• Title/Summary/Keyword: Alternative flow system

Search Result 316, Processing Time 0.03 seconds

Investigation on the Selection of Capillary Tube for the Alternative Refrigerant R-407C

  • Kim, Chang-Nyeun;Park, Young-Moo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.8 no.1
    • /
    • pp.40-49
    • /
    • 2000
  • The capillary tube performance for R-407C is experimentally investigated. The experimental setup is a real vapor-compression refrigerating system. Mass flow rate is measured for various diameter and length while inlet pressure and degree of subcooling are changed. These data are compared with the results of a numerical model. The mass flow rate of the numerical model is about 14% less than the measured mass flow rate. It is found that mass flow rate and length for R-407C are less than those for R-22 under the same condition. Based on this experimental study and the numerical model, a set of design charts for capillary tube of R-407C is proposed.

  • PDF

Utilization of the Outflowing Groundwater Resources in an Underpass Structure

  • Jin, Kyu-Nam;Park, Jae-Hyeon;Lee, Jung-Min;Lee, Sang-Ho
    • Environmental Engineering Research
    • /
    • v.18 no.3
    • /
    • pp.117-121
    • /
    • 2013
  • For underpasses in Yeongjong Sky City business district, the guided drainage system, as a buoyancy prevention system has been designed, and is under construction. This paper investigates the safety of the guided drainage system for underpass structures being constructed in Yeongjong Sky City business district. This paper also calculates the amount of outflowing groundwater generated by the guided drainage system, and proposes alternative usages of the water. In order to investigate safety and field applicability of the guided drainage system for underpasses, characteristics of the surface flow for the area of interest have been analyzed, and the flow change of groundwater following the underpass structure construction has been evaluated using the 3-dimensional groundwater program MODFLOW. The influence of ground water on safety of the underpass structures has been calculated by FLAC2D analysis. For alternative usages for the outflowing groundwater generated by the guided drainage system, utilization methods of the outflowing groundwater in national and international resources have been researched. The amount of an outflowing groundwater to be generated in the area of interest has been analyzed, and efficient potential usages of this groundwater have been researched. When guided drainage technique is applied, the change in flow of groundwater must be evaluated and considered as safety factor relating to the buoyancy of the structure. As a result, safety factor demonstrated more than 1.2, meaning that the underpass structure is safe. The amount of subsoil drain generated by the guided drainage system was also analyzed. The quality and amount of water satisfied the standards and volume requirements, so as to make it applicable for a number of uses, such as X, Y, and Z, and should prove to be a valuable resource as the circumstances of the neighboring area change over time. These resources can be used as basic data for future urban water circulation studies, as well as generating research of alternative water usages.

Transient Stability Analysis of Vessel Power System Using Alternative Marine Power (육상전원공급장치(AMP) 이용한 선내 전원 공급 시 계통 안정도 분석)

  • Seung-pyo Kang;Jang-mok Kim;Hyun-jun Cho
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.2
    • /
    • pp.215-222
    • /
    • 2023
  • Alternative marine power (AMP) is continuously used in ports and on docks because of regulations on global ship emission reduction. In Korea, the use of AMP is also mandatory under the Special Act on Port Air Quality Improvement, and efforts are under way in connection with various eco-friendly ships, such as electric-propulsion ships. In this study, AC load flow analysis was performed by modeling the situation in which onboard power is supplied through AMP. This analysis made it possible to study the electrical parameters and losses when power was supplied to the ship. In addition, through a transient stability analysis, the high-speed generation transfer limit value for uninterruptible conversion through onboard generators in the event of a system accident was derived. The results obtained when it was applied are presented

Improvement of Memory Efficiency for Alternative Sequence in Process Control System Described by SFC (SFC로 설계된 공정제어에서 선택시퀀스의 메모리효율향상)

  • You, Jeong-Bong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.5
    • /
    • pp.55-61
    • /
    • 2010
  • When we design the control system used Programmable Logic Controller(PLC) by Sequential Function Chart(SFC), if we use a SFC, it is easy to know the sequential flow of control, to maintenance the controller and to describe a program. We program a SFC by a unique sequence, an alternative sequence and a parallel sequence. If we program a SFC by a alternative sequence, the memory size of a alternative sequence must be larger than the memory size of a unique sequence. Therefore this thesis show an efficient method to reduce a memory size and we confirmed its feasibility through actual example.

A study on Material Flow Improvement of Multiproduct Flow Line Production System (다품종흐름생산 시스템의 물류개선에 관한 연구)

  • Lee, Hwa-Ki;Seong, Youn-Ho
    • IE interfaces
    • /
    • v.6 no.1
    • /
    • pp.99-112
    • /
    • 1993
  • This study deals with analysis of material from in Tube manufacturing line. This line is a multi product flow ship type production line, which consists of 5 steps of work station. Some work stations involve in unnecessary moving activities of workers and much work in-process storage due to the non-systematic material flow with respect to the different lot size production of multi-items. To improve productivity for this line, one alternative is considered such as grouping two work stations by using GT and JIT concepts. Also, feasibility analysis for this alternative is performed using and simulation model built by SIMAN IV simulation language.

  • PDF

A Study on Securing Instream Flow for Restoring Ecosystems and Riverine Aesthetics of a Degraded Urban Stream - Applied to the Mugeo Stream in the Ulsan Metropolitan Area - (하천생태계와 경관복원을 위한 도시소하천의 유지유량확보에 관한 연구 - 울산 무거천을 중심으로 -)

  • Lee, Soo-Sik
    • Journal of Environmental Science International
    • /
    • v.16 no.5
    • /
    • pp.649-655
    • /
    • 2007
  • This study was focused on estimating instream flow, and its optimal alternative for securing the required total amount of instream flow was also researched in order to restore ecosystems and riverine aesthetics of the Mugeo Stream. the first tributary of the Taewha River flowing through the center of Ulsan. In this study the hydraulic and hydrologic conditions and water quality were investigated at specific channel reaches and representative stations of the Mugeo Stream to determine a proper estimate of instream flow. And riverine functions, such as the minimum flow, water duality conservation, fish habitat, and recreation, were considered to restore the environmental functions of the stream, As a result, the total amount of $11,500m^3/day$ was set as the target instream flow for the Mugeo Stream. It was chosen as the optimal alternative for securing the total external supply of $10,000m^3/day$ which have to be transfered from the riverbed flow diverted through the Taewha Main river at upstream of Samho bridge. The water duality throughout the Mugeo Stream channels will be improved considerably to 3-4 mg/l of BOD standard if the target instream flow is supplied and sewage is intercepted by the sanitary sewage system.

Flow Line에서의 소팅 및 버퍼링 시스템 적용 연구

  • 박정현;최병규
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.859-863
    • /
    • 1995
  • Presented in the paper are a review of sorting and buffering system(SBS), the design procedure of a SBS and an analytical model for the initial alternative generation. SBS is an automated material handling system in which incoming items of different part types are automatically sorted and buffered so that the processing machines can process the part in lots. SBSs play a key role in modern manufacturing systems ans are widely found in mass fabrication lines, packaging and palletizing, and disribution centers.

  • PDF

Three-phase Load Flow using DistFlow Method (DistFlow Method를 이용한 삼상조류해석 알고리즘에 관한 연구)

  • Kwak, Do-Il;Kim, Tae-Eung;Kim, Jae-Eon
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.43-45
    • /
    • 2000
  • Traditionally, load flows have been calculated using the Gauss-Seidel and Newton-Raphson Method. DistFlow Method which is proposed by Wu and Baran is superior to the other two methods because it does not require the admittance matrix calculation to optimize the distribution system. This paper introduces a new alternative algorithm to the DistFlow Method which is slow and complex to find solutions as the number of lateral and sublateral increases. The proposed load flow method can construct System Jacobian easily. We can minimize the off-diagonal elements of the branch Jacobian and submatrices in the System Jacobian. Simulation results show that progressive performances of the proposed algorithm.

  • PDF

Experimental Study on Heat and Mass transfer Coefficient Comparison Between Counterflow Types and Parallel in Packed Tower of Dehumidification System

  • Sukmaji, I.C.;Choi, K.H.;Yohana, Eflita;Hengki R, R.;Kim, J.R.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.162-169
    • /
    • 2009
  • In summer electrical energy is consumed in very high rate. It is used to operate conventional air conditioning system. Hot and humid air can germinate mould spores, encourage ill health, and create physiological stress (discomfort). Dehumidifier solar cooling effect is the one alternative solution saving electrical energy. We use surplus heat energy in the summer, to get cooling effect and then to get human reach to comfort condition. These devices have two system, dehumidifier and regeneration system. This paper will be focus in dehumidifier system. Dehumidifier system use for absorbing moisture in the air and decreasing air temperature. When the liquid desiccant as strong solution contact with the vapor air in the packed tower, it works. The heat and mass transfer performances of flow pattern in the packed tower of dehumidifier are analyzed and compared in detail. In this experiment was introduced, the flow patterns are parallel flow and counter flow. The performance of these flow patterns will calculate from air side. Which is the best flow pattern that gave huge mass transfer rate? The proposed dehumidifier flow pattern will be helpful in the design and optimization of the dehumidifier solar cooling system.

  • PDF

Performance Analysis of Two-stage Compression Refrigeration System with Internal Heat Exchanger Applied Various Refrigerants (다양한 냉매를 적용한 내부열교환기 부착 2단 압축 냉동시스템의 성능 분석)

  • Yoon, Jung-In;Heo, Seong-Kwan;Je, Jae-Myun;Jeon, Min-Ju;Son, Chang-Hyo;Moon, Jung-Hyun
    • Journal of Power System Engineering
    • /
    • v.19 no.6
    • /
    • pp.82-88
    • /
    • 2015
  • In this paper, cycle performance analysis of two-stage compression and one-stage expansion refrigeration system applied various refrigerants is presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include degree of superheating and subcooling, compressor efficiency, evaporation temperature, condensing temperature, mass flow rate ration into inter-cooler, effectiveness of internal heat exchanger. The main results were summarized as follows : The COP of two-stage compression and 1-stage expansion refrigeration system increases with the increasing subcooling, mass flow rate ration of inter-cooler, evaporation temperature, but decreases with the increasing condensing temperature and superheating degree. Therefore, subcooling degree, mass flow rate ratio of inter-cooler of two-stage compression and 1-stage expansion using substitute refrigerant have an effect on COP of this system. The COP of alternative refrigerants was higher than the COP of R22 in this study, although the COP of some mixed refrigerants were lower than COP of R22.