• Title/Summary/Keyword: Alpha track analysis

Search Result 18, Processing Time 0.025 seconds

Cytotoxicity of Diesel Exhaust Particles from Various Vehicles toward Macrophage Cells (국내 디젤 차량 배기 입자가 쥐 대식세포에 미치는 세포독성 평가)

  • Lee, Jang-Han;Lee, Yong-Kwon;Lee, Ji-Young;Lee, Seung-Bok;Kim, Sun-Hwa;Bae, Gwi-Nam;Lee, Hak-Sung;Lim, Cheol-Soo;Chung, Nam-Hyun
    • Environmental Analysis Health and Toxicology
    • /
    • v.25 no.2
    • /
    • pp.111-120
    • /
    • 2010
  • DEPs (diesel exhaust particles) like any other particles can be also inhaled into lung to participate in a damaging reaction to the organ. Possible damages might be apoptosis and inflammatory responses to the cells in respiratory track. The aim of this study was cytotoxicity evaluation of DEPs from five in-use diesel vehicles using a murine macrophage cell (RAW 254.7). We found that most DEPs have a considerable cytotoxicity compared to the control and SRM 2975. When measured by MTT assay and extents of apoptosis, DEPs of two highmileage vehicles had higher toxicity than those of the other three low-mileage vehicles tested. Although mRNA expression level of TNF-${\alpha$ somewhat explains the trend of cytotoxicity and apoptosis, that of IL-1$\beta$ did not. Correlation studies among the extents of MTT assay, apoptosis, and TNF-$\alpha$ expression showed that the extents between apoptosis and TNF-$\alpha$ expression was most highly correlated (r=0.96). These results suggest that cytotoxicity of various DEPs could be compared easily by measuring the extent of apoptosis or TNF-$\alpha$ expression by DEPs.

Comparative studies of various transfection processes for the optimal luminescence signal analysis (최적의 luminescence 신호 분석을 위한 유전자 전달 방법의 비교연구)

  • Park, Seohyun;Lee, Sunghou
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.640-647
    • /
    • 2016
  • By minimizing fluorescence interference phenomena, aequorin-based luminescence technology can provide a relatively sensitive detection platform with integration of $G{\alpha}16$ protein in order to track internal calcium mobilization by G protein-coupled receptors (GPCR). In this type of cell-based functional assay format, it is essential to optimize the transfection process of a receptor and $G{\alpha}16$ protein. For this study, corticotropin releasing factor receptor subtype 2(CRF2) was set as a model system to generate three stable cells with CRF2 and $G{\alpha}16$ in addition to transiently transfected cells under three different conditions. Agonist (sauvagine) and antagonist (K41498) responses in those cells were analyzed to develop the optimum transfection process. As a result, the effective signal ratio in the dose response experiments of sauvagine and K41498 were at least 10-fold higher (z'=0.77) in CRF2-$G{\alpha}16$ stable cells. For the transient transfection cells, stable expression of $G{\alpha}16$ prior to the CRF2 represented a two-fold higher signal (z'=0.84) than the other cases of transient transfection. In conclusion, for the utilization of transient transfection processes to develop a cell-based GPCR functional assay system, it is suggested to introduce various target receptors after stable expression of $G{\alpha}16$ protein.

How to Enhance Perceived Usefulness, Ease of Use, and Fit of Wearables: An Exploratory Study about the Physical Attributes of Smart Wristbands and Smartwatches

  • Shim, Soo In;Yu, Heejeong
    • International Journal of Advanced Culture Technology
    • /
    • v.11 no.4
    • /
    • pp.302-309
    • /
    • 2023
  • Wearable devices, attached to the human body, track and enhance users' activities, health, and communication. Therefore, considering ergonomic factors in product design is crucial. However, previous research has somewhat overlooked the importance of integrating ergonomic design elements into a broad spectrum of design factors. This study aims to examine the impact of physical attributes inherent in smart wristbands and smartwatches on the perceived functional value, specifically, perceived usefulness, ease of use, and fit. A survey was conducted among 289 US adults who had experience using smart wristbands or smartwatches. The collected data were analyzed using descriptive statistics, factor analysis, Cronbach's alpha, t-test, MANOVA, and regression analysis in SPSS version 29. The results showed that the shape of the front display significantly influenced perceived ease of use, and the product's weight had a substantial impact on both perceived ease of use and fit. Furthermore, distinct technical features on the front display had varied effects on perceived usefulness, ease of use, and fit. Notably, the presence of activity tracking, alarm, and calendar functionalities led to distinct differences in ease of use and fit. Features such as distance tracking, phone call, social media notifications, text messaging, and time display functions showed significant influences on the perception of fit. These findings provide insights into the physical values of smart wristbands and smartwatches as perceived by users.

Effects of Low Power Laser Irradiation on the Spinal Cord for the Functional Regeneration of Crushed Sciatic Nerve in Rats (흰쥐 좌골신경 압좌손상 후 척수분절의 저강도 레이저 조사가 운동기능 회복에 미치는 영향)

  • Kim, Souk-Boum;Kim, Dong-Hyun;Song, Ju-Min;Nam, Ki-Won;Kwon, Young-Shil;Kim, Jin-Sang
    • The Journal of Korean Physical Therapy
    • /
    • v.13 no.3
    • /
    • pp.569-578
    • /
    • 2001
  • The purpose of the present study was to examine the functional recovery of the crushed sciatic nerve of rats after low-power laser irradiation applied to the corresponding segments of the spinal cord. After a crushed injury on the left sciatic nerve in rats. low-power laser irradiation was applied transcutaneously to corresponding segments of the spinal cord immediately after suture the wound by using 2000 mW, 2000Hz, 830 nm CaAIAs(Gallium-aluminum-arsenide) semiconductor diode laser. The laser treatment was performed with 10 minutes daily for 4 successive weeks. Functional recovery was evaluated per weekly following injury by sciatic function index(SFI),using data obtained by walking track analysis. For four weeks after crush injury, experimental group had significantly greater functional improvement than control group(${\alpha}$=0.05). In a experimental group, SFI was significantly increased for three weeks, but control group not increased for two weeks. This study suggests that low-power laser irradiation applied directly to the spinal cord can improve functional recovery of the crushed sciatic nerve in rats.

  • PDF

Kinematic Analysis of Mid-Race in Men's 100-m Final during IAAF World Championships, Daegu 2011 (2011 대구세계육상선수권대회 100 m 남자 결승전 중간질주구간의 운동학적 분석)

  • Ryu, Ji-Seon;Ryu, Jae-Kyun;Kim, Tae-Sam;Park, Young-Jin;Hwang, Won-Seob;Yoon, Suk-Hoon;Park, Sang-Kyoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.5
    • /
    • pp.511-520
    • /
    • 2011
  • The purpose of this study was to provide scientific information to track and field coaches and athletes through the analyses of the biomechanics characteristics of the top 4 sprinters in the men's 100 m final in the IAAF World Championships Daegu 2011. Twelve video cameras (Sony, Japan) were used to capture the mid portion of the race (40 m - 70 m) with a sampling frequency of 60Hz. Biomechanical variables including the right ankle, knee and hip angles, the trunk angle, and the velocity of center of mass (COM) in the running direction, were calculated with the Kwon 3D program (Visol, Korea). Correlation coefficients between the COM velocity and each variables were calculated using Matlab 2008a (MathWorks, USA) at an alpha level of 0.05. The findings indicated that Yohan Blake (JAM) showed greater range of motion at the ankle and hip. Walter Dix(USA) showed greater knee and trunk movement, and Kim Collins (SKN) showed more dorsi-flexed and extended trunk angles during the race. Finally, Christophe Lemaitre (FRA) showed more plantar-flexed ankle with a less trunk motion, throughout the analyzed race.

Effects of nitrogen doping on mechanical and tribological properties of thick tetrahedral amorphous carbon (ta-C) coatings (질소 첨가된 ta-C 후막코팅의 기계 및 트라이볼로지적 특성연구)

  • Gang, Yong-Jin;Jang, Yeong-Jun;Kim, Jong-Guk
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.156-156
    • /
    • 2016
  • The effect of nitrogen doping on the mechanical and tribological performance of single-layer tetrahedral amorphous carbon (ta-C:N) coatings of up to $1{\mu}m$ in thickness was investigated using a custom-made filtered cathode vacuum arc (FCVA). The results obtained revealed that the hardness of the coatings decreased from $65{\pm}4.8GPa$ to $25{\pm}2.4GPa$ with increasing nitrogen gas ratio, which indicates that nitrogen doping occurs through substitution in the $sp^2$ phase. Subsequent AES analysis showed that the N/C ratio in the ta-C:N thick-film coatings ranged from 0.03 to 0.29 and increased with the nitrogen flow rate. Variation in the G-peak positions and I(D)/I(G) ratio exhibit a similar trend. It is concluded from these results that micron-thick ta-C:N films have the potential to be used in a wide range of functional coating applications in electronics. To achieve highly conductive and wear-resistant coatings in system components, the friction and wear performances of the coating were investigated. The tribological behavior of the coating was investigated by sliding an SUJ2 ball over the coating in a ball-on-disk tribo-meter. The experimental results revealed that doping using a high nitrogen gas flow rate improved the wear resistance of the coating, while a low flow rate of 0-10 sccm increased the coefficient of friction (CoF) and wear rate through the generation of hematite (${\alpha}-Fe_2O_3$) phases by tribo-chemical reaction. However, the CoF and wear rate dramatically decreased when the nitrogen flow rate was increased to 30-40 sccm, due to the nitrogen inducing phase transformation that produced a graphite-like structure in the coating. The widths of the wear track and wear scar were also observed to decrease with increasing nitrogen flow rate. Moreover, the G-peaks of the wear scar around the SUJ2 ball on the worn surface increased with increasing nitrogen doping.

  • PDF

Determine the hazards of radioactive elements and radon gas manufacturing processes in an Egyptian fertilizer factory

  • Soad Saad Fares
    • Nuclear Engineering and Technology
    • /
    • v.56 no.5
    • /
    • pp.1781-1795
    • /
    • 2024
  • This study investigated the levels of radioactivity in soil surrounding a phosphate fertilizer factory in Egypt, aiming to assess potential risks to the population exposed to radiation. Concentrations of 238U, 226Ra, 232Th, and 40K were measured in soil samples collected from two subsites: one near the factory (subsite 1) and another further away (subsite 2). Two different systems were used for measuring radioactivity, a high-purity gamma ray spectroscopy system with an HPGe detector for gamma-emitting isotopes and a CR-39 solid nuclear track detector for alpha-emitting radon gas. Subsite 1, located close to the factory, displayed significantly elevated levels of 226Ra compared to global background levels (514 and 456 Bq/kg vs. 35 Bq/kg). Additionally, the concentrations of 238U (241.06 Bq/kg vs. global average 35 Bq/kg), 232Th (16.15 Bq/kg vs. global average 30 Bq/kg), and 40K (146.36 Bq/kg vs. global average 400 Bq/kg) were all above global averages. Furthermore, a high concentration of radon gas (337.06 μSv/y) was measured at subsite 1. The strong positive correlation observed between 226Ra and 238U (0.96256) provides further evidence of potentially elevated radioactivity levels near the factory. In contrast, subsite 2, situated farther from the factory, exhibited natural radioactive background levels within international limits. Quantitative analysis revealed that gamma ray absorbed doses for 226Ra and 232Th exceeded global averages in some samples. Specifically, 226Ra doses ranged from 7.8 to 46.26 ppm (exceeding the 20 ppm global average in some cases), and 232Th doses ranged from 1.98 to 9.14 ppm (exceeding the 10 ppm global average in some cases). The concentration of 40K, however, remained within the global range (0.07%-0.69 %). The observed imbalances in the ratios of Th/U (0.17-0.24 Bq/kg and 0.73-0.24 ppm) and U/Ra (0.81-0.73 Bq/kg and 0.73-0.17 ppm), both of which are significantly lower than their respective global averages of 4 and 2.4, point towards the presence of fertilizer-derived contamination. This conclusion is further supported by the high phosphate concentrations detected in the samples. Overall, this study suggests that radioactive contamination near the phosphate fertilizer factory significantly exceeds global background levels and international limits in some cases. This raises concerns about potential risks posed to surrounding agricultural land and crops.

In vitro evaluation of the wear resistance of provisional resin materials fabricated by different methods (제작방법에 따른 임시 수복용 레진의 마모저항성에 관한 연구)

  • Ahn, Jong-Ju;Huh, Jung-Bo;Choi, Jae-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.110-117
    • /
    • 2019
  • Purpose: This study was to evaluate the wear resistance of 3D printed, milled, and conventionally cured provisional resin materials. Materials and methods: Four types of resin materials made with different methods were examined: Stereolithography apparatus (SLA) 3D printed resin (S3P), digital light processing (DLP) 3D printed resin (D3P), milled resin (MIL), conventionally self-cured resin (CON). In the 3D printed resin specimens, the build orientation and layer thickness were set to $0^{\circ}$ and $100{\mu}m$, respectively. The specimens were tested in a 2-axis chewing simulator with the steatite as the antagonist under thermocycling condition (5 kg, 30,000 cycles, 0.8 Hz, $5^{\circ}C/55^{\circ}C$). Wear losses of the specimens were calculated using CAD software and scanning electron microscope (SEM) was used to investigate wear surface of the specimens. Statistical significance was determined using One-way ANOVA and Dunnett T3 analysis (${\alpha}=.05$). Results: Wear losses of the S3P, D3P, and MIL groups significantly smaller than those of the CON group (P < .05). There was no significant difference among S3P, D3P, and MIL group (P > .05). In the SEM observations, in the S3P and D3P groups, vertical cracks were observed in the sliding direction of the antagonist. In the MIL group, there was an overall uniform wear surface, whereas in the CON group, a distinct wear track and numerous bubbles were observed. Conclusion: Within the limits of this study, provisional resin materials made with 3D printing show adequate wear resistance for applications in dentistry.