• Title/Summary/Keyword: Ambient Environment

Search Result 1,167, Processing Time 0.026 seconds

Spatial Analysis of Ambient Air Quality Using GIS

  • Choi, Byoung-Gil;Lee, Hee-Kwan;Ra, Young-Woo
    • Korean Journal of Geomatics
    • /
    • v.2 no.2
    • /
    • pp.145-151
    • /
    • 2002
  • GIS technique is applied to the analysis of ambient air quality information. For this study, the TMS-monitored air quality information was imported with the geographical information of the TMS stations in Capital Area. It is found that currently available GIS technique has a great extend of potential for air quality management. From the analysis of air quality information, the GIS application demonstrates the poor air quality in the central Capital Area and the it is improved as it travels down to the suburb area. The ambient air quality is also proven to be highly influenced by the ozone concentration in a mid-summer day.

  • PDF

Quality Control(QC) Analysis of Ambient VOCs in Canisters Using GC/MSD Method (Canister와 GC/MSD를 이용한 대기 중 VOCs 분석시스템의 정도관리(QC))

  • Jeon, Jun-Min;Hur, Dang;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.6
    • /
    • pp.527-538
    • /
    • 2002
  • In this study, the performance of sampling and of analytical methodology was examined against a number of selected volatile organic compounds (VOCs) in the ambient air. The canister-based sampling method for VOCs has been a viable and widely used approach that is based on research and evaluation performed over the past several years. VOCs were determined using canisters by GCMSD analysis. A total of target analyses in this study included approximately 30 VOCs designated in TO-l4A categories including BTEX. The methodology for QC(quality control) was intensively investigated with a wide range of performance criteria such as; (1) cleanliness of canisters, (2) reproducibility of diluter, (3) instrumental detection limits of preconcentrator and GCMSD, and (4) precision and accuracy of GCMSD. For most of the compounds tested, precision was less than $\pm$5%, IDL was 0.2 ppbv, accuracy was $\pm$5%, respectively. This study demonstrated that the combination of canister sampling and GC/MSD analysis could be reliably applied to the measurements of BTEX in ppbv levels that are typically observed in/outdoor air environment.

Study on Vaporization and Combustion of Spray in High Pressure Environment (고압에서의 분무의 증발 및 연소 현상에 관한 연구)

  • Wang, Tae-Joong;Baek, Seung-Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.9
    • /
    • pp.1273-1281
    • /
    • 2003
  • The present study is mainly motivated to investigate the vaporization, auto-ignition, and combustion of liquid fuel spray injected into high pressure environment. The unsteady, multi-dimensional models were used for realistic simulation of spray as well as prediction of accurate ignition delay time. The Separated Flow (SF) model which considers the finite rate of transport between liquid and gas phases was employed to represent the interactions between spray and gas field. Among the SF models, the Discrete Droplet Model (DDM) which simulates the spray using finite number of representative samples of discrete droplets was adopted. The Eulerian-Lagrangian formulation was used to analyze the two-phase interactions. In order to predict an evaporation rate of droplet in high pressure environment, the high pressure vaporization model was applied using thermodynamic equilibrium and phase equilibrium at droplet surface. The high pressure effect as well as high temperature effect was considered in the calculation of liquid and gas properties. In case of vaporization, an interaction between droplets was studied through the simulation of spray. The interaction is shown up differently whether the ambient gas field is at normal pressure or high pressure. Also, the characteristics of spray behavior in high pressure environment were investigated through the comparison with normal ambient pressure case. In both cases, the spray behaviors are simulated through the distributions of temperature and reaction rate in gas field.

Concentrations of $C_2$~$C_9$ Volatile Organic Compounds in Ambient Air in Seoul (서울 대기 중에서 $C_2$~$C_9$ 휘발성 유기화합물의 농도)

  • Na, Gwang-Sam;Kim, Yong-Pyo;Kim, Yeong-Seong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.2
    • /
    • pp.95-106
    • /
    • 1998
  • Volatile organic compounds (VOCs) from Ca to C9 were investigated with nine ambient air samples collected in April 26, August 17, 1996 and January 23, 1997 in a Seoul site. On each sampling day, three 2-hr integrated canister samples were collected in early morning, early afternoon and late afternoon, respectively to study temporal . variation of VOCs. Most of VOC species showed diurnal variation with higher concentrations in the early morning and lower concentrations in the afternoon. The concentrations of light alkanes were high, probably due to the emission from liquefied petroleum gas (LPG) and evaporation of gasoline. Especially, the concentration of propane was the highest in the morning samples. The concentrations of propane, ethylene, acetylene, and toluene were prominent in their hydrocarbon groups, respectively. These components were the main source of car exhaust, gasoline evaporization, LPG, or solvent usage.

  • PDF

Characteristics of Ambient Metals: Size Segregated Ambient Concentrations and Dry Deposition Fluxes at Four Sites in Kunpo in 2000

  • Kim, Yong-Pyo;Yun, Hui-Jung;Yi, Seung-Muk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.E2
    • /
    • pp.57-68
    • /
    • 2002
  • Atmospheric dry deposition fluxes and size segregated concentrations of particulate metal elements were measured at four sites in Kunpo, a small city in the Seoul metropolitan area in Korea. At each site, aerosol samples were collected by dry deposition plates, a cascade impactor, and a coarse panicle rotary impactor during four sampling periods. At all sites, the average fluxes of metals measured during daytime were higher than nighttime fluxes due to higher wind speeds and higher ambient concentrations during daytime. The average fluxes of crustal elements (Al, Ca) were 1∼2 orders of magnitude higher than anthropogenic elements (As, Cd, Cu, Mn, Ni, Pb, and Zn). The daytime fluxes of Al and Ca were between 90 and 12000 $\mu\textrm{g}$ m$\^$-2/ day$\^$-1/, and the nighttime fluxes of Al and Ca were between 20 and 2200 $\mu\textrm{g}$ m$\^$-2/ day$\^$-1/. The daytime fluxes of Pb, a typical anthropogenic element, were between 20 and 160$\mu\textrm{g}$ m$\^$-2/ day$\^$-1/, and the nighttime fluxes of Pb were between ND and 100$\mu\textrm{g}$ m$\^$-2/ day$\^$-1/. Also the ambient metal concentrations during daytime were higher than nighttime. Based on a dust emission estimation study in Kunpo, it was found that dust emissions during daytime are higher than nighttime. The concentrations of crustal elements were higher than anthropogenic elements. The distributions of heavy metals were mainly in small particles (D$\_$p/ 9㎛). The fraction of crustal elements in the large particles (D$\_$p/> 9㎛) were higher than anthropogenic elements.

Measurement of Volatile Organic Sulfur Compounds in Ambient Air by Canister and Tedlar-bag Sampling Method (캐니스터와 Tedlar-bag 시료채집법을 이용한 대기 중의 휘발성유기황화합물의 측정)

  • 전선주;허귀석
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.4
    • /
    • pp.417-428
    • /
    • 1999
  • The measurement of VOSCs(volatile organic sulfur compounds) in the air is nowadays a very important environmental research field. It is, however, very difficult because the concentration of the VOSC in ambient air is usually very low and the high reactivity makes it difficult to keep in container without loss of recovery. In this study, sampling method with cryogenic preconcentration is evaluated for analysis of atmospheric VOSC such as $CH_3SH,\;CH_3CH_2SH,\;CH_3SCH_3,\;CS_2,\;CH_3SSCH_3,\;CH_3SCH_2SCHA_3,\;and\;C_2H_5SSC_2H_5$ analyzed by GC-MS or GC-FID. Repeatabilities of measurement accompanied with preconcentration for 3-successive runs were in the range of 0.2~1.0% as a relative standard deviation. Stabilities up to 13 days were measured in 6 L canister and 10 L tedlar bag filled with VOSCs in ppb level. Higher stability was observed in tedlar bag as compared to canister with glass coated inner walls, and thiol compounds show dramatic losses in canister within 2~3 days. It is found that recovery over 70% was obtained in a week for all tested VOSCs when the compounds from ambient air matrix were stored in tedlar bag. It is also found that the stabilities of VOSCs are depending on humidity and coexisting compounds in matrix gas due to sample adsorption onto inner surface and reactivity. The results indicate the possibility and limitations of VOSC analysis in ambient air using container sampling method with cryogenic preconcentration.

  • PDF

Effect of Forced-air circulation of ambient Fruit on the Occurrence Fermented-fruit and Fruit Quality of Oriental Melon(Cucumis melo L. var. makuwa Mak.) (과실부위 송풍이 참외의 품질 및 발효과 발생에 미치는 영향)

  • 연일권;최성국;최부술;신용습
    • Journal of Bio-Environment Control
    • /
    • v.8 no.2
    • /
    • pp.99-107
    • /
    • 1999
  • The experiment was conducted to investigate the relationship between $Ca^{2+}$ uptake and development of fermented fruit through the forced-air circulation of ambient fruit. Air circulation of ambient fruits were adjusted with 0.3m/sec wind velocity for three hours a day from 10:00 to 13:00. Treatments consisted of 0, 10 day, 20 day, 30 day of forced air circulation of ambient fruit. Although the results varied depend on the duration forced air circulation, in general, treated fruit increased fruit weight, flesh thickness, fruit hardness, soluble solids, and chromaticity, and decreased the number of fermented-fruit. $Ca^{2+}$ content in fruit.

  • PDF

Estimation of Dynamic Characteristics of Existing Dam Floodgate Using Ambient Vibration (상시 진동을 이용한 댐 수문의 동특성 추정)

  • Kim, Nam-Gyu;Lee, Jong-Jae;Bea, Jung-Ju
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.4
    • /
    • pp.343-350
    • /
    • 2011
  • Recently, as the catastrophic disasters due to earthquake happen frequently all over the world, it draws lots of attention to seismic capacity evaluation and/or structural integrity assessment of deteriorated civil infra-structures. However, there have been few studies on the existing dam flood gates, expecially in Korea. In this study, a proper vibration testing method applicable to a dam flood gate has been suggested, since the dynamic characteristics of a darn flood gate can be fundamental data for seismic capacity evaluation or structural integrity assessment. The frequency domain decomposition technique has been incorporated for modal parameter identification. Two kinds of vibration tests using an impact hammer and ambient vibration sources were carried out on two types of dam floodgates with different shapes. Through the field tests, the effectiveness of the ambient vibration tests were verified.

Characterization of Air Quality in Various Types of Indoor Environments in Urban Areas - Focusing on Homes, Offices, and Restaurants - (도시지역 실내환경 유형별 공기질 특성 평가 -가정, 사무실 및 식당을 중심으로-)

  • 백성옥;김윤신
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.4
    • /
    • pp.343-360
    • /
    • 1998
  • In this study, comprehensive air quality monitoring was undertaken with a variety of objectives to collect data on the levels of various indoor and ambient air quality parameters in the urban areas of Seoul and Taegu. The sampling sites were comprised of six offices, six residences and six restaurants in each city. The ambient air adjacent to the indoor sites was also simultaneously sampled for the same constituents. The sampling was conducted in two phases: summer of 1994 and winter of 1994/95. A range of air quality parameters were measured simultaneously, which include RSP, CO, COB, NOB, a range of VOC, airborne microbials, temperature, and relative humidity. The indoor and ambient levels of the pollutants measured in this study varied widely between the three types of environments studied. Comparison of median values for the three groups revealed that restaurants had higher indoor levels of most pollutants than homes or offices. There was also a clear pattern of the indoor levels of target pollutants being higher than those outdoors, particularly in restaurants. Concentrations of CO and most of the VOC were found to be significantly higher in the commercial districts, indicating the influence of vehicle exhaust emissions. A very wide range of VOC levels was documented in this study. Although median indoorloutdoor ratios indicated a generally increasing level of VOC indoors when compared to those outdoors, no statistically significant differences were found between indoor and outdoor VOC levels in homes and offices, implying the importance of ambient air quality in determining the quality of indoor air for homes and offices in urban areas. In addition, there was a general pattern of increasing concentrations from summer to winter, and similarly from outdoor to indoor air for nearly all target compounds. The seasonal differences in median levels were very clearly seen for fuel combustion related pollutants such as RSP, CO and VOC, this being attributed to the effects of increased fuel consumption during the cold season and to meteorological factors.

  • PDF

Filter-based Correction for Positive Sampling Artifacts in the Determination of Ambient Organic Carbon (여과지를 이용한 유기탄소의 측정 오차 보정)

  • Kang, Byung-Wook;Yeon, Ik-Jun;Cho, Byung-Yeol;Park, Sang-Chan;Lee, Hak-Sung;Jeon, Jun-Min;Na, Kwang-Sam
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.1
    • /
    • pp.63-72
    • /
    • 2011
  • This study describes the impact of positive sampling artifact caused by a filter-based sampling in the determination of ambient organic carbon (OC). Three different sampling media combinations were employed for this investigation: (1) Quartz filter-alone (Q-alone), (2) quartz filter behind quartz-fiber filter (QBQ), and (3) quartz filter and quartz filter behind Teflon filter (Q-QBT). The measurement of ambient OC was carried out at a semi-urban site near oceanside at the end of November of 2008. It was found that Q-alone sampling configuration resulted in a higher OC than QBQ and Q-QBT by 14% and 28%, respectively due to no correction for positive artifact caused by adsorption of gas-phase OC onto the filter. A lower quantity of OC was collected from the backup quartz filter on QBQ than that from Q-QBT. A possible explanation is that the front quartz filter of QBQ was not fully saturated with gas-phase OC during the sampling period, allowing smaller amount of gas-phase OC to reach the backup quartz filter. The contribution of positive artifact to $PM_{2.5}$ mass was approximately 2.15 ${\mu}g/m^3$ which is equivalent to 6% in terms of Q-QBT sampling configuration. The positive artifact was found to be more dominated during summer than during winter, showing temperature dependence. It was concluded that Q-QBT sampling configuration offers less impact of positive artifact on ambient OC sampling than QBQ in quantification of OC.