• Title/Summary/Keyword: Ambient air quality

Search Result 293, Processing Time 0.025 seconds

Distribution Characteristics of the Concentration of Ambient PM-10 and PM-2.5 in Daegu Area (대구지역 대기 중 PM-10과 PM-2.5의 농도분포 특성)

  • Do, Hwa-Seok;Choi, Su-Jin;Park, Min-Sook;Lim, Jong-Ki;Kwon, Jong-Dae;Kim, Eun-Kyung;Song, Hee-Bong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.1
    • /
    • pp.20-28
    • /
    • 2014
  • The three air quality monitoring sites, analysed simultaneously PM-10 and PM-2.5, ie. Ihyeondong in industrial area, Manchondong in residential area, Pyeongnidong in streetside, among 13 air quality monitoring sites in Daegu area, were investigated the concentration distribution characteristics of PM-2.5 and PM-10 in the last 2 years (2011~2012). PM-10 concentrations exceeded annual average reference value ($50{\mu}g/m^3$) in Ihyeondong ($52.5{\mu}g/m^3$) and Pyeongnidong ($60.9{\mu}g/m^3$) but satisfied in Manchondong ($44.9{\mu}g/m^3$). All PM-2.5 concentrations exceeded EPA annual standard value of the United States ($15{\mu}g/m^3$) in three points, but also exceeded new control annual standard value ($25{\mu}g/m^3$) coming into effect in 2015. Seasonal concentration of PM-10 appeared the order of spring > winter > fall > summer, and in the case of PM-2.5, the order was winter > spring > fall > summer. Monthly concentrations of PM-10 and PM-2.5 were highest in February and lowest in September. Diurnal concentrations of PM-10 and PM-2.5 increased from 7:00 AM, and recorded the highest concentration between 10:00 AM and 11:00 AM. And after 6:00 PM it lowered continuously and tended to show fixed concentrations from evening until early morning. In addition, the concentration of fine particles during the week was higher than the weekend. The fluctuation in industrial area was larger than the residential area. At the PM-2.5/PM-10 ratio, summer was generally high, spring was the lowest. And, when yellow sand occurred, it was 0.32 to 0.42. It was very low compared to 0.54 to 0.64 during non-yellow sand times. This paper for the state and the characteristics of Daegu' fine particles (PM-10, PM-2.5) will be valuable to future researches of fine particles and air pollution management.

Characterization of Annual PM2.5 and PM10 Concentrations by Real-time Measurements in Cheonan, Chungnam (실시간 측정을 통한 천안시 대기 중 연간 PM2.5, PM10 농도 특성 조사)

  • Heo, Jung-Hyuk;Oh, Se-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.1
    • /
    • pp.445-450
    • /
    • 2012
  • From 2015, PM2.5 standards will be added to Korean national ambient air quality standards. To characterize PM2.5 levels in Cheonan, annual PM2.5 concentrations along with PM10 concentrations were investigated between February 2010 and January 2011 using a dust monitor. The annual PM2.5 concentration was $40.45{\mu}g/m^3$ and over the standards($25{\mu}g/m^3$). The daily average PM2.5 concentrations ranged from 2.43 to $178.84{\mu}g/m^3$, and 26% days exceeded the daily PM2.5 standard($50{\mu}g/m^3$). During the same periods, only 11% days exceeded the daily PM10 standard, showing that PM2.5 were more concerning levels than PM10. Seasonal variations showed the highest concentrations in spring and winter, and lowest concentration in summer due to heavy rain fall. Changes in PM2.5 concentrations during the day were remarkable and showed the highest concentrations in commuting periods. The results indicated that the concentrations of PM2.5 in Cheonan were at the concerning level, and mainly from the mobile sources.

Energy Expenditure in Crossbred Cattle Fed Paddy Straw of Different Form

  • Bhatta, Raghavendra;Kumar, Vijay;Sridhar, Manpal;Singh, Khub
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.19 no.12
    • /
    • pp.1755-1760
    • /
    • 2006
  • Studies were carried out at the National Institute of Animal Nutrition and Physiology, India to determine the effect of feeding chopped paddy straw (Oryza sativa) on the energy expenditure in crossbred cattle. Four crossbred cattle male, aged 5-6 years and weighing about 450 kg were used for this study. Three experimental trials, one each for the feeding of un-chopped paddy straw offered ad libitum (UCA), chopped paddy straw fed at restricted level (CR) and chopped paddy straw offered ad libitum (CA) were conducted. The quantity of un-chopped paddy straw consumed during UCA was assumed as the voluntary intake by the cattle and the same quantity was offered after chopping during CR. Each trial comprised of 21 d preliminary feeding period and 5 d of observation recording period. Expired gas was collected in Douglas bags using a face-mask and three-way valve at 6 hourly intervals i.e., at 09.30, 15.30, 21.30, and 03.30 h throughout the observation period. Expired gas and ambient air inspired by the animals were analyzed for the oxygen content through paramagnetic oxygen analyzer. Energy expenditure (EE) by the animals was calculated by determining the volume of oxygen consumed per minute (STP) and multiplying by 4.825. Paddy straw used in all the three trials contained (g/kg DM) 90.0 CP, 786 OM, 700 NDF, 489 ADF, 357 Cellulose and 60.0 ADL. Metabolizable energy (ME) was 6.9 MJ/kg DM. Dry matter intake (DMI) both in UCA and CR was about 6.8 kg, except that it was chopped in CR. Chopping has resulted in 32% improvement (9 kg) in DMI of CA as compared to that of UCA. Although ME intake was similar in UCA and CR (47.2 MJ/day), energy expenditure (EE) was higher in UCA (23.3 MJ) when compared to that of CR (19.5 MJ). The ME intake (63.3 MJ) as well as EE (27.1 MJ) was highest in CA. Energy expenditure when expressed as MJ/kg DMI was 3.48, 2.90 and 3.12; whereas as per cent of ME intake it was 50, 41 and 44 in UCA, CR and CA respectively. Our study has unequivocally confirmed that chopping of poor quality roughages like paddy straw has definite advantages not only in terms of improving the intake by decreasing the time taken for ingestion but also in reducing the energy cost of eating.

Large-Area Synthesis of High-Quality Graphene Films with Controllable Thickness by Rapid Thermal Annealing

  • Chu, Jae Hwan;Kwak, Jinsung;Kwon, Tae-Yang;Park, Soon-Dong;Go, Heungseok;Kim, Sung Youb;Park, Kibog;Kang, Seoktae;Kwon, Soon-Yong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.130.2-130.2
    • /
    • 2013
  • Today, chemical vapor deposition (CVD) of hydrocarbon gases has been demonstrated as an attractive method to synthesize large-area graphene layers. However, special care should be taken to precisely control the resulting graphene layers in CVD due to its sensitivity to various process parameters. Therefore, a facile synthesis to grow graphene layers with high controllability will have great advantages for scalable practical applications. In order to simplify and create efficiency in graphene synthesis, the graphene growth by thermal annealing process has been discussed by several groups. However, the study on growth mechanism and the detailed structural and optoelectronic properties in the resulting graphene films have not been reported yet, which will be of particular interest to explore for the practical application of graphene. In this study, we report the growth of few-layer, large-area graphene films using rapid thermal annealing (RTA) without the use of intentional carbon-containing precursor. The instability of nickel films in air facilitates the spontaneous formation of ultrathin (<2~3 nm) carbon- and oxygen-containing compounds on a nickel surface and high-temperature annealing of the nickel samples results in the formation of few-layer graphene films with high crystallinity. From annealing temperature and ambient studies during RTA, it was found that the evaporation of oxygen atoms from the surface is the dominant factor affecting the formation of graphene films. The thickness of the graphene layers is strongly dependent on the RTA temperature and time and the resulting films have a limited thickness less than 2 nm even for an extended RTA time. The transferred films have a low sheet resistance of ~380 ${\Omega}/sq$, with ~93% optical transparency. This simple and potentially inexpensive method of synthesizing novel 2-dimensional carbon films offers a wide choice of graphene films for various potential applications.

  • PDF

Preparation and characterization of Environmental Functional Nanofibers by electrospun nanofibers-Dry sorption material for indoor CO2 capture (정전방사를 통한 환경기능성 미세섬유 제조 및 특성분석 - 실내환경 CO2 포집용 건식흡착소재)

  • Kim, Eun Joo;Park, Kyung-Ryul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.938-943
    • /
    • 2018
  • Thin nano-sized fibres were prepared by an electrospinning method. The spinning appratus consisted of pump for polymer injection, nozzle and nozzle rotus, and an aluminum plate collected the polymer fibers. Its surface was chemically modified for selective improved adsorption of carbon monoxide at indoor level. The chemical activation enabled to form the fibres 250-350 nm in thickness with pore sizes distributed between 0.6 and 0.7 nm and an average specific surface area of $569m^2/g$. The adsorption capacities of pure (100%) and indoor (0.3%) $CO_2$, of which level frequently appears, at the ambient condition were improved from 1.08 and 0.013 to 2.2 and 0.144 mmol/g, respectively. It was found that the adsorption amount of $CO_2$ adsorbed by the chemically activated carbon nanofiber prepared through chemical activation would vary depending on the ratio of specific surface area and micropores. In particular, chemical interaction between adsorbent surface and gas molecules could enhance the selective capture of weak acidic $CO_2$.

Indoor and Outdoor Levels of Particulate Matter with a Focus on I/O Ratio Observations: Based on Literature Review in Various Environments and Observations at Two Elementary Schools in Busan and Pyeongtaek, South Korea (실내 외 농도 비(I/O ratio)에 기반한 주변환경과 실내 미세먼지 농도분포 특성: 선행연구 리뷰와 여름철 부산과 평택 초등학교에서의 측정 결과를 중심으로)

  • Kang, Jiwon;An, ChanJung;Choi, Wonsik
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.6_3
    • /
    • pp.1691-1710
    • /
    • 2020
  • We measured PM2.5 and PM10 (particulate matter less than 2.5 ㎛ and 10 ㎛ in diameter, respectively) simultaneously at 16 locations around an elementary school and classrooms in Busan and Pyeongtaek, South Korea. In this study, we compared the results of this field intensive with those in the literature (144 cases of 30 studies), focusing on I/O (Indoor/Outdoor) ratios. We also reviewed the results of previous studies, categorizing them into related sub-categories for indoor-activities, seasons, building-uses, and the surrounding environment. We conclude that indoor PM10 is affected more by indoor-sources (e.g., physical activities) than PM2.5 in the absence of combustion sources like smoking and cooking. Additionally, PM10 and PM2.5 likely have different indoor-outdoor infiltration efficiencies. Conclusively, PM10 in classrooms can be more sensitively affected by both indoor activities and ambient concentrations, and mechanical ventilation can be more efficient in reducing PM concentrations than natural ventilation.

Quality characteristics of rice noodles treated with cold plasma (저온 플라즈마 처리한 쌀국수의 품질 특성)

  • Kim, Hyun-Joo;Lee, Byong Won;Baek, Ki Ho;Jo, Cheorun;Kim, Jae-Kyung;Lee, Jin Young;Lee, Yu-Young;Kim, Min Young;Kim, Mi Hyang;Lee, Byoungkyu
    • Korean Journal of Food Science and Technology
    • /
    • v.52 no.5
    • /
    • pp.560-563
    • /
    • 2020
  • Cold plasma has been applied to improve quality of food product; however, studies on its effects on microbial and physicochemical qualities of rice noodles are rarely conducted. In this study, changes in the quality characteristics of rice noodles treated by cold plasma were determined. Cold plasma was generated in a square-shaped plastic container (250 W, 15 kHz, ambient air), and dielectric barrier discharge plasma treatments were applied to rice noodle samples for 0, 10, or 20 min. Rice noodles inoculated with either Bacillus cereus or Escherichia coli O157:H7 were subjected to plasma treatment for 20 min, and the approximate bacterial count reduction were 4.10 and 2.75 log CFU/g, respectively. The Hunter color values of the sample were increased after cold plasma treatment. Peroxide values and thiobarbituric acid reactive substance (TBARS) were increased with an increase in cold plasma treatment time. Futhermore, lipid oxidation was enhanced. Although further studies are warranted to evaluate changes in chemical qualities, such as lipid oxidation of rice noodles, induced by cold plasma, the results suggest that cold plasma can improve the microbial and physical qualities of rice noodles.

Effect of Atmospheric Pressure Plasma on the Quality of Commercially Available Sunsik (대기압 플라즈마가 선식의 품질 특성에 미치는 영향)

  • Kim, Hyun-Joo;Woo, Koan Sik;Jo, Cheorun;Lee, Seuk Ki;Park, Hye Young;Sim, Eun-Yeong;Won, Yong-Jae;Lee, Sang-Bok;Oh, Sea-Kwan
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.5
    • /
    • pp.375-379
    • /
    • 2016
  • Atmospheric pressure plasma (APP) was applied to examine microbial safety and qualities of commercial Sunsik. APP was generated in a square-shaped plastic container (250 W, 15 kHz, ambient air) and dielectric barrier discharge plasma treatment was applied for periods of 0, 5, 10, and 20 minutes. The total aerobic bacterial count in the control was 4.44 log CFU/g. Under plasma treatment for 20 minutes, Sunsik samples inoculated with Bacillus cereus, B. subtilis, and Escherichia coli O157:H7 resulted in a reduction of bacterial counts by approximately 2.20, 2.22, and 2.52 log CFU/g, respectively. The pH of the sample was found to decrease after APP treatment. Although hunter color $L^*$ of Sunsik increased, $a^*$ and $b^*$ value decreased as a result of APP. Increasing the APP time also enhanced the peroxide value. Further, sensory evaluation revealed that APP decreased color, flavor, taste and overall acceptability. The results of this study indicated that APP treatment improved the microbial quality of Sunsik, although further studies should be conducted to reduce the deterioration of sensory quality induced by APP.

Growth of Cucumber and Tomato Seedlings by Different Light Intensities and CO2 Concentrations in Closed-type Plant Production System (밀폐형 식물생산시스템 내 CO2와 광도에 따른 오이 및 토마토 묘의 생육)

  • Ji Hye Yun;Hyeon Woo Jeong;So Yeong Hwang;Jin Yu;Hee Sung Hwang;Seung Jae Hwang
    • Journal of Bio-Environment Control
    • /
    • v.32 no.4
    • /
    • pp.257-266
    • /
    • 2023
  • This study was conducted to investigate the growth characteristics of cucumber (Cucumis sativus L. 'Joeunbaekdadagi') and tomato (Solanum lycopersicum L. 'Dotaerang Dia') seedlings by light intensities and CO2 concentrations in a closed-type plant production system (CPPS). Cucumber and tomato seeds were sown in 50-cell trays and germinated in CPPS at air temperature 25 ± 1℃ and relative humidity 50 ± 10% for 4 days. After germination, the CO2 concentrations and light intensity treatment were treated at 500 (ambient), 1,000, and 1,500 µmol·mol-1 and 100, 200, and 300 µmol·m-2·s-1 photosynthetic photon flux density (PPFD), respectively. The leaf area of cucumber showed the highest value in CO2 1,500 μmol·mol-1. However, the leaf area of the tomato had no significant difference in CO2 concentrations and light intensities treatments. In cucumber and tomato both seedlings, the growth and quality such as compactness and leaf area rate were increased with the increase of light intensity, and there were highest in 300 µmol·m-2·s-1. The root surface and number of root tips of cucumber and tomato seedlings were significantly increased with the increase in light intensity. In conclusion, the regulation of the CO2 concentrations and light intensity can control the growth and quality of cucumber and tomato seedlings in CPPS, especially, increasing the light intensity can improve more significantly the growth and quality of seedlings.

Characteristics of PM2.5 and PM10 Concentration in Pusan Area (부산지역 PM2.5와 PM10의 농도 특성)

  • Kim, Sang-Youl;Cheong, Jang-Pyo;Yi, Seung-Muk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.6
    • /
    • pp.1159-1170
    • /
    • 2000
  • It is necessary to improve the ambient air quality through the proper treatment and control of pollutants by designating air pollutants to regulatory ones. Especially, human took a concern for particulate matters which raised visibility reduction, public health effects and injury of property for urban areas. In order to reduce the effect of particulate matters, we need to establish proper control strategies based on the concentration characteristics of particulate matters. In this study. to evaluate the characteristics of $PM_{2.5}$ and $PM_{10}$. thirty-eight samples of $PM_{2.5}$ and $PM_{10}$ were collected at Nam-Gu sampling site where continuous air monitoring system has been operated, from May, 1999 to November, 1999, and their concentrations for the mass and anion components($Cl^-$, $NO_3{^-}$, $SO_4{^{2-}}$) were analyzed. The important conclusions obtained in this study were as followings. Total average mass concentrations of $PM_{2.5}$ and $PM_{10}$ were 35.016 and $50.293{\mu}g/m^3$ respectively. and $PM_{2.5}/PM_{10}$ ratio was calculated 0.692. Total average concentrations of anion components in $PM_{2.5}$ were $1.581(Cl^-)$, $3.690(NO_3{^-})$ and $12.825(SO_4{^{2-}}){\mu}g/m^3$ and those in $PM_{10}$ were $2.471(Cl^-)$, $5.819(NO_3{^-})$ and $14.414(SO_4{^{2-}}){\mu}g/m^3$ respectively. From the correlations analysis. the correlation coefficient between mass concentration of $PM_{2.5}$ and $PM_{10}$ was calculated as 0.945. The correlation coefficients between $PM_{2.5}$ and anion components were analyzed as $Cl^-$(0.025), $NO_3{^-}$(0.788) and $SO_4{^{2-}}$(0.500) respectively, and the correlation coefficients between $PM_{10}$ and anion components were analyzed as $Cl^-$(-0.019), $NO_3{^-}$(0.806) and $SO_4{^{2-}}$)(0.535) respectively.

  • PDF