• Title/Summary/Keyword: Alternative Coagulant

Search Result 17, Processing Time 0.029 seconds

Production of Alternative Coagulant Using Waste Activated Alumina and Evaluation of Coagulation Activity (폐촉매 부산물로부터 대체 응집제 제조 및 응집성능 평가)

  • Lee, Sangwon;Moon, Taesup;Kim, Hyosoo;Choi, Myungwon;Lee, Deasun;Park, Sangtae;Kim, Changwon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.7
    • /
    • pp.514-520
    • /
    • 2014
  • In this study, the production potential of alternative coagulant ($Al_2(SO_4)_3$ solution) having the identical coagulation activity with respect to the commercial coagulant was investigated. The raw material of alternative coagulant was a spent catalyst including aluminium (waste activated alumina) generated in the manufacturing process of the polymer. The alternative coagulant was produced through a series of processes: 1) intense heat and grinding, 2) chemical polymerization and substitution with $H_2SO_4$ solution, 3) dissolution and dilution and 4) settling and separation. To determine the optimal operating conditions in the lab-scale autoclave and dissolver, the content of $Al_2O_3$ in alternative coagulant was analyzed according to changes of the purity of sulfuric acid, reaction temperature, injection ratio of sulfuric acid and water in the dissolver. The results showed that the alternative coagulant having the $Al_2O_3$ content of 7~8% was produced under the optimal conditions such as $H_2SO_4$ purity of 50%, reaction temperature of $120^{\circ}C$, injection ratio of $H_2SO_4$ of 5 times and injection ratio of water of 2.3 times in dissolver. In order to evaluate the coagulation activity of the alternative coagulant, the Jar-test was conducted to the effluent in aerobic reactor. As a result, in both cases of Al/P mole of 1.5 and 2.0, the coagulation activity of the alternative coagulant was higher than that of the existing commercial coagulant. When the production costs were compared between the alternative and commercial coagulant through economic analysis, the production cost reduction of about 50% was available in the case of the alternative coagulant. In addition, it was identified that the alternative coagulant could be applied at field wastewater treatment plant without environmental problem through ecological toxicity testing.

Determination of the Coagulant Injection Methods for Efficient Treatment of Industrial Wastewater (산업폐수의 효율적 처리를 위한 응집제의 주입방법 결정)

  • Park, Se-Jin;Jung, Byung-Gil
    • Journal of the Korean Society for Environmental Technology
    • /
    • v.19 no.6
    • /
    • pp.570-575
    • /
    • 2018
  • The various of raw wastewater inflows to the industrial wastewater treatment plants everyday. This makes it difficult to operate the coagulation and flocculation efficiently as a pretreatment process for the industrial wastewater treatment. Additionally, it causes loads on evaporation and membrane facilities which are the posttreatment and alternative processes. For this reason, this study sampled raw wastewater before and after the NaOH injection. An experiment was conducted to compare the coagulation characteristics according to the methods of coagulant injection (single injection, simultaneous injection, consecutive injection, and inverse injection) aiming at efficient treatment of industrial wastewater. The coagulation experiment was conducted using a jar tester. The TDS removal efficiency by the coagulant injection methods increased in the order of consecutive injection (2.8 %) < single injection (3.9 %) < simultaneous injection(8.1 %) < inverse injection(9.6 %); the TOC removal efficiency grew in the order of single injection (84.3 %) < inverse injection (86.2 %) < consecutive injection (88.6 %) < simultaneous injection (89.1 %); the turbidity removal efficiency grew from single injection (99.7 %) < consecutive injection (99.8 %) ${\fallingdotseq}$ inverse injection (99.8 %) < simultaneous injection (99.9 %). These results show that the simultaneous inorganic coagulant-polymer coagulant injection method was more efficient than the consecutive injection method (inorganic coagulant ${\rightarrow}$ polymer coagulant).

ε-polylysine biopolymer for coagulation of clay suspensions

  • Kwon, Yeong-Man;Im, Jooyoung;Chang, Ilhan;Cho, Gye-Chun
    • Geomechanics and Engineering
    • /
    • v.12 no.5
    • /
    • pp.753-770
    • /
    • 2017
  • The coagulation or flocculation of cohesive clay suspensions is one of the most widely used treatment technologies for contaminated water. Flocculated clay can transport pollutants and nutrients in ground water. Coagulants are used to accelerate these mechanisms. However, existing coagulants (e.g., polyacrylamide, polyaluminum chloride) are known to have harmful effects in the environment and on human health. As an alternative, eco-friendly coagulant, this study suggests ${\varepsilon}-polylysine$, a cationic biopolymer fermented by Streptomyces. A series of sedimentation experiments for various ${\varepsilon}-polylysine$ concentrations were performed, and the efficiency of sedimentation with ${\varepsilon}-polylysine$ was estimated by microscopic observation and light absorbance measurements. Two types of sedimentation were observed in the experiments: accumulation sedimentation (at 0.15%, 0.20%, 0.25% ${\varepsilon}-polylysine$) and flocculation sedimentation (at 0%, 0.1%, 0.5%, 1.0%, 2.0% ${\varepsilon}-polylysine$). These sedimentation types occur as a result of the concentration of counter ions. Additionally, the performance of ${\varepsilon}-polylysine$ was compared with that of a previously used environmentally friendly coagulant, chitosan. The obtained results indicate that flocculation sedimentation is appropriate for contamination removal and that ${\varepsilon}-polylysine$ functions more efficiently for clay removal than chitosan. From the experiments and analysis, this paper finds that polylysine is an alternative eco-friendly coagulant for removing chemical contaminants in groundwater.

Evaluation on the Locations of Powdered Activated Carbon Addition for Improvement of Taste and Odor Removal in Drinking Water Supplies (상수원수 내 이취미 제거효율 향상을 위한 분말활성탄 투입지점의 평가)

  • Kim, Young-Il;Lee, Sang-Jin;Bae, Byung-Uk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.3
    • /
    • pp.341-348
    • /
    • 2007
  • The efficiency of powdered activated carbon (PAC) for removing taste and odor (T&O) in drinking water supplies is dependent on the contact time, quality of mixing, and the presence of competing compounds. All of these are strongly influenced by the stage in the treatment process at which the PAC is added. In conventional water treatment plants (WTPs), PAC is commonly added into the rapid mixing basin where chemicals such as coagulants, alkaline chemicals, and chlorine, are simultaneously applied. In order to prevent interference between PAC and other water treatment chemicals, alternative locations for addition of PAC, such as at transmission pipe in the water intake tower or into a separated PAC contactor, were investigated. Whatever the location, addition of PAC apart from other water treatment chemicals was more effective for geosmin removal than simultaneous addition. Among several combinations, the sequence 'chlorine-PAC-coagulant' produced the best result with respect to geosmin removal efficiency. Consequently, when PAC has to be applied to cope with T&O problems in conventional WTPs, it is very important to prevent interference with other water treatment chemicals, such as chlorine and coagulant. Adequate contact time should also be given for adsorption of the T&O compounds onto the PAC. To satisfy these conditions, installation of a separated PAC contactor would be the superior alternative if there is space available in the WTP. If necessary, PAC could be added at transmission pipe in the water intake tower and still provide some benefit for T&O treatment.

The Application of Aluminum Coagulant for the Improvement of Water Quality in Three Recreational Ponds (알루미늄 응집제를 사용한 호수수질 개선 사례 연구)

  • Kang, Phil-Goo;Kim, Bom-Chul
    • Korean Journal of Ecology and Environment
    • /
    • v.36 no.4 s.105
    • /
    • pp.447-454
    • /
    • 2003
  • Aluminum coagulant was applied to two eutrophic lakes (Lake Sukchon, in Seoul, and a pond on the campus of Kangwon National University), to precipitate suspended particles and phosphate from the water column. Aluminum sulfate (alum) was used for seven treatments and polyaluminum chloride (PAC) was used for one treatment. The effect of treatment varied depending on the dose of alumium coagulant. Particles and phosphate were completely precipitated from the water column with a dose of 10.0 mgAl/l. Partial removal was observed at doses of 3.3 and 1.8 mgAl/l, but not at 0.45 mgAl/l. Therefore, coagulant should be applied at a dose over the threshold in order to remove particles effectively, which seems to be between 1.8 and 10.0 mgAl/l. The length of treatment effect was determined by new inputs of nutrients and particles from external sources. Renewal of pond water by stream water caused recovery of algal growth in Lake Sukchon, and rainfall runoff and ground water pumping caused a return of turbid water in the campus pond. During treatment there was no sign of decreasing pH, or harmful effects on fish or mussels. Aluminum coagulant may be an economically feasible alternative for water quality improvement when the external control of pollutant sources is difficult. However, repeated application is required when there is a renewal of lake water or new input of nutrients.

A Feasibility Study on Optimization System of Coagulant Dosing for Total Phosphorous Treatment (총인 처리를 위한 응집제 주입량 최적제어 시스템의 적용성 연구)

  • Seo, Jeong-Mi;Cho, Young-Beom;Choi, Ye-Mook;Park, Chul-Hwi
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.7
    • /
    • pp.483-491
    • /
    • 2014
  • In this study, we developed an M-COS (molit coagulant-dosing optimization system), which enables to apply the optimum coagulant dose determined in real time, in order to satisfy the total phosphorus (TP) regulation (0.5 mg/L), and then tested its field applicability. Field tests were conducted at three different periods in 2014 in a pilot plant where the M-COS was installed. Coagulant reduction rate by the M-COS was 10.4%, 15.3%, and 9.0% for each period (average 11.6%), when comparing with a control where coagulants were applied at a constant rate. Total cost for the M-COS or control was estimated by summing up the coagulant cost and sludge treatment cost, and then the resulting cost increase was predicted. Cost reduction rate by the M-COS was 13.8%, 20.0%, and 11.4% for each period (average 15.0%). This study indicates that the M-COS can be an alternative to a conventional system for TP treatment, with a better cost efficiency.

Substitutability of coagulation process by pre-treatment of coagulation·flotation using natural algae coagulant (천연조류제거제를 활용한 응집·부상 전처리공정의 기존 응집공정 대체 가능성)

  • Jang, Yeo-Ju;Jung, Jin-Hong;Lim, Hyun-Man;Chang, Hyang-Youn;Kim, Weon-Jae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.1
    • /
    • pp.39-50
    • /
    • 2017
  • In the coagulation/sedimentation (C/S) process of the water treatment process, the inflow of massive algal bloom causes many problems including fouling of filter media. This study was conducted to find out the way to remove the algae's harmful effects by addition of pre-treatment prior to C/S process. Many Jar-tests were conducted such as (1) ACF (Algae Coagulation Flotation) process using natural algae coagulant (Water $Health^{(R)}$), (2) ACF + C/S process and (3) C/S process with a variety of conditions using cultured algae. The average values of turbidity were (1) 0.42 NTU for ACF process, (2) 0.13 NTU for ACF + C/S process and (3) 0.25 NTU for C/S process. It was shown that the treatment efficiency of ACF process could get low turbidity results, and ACF + C/S process could achieve more efficient results than those of C/S process. Any negative effects of ACF process to the efficiency of C/S process were not observed in ACF + C/S process. In order to reduce the unfavorable effects of algae, it was found out that the introduction of ACF process in the forms of (1) ACF or (2) ACF + C/S could be one of the effective and alternative solutions.

Evaluation of Coagulants Dispersion in Pump Diffusion Mixer for Water Treatment (CFD모사 기법을 이용한 Pump Diffusion Mixer내의 응집체 확산분포에 대한 평가)

  • Park, Young-Oh;Park, No-Suk;Kim, Seong-Su;Kim, Ki-Don;Lim, Kyung-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.1
    • /
    • pp.49-63
    • /
    • 2008
  • The objectives of this research were to evaluate the pressurized/the main inlet water flowrate ratio which have been used as the most important parameter for operating the pump diffusion mixer until now, to suggest the alternative operating parameter and the relating criteria if the flowrate ratio was not inadequate. For the objectives of this research, computational fluid dynamics (CFD) simulation was conducted for 21 cases of flowrate ratio in full-scaled pump diffusion mixer. From the results of CFD simulation, the local velocity gradient values were calculated in each case in order to analyze the simulation results in more detail. For verifying CFD simulation, wet test was conducted. The wet test was to measure the factual coagulant dispersion distribution at a distance of 5.4m from deflector. From both results of CFD simulation and wet test, flowrate ratio was inadequate as operating parameter or criteria, on the other hand the pressurized/the main inlet velocity ratio(dimensionless) was useful in predicting the performance of pump diffusion mixer. Also, the injected coagulant could be dispersed evenly in overall cross section on the condition that pressurized/the main inlet velocity ratio(dimensionless) is over at least 20.

Utilization of Organic Polymers for Improvement of Drinking Water Treatment Process (정수공정 개선을 위한 유기성 Polymer의 사용)

  • Lee, Hwa-Ja;Kim, Jeong-Sook;Kang, Lim-Seok
    • Journal of Environmental Science International
    • /
    • v.7 no.2
    • /
    • pp.217-222
    • /
    • 1998
  • Organics matters including algae are the major contaminants of Nak-dong river and it's concentration Is more Increasing now. The use of coagulants has been Incresed for the effective treatment of drinking water, and aluminum coagulants have been the most widely used in raw water treatment. However, when inorganic metal coagulant is excessively used for long period, it would result in secondary problems, such as increasing sludge production, enhancing the cost of water treatment process, and increasing concentration of residual metal, especially aluminum. Therefore, recently. in order to reduce the use of metal coagulant and enhance the coagulation effectiveness, several alternative coagulants, such as polymeric Inorganic coagulants and organic polymers, have been used In water treatment plants. The objectives of thins research were (11 to determine optimum dosage concentration and compare the coajuiation efnciency at various pH ranees with alum alone, alum+cationic polymer, and alum+anlonlc polymer, (21 to evaluate the amount of alum reduced by using organic polymer, (31 to maximize removal officiency of organic matter and minimize the concentration of residual aluminum.

  • PDF

A Study by Proposal of Efficiency Increase for a Full-scale Wastewater Reclamation Facility using a Biofilter Packed with Granular Sulfur (하수처리수 재이용을 위한 실규모 입상황 생물막여과 시설의 효율증대 방안에 관한 연구)

  • Moon, Jin-Young;Hwang, Yong-Woo;Baek, Seung-Ryun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.1
    • /
    • pp.73-83
    • /
    • 2010
  • This study was performed to increase the removal efficiency of the biofilter packed with granular sulfur in municipal wastewater reclamation facility. Constituent units were influent water tank, denitrification tank, BOD reduction tank and outlet. And, the major operation factor is a biofilter packed with submerged granular sulfur. Actual wastewater and synthetic wastewater were used as influent wastewater. Experimental condition was divided into two phases according to the amount of a phosphorus coagulant. Total phosphorus removal efficiency was insignificant at mode I that phosphorus coagulant was not injected. The average influent and effluent total phosphorus concentrations at mode II were 0.5 ~ 1.0 mg/L and 0.27 mg/L, respectively. As for COD and BOD effluent concentrations, COD was 3.0 mg/L and BOD was 1.0 mg/L. Additionally, nitrogen removal rates were high at low influent DO concentration. In conclusion, a new process, biofilter packed with granular sulfur is expected to treat high-rate nitrogen wastewater and expected to be utilized as an alternative of technological innovation for the nitrogen treatment.