• 제목/요약/키워드: Alternating current

검색결과 392건 처리시간 0.024초

A Controllable LCL-T Resonant AC/DC Converter for High Frequency Power Distribution Systems

  • Zeng, Jun;Li, Xuesheng;Liu, Junfeng
    • Journal of Power Electronics
    • /
    • 제15권4호
    • /
    • pp.876-885
    • /
    • 2015
  • High frequency alternating current (HFAC) has been widely used in a wide range of power distribution systems (PDS) due to its superior performance. A high frequency AC/DC converter plays the role of converting HFAC voltage to DC voltage. In this paper, a new LCL-T resonant AC/DC converter has been proposed, and an easier control method based on input voltage comparison is presented, without the complicated calculation of the zero-crossing point. Both a low distortion and near-to-unity power factor can be achieved by the proposed resonant converter and control strategy. The operational principle and steady-state analysis are given for the proposed resonant converter. A simulation model and experimental prototype are implemented with an operation frequency of 25kHz and a rated power of 20W. The simulation and experimental results verify the accuracy of the analysis and the excellent performance of the proposed topology.

가스배관의 교류부식 특성에 관한 연구 (A Study on the Characteristics for AC Corrosion of Gas Pipelines)

  • 배정효;하태현;이현구;김대경
    • 한국가스학회지
    • /
    • 제5권3호
    • /
    • pp.29-35
    • /
    • 2001
  • $\cdot$방식분야에서 직류부식은 많이 연구되어 왔지만, 교류부식은 직류에 비래 부식률이 매우 낮다는 이유로 소홀히 연구되어 왔다. 그러나 최근 유럽을 비롯한 북미에서도 교류부식에 의한 사고가 빈발하게 발생하기 시작하였다. 따라서 본 논문에서는 가스배관의 교류부식에 대한 특성을 실험실 시험과 현장에서의 실 사례 연구를 통하여 규명하였다.

  • PDF

교류 순방향 바이어스에 따른 형광 OLED의 전계 발광 특성 (Electroluminescent Characteristics of Fluorescent OLED with Alternating Current Forward Bias)

  • 서정현;주성후
    • 한국표면공학회지
    • /
    • 제50권5호
    • /
    • pp.398-404
    • /
    • 2017
  • In order to study the AC driving mechanism for OLED lighting, the fluorescent OLEDs were fabricated and the electroluminescent characteristics of the OLEDs by AC forward bias were analyzed. In the case of the driving method of OLED by AC forward bias under the same voltage and the same current density, degradation of luminescent characteristics for elapsed time progressed faster than in the case of the driving method by DC bias. These phenomena were caused by the peak voltage of AC forward bias which is ${\sqrt{2}}$ times higher than the DC voltage. In addition, the degradation of the OLED was accelerated because the AC forward bias had come close to the upper limit of the allowable voltage range even though the peak voltage didn't exceed the allowable range of the OLED. However, the fabricated fluorescent OLED showed little degradation of OLED characteristics due to AC forward bias from 0 V to 6.04 V. Therefore, OLED lighting by AC driving will become commercialized if sufficient luminance is realized at a voltage at which the characteristics of the OLED are not degradation by the AC driving method.

교류고압전계요법이 뇌졸중환자의 말초혈류 및 재활기능에 미치는 효과에 대한 임상연구 (The Clinical Effect of High Voltage AC Reid Therapy(HEALTHTRON) on Peripheral Circulatory Disturbance and Functional Outcome of Rehabilitation in CVA Patients)

  • 성강경;황충연;이상관;이소영;정상수;강세영;이종덕
    • 동의생리병리학회지
    • /
    • 제16권3호
    • /
    • pp.609-615
    • /
    • 2002
  • A medical treatment of alternating current high-voltage electric field therapy is a method in which we get a healing effect, applying electric field to an organism through an artificial device. In order to estimate the clinical effects of alternating current high-voltage electric field load(HEALTHTRON) on the rehabilitation of stroke patients, improvement of a peripheral blood circulation, and psychogenic symptom, we used BEUNZEUNGHEYNG Instrument, NIHSS(the National Institutes of Health Stroke Scale), FIM(Functional Independence Measure)lnstrument to research BEUNZEUNGHEYNG and recovery of rehabilitative funation. and also we used Thermography, Pulse Meter to measure body temperature and pulse, blood elements, and neuro modulators. We have reached the following conclusions after researching the clinical effects of alternating current high-voltage electric field therapy on the recovery of rehabilitative function and peripheral blood circulation. 1. HEALTHTRON efficiently has increased the volume of peripheral blood circulation in stroke patients. 2. HEALTHTRON rapidly has treated the symptoms of sleeplessness, alertness, and dizziness of stroke patients. 3. HEALTHTRON rapidly has improved rehabilitative function of stroke patients and the adjustment to their activities.