• Title/Summary/Keyword: Ambient Environment

Search Result 1,167, Processing Time 0.026 seconds

Partial Nitritation in an SBR Reactor by Alkalinity Control (알칼리도 제어에 의한 SBR 반응조에서의 부분아질산화)

  • Lee, Chang-Kyu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.4
    • /
    • pp.294-300
    • /
    • 2013
  • In this study, major parameter of partial nitritation was investigated for the stable operation. In order to establish partial nitritation system, prevailing parameters such as temperature, BA (bicarbonate alkalinity) and pH were evaluated. As a result, it is inferred that appropriate bicarbonate alkalinity ratio (mg $NaHCO_3{\cdot}L^{-1}/mg$ Inf. $NH_4{^+}-N{\cdot}L^{-1}$) drives stable 50% partial nitritation at $32^{\circ}C$ and ambient temperature, respectively. Alkalinity ratio was proposed as new strategy for 50% partial nitritation without pH control in both temperature regimes. Because of the results, it was added amound of BA required only for 50% nitritation to inhibit nitratation. The effluent $NO_2{^-}-N/NH_4{^+}-N$ ratio reached almost 100% when initial bicarbonate alkalinity ratios (mg $NaHCO_3{\cdot}L^{-1}/mg$ Inf. $NH_4{^+}-N{\cdot}L^{-1}$) were 6.8 (R1) and 6.7 (R2), respectively. Polymerase chain reaction and denaturing gradient gel electrophoresis (PCR-DGGE) results demonstrated that AOB was the dominant nitrifying bacteria and NOB was negligible after adopting process control.

A Study on the Test and Installation Standards of the Video Fire Detector (영상화재감지기 시험과 설치기준에 관한 연구)

  • Lee, Jeong-Hyun;Baek, Dong-Hyun
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.1-5
    • /
    • 2016
  • This research performed tests of Video Fire Detector and criteria of installation to make suggestions regarding the criteria that must be reflected in NFSC 203 by comparing the standards of FM Approvals, UL, ISO7240 and NFPA 72. FM Standard related to Video Fire Detector test has been classified as Smoke, Flame type, but the UL Standard has classified only as a Smoke type. This research examined 6 cases of fire phenomenon detection case in ISO 7240 and 3 cases in NFPA 72, respectively. There are 15 items required for the installation standard of a Video Fire Detector and each field standard is presented as a per installation method. To apply a Video Fire Detector, the pertinent items (the definition of term, detector's classification, structure and function among its test item) must be inserted. In addition, 7 items of the fire test, i.e., the sensitivity adjustment, prevent false alarm, ambient temperature test, the effective sensitivity and detection distance and viewing angle, aging test, flood test, must be applied to the actual test. For installation in the field, the operation environment and levels of illumination, and NFSC 203 must be set, and standards relevant to the sound system, indicators' installation distance, etc. need to be inserted.

Motility and Chemotaxis in the Lyme Spirochete Borrelia burgdorferi: Role in Pathogenesis (라임병 원인 스피로헤타 Borrelia burgdorferi의 운동성과 주화성: 발병기전에서의 역할)

  • Yoo, Ah Young;Kang, Ho Young;Moon, Ki Hwan
    • Journal of Life Science
    • /
    • v.28 no.5
    • /
    • pp.627-637
    • /
    • 2018
  • Motility and chemotaxis are crucial for disease development in many motile pathogens, including spirochetes. In many bacteria, motility is provided by flagella rotation, which is controlled by a chemotaxis-signal-transduction system. Thus, motility and chemotaxis are inextricably linked. Spirochetes are a unique group of bacteria with distinctive flat-wave morphology and corkscrew-like locomotion. This unusual motility pattern is believed to be important for efficient motility within the dense tissues through which these spirochetes preferentially disseminate in a host. Unlike other externally flagellated bacteria-where flagella are in the ambient environment-the flagella of spirochetes are enclosed by the outer membrane and thus are called periplasmic flagella or endoflagella. Although motilityand chemotaxis-associated genes are well studied in some bacteria, the knowledge of how the spirochete achieves complex swimming and the roles of most of the putative spirochetal chemotaxis proteins are still elusive. Recently, cutting-edge imaging methods and unique genetic manipulations in spirochetes have helped to unravel the mystery of motility and chemotaxis in spirochetes. These contemporary advances in understanding the motility and chemotaxis of spirochetes in a host's persistence and disease process are highlighted in this review.

Proximate Compositions of Green Garlic Powder and Microbiological Properties of Bread with Green Garlic (풋마늘 분말의 일반성분 및 풋마늘 첨가 식빵의 미생물학적 특성)

  • Lee Mi Kyung;Park Jung Suk;Na Hwan Sik
    • Food Science and Preservation
    • /
    • v.12 no.1
    • /
    • pp.95-100
    • /
    • 2005
  • To enhance the utilization of green garlic as food materials, the nutritional and microbiological properties of green garlic powder and bread were investigated. Proximate compositions of green garlic powder were as follows; moisture $6.99\%$, crude protein $7.62\%$, crude lipid $1.84\%$, crude ash $6.60\%$, crude fiber $9.88\%$ and carbohydrate $76.95\%$. Free sugars were composed of glucose, glucose and sucrose. The major minerals of green garlic powder were k(1,140 mg/100 g), Ca(679.05 mg/100 g), P(342.09 mg/100 g) and Na(130.42 mg/100 g). In the total and free amino acid analysis, the major amino acids were methionine, cystine, proline and glutamic acid. When various amount of freeze dried green garlic powder were added in bread, bread with $0.5\%$ green garlic powder had lower level of total bacterial count compared with the control group at ambient temperature$(30{\pm}1^{\circ}C)$. Result of sensory evaluation showed that the preference scores decreased as the green garlic powder content increased. Through the result of these experiment we can conclude that the highest quality of green garlic powder content is no more than $0.5\%$ in making bread added with green garlic powder.

A study on the characteristics of fuel performance according to the oxygenated additive type for gasoline fuel Part 1. Fuel properties and evaporative emission characteristics (휘발유 연료용 함산소 첨가제 종류에 따른 성능 특성 연구 Part 1. 연료물성 및 증발가스 배출 특성)

  • Lee, Min-Ho;Kim, Jong-Ryeol;Kim, Ki-Ho;Ha, Jong-Han
    • Journal of the Korean Applied Science and Technology
    • /
    • v.33 no.1
    • /
    • pp.118-128
    • /
    • 2016
  • As the interest on the air-pollution is gradually rising up at home and abroad, automotive and fuel researchers have been working on the exhaust emission reduction from vehicles through a lot of approaches, which consist of new engine design, innovative after-treatment systems, using clean (eco-friendly alternative) fuels and fuel quality improvement. This research has brought forward two main issues : exhaust emission and PM (particulate matter) particle emissions of gasoline vehicle. Exhaust emission and PM particle of automotive had many problem that cause of ambient pollution, health effects. In addition, researcher studied the environment problems of the MTBE contained in the fuel as oxygenate additives. The researchers have many data about the health effects of ingestion of MTBE. However, the data support the conclusion that MTBE is a potential human carcinogen at high doses. Based on the oxygenated fuel additive types (MTBE, Bio-ETBE, Bio-ethanol, Bio-butanol), this paper discussed the influence of oxygen contents on gasoline fuel properties and evaporative emission characteristics. Also, this paper assessed the acceleration and power performance of gasoline vehicle for the fuel property.

Thermal Diffusivity of PEEK/SiC and PEEK/CF Composites (PEEK/SiC와 PEEK/CF 복합재료의 열확산도에 대한 연구)

  • Kim, Sung-Ryong;Yim, Seung-Won;Kim, Dae-Hoon;Lee, Sang-Hyup;Park, Joung-Man
    • Journal of Adhesion and Interface
    • /
    • v.9 no.3
    • /
    • pp.7-13
    • /
    • 2008
  • The particulate type silicon carbide (SiC) and fiber type carbon fiber (CF) filler, of similar thermal conductivities, were mixed with polyetheretherketone (PEEK) to investigate the filler effects on the thermal diffusivity. The SiC and CF fillers had a good and uniform dispersion in PEEK matrix. Thermal diffusivities of PEEK composites were measured from ambient temperature up to $200^{\circ}C$ by laser flash method. The diffusivities were decreased as increasing temperature due to the phonon scattering between PEEK-filler and filler-filler interfaces. Thermal diffusivity of PEEK composites was increased with increasing filler content and the thermal conductivities of two-phase system were compared to the experimental results and it gave ideas on the filler dispersion, orientation, aspect ratio, and filler-filler interactions. Nielson equation gave a good prediction to the experimental results of PEEK/SiC. The easy network formation by CF was found to be substantially more effective than SiC and it gave a higher thermal diffusivities of PEEK/CF than PEEK/SiC.

  • PDF

Detection of Long Period Seismic Events by Using a Portable Gravity Meter, gPhone (이동식 중력계(gPhone)를 활용한 장주기 지진 이벤트 관측)

  • Lee, Won Sang;Seo, Ki-Weon;Eom, Jooyoung;Sheen, Dong-Hoon;Lee, Choon-Ki;Park, Yongcheol;Yun, Sukyoung;Yoo, Hyun Jae
    • Geophysics and Geophysical Exploration
    • /
    • v.18 no.1
    • /
    • pp.31-34
    • /
    • 2015
  • A gravity meter has been used for exploring subsurface mineral resources and monitoring long-period events such as Earth tides. Recently, researchers found several other intriguing features that we could even detect large teleseismic earthquakes and monitor seismic ambient noise using gravimeters. The zero-length spring suspension technology gives the gPhone (Micro-g LaCoste) excellent low frequency sensitivity, which may have implications for investigating much longer-period natural events (e.g., Earth's hum, tsunami waves, etc.). In this study, we present preliminary results through temporary operation of the gPhone at Geumsan in South Korea for 9 months (Nov. 2008-Jul. 2009). The gPhone successfully recorded large teleseismic events and showed a clear seasonal variation of the Double frequency microseisms during its operation period.

Accuracy Evaluation of Bi-medium Deep Body Thermometer Based on Finite Element Simulation (유한 요소 시뮬레이션을 이용한 이중 매질 심부 체온계의 정확도 평가)

  • Sim, S.Y.;Ryou, H.S.;Kim, H.B.;Jeong, J.H.;Lee, S.J.;Kim, S.M.;Park, Kwang Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.160-168
    • /
    • 2014
  • Continuous body temperature monitoring is useful and essential in diverse medical procedures such as infection onset detection, therapeutic hypothermia, circadian rhythm monitoring, sleep disorder assessment, and gynecological research. However, the existing thermometers are too invasive or intrusive to be applied to long-term body temperature monitoring. In our previous study, we invented the bi-medium deep body thermometer which can noninvasively and continuously monitor deep tissue temperature. And the ratio of thermal resistances expressed as K-value should be obtained to estimate body temperature with the thermometer and it can be different under various measurement environments. Although the device was proven to be useful through preliminary simulation test and small group of human study, the experimental environment was restrictive in our previous approach. In this study, a finite element simulation was executed to obtain the K-value and evaluate the accuracy of bi-medium thermometer under various measurement environments. In addition, K-value estimation equation was developed by analyzing the influence of 5 measurement environmental factors (medium length, medium height, tissue depth, blood perfusion rate, and ambient temperature) on K-value. The results revealed that the estimation accuracy of bi-medium deep body thermometer based on computer simulation was very high (RMSE < $0.003^{\circ}C$) in various measurement environments. Also, bi-medium deep body thermometer based on K-value estimation equation showed relatively accurate results (RMSE < $0.3^{\circ}C$) except for one case. Although the K-value estimation technology should be improved for more accurate body temperature estimation, the results of finite element simulation showed that bi-medium deep body thermometer could accurately measure various tissue temperatures under diverse environments.

Visible Light Communication Based Wide Range Indoor Fine Particulate Matter Monitoring System (가시광통신 기반 광역 실내 초미세먼지 모니터링 시스템)

  • Shakil, Sejan Mohammad Abrar;An, Jinyoung;Han, Daehyun;Chung, Wan-Young
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.20 no.1
    • /
    • pp.16-23
    • /
    • 2019
  • Fine particulate matter known as PM 2.5 refers to the atmospheric particulate matter that has a diameter less than 2.5 micrometer identified as dangerous element for human health and its concentration can provide us a clear picture about air dust concentration. Humans stay indoor almost 90% of their life time and also there is no official indoor dust concentration data, so our study is focused on measuring the indoor air quality. Indoor dust data monitoring is very important in hospital environments beside that other places can also be considered for monitoring like classrooms, cements factories, computer server rooms, petrochemical storage etc. In this paper, visible light communication system is proposed by Manchester encoding technique for electromagnetic interference (EMI)-free indoor dust monitoring. Important indoor environment information like dust concentration is transferred by visible light channel in wide range. An average voltage-tracking technique is utilized for robust light detection to eliminate ambient light and low-frequency noise. The incoming light is recognized by a photo diode and are simultaneously processed by a receiver micro-controller. We can monitor indoor air quality in real-time and can take necessary action according to the result.

Comparisons of Collection 5 and 6 Aqua MODIS07_L2 air and Dew Temperature Products with Ground-Based Observation Dataset (Collection 5와 Collection 6 Aqua MODIS07_L2 기온과 이슬점온도 산출물간의 비교 및 지상 관측 자료와의 비교)

  • Jang, Keunchang;Kang, Sinkyu;Hong, Suk Young
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.5
    • /
    • pp.571-586
    • /
    • 2014
  • Moderate Resolution Imaging Spectroradiometer (MODIS) provides air temperature (Tair) and dew point temperature (Tdew) profiles at a spatial resolution of 5 km. New Collection 6 (C006) MODIS07_L2 atmospheric profile product has been produced since 2012. The Collection 6 algorithm has several modifications from the previous Collection 5 (C005) algorithm. This study evaluated reliabilities of two alternative datasets of surface-level Tair and Tdew derived from C005 and C006 Aqua MODIS07_L2 (MYD07_L2) products using ground measured temperatures from 77 National Weather Stations (NWS). Saturated and actual vapor pressures were calculated using MYD07_L2 Tair and Tdew. The C006 Tair showed lower mean error (ME, -0.76 K) and root mean square error (RMSE, 3.34 K) than the C005 Tair (ME = -1.89 K, RMSE = 4.06 K). In contrasts, ME and RMSE of C006 Tdew were higher than those (ME = -0.39 K, RMSE = 5.65 K) of C005 product. Application of ambient lapse rate for Tair showed appreciable improvements of estimation accuracy for both of C005 and C006, though this modification slightly increased errors in C006 Tdew. The C006 products provided better estimation of vapor pressure datasets than the C005-derived vapor pressure. Our results indicate that, except for Tdew, C006 MYD07_L2 product showed better reliability for the region of South Korea than the C005 products.