• Title/Summary/Keyword: Alveolar ridge

Search Result 270, Processing Time 0.031 seconds

Absorbable Guided Bone Regeneration Membrane Fabricated from Dehydrothermal Treated Porcine Collagen (Dehydrothermal Treatment로 제작한 흡수성 콜라겐 골유도재생술 차단막)

  • Pang, Kang-Mi;Choung, Han-Wool;Kim, Sung-Po;Yang, Eun-Kyung;Kim, Ki-Ho;Kim, Soung-Min;Kim, Myung-Jin;Jahng, Jeong-Won;Lee, Jong-Ho
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.33 no.2
    • /
    • pp.112-119
    • /
    • 2011
  • Purpose: Collagen membranes are used extensively as bioabsorbable barriers in guided bone regeneration. However, collagen has different effects on tissue restoration depending on the type, structure, degree of cross-linking and chemical treatment. The purpose of this study was to evaluate the inflammatory reaction, bone formation, and degradation of dehydrothermal treated porcine type I atelocollagen (CollaGuide$^{(R)}$) compared to of the non-crosslinked porcine type I, III collagen (BioGide$^{(R)}$) and the glutaldehyde cross-linked bovine type I collagen (BioMend$^{(R)}$) in surgically created bone defects in rat mandible. Methods: Bone defect model was based upon 3 mm sized full-thickness transcortical bone defects in the mandibular ramus of Sprague-Dawley rats. The defects were covered bucolingually with CollaGuide$^{(R)}$, BioMend$^{(R)}$, or BioGide$^{(R)}$ (n=12). For control, the defects were not covered by any membrane. Lymphocyte, multinucleated giant cell infiltration, bone formation over the defect area and membrane absorption were evaluated at 4 weeks postimplantation. For comparison of the membrane effect over the bone augmentation, rats received a bone graft plus different covering of membrane. A $3{\times}4$ mm sized block graft was harvested from the mandibular angle and was laid and stabilized with a microscrew on the naturally existing curvature of mandibular inferior border. After 10 weeks postimplantation, same histologic analysis were done. Results: In the defect model at 4 weeks post-implantation, the amount of new bone formed in defects was similar for all types of membrane. Bio-Gide$^{(R)}$ membranes induced significantly greater inflammatory response and membrane resorption than other two membranes; characterized by lymphocytes and multinucleated giant cells. At 10 weeks postoperatively, all membranes were completely resorbed. Conclusion: Dehydrotheramal treated cross-linked collagen was safe and effective in guiding bone regeneration in alveolar ridge defects and bone augmentation in rats, similar to BioGide$^{(R)}$ and BioMend$^{(R)}$, thus, could be clinically useful.

Diagnostic Accuracy, Sensitivity, Specificity and Positive Predictive Value of Fine Needle Aspiration Cytology (FNAC) in Intra Oral Tumors

  • Gillani, Munazza;Akhtar, Farhan;Ali, Zafar;Naz, Irum;Atique, Muhammad;Khadim, Muhammad Tahir
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.8
    • /
    • pp.3611-3615
    • /
    • 2012
  • Objective: The objective of this study was to establish the diagnostic accuracy, specificity and sensitivity of fine needle aspiration cytology(FNAC) for intra-oral tumors, comparing with histopathology as the gold standard. Materials and methods: Forty cases of FNA cytology from intraoral tumors was performed in AFID along with the demographic data and clinical information and then diagnosed at AFIP, Rawalpindi. Then the cytology results obtained per FNAC were compared with the histopathological biopsy results of the same lesions. The following variables were recorded for each patient: Age, gender, site of biopsy, diagnosis. The data were entered and analyzed using Open-epi version 2.0. Diagnostic accuracy, sensitivity, specificity, positive predictive value and negative predictive value were calculated. Cohen Kappa was further applied to compare the agreement between the biopsy and FNAC diagnoses. A p-value of < 0.05 was considered as statistically significant. Results: Among the total patients included in the study there were 24 males and 16 females, with a ratio of 1.5:1. Age of the patients ranged from 24 to 80 years with a mean of 52 years. A total of six sites were aspirated from the oral cavity with maximum (11) aspirates taken from alveolar ridge. The results of FNAC revealed that there were 32 malignant and 8 benign aspirates. Confirmation through histopathological analysis came for 31/32 malignant cases while one was falsely given positive for malignancy on FNAC. Among a total of 40 cases, 31(77%) cases diagnosed were found to be malignant and remaining 9(23%) were benign. The FNAC results revealed 32 malignant and 8 benign lesions. Histopathology of the subsequent surgically excised specimen showed malignant lesions in 31(77%) and benign in 9(23%) patients. As a whole, it was found that the absolute sensitivity for introral FNAC was 100% and specificity 89% with positive predictive value of 97% and negative predictive value of 100%. Conclusion: Cytological diagnosis was almost corroborative with final histopathological diagnosis in all cases, with very few exceptions, exhibiting high diagnostic accuracy.

ACCURACY OF PREOPERATIVE ASSESSMENTS FOR CERVICAL LYMPH NODE METASTASIS IN ORAL CANCER (구강암 경부임파절 전이에 대한 술전 평가의 정확성)

  • Lee, Jae-Jun;Nam, Woong;Cha, In-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.32 no.2
    • /
    • pp.151-156
    • /
    • 2006
  • Purpose : The aim of this study was to determine the accuracy of clinical and radiologic assessments in detecting positive cervical lymph nodes in oral cancer. Materials and Methods : We had reviewed the preoperative clinical, radiologic and postoperative histopathologic reports of 46 patients who had been diagnosed as oral cancer and underwent surgical excision combined with neck dissection (52 sides of neck) in the Department of Oral and Maxillofacial Surgery, College of Dentistry, Yonsei University from the July 1, 1992 to the April 30, 1999. Results : The results were as follows 1. The male to female ratio was 4.38 : 1 and the mean age was 57. 2. Sensitivity values for the preoperative assessment of cervical lymph node metastasis in oral cancer were 62.5 % in clinical examination and 50.0 % in radiologic assessments. Specificity values were 77.8 % in clinical examination and 94.4 % in radiologic assessments. 3. False positive values were 44.4 % in clinical examination and 20.0 % in radiologic assessments. False negative values were 17.6 % in clinical and 19.0% in radiologic assessments. 4. Overall efficiency values were 73.1 % in clinical examination and 80.8 % in radiologic assessments. Summary : There were some limits on the accuracy of clinical and radiologic assessments in the preoperative detection of the cervical lymph nodes in oral cancer. To improve the accuracy, it is important to communicate between clinician and radiologist, and adjunctive diagnostic measures, ultrasound and fine needle aspiration cytology, were helpful increasing the overall efficiency. In the high risk sites (oral tongue and floor of the mouth) the false negative value is higher and the overall efficiency in radiologic evaluation is lower than those of the low risk sites (gingiva and alveolar ridge, retromolar trigone and buccal mucosa ). The elective neck dissection should be considered in the high risk sites.

Diode laser surgery in the treatment of oral proliferative verrucous leukoplakia associated with HPV-16 infection

  • Bombeccari, Gian Paolo;Garagiola, Umberto;Candotto, Valentina;Pallotti, Francesco;Carinci, Francesco;Gianni, Aldo Bruno;Spadari, Francesco
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.40
    • /
    • pp.16.1-16.5
    • /
    • 2018
  • Background: Proliferative verrucous leukoplakia (PVL) is an oral potentially malignant disorder, characterized by multifocal expression, progressive clinical evolution, and a high rate of malignant transformation. Evidence-based information regarding optimal PVL management is lacking, due to the paucity of data. The present report describes a case of PVL associated with HPV-16 infection and epithelial dysplasia treated by diode laser surgery, and the outcome of disease clinical remission over a 2-year follow-up period. Case report: A 61-year-old Caucasian male with oral verrucous hyperkeratosis presented for diagnosis. The lesions were localized on the maxillary gingiva and palatal alveolar ridge. Multiple biopsy specimens have been taken by mapping the keratotic lesion area. Microscopic examination was compatible with a diagnosis of PVL with focal mild dysplasia, localized in the right maxillary gingiva. Polymerase chain reaction (PCR) was done for human papillomavirus (HPV) detection which revealed presence of HPV DNA, and the genotype revealed HPV 16 in the sample. The PVL in the right gingival area was treated on an outpatient basis by excision with a diode laser. This approach resulted in good clinical response and decreased morbidity over a 2-year follow-up period. Conclusions: This case illustrates the benefit of a conservative approach by diode laser treatment than wide surgical excision for management of the PVL lesions associated with mild dysplasia and HPV-16 infection.

A 3 year prospective study of survival rate of narrow diameter implants (좁은 직경 임플란트 3년간의 생존율에 관한 후향적 연구)

  • Lee, Sung-Jo;Jung, Sae-Young;Shin, Hyun-Seung;Park, Jung-Chul;Song, Young-Gyun;Cho, In-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.1
    • /
    • pp.32-38
    • /
    • 2018
  • Purpose: The purpose of present study was to retrospectively analyze the survival rate of narrow diameter implant less than 3.6 mm by initial stability and radiographic measurements. Materials and Methods: In total, 24 patients who received 38 narrow diameter implants (${\leq}3.6mm$ in diameter, ${\geq}7mm$ in length) were enrolled in this retrospective study. The cumulative survival rate was calculated and various factors were investigated according to the implant platform diameter, body diameter, length, position, concomitant use of guided bone regeneration in implant placement and final prosthesis type. Initial stability was investigated with implant stability quotient (ISQ) value. The mesial and distal marginal bone level (MBL) change was calculated with radiography. Results: The overall survival rate was 92.11%. Mean ISQ value and MBL change of survival implants was 66.26 and $0.14{\pm}0.31mm$, respectively. None of the implants with platform diameters larger than the body diameter failed. Conclusion: In conclusion, the findings of present study suggest that narrow diameter implant could be predictable treatment in narrow alveolar ridge.

Influence of wound closure on volume stability with the application of different GBR materials: an in vitro cone-beam computed tomographic study

  • Naenni, Nadja;Berner, Tanja;Waller, Tobias;Huesler, Juerg;Hammerle, Christoph Hans Franz;Thoma, Daniel Stefan
    • Journal of Periodontal and Implant Science
    • /
    • v.49 no.1
    • /
    • pp.14-24
    • /
    • 2019
  • Purpose: To assess the influence of using different combinations of guided bone regeneration (GBR) materials on volume changes after wound closure at peri-implant dehiscence defects. Methods: In 5 pig mandibles, standardized bone defects were created and implants were centrally placed. The defects were augmented using different combinations of GBR materials: xenogeneic granulate and collagen membrane (group 1, n=10), xenogeneic granulate and alloplastic membrane (group 2, n=10), alloplastic granulates and alloplastic membrane (group 3, n=10). The horizontal thickness was assessed using cone-beam computed tomography before and after suturing. Measurements were performed at the implant shoulder (HT0) and at 1 mm (HT1) and 2mm (HT2) below. The data were statistically analysed using the Wilcoxon signed-rank test to evaluate within-group differences. Bonferroni correction was applied when calculating statistical significance between the groups. Results: The mean horizontal thickness before suturing was $2.55{\pm}0.53mm$ (group 1), $1.94{\pm}0.56mm$ (group 2), and $2.49{\pm}0.73mm$ (group 3). Post-suturing, the values were $1.47{\pm}0.31mm$ (group 1), $1.77{\pm}0.27mm$ (group 2), and $2.00{\pm}0.48mm$ (group 3). All groups demonstrated a loss of horizontal dimension. Intragroup changes exhibited significant differences in group 1 (P<0.001) and group 3 (P<0.01). Intergroup comparisons revealed statistically significant differences of the relative changes between groups 1 and 2 (P=0.033) and groups 1 and 3 (P=0.015). Conclusions: Volume change after wound closure was minimized by using an alloplastic membrane. The stability of the augmented horizontal thickness was most ensured by using this type of membrane irrespective of the bone substitute material used for membrane support.

Implant-assisted overdenture using milled bar and ADD-TOC in edentulous maxilla: A case report (상악 무치악 환자에서 Milled Bar와 ADD-TOC을 이용한 임플란트 피개의치 수복 증례)

  • Jo, Yong-Bum;Jeong, Chang-Mo;Huh, Jung-Bo;Yun, Mi-Jung;Lee, So-Hyoun;Kim, Min-Jung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.160-167
    • /
    • 2022
  • One of the treatment options for edentulous state patients with residual ridge resorption is implant overdenture using milled bar and attachment. It not only provides improved retention and stability but can also reduce the coverage of palatal surface. In addition, when a small number of implants are used, milled bar has the effect of being splinted between implant fixtures, which makes it mechanically advantageous under functions such as mastication. The patient in this case was a maxillary edentulous state patient with a considerable amount of residual alveolar bone resorption after removing the existing failed implants. Three implants were planted on both sides and an implant overdenture was fabricated using milled bar and ADD-TOC attachment.

Fabrication of surveyed crown and repairing the artificial teeth for existing removable partial denture using digital technology: a case report (디지털 방식을 이용한 기존 국소의치 맞춤 보철 제작과 심미적인 인공치 수리 증례)

  • Ina Kim;Eunji Oh;Sang-Won Park;Hyun-Pil Lim;Kwi-dug Yun;Chan Park
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.2
    • /
    • pp.82-90
    • /
    • 2024
  • It often happens that a removable partial denture needs to be repaired due to tissue changes in the remaining alveolar ridge, fracture of the denture, or fracture of the abutment tooth. There are several advantages to retrofitting a customized surveyed crown under the existing RPD. Retrofitting a crown to the RPD decreases the economic burden to the patient and avoids the need for several appointments to fabricate a new RPD. It is difficult for artificial teeth used to repair dentures due to fractured natural teeth to have a shape similar to that of natural teeth, and to repair aesthetic artificial teeth, it is necessary to manufacture customized artificial teeth similar to the shape of each patient's teeth. Recently, CAD/CAM technology has been used to fabricate customized prosthetics on existing RPD to achieve high retention and fitness accuracy, and by manufacturing customized artificial teeth, more aesthetic and harmonious artificial tooth repair is possible. This is a case in which a denture was repaired using a digital method to fabricate a customized prosthesis on an existing partial denture and customized artificial teeth that mirrored the adjacent dentition, saving time and cost, simplifying the process, and achieving aesthetically and functionally satisfactory results.

Implant assisted removable partial denture using bilateral single implant-supported surveyed crown: a case report (양측성 단일 임플란트 지지 서베이드 크라운을 이용한 하악 임플 란트 보조 국소의치 수복 증례)

  • Seojune Choi;Hong Seok Moon;Jaeyoung Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.146-156
    • /
    • 2024
  • Implant assisted removable partial denture (IARPD) has been practiced in various forms for a long time, and among them, implant surveyed crown RPD is gaining predictability as well as being considered as a treatment option for patients with anatomical and financial disadvantages. The position of implant could be divided as posterior placement or anterior placement according to the purpose of the treatment and should be planned in consider to the alveolar ridge of patient, anticipated prognosis of remaining teeth, and opposing dentition. This case report describes a treatment for mandibular Kennedy class I partial edentulous patient with two implant-supported surveyed crown and implant assisted removable partial denture. Given the difficulty of posterior placement in this patient and the prognosis of the residual teeth, the plan was to place two implants in close proximity to the residual teeth, which were placed in the planned position, angle, and depth using guided surgery. The process of fabricating the fixed prosthesis was carried out in parallel with the maxillary edentulous tooth arrangement process to increase predictability, and when fabricating the localized tooth, the implant was designed in a form that allows the patient to perform functional movements by preventing excessive loading as the last supporting tooth, and was fabricated through a secondary impression process. Each treatment procedure was proceeded as planned, with aesthetically and functionally satisfactory results for both patient and operator.

Removable implant-supported partial denture using milled bar with Locator® attachments in a cleft lip & palate patient: A clinical report (구순구개열 환자에서 Locator® 유지장치가 장착된 milled titanium bar를 이용한 가철성 임플란트 피개 국소의치의 보철수복증례)

  • Yang, Sang-Hyun;Kim, Kyoung-A;Kim, Ja-Yeong;Seo, Jae-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.3
    • /
    • pp.207-214
    • /
    • 2015
  • Due to the limitations of conventional removable partial denture prostheses to treat a cleft lip & palate patient who shows scar tissue on upper lip, excessive absorption of the maxillary residual alveolar ridge, and class III malocclusion with narrow palate and undergrowth of the maxilla, 4 implants were placed on the maxillary edentulous region and a maxillary removable implant-supported partial denture was planned using a CAD/CAM milled titanium bar. Unlike metal or gold casting technique which has shrinkage after the molding, CAD/CAM milled titanium bar is highly-precise, economical and lightweight. In practice, however, it is very hard to obtain accurate friction-fit from the milled bar and reduction in retention can occur due to repetitive insertion and removal of the denture. Various auxiliary retention systems (e.g. $ERA^{(R)}$, $CEKA^{(R)}$, magnetics, $Locator^{(R)}$ attachment), in order to deal with these problems, can be used to obtain additional retention, cost-effectiveness and ease of replacement. Out of diverse auxiliary attachments, $Locator^{(R)}$ has characteristics that are dual retentive, minimal in vertical height and convenient of attachment replacement. Drill and tapping method is simple and the replacement of the metal female part of $Locator^{(R)}$ attachment is convenient. In this case, the $Locator^{(R)}$ attachment is connected to the milled titanium bar fabricated by CAD/CAM, using the drill and tapping technique. Afterward, screw holes were formed and 3 $Locator^{(R)}$ attachments were secured with 20 Ncm holding force for additional retention. Following this procedure, satisfactory results were obtained in terms of aesthetic facial form, masticatory function and denture retention, and I hereby report this case.