was not significant difference. The rates of flow change are within the error range (${\pm}5%$) of OSHA analyzing methods. For the high volume sampler, the average asbestos fiber concentration in the air collected by the existed sampler is 6.270 fibers/L and for the remodeled one 5.527 fibers/L, not a significant difference. For the low volume sampler, the average asbestos fiber concentration in the air collected by the existed sampler is 7.755 fibers/L and for the remodeled one 7.706 fibers/L, not a significant difference. The total area of the slate roof of the targeted farmhouse has an effect on the concentration of asbestos fibers in the air from the existing pump and the remodeled one (p<0.01). Conclusions: The sampling function between the existing commercial pump and the remodeled one shows little difference. Therefore, the remodeled pump is considered a pump with a good availability for collecting ambient air asbestos samples.

입자상 오염물질의 대기환경기준에 관한 비교연구 (A Comparative Study on Ambient Air Quality Standards for Particulate Matters)

  • 허정숙;남보현;김동술
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 1999년도 추계학술대회 논문집
    • /
    • pp.353-354
    • /
    • 1999
  • 입자상물질에 관한 초기연구는 TSP (Total Suspended Particle)에 집중되었으나, TSP만으로는 인체에 미치는 영향이나 시정악화 같은 현상을 정확하게 설명한 수 없었다. 보건학적 관점에서, PM10과 사망률사이에 강한 상관관계가 있는 것으로 조사된 바 있으며 (Pope et al, 1995), 특히 PM10 중에서 미세입자 (PM2.5미만)는 인체에 미치는 영향이 더욱 큰 것으로 알려지고 있다 (Joel et al., 1996). 이에 따라 입자상 물질의 규제 관리는 미세입자 측면에서 강화될 필요가 있다.(중략)

  • PDF

광주 지역 분진의 질량 농도와 에어러솔의 광학적 깊이 분포 : 2000년-2002년 황사를 중심으로 (Variation of Aerosol Mass Concentration and Aerosol Optical Depth during Asian Dust Events, 2000~2002 at Gwangju, Korea)

  • 김정은;류성윤;;이권호;김영준
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2002년도 추계학술대회 논문집
    • /
    • pp.271-272
    • /
    • 2002
  • 현재 우리나라에서는 PM10이 분진 측정 항목으로 대변되고 있으나 미세 영역에 해당하는 PM2.5나 PM1.0의 범위의 측정에 관심이 집중되고 있다. 미세 영역의 분진은 많은 양이 호흡기에 침착되거나 시정의 감쇄를 야기 시킨다 (Eldering and Cass, 1996 : Anderson et al., 1992). 미국 National Ambient Air Quality Standard (NAAQS)는 1997년 PM2.5 항목의 추가를 공표하였다. (중략)

  • PDF

수원지역 입자상 오염물질의 오염원 기여도의 추정 (Estimation of Source Contribution for Ambient Particulate Matters in Suwon Area)

  • 이태정;김동술
    • 한국대기환경학회지
    • /
    • 제13권4호
    • /
    • pp.285-296
    • /
    • 1997
  • The suspended particulate matters had been collected on quartz fiber fiters by a cascade impactor having 9 size stages for 4 years (Sep. 1991 to Dec. 1995) in Kyung Hee University-Suwon Campus. Membrane filters were used to collected the particulate matters on each stage. The weight concentration on each stage was obtained by a microbalance and further chemical element levels were determined by an x-ray fluorescence system. Based on these chemical information, our study focused on applying the target transformation factor analysis (TTFA), a receptor model, to identify aerosol sources and to apportion quantitatively their mass contribution. There are total of 63 ambient data sets. Each data set consists of the 8 size-ranged subdata sets characterized by 16 elemental variables. By the results, four to five sources were extracted from each size range and some sources reappeared in other size ranges. Then total of 8 source profiles were statistically generated from all the ranges, such as oil burning source, soil source, field burning source, gasoline related source, coal burning source, marine source, glass related source, and unknown sources. Apportioning aerosol mass to each source was intensively examined by investigating emission inventories near the study area. The results showed that soil particle source was the most significant contributor. However, coal and oil burning sources were the major anthropogenic ones. The study finally proposed some air quality control strategies to achieve the clean air quality in Suwon area.

  • PDF

오존 대기 환경기준의 비교 연구 (A Comparative study on Ambient Air Quality Standard for Ozone)

  • 허정숙;김태오;김동술
    • 한국대기환경학회지
    • /
    • 제15권2호
    • /
    • pp.159-173
    • /
    • 1999
  • Based on air quality monitoring data('89~'97) operated by the Department of Environment, we provide various fundamental statistics for ground ozone. The purpose of this paper are to review the national ambient ozone standard, to study spatial distribution of ozone. Since we, in Korea, calculate average ozone level, to examine the occurrences of ozone level 3 times a day (1~8, 9~16, 17~24 hours), the method does not seem to be scientifically sound comparing to a running average method adapted by the USEPA. When we counted the number of cases with 8-h average O3 level exceeding 60ppb(8-h average standard in Korea)and 80 ppb (that in the U.S.A) and also when we calculated 8-hour average ozone level based on th US method, some regions were classified as non-attainment areas. Especially in Seoul, results of spatial distribution analysis showed that high level ozone over 80 ppb was observed at Kuui-Dong and Pangi-Dong in the eastern part and at Ssangmun-Dong in the northeastern part. Also, occurrences of ozone episode defined as number of days then ozone level exceeding 80 ppb for 3 consecutive hours were extensively reviewed in this paper.