• Title/Summary/Keyword: Ambient Air

Search Result 1,453, Processing Time 0.024 seconds

Performance Analysis of Hybrid Heat Pump System of the Air-to-Air/Air-to-Water with the Ambient Temperature (외기온 변화에 따른 공기-공기/공기-물 형태로 된 복합형 열펌프 시스템의 성능 특성 분석)

  • 송현갑
    • Journal of Biosystems Engineering
    • /
    • v.25 no.4
    • /
    • pp.273-278
    • /
    • 2000
  • The hybrid heat pump system of the air to air and / or air to water was composed and its COP was analyzed with the ambient temperature on the opened and closed loop system respectively. The results be indicated by the equation(7) that the COP(Coefficient of Performance) of air-source(air to air and / or air-water) heat pump is effected with the ambient air temperature and AVACTHE.(Automatic Variable Area Capillary Type Heat Exchanger) 2. The COP of air-to-water heat pump without AVACTHE decreased in accordance with the ambient temperature decrease, however in case of the heat pump with AVACTHE the COP was maintained at 2.8∼3.0 level when the ambient temperature decrease from -$5^{\circ}C$ to $-11^{\circ}C$. 3. The COP of the air-to-water heat pump operated on the open loop was higher 40∼58% than that of the heat pump operated on the close loop. 4. The lower ambient temperature air effect on the COP of the air-to-air heat pump operated on the semi closed loop could be controlled using the AVACTHE, and at the high ambient air temperature the COP increased using the Bypass circuit.

  • PDF

Effect of Ambient Air Temperature on the Pattern of Clothing Ventilation through Openings (환경 온도가 개구부를 통한 의복의 환기 양상에 미치는 영향)

  • 추미선
    • The Research Journal of the Costume Culture
    • /
    • v.10 no.6
    • /
    • pp.793-801
    • /
    • 2002
  • The effects of ambient air temperature on the clothing ventilation were investigated numerically by a finite difference method. Numerical analysis using a 2-dimensional model comprising the air space between the skin and the clothing was conducted under the assumption that the clothing ventilation occurred only through the openings not through the fabric. The larger the temperature difference between the skin and the surroundings, the more apparent the thermal boundary layer As the ambient air temperature decreased, the air flow and the rate of the return of oxygen concentration to the atmosphere level in the clothing increased. Convection was dominant under low ambient air temperature, whereas conduction was dominant under high ambient air temperature. The ventilation rate was faster in the clothing microenvironment of the body part than that of the arm part.

  • PDF

Pb, Cu, Zn Contaminants and Their Correlation of Soil, Leave and Bark of Ginkgo. B and Ambient Air Adjacent to a Heavy Traffic Road Side (교통량 과밀 도로주변의 토양과 가로수, 대기중 Pb, Cu, Zn 중금속 농도와 그 상관성에 관한 연구)

  • 박기학
    • Journal of Environmental Health Sciences
    • /
    • v.18 no.2
    • /
    • pp.19-25
    • /
    • 1992
  • The study was carried out to investigate the correlation between the heavy metals emitted by the motor vehicles with the heavy traffic road side environment (soil, leave, bark, ambient air). The Pb, Cu, Zn contents in road side soil sand leaves, barks from Ginkgo, biloba and ambient air adjacent to the heavy traffic road side from June to August, 1992 Suwon city were analyzed by Atomic absorption spectrometry and Inductively coupled plasma emission spectrophotometry. The results were as follows: 1) The high levels of heavy metals concentration were Pb, at city-terminal in soil (186 $\mu$g/g), Cu, at city-terminal in soil (221 $\mu$g/g), Zn, at city-terminal in ambient air (252 $\mu$g/m$^{3}$). 2) The low leves of heavy metals concentration were Pb, at North-gate in ambient air (1.65$\mu$g/m$^{3}$), Cu, at North-gate in ambient air (4 $\mu$g/m$^{3}$), Zn, at North-gate in ambient air (15.31$\mu$g/m$^{3}$). 3) The regional distribution of Pb, Cu, Zn in road side soils, leaves and barks from Ginkgo, biloba, ambient air show high levels in turn, city4erminal, Guan Sean Dong, South gate, North gate. 4) The concentration of heavy metals (Pb, Cu, Zn) in soils, leaves, barks, ambient air was highly correlated with the traffic volume of the sampling sites (r=0.64~0.96). To conclude that the high levels of Pb, Cu, Zn contaminations were positively related to motor vehicles-borne pollutants and road side soils, trees, ambient air adjacent to a high density building area with low road coverage and heavy traffic volume were reflected strongly by the hazardous pollutants emitted by motor vehicles.

  • PDF

Treatment of Nitrogen Oxides in Ambient Air using a Ion-Selective Electrode (대기중 질산화물의 이온 선택성 전극에 의한 처리)

  • 안형환;우인성;강안수;이영순;김윤선
    • Journal of the Korean Society of Safety
    • /
    • v.5 no.2
    • /
    • pp.40-49
    • /
    • 1990
  • For the determination of polluant NOx in ambient air, nitrate ion-selective electrode(ISE) was made. To comparison of NOx in each method, the nitrate-ISE, NEBA, Orion electrode were used to determinee NOx in ambient air. In this work, the concentration of NOx in ambient air was average 0.06ppm. The results were good agreement with those obtained by each method within a relative error of 3%, Absorbing efficiency of nitrogen oxides in ambient air was good for Alkali solution. The determination of nitrogen oxides in ambient air using the Aliquat 336N-PVC membrane electrode was one of the useful method. The best characteristics of the Aliquat 336N-PVC me,mbrane electrode were obtained with the ion-exchanger concentration level of 6.5-9.1 percent by weight. The optimal membrane composition, was 9.09wt.% of ion-exchanger, 30.95wt.% of PVC, 60.6wt.% of plasticizer (DBP), and 0.5mm of thickness. Under the above condition, the electrode approached the Nernstian slope most closely, and the linear response ranges produced the best results.

  • PDF

The Thermal Environmental Characteristics for Task-Ambient Air-Conditioning System in Heating Condition (Task-Ambient 공조시스템의 난방시 열환경 특성에 관한 실험적 연구)

  • 이정재;윤창오;정광섭;한화택;박영철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.2
    • /
    • pp.115-121
    • /
    • 2001
  • Recently, the requirement of healthier and more comfortable environment makes the zoning domain more details. However, it has limitation to satisfy the thermal comfort of an individual because of the effect of the heat generation from the OA machine and partitions in indoor room. In this paper, we certify the validity of task-ambient air-conditioning system that has been developed as a new concept of personal air-conditioning system, and specify design strategies for more efficient task-ambient air-conditioning system with a specification guided by indoor environmental characteristics analyzed through experiment data. In this experiment, we changed the temperature and the quantity of air-flow in task domain to understand characteristic behavior of the thermal environment and investigate the possibility of energy saving. The experiment result is that the environment of the task area depends on the condition of supply air, and though the airflow of the low temperature is supplied with the ambient area, the personal environment and the efficiency of energy saving are improved by controlling the temperature and the quantity of the air shot around the task domain.

  • PDF

Distribution Profile of Chiral Organochlorine Pesticides in Ambient Air (대기 환경 중 키랄 유기염소계 농약의 분포 특성)

  • Choi, Jong-Woo;Kim, Kum-Hee;Hwang, Seung-Ryul;Lee, Kyu-Seung
    • Korean Journal of Environmental Agriculture
    • /
    • v.31 no.3
    • /
    • pp.255-263
    • /
    • 2012
  • BACKGROUND: The analysis for the concentration and enantiomeric ratio of OCPs have been performed to confirm the distribution and to emonstrate the pollution characteristics of chiral OCPs in ambient air. METHODS AND RESULTS: In ambient air at coastal and inland sites, concentrations and enantiomer fractions (EFs) of heptachlor (HEPT), eptachlor epoxide (HEPX), trans-chlordane (TC), cis-chlordane (CC), xychlordane (OXY), 2,4'-DDT, 2,4'-DDD with HRGC/HRMS were investigated to understand source and distribution of chiral organochlorine pesticides (OCPs) in ambient air. The mean concentrations of OCPs in ambient air were at the range of 0.027(heptachlor)~1.279 (4,4'-DDT) pg/m3 and 0.0005 (heptachlor)~0.1043 ng/g d.w. (TC), respectively. The mean EFs of OCPs in ambient air were at the range of 0.73 (HEPX)~0.45 (CC). Both preferential depletions of (+) and (-) enantiomer were observed for CC, indicated by EFs either <0.5 or >0.5, while preferential depletions of (-) enantiomer which mean EFs <0.5 were observed for chiral OCPs except TC and MC-5. CONCLUSION: OCPs in ambient air have been distributed from soil, but some of them such as chlordane, DDT etc. might have been introduced by long-range atmospheric transport, considering EFs by chiral analysis and trajectory analysis.

Design and Performance Evaluation of the KIST Indoor Smog Chamber (실내 스모그 챔버의 설계 및 성능평가)

  • 배귀남;김민철;이승복;송기범;진현철;문길주
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.4
    • /
    • pp.437-449
    • /
    • 2003
  • A multi-functional indoor smog chamber was designed and evaluated to investigate photochemical or water vapor reaction mechanisms of air pollutants. Various smog chamber experiments could be conducted using ambient air or purified air in this smog chamber. The smog chamber consisted of a housing, a Teflon bag, blacklights, injection ports, sampling ports, and utility facilities. The characteristics of light source, the wall losses of air pollutants, and the quality of purified air were experimentally investigated. The maximum NO$_2$ photolysis rate was 1.10 min$^{-1}$ . In a 2.5-m$^3$ Teflon bag, the wall losses of ambient $O_3$, NO, and NO$_2$ were 1.2~2.4$\times$10$^{-3}$ min$^{-1}$ , 0.7~2.0$\times$10$^{-3}$ min$^{-1}$ , and 0.4~2.0$\times$10$^{-3}$ min$^{-1}$ , respectively. The wall loss of ambient particles ranging 0.05 to 0.2 ${\mu}{\textrm}{m}$ was 1.8~5.4$\times$10$^{-3}$ min$^{-1}$ , which was slightly higher than those of ambient gaseous species. The purified air supply system provided high quality of air with NO$_{x}$ < 1 ppb, and total hydrocarbons < 5 ppb.b.

Off-design Characteristics for Ambient Air Temperature and Turbine Load of Gas Turbine Pre-swirl System (가스터빈 프리스월 시스템의 외기 온도와 터빈 부하 조건에 따른 탈설계점 특성 분석)

  • Park, Hyunwoo;Lee, Jungsoo;Cho, Geonhwan;Cho, Jinsoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.12
    • /
    • pp.881-889
    • /
    • 2019
  • The pre-swirl system is the device that minimizes energy loss of turbine cooling airflow from the stationary parts into rotating parts. In this paper, an off-design analysis was conducted for the ambient air temperature and turbine load conditions. The discharge coefficient was constant for ambient air temperature and turbine load. However, adiabatic effectiveness was increased. This is due to the volume flow rate. The volume flow rate was increased at higher ambient temperature and higher turbine load. It means that the volume of cooling air was increased and the cooling performance of the air was improved. Consequently, adiabatic effectiveness increased by 30.46% at 100% turbine load compared to 20% turbine load. And increased by 18.42% at 55℃ ambient air temperature compared to -20℃ ambient air temperature.

Aerosol Wall Loss in Teflon Film Chambers Filled with Ambient Air

  • Lee Seung-Bok;Bae Gwi-Nam;Moon Kil-Choo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.E1
    • /
    • pp.35-41
    • /
    • 2004
  • Aerosol wall loss is an important factor affecting smog chamber experiments, especially with chambers made of Teflon film. In this work, the aerosol wall loss was investigated in 2.5 and $5.8-m^3$ cubic-shaped Teflon film chambers filled with ambient air. The natural change in the particle size distribution was measured using a scanning mobility particle sizer in a dark environment. The rate of aerosol wall loss was obtained from the deposition theory suggested by Crump and Seinfeld (1981). The measured rates of aero-sol wall loss were In a good agreement with the theoretical and experimental values given by McMurry and Rader (1985), implying that the electrostatic effect enhances particle deposition on the chamber wall. The significance of aerosol wall loss correction was demonstrated with the photochemical reaction experiments using the ambient air.

Calibration Methods for the Gas Chromatographic Analysis of ppt-level Hydrogen Sulfide (H2) in Air (환경 대기 중 ppt 수준의 황화수소 분석을 위한 GC 방식의 검량 기법에 대한 연구)

  • 김기현;오상인;최여진;최규훈;주도원
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.6
    • /
    • pp.679-687
    • /
    • 2003
  • In this study, we investigated the analytical techniques to quantify the ambient concentration of hydrogen sulfide (H$_2$S) in air at ppt concentration level. For this purpose, an on-line GC analytical system equipped with both pulsed-flame photometric detector (PFPD) and thermal desorption unit (TDU) was investigated by collecting ambient air samples. The results of our study generally indicated that calibration conditions of GC system is highly sensitive to affect the accuracy of the analytical technique. Most importantly. we found that the use of different matrices in the the preparation stage of working standards was sensitive to control the overall performance of this technique. The calibration of our analytical system was tested by the two types of working standard (prepared by mixing either with high purity $N_2$ or with the ambient air). According to this test, the latter represented more efficiently the detecting conditions of actual air samples. The peak occurrence patterns of both air samples and standards (prepared by mixing with ambient air) were altered in a similar manner as the function of the loaded volume; however, it was not the case for the $N_2$-mixed standards. Results of our study suggest that detection of H$_2$S is highly different from other sulfides and that its quantification requires minimiaing interfering effects of non -pure substance (like water vapor) and (either sorptive or destructive) loss effects.