• 제목/요약/키워드: Ambient Control

검색결과 606건 처리시간 0.022초

실 구조물 진동제어를 위한 점탄성 댐퍼 설계 및 적용 실험 (Designs and Tests for the Vibration Control of Full-Scale Steel Frame Structure with Added Viscoelastic Dampers)

  • 정정교;김두훈;김영찬;박진일
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.687-692
    • /
    • 2002
  • In order to verify the effectiveness of adding visooelastic dampers to full-scale steel frame structure on the reduction of their seismic and wind response a experimental work was carried out. First, The test was conducted on the VE dampers subjected to sinusoidal excitations under a variety of ambient temperatures, frequency, and the damper strain. Results from these tests showed that the viscoelastic dampers have high energy dissipation capacity. Second, The vibration tests was conducted of the full-scale steel frame structure with md without added VE dampers at different temperatures. Viscoelastically damped full-scale structure test result on the effect of ambient temperature show that viscoelastic dampers are very effective in reducing excessive vibration of the structure due to sinusoidal excitation over a wide ringe of ambient temperature.

  • PDF

분사 조건이 다공형 GDI 인젝터의 분무 거동에 미치는 영향 (Effect of Injection Conditions on the Spray Behaviors of the Multi-hole GDI Injector)

  • 박정환;박수한;이창식;박성욱
    • 한국자동차공학회논문집
    • /
    • 제20권2호
    • /
    • pp.116-122
    • /
    • 2012
  • The purpose of this study is to investigate the overall spray behavior characteristics for various injection conditions in a gasoline direct injection(GDI) injector with multi-hole. The spray characteristics, such as the spray penetration, the spray angle, and the injection quantity, were studied through the change of the injection pressure, the ambient pressure, and the energizing duration in a high-pressure chamber with a constant volume. The n-heptane with 99.5% purity was used as the test fuel. In a constant volume chamber, the injected spray was visualized by the spray visualization system, which consisted of the high-speed camera, the metal-halide lamp, the injector control device, and the image analysis system with the image processing program. It was revealed that the injection quantity was mainly affected by the difference between the injection pressure and the ambient pressure. For low injection pressure conditions, the injection quantity was decreased by the increase of the ambient pressure, while it nearly maintained regardless of the ambient pressure at high injection pressure. According to the increase of the ambient pressure in the constant volume chamber, the spray development became slow, consequently, the spray tip penetration decreased, and the spray area increased. In additions, the circular cone area decreased, and the vortex area increased.

관측 환경에 따른 상시미동의 HVSR 결과 신뢰도 평가 (Reliability Assessment of Ambient Noise HVSR per Observation Condition)

  • 유병호;최우정;최인혁;곽동엽
    • 대한토목학회논문집
    • /
    • 제42권1호
    • /
    • pp.23-33
    • /
    • 2022
  • 상시미동의 수직성분에 대한 수평성분 스펙트럼비(HVSR)는 부지 공명주파수를 파악하는데 활발히 사용되고 있다. HVSR의 가장 큰 비율을 가지는 주파수는 부지 공명주파수와 일치한다. 상시미동은 부지 주변에 존재하는 미세진동을 의미하기 때문에 직접적인 진동원을 파악할 수 없으며, 또한 조절할 수 없다. 따라서 신뢰적인 상시미동 HVSR을 구하기 위해서는 상시미동 측정에 충분한 시간적 여유와 주변 환경의 파악 또한 필요하다. 본 연구에서는 신뢰적인 HVSR 분석에 필요한 상시미동 측정 최소시간과 지진계와 인위적인 진동 사이의 이격거리의 영향을 알아보았다. 토사 부지의 경우 센서 설치 후 5분 이내에 안정화가 되었으나, 암반 부지의 경우 안정화까지 1시간 이상이 소요되었다. 또한 상시미동 관측 시 발걸음 진동이 지진계 10 m 이내에 존재할 경우 HVSR결과에 큰 영향을 미치는 것을 확인하였다. 이러한 결과는 현장에서 상시미동의 HVSR측정에 필요한 가이드라인을 제공할 것으로 기대된다.

인테이크 도어 제어를 이용한 고성능 냉난방 시스템 (Air Intake Door Control for the High Air Conditioning Performance)

  • 박동규;김용철
    • 한국자동차공학회논문집
    • /
    • 제22권2호
    • /
    • pp.17-22
    • /
    • 2014
  • Recently, the quick heating performance is an important issue in the car because engine power becomes so high. So car makers have been adapted the additional heating devices as like PTC(Positive Temperature Coefficient) heater. And the quick cooling performance is also important issue because its result is used in the IQS(Initial Quality Study). In this paper, control of the HVAC(Heating, Ventilation and Air Conditioning) intake door has been studied for the quick heating and cooling performance. Heating performance is improved $4.0^{\circ}C$ at $-20^{\circ}C$ ambient temperature after 20 minutes. And cooling performance is improved $1.5^{\circ}C$ at $35^{\circ}C$ ambient temperature after 10 minutes. In addition, intake door control system brings on the cost reduction because the flab door can be eliminated. This intake door control system has been adapted to the new developing cars.

직분식 가솔린 인젝터의 분사 조건에 따른 분무 특성 분석 (An Investigation of the Spray Characteristics according to Injection Conditions for a Gasoline Direct Injector)

  • 이기형;이창식;이창희;류재덕;배재일
    • 한국자동차공학회논문집
    • /
    • 제9권5호
    • /
    • pp.89-95
    • /
    • 2001
  • Recently GDI(Gasoline Direct Injection) engine is spotlighted to achieve higher thermal efficiency under partial loads and better performance at full loads. To realize this system, it is essential to make both stratified combustion and homogeneous combustion. When compared to PFI(Port Fuel Injection) engine, GDI engine needs more complicated control and optimal design with injection system. In addition, spray pattern must be optimized according to injection timing because ambient pressure in combustion chamber is also varied. Thus spray structure should be analyzed in details to meet various conditions. In this experimental study, two types of visualization system were developed to simulate compression stroke and intake stroke, respectively. With an increase of the ambient pressure, the penetration length tends to decrease due to rising resistance caused by the drag force of the ambient air. Spray characteristics impinged on the piston has a significant effect on mixture stratification around the spark plug. These results provide the information on macroscopic spray structure and design factors far developing GDI injector.

  • PDF

세라믹 기판위에 코팅된 기능성 필름의 열처리 분위기에 따른 내오염 및 기계적 특성 (Effects of Annealing Ambient on the Anti-Pollution and Mechanical Properties of Functional Film Coated on the Ceramic Substrate)

  • 선박문;강현일;최원석;정연호
    • 한국전기전자재료학회논문지
    • /
    • 제29권4호
    • /
    • pp.215-217
    • /
    • 2016
  • For the improvement of the anti-pollution properties of porcelain electrical insulators, in this study, we have applied the functional film to the surface of insulator. The functional films were coated on the ceramic substrates which components were like the porcelain electrical insulator. The coating material was applied to ceramic substrate by spray coating method and then the film was cured at around $300^{\circ}C$ for 10 minutes with different gas ambient, such as $O_2$, $N_2$, and only vacuum. We have measured the contact angle of the coated surface, and obtained the lowest angle ($8.9^{\circ}$) and a strong hydrophilic property at vacuum condition. The anti-pollution properties were measured, revealing that as the contact angle decreased, the anti-pollution properties improved. The mechanical hardness and adhesion were both excellent regardless of the annealing ambient.

스파크점화직분식 CNG의 점화성 및 연소화염 특성에 대한 연구 (An Experimental Study on the Ignition Probability and Combustion Flame Characteristics of Spark-Ignited Direct-Injection CNG)

  • 황성일;정성식;염정국;전병열;이진현
    • 한국분무공학회지
    • /
    • 제21권1호
    • /
    • pp.37-46
    • /
    • 2016
  • For the SI engines, at only full load, the pumping loss has a negligible effect, while at part load conditions, the pumping loss increases. To avoid the pumping loss, the spark-ignited engines are designed to inject gasoline directly into the combustion chamber. In the spark-ignited direct-injection engines, ignition probability is important for successful combustion and the flame propagation characteristics are also different from that of pre-mixed combustion. In this paper, a visualization experiment system is designed to study the ignition probability and combustion flame characteristics of spark-ignited direct-injection CNG fuel. The visualization system is composed of a combustion chamber, fuel supply system, air supply system, electronic control system and data acquisition system. It is found that ambient pressure, ambient temperature and ambient air flow velocity are important parameters which affect the ignition probability of CNG-air mixture and flame propagation characteristics and the injected CNG fuel can be ignited directly by a spark-plug under proper ambient conditions. For all cases of successful ignition, the flame propagation images were digitally recorded with an intensified CCD camera and the flame propagation characteristics were analyzed.

초기 직경 변화가 Toluene 액적의 Soot 생성에 미치는 영향 (Effect of Initial Diameter on the Soot Generation of Toluene Fuel Droplet)

  • 임영찬;서현규
    • 한국분무공학회지
    • /
    • 제20권4호
    • /
    • pp.261-267
    • /
    • 2015
  • The main purpose of this study is to provide the information of soot generation of toluene fuel droplet. To achieve this, this paper provides the experimental results on the different initial diameter of toluene droplet combustion characteristics conducted under equivalent ambient pressure ($P_{amb}$) and oxygen concentration ($O_2$) conditions. Visualization of single fuel droplet was performed with high resolution CCD camera and visualization system. At the same time, ambient pressure ($P_{amb}$) and oxygen concentration ($O_2$) were maintained by ambient condition control system. Soot volume fraction ($f_v$) was analyzed and compared on the basis of intensity ratio ($I/I_0$) of background image. The result of soot generation was almost the same regardless of initial droplet diameter since thermophoretic flux is not much changed under the same ambient conditions. Soot standoff ratio (SSR) of 2 mm diameter showed unstable variation characteristics due to the short available measuring time.

FOG SYSTEM 을 이용한 여름철 온실냉방 (Greenhouse Cooling by Fog System)

  • 서원명
    • 한국농공학회지
    • /
    • 제41권1호
    • /
    • pp.60-71
    • /
    • 1999
  • This study was performed to improve underirable warm greenhouse environment by fog cooling system in summer season. The resultsof droplet size analysis and cooling effects for fog cooling system are summarized as follows ; 1. At the pump pressure of 70kgf/$\textrm{cm}^2$ , the mean (SMD) drop size was 22.6${\mu}{\textrm}{m}$ and the maximum and minimum drop size was 45.68${\mu}{\textrm}{m}$ and 1.73${\mu}{\textrm}{m}$ , respectively, and almost all of the drop size was less than 40${\mu}{\textrm}{m}$. 2. The temperature of fog cooling greenhouse with 60% shading was dropped more than 2$^{\circ}C$ below the ambient temperature , while the greenhouse temperature without shading was 1$^{\circ}C$ higher than the ambient temperature. 3. It was found that fog spraying intervals were significantly influential on cooling effect. 4. When the greenhouse was ventilated sufficiently by natural vent system, green house temperature could be maintained by 2.5$^{\circ}C$ lower than the ambient temperature, while it was difficult to drop the greenhouse temperature below ambient temeperature without sufficient ventilation. 5. It was found that the temperature of experimental greenhouse could be maintained 3$^{\circ}C$ to 14$^{\circ}C$ lower that of control greenhouse though there were variations depending on experimental and weather conditions.

  • PDF

알케인계 단일 연료 액적의 Soot 생성 특성에 관한 실험적 연구 (Experimental Study on the Soot Formation Characteristics of Alkane-based Single Fuel Droplet)

  • 임영찬;서현규
    • 한국분무공학회지
    • /
    • 제22권2호
    • /
    • pp.80-86
    • /
    • 2017
  • The soot formation characteristics of various alkane-based single fuel droplets were studied in this work. Also, This study was performed to provide the database of the soot behavior and formation of alkane-based single fuel droplet. The experimental conditions were set to 1.0 atm of ambient pressure ($P_{amb}$), 21% of oxygen concentration ($O_2$) and 79% of nitrogen concentration ($N_2$). Combustion and soot formation of single fuel droplet was visualized by visualization system with high speed camera. At the same time, ambient pressure, oxygen concentration and nitrogen concentration were maintained by ambient condition control system. Soot formation characteristics was analyzed and compared on the basis of intensity ratio ($I/I_0$) of background image. The results of toluene fuel droplet showed the largest soot generation. Soot volume fraction ($f_v$) was almost the same under the identical fuel types regardless of various initial droplet diameter ($d_0$) since thermophoretic flux was not much changed under the same ambient conditions.