• 제목/요약/키워드: Alternating Magnetic Fields

검색결과 24건 처리시간 0.017초

Bluetooth Low-Energy Current Sensor Compensated Using Piecewise Linear Model

  • Shin, Jung-Won
    • 센서학회지
    • /
    • 제29권5호
    • /
    • pp.283-292
    • /
    • 2020
  • Current sensors that use a Hall element and Hall IC to measure the magnetic fields generated in steel silicon core gaps do not distinguish between direct and alternating currents. Thus, they are primarily used to measure direct current (DC) in industrial equipment. Although such sensors can measure the DC when installed in expensive equipment, ascertaining problems becomes difficult if the equipment is set up in an unexposed space. The control box is only opened during scheduled maintenance or when anomalies occur. Therefore, in this paper, a method is proposed for facilitating the safety management and maintenance of equipment when necessary, instead of waiting for anomalies or scheduled maintenance. A Bluetooth 4.0 low-energy current-sensor system based on near-field communication is used, which compensates for the nonlinearity of the current-sensor output signal using a piecewise linear model. The sensor is controlled using its generic attribute profile. Sensor nodes and cell phones used to check the signals obtained from the sensor at 50-A input currents showed an accuracy of ±1%, exhibiting linearity in all communications within the range of 0 to 50 A, with a stable output voltage for each communication segment.

HFCT를 활용한 고전압직류송전 케이블 부분방전 위치추정 (Detection and localization of partial discharge in high-voltage direct current cables using a high-frequency current transformer)

  • 홍선민;손우영;천혜원;강대경;박종후
    • 센서학회지
    • /
    • 제30권2호
    • /
    • pp.105-108
    • /
    • 2021
  • Detection and localization of partial discharge are considered critical techniques for estimating the lifetimes of power cables. High-frequency current transformers (HFCTs) are commonly used for the detection of partial discharge in high-voltage alternating current (HVAC) power cables; however, their applicability is compromised by the limitations of the installation locations. HFCTs are typically installed in cable terminals or insulation joint boxes because HVACs induce strong time-varying magnetic fields around the cables, saturating the ferromagnetic materials in the HFCTs. Therefore, partial discharges near the installation locations can be detected. In this study, the feasibility of partial discharge detection using a HFCT was investigated for high-voltage direct current (HVDC) cables. We demonstrated that the HFCT could be installed at any location in the HVDC power cable to monitor partial discharge along the entire cable length. Furthermore, we showed that the HFCT could detect the location of partial discharge with high accuracy.

의성지역 백악기 암석에 대한 고자기 연구 (Palaeomagnetism of Cretaceous Rocks in the Ǔisǒng Area, Kyǒngsang Basin, Korea)

  • 김인수;이현구;윤혜수;강희철
    • 자원환경지질
    • /
    • 제26권3호
    • /
    • pp.403-420
    • /
    • 1993
  • The Cretaceous Kyongsang Basin is known to be composed of several tectonic blocks (or subbasins) with each distinct stratigraphic succession. The study area represents a major part of one of these blocks, i. e. the $\check{U}is\check{o}ng$ block. The area is charaterized by a suite of WNW-trending sinistral strike-slip faults as well as a number of ring faults. A total of 292 independently oriented core samples were drilled from 23 sites, covering virtually all the formations of the Cretaceous $Ky\check{o}ngsang$ Supergroup. Alternating field and thermal demagnetization experiments were conducted to reveal the primary magnetization. Due to the homoclinal nature of the strata in the area, it was not possible to make use of the conventional fold test It is, however, believed that the primary remanent components have been obtained from the majority of the formations, considering the similarity of the palaeomagnetic pole positions with those of contemporary strata of other blocks and the existence of antiparallel reversed remanence. It was found neither any significant difference in magnetic declination on each side of the strike-slip faults nor systematic change of magnetic declination with distance from the fault-line. This does not support such a block rotation hypothesis associated with the strike-slip faulting in the area as alleged by some authors. The samples from the outcrops on or near the fault-lines were severely overprinted by the recent magnetic fields regardless of age and lithology. Epithermal Au-Ag-Cu-Pb-Zn mineralizations are known along some fault lines in the area. It is interpreted that these two facts are closely related with fluid circulations along the fracture zones caused by fault activities. In regard to the age of the strata as deduced from the magnetostratigraphic consideration, the $Ch\check{o}mgok$ formation and the lower strata should be older than Barremian or 124 Ma. The age of volcanics of the $Yuch^{\prime}\check{o}n$ Group sampled in this study should be younger than Campanian or 83 Ma.

  • PDF

과전류 보호계전기용 광섬유 전류센서 (Fiber-Optic Current Transformer for the Over Current Protection Relay)

  • 송민호;양창순;안성준;박병석;이병호
    • 비파괴검사학회지
    • /
    • 제21권5호
    • /
    • pp.542-548
    • /
    • 2001
  • 과전류 보호계전기에 사용할 목적으로 광섬유를 센서헤드로 사용하는 광 전류센서를 구성하였다. 전류측정의 원리는 도체 주변에 감겨진 광섬유 코일을 따라 광신호의 선형편광축이 자기장에 의하여 회전하는 정도를 측정하여 이로부터 전류의 값을 산출하는 편광측정 방법이 사용되었다. 센서코일은 $10/125{\mu}m$ 규격의 일반 통신용 광섬유를 미터당 20회전 이상 비틀어 제작하여 온도나 진동 등의 환경적 영향을 최소화하였다. 코일의 한쪽 끝은 Faraday Rotator Mirror를 장착한 반사형으로 설계하여 계통을 해체하지 않은 상태에서도 센서의 탈 부착이 가능하고 코일의 회전수에 따라 센서의 민감도 조절이 용이하며 폐회로형 구조이므로 인근 신호원에 의한 간섭을 차단할 수 있다. 편광 빛가르개 등을 이용한 광학 신호처리부를 구성하고 표준 전류원을 이용한 전류측정 실험을 수행한 결과로 이론적인 해석과 동일한 형태의 출력을 얻을 수 있었다. 본 논문에서는 구성한 광 전류센서의 이론적 모델을 기술하고 전류측정 실험의 결과와 이론치에 대하여 비교 분석한다.

  • PDF