• Title/Summary/Keyword: Alternating electric field

Search Result 78, Processing Time 0.023 seconds

Conductivity Measurements of Submarine Sediments

  • Park, Chan-Hong;Lee, Seung-Hee;Shon, Ho-Woong
    • Journal of the korean society of oceanography
    • /
    • v.36 no.1
    • /
    • pp.1-8
    • /
    • 2001
  • An in-situ four-electrode contact resistivity probe system was designed, and field-tested in submarine sediments. Seismic survey was also performed to support and compare the results of electric survey. The probe was designed to be driven to selected depths below the seafloor using a Vibracore system. The four insulated electrodes were, spaced equidistant across the wedge, were extended beyond the probe tip to minimize effects of sediment disturbance by the wedge insertion. In-situ measurements of resistivity were recorded on board by precision electronic equipment consisting of signal generators and processors, and by temperature-monitoring systems. Overall limits of Uncertainty at respective depths below the seafloor are up to ${\pm}$10 of the measured values. Best estimates of conductivity are considered to be ${\pm}$3 percent of the reported values. Resistivity measurements were made at six sites in carbonate sediments to a maximum depth of penetration of about 5 m. Average values of conductivity range between 0.88 and 1.21 mho/m. The results show the seabed is composed of alternating layers of relatively high-conductivity material (0.8 to 1.4 mho/m) in thicknesses of more or less one meter and layers about 30 cm thick having relatively low conductivities (0.4 to 0.8 mho/m).

  • PDF

Piezoelectric and Dielectric Properties on PSN-PMN-PZT Composition according to CeO2 Addition (PSN-PMN-PZT 조성의 CeO2첨가에 따른 압전.유전특성 변화)

  • Yoon, Man-Soon;Chio, Yong-Gil;Ur, Soon-Chul
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.9
    • /
    • pp.838-842
    • /
    • 2006
  • 0.03Pb$(Sb_{0.5}Nb_{0.5})O_{3}-0.03Pb(Mn{1/3}Nb{2/3)O_{3}-(0.94-x)PbTiO_{3}-xPbZrO_{3}$ ceramics doped with $CeO_{2}$ were synthesized by conventional bulk ceramic processing technique. Phases analysis, microstructures and piezoelectric properties were investigated as a function of $CeO_{2}$ content (0.03, 0.05, 0.1 0.3, 0.5 and 0.7 wt%). Microstructures and phases information were characterized using a scanning electron microscope (SEM) and an X-ray diffractometer (XRD). Mechanical quality factor ($Q_{m}$) and coupling factor(kp) were obtained from the resonance measurement method. Both $Q_{m}$ and $k_{p}$ were shown to reach to the maximum at 0.1 wt% $CeO_{2}$. In order to evaluate the stability of resonance frequency and effective electromechanical coupling factor ($K_{eff}$) as a function of $CeO_{2}$, the variation of resonance and anti-resonance frequency were also measured using a high voltage frequency response analyzer under various alternating electric fields from 10 V/mm to 80 V/mm. It was shown that the stability of resonance frequency and effective electromechanical coupling factor were increased with increasing the $CeO_{2}$ contents.

A Study on the Calculation of Allowable Continuous Current for HVDC Submarine Power Cables (HVDC 해저케이블의 연속허용전류 계산에 관한 연구)

  • Lim, Chung-Hwan;Park, Hung-Sok;Moon, Chae-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.5
    • /
    • pp.815-824
    • /
    • 2022
  • The growing integration of intermittent renewable sources like offshore wind energy increases the need for transferring electric energy over long distances, which may include sea crossings. One of the solutions available for bulk electric power transmission across large distances encompassing wide and deep sea is using HVDC submarine power cables. However, there are no standards or research related to the calculation of the continuous allowable current with various ocean conditions of a DC power cable that does not have an alternating magnetic field. In this study, assuming the typical two types of subsea cable models and two areas of the south coast and the west coast marine conditions, a continuous allowable current simulation of DC cables was performed. As a simulation result, the DC cable continuous allowable current find out the gradient reduction characteristics based on subsea base depth.

AC Loss Characteristic Analysis of Superconducting Power Cable for High Capacity Power Transmission (대용량 전력 전송을 위한 초전도 전력케이블의 교류손실 특성 분석)

  • Lee, Seok-Ju
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.24 no.2
    • /
    • pp.57-63
    • /
    • 2019
  • In order to facilitate the supply of gradually increasing power demand, it is also necessary to increase the number of power cables for power transmission as well as generation facilities. However, the expansion of electric power cables for supplying power to most urban areas requires a space for installation of additional cables, and the space for installing cables in domestic downtown areas is insufficient at present. The superconducting power cable, which can transmit more power with the same size, has emerged as an alternative to overcome the insufficient cable installation space. However, superconducting power cables, which have the advantage of large power transmission, have some losses in the AC (Alternating Current) system. Therefore, the design and analysis of AC losses are essential to introduce superconducting power cables in AC power transmission systems. In this paper, we analyze the AC loss of various superconducting power cables and consider the actual superconducting power cables and their application to the system. Although there is a theoretical calculation method of AC loss for single superconducting wire, it is not easy to calculate AC loss of superconducting power cable with large number. Therefore, the authors intend to analyze various kinds of superconducting power cable AC loss by using electromagnetic finite element analysis considering E-J (Electric field-Current density) characteristics of superconductivity. The analysis of the AC loss characteristics of the superconducting power cable will be an important factor in the design and development of the superconducting power cable to be applied to the actual system.

A study on the growth mechanism of rutile single crystal by skull melting method and conditions of RF generator (스컬용융법에 의한 루틸 단결정 성장메커니즘과 RE generator 조건에 관한 연구)

  • Seok jeong-Won;Choi Jong-Koen
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.15 no.5
    • /
    • pp.175-181
    • /
    • 2005
  • Ingots of rutile single crystals were grown by the skull melting method, and their characteristics were compared in terms of melt-dwelling time for each melt. The method is based on direct inductive heating of an electrically conducted melt by an alternating RF field, and the heating is performed by absorption of RF energy. $TiO_2$ is an insulator at room temperature but its electric conductivity increases elevated temperature. Therefore, titanium metal ring(outside diameter : 6cm, inside diameter : 4cm, thickness 0.2cm) was embedded into $TiO_2$, powder (anatase phase, CERAC, 3N) for initial RF induction heating. Important factors of the skull melting method are electric resistivity of materials at their melting point, working frequency of RF generator and cold crucible size. In this study, electric resitivity of $TiO_2$, $(10^{-2}\~10^{-1}\;{\Omega}{\cdot}m)$ at its melting point was estimated by compairing the electric resitivities of alumina and zirconia. Inner diameter and height of the cold crucible was 11 and 14cm, respectively, which were determined by considering of the Penetration depth $(0.36\~1.13cm)$ and the frequency of RF generator.

A Study on Methodology to Improve the Power Factor of the High Power LED Module (고출력 LED 모듈 역률 개선 방법 연구)

  • Lho, Young Hwan
    • Journal of IKEEE
    • /
    • v.18 no.3
    • /
    • pp.335-340
    • /
    • 2014
  • Recently, LED (Light Emitting Diode) becomes to be useful to apply for the lightening sources in electric systems and the lightening equipment since the power is less consumed with high efficiency, and the size and the weight of LED are small and light, respectively. The LED is controlled with constant current and SMPS (Switching Mode Power Supply). It is necessary for the LED manufacturer to secure the fundamental technology of designing LED chip, and to study the methodology to improve the power factor (PF) and to design the operational circuit for the development of LED to reduce the power loss in the application of LED lightening. The direct AC (Alternating Current) LED driving circuit, HV9910, is widely used in the industry field. In this paper, it is to evaluate the improved methodology for the power factor and efficiency through simulations when PFC (Power Factor Correction) and Noise Filter are added to HV9910.

Effect of Ambient Temperature on the AC Electrical Treeing Phenomena in an Epoxy/Layered Silicate Nanocomposite

  • Park, Jae-Jun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.4
    • /
    • pp.221-224
    • /
    • 2013
  • Effects of ambient temperature on the ac electrical treeing and breakdown behaviors in an epoxy/layered silicate (1 wt%) were carried out in needle-plate electrode geometry. A layered silicate was exfoliated in an epoxy base resin,, using our ac electric field apparatus. To measure the treeing initiation and propagation, and the breakdown rate, constant alternating current (ac) of 10 kV (60 Hz) was applied to the specimen in a needle-plate electrode arrangement, at $30^{\circ}C$, $90^{\circ}C$ or $130^{\circ}C$ of insulating oil bath. At $30^{\circ}C$, the treeing initiation time and the breakdown time in the epoxy/layered silicate (1 wt%) system were 1.4 times higher than those of the neat epoxy resin. At $90^{\circ}C$ (lower than Tg), electrical treeing was initiated in 55 min, and propagated until 1,390 min at the speed of $0.35{\times}10^{-3}mm/min$, which was 4.4 times higher than that at $30^{\circ}C$; however, there was almost no further treeing propagation after 1,390 min. At $130^{\circ}C$ (higher than Tg), electrical treeing was initiated in 44 min, and propagated until 2,000 min at the speed of $0.96{\times}10^{-3}mm/min$. Typical branch type electrical treeing was obtained from the neat epoxy and epoxy/layered silicate at $30^{\circ}C$, while bush type treeing was observed out from the needle tip at $90^{\circ}C$ and $130^{\circ}C$.

Development of a Multichannel Eddy Current Testing Instrument(II) (다중채널 와전류탐상검사 장치 개발(II))

  • Lee, Hee-Jong;Nam, Min-Woo;Cho, Chan-Hee;Yoo, Hyun-Joo;Kim, In-Chel
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.5
    • /
    • pp.552-559
    • /
    • 2011
  • Recently, the eddy current testing(ECT), alternating current field testing, magnetic flux leakage testing and remote field testing have been used as a nondestructive evaluation method based on the electromagnetic induction phenomenon. The eddy current testing is now widely accepted as a NDE method for the heat exchanger tube in the electric power industry, chemical, shipbuilding, and military. The ECT system mainly consists of the synthesizer module, analog module, analog-to-digital converter, power supplier, and data acquisition and analysis program. In the previous study, the synthesizer module and the analog module which is essential to the ECT system were primarily developed, and in this study the data acquisition and analysis program were developed. The operation system for this program is based on the Windows 7, and optimized for the Korean users, and the specific feature of this program using setup wizard enables inspector to make a setup easily for acquisition and analysis of ECT data. In this paper, the configuration and functions of eddy current data acquisition and analysis program will be introduced.