• 제목/요약/키워드: Alloy surface

검색결과 2,647건 처리시간 0.029초

Determination of Adsorption Isotherms of Hydrogen on Zirconium in Sulfuric Acid Solution Using the Phase-Shift Method and Correlation Constants

  • Chun, Jang-H.;Chun, Jin-Y.
    • 전기화학회지
    • /
    • 제12권1호
    • /
    • pp.26-33
    • /
    • 2009
  • The phase-shift method and correlation constants, i.e., the unique electrochemical impedance spectroscopy (EIS) techniques for studying the linear relationship between the behavior ($-{\varphi}$ vs. E) of the phase shift ($90^{\circ}{\geq}-{\varphi}{\geq}0^{\circ}$) for the optimum intermediate frequency and that ($\theta$ vs. E) of the fractional surface coverage ($0{\leq}{\theta}{\leq}1$), have been proposed and verified to determine the Langmuir, Frumkin, and Temkin adsorption isotherms of H and related electrode kinetic and thermodynamic parameters at noble metal (alloy)/aqueous solution interfaces. At a Zr/0.2 M ${H_2}{SO_4}$ aqueous solution interface, the Frumkin and Temkin adsorption isotherms ($\theta$ vs. E), equilibrium constants (K = $1.401{\times}10^{-17}\exp(-3.5{\theta})mol^{-1}$ for the Frumkin and K = $1.401{\times}10^{-16}\exp(8.1{\theta})mol^{-1}$ for the Temkin adsorption isotherm), interaction parameters (g = 3.5 for the Frumkin and g = 8.1 for the Temkin adsorption isotherm), rates of change of the standard free energy (r = $8.7\;kJ\;mol^{-1}$ for g = 3.5 and r = $20\;kJ\;mol^{-1}$ for g = 8.1) of H with $\theta$, and standard free energies ($96.13{\leq}{\Delta}G^0_{\theta}{\leq}104.8\;kJ\;mol^{-1}$ for K = $1.401{\times}10^{-17}\exp(-3.5{\theta})mol^{-1}$ and $0{\leq}{\theta}{\leq}1$ and ($94.44<{\Delta}G^0_{\theta}<106.5\;kJ\;mol^{-1}$ for K = $1.401{\times}10^{-16}\exp(-8.1{\theta})mol^{-1}$ and $0.2<{\theta}<0.8$) of H are determined using the phase-shift method and correlation constants. At 0.2 < $\theta$ < 0.8, the Temkin adsorption isotherm correlating with the Frumkin adsorption isotherm, and vice versa, is readily determined using the correlation constants. The phase-shift method and correlation constants are probably the most accurate, useful, and effective ways to determine the adsorption isotherms of H and related electrode kinetic and thermodynamic parameters at highly corrosion-resistant metal/aqueous solution interfaces.

증류수 및 NaCl 용액내 SnPb 솔더 합금의 Electrochemical Migration 우세 확산원소 분석 (Dominant Migration Element in Electrochemical Migration of Eutectic SnPb Solder Alloy in D. I. Water and NaCl Solutions)

  • 정자영;이신복;유영란;김영식;주영창;박영배
    • 마이크로전자및패키징학회지
    • /
    • 제13권3호
    • /
    • pp.1-8
    • /
    • 2006
  • 인쇄회로기판이나 플라스틱 패키지 등 다양한 전자소자 부품내 배선간 간격이 갈수록 좁아짐에 따라 최근 많이 발생하고 있는 electrochemical migration(ECM) 현상은 양극에서 이온화된 금속에 의한 conductive anodic filament(CAF) 및 덴드라이트와 같은 전도성 필라멘트의 성장으로 인해 전자부품의 절연파괴를 일으키고 있다. 본 연구에서는 공정조성 Sn-37Pb솔더 합금의 ECM 거동과 부식특성 사이의 연관성 평가를 통해 ECM 우세원소를 파악하기 위해 D.I Water 및 NaCl 용액에서 Water Drop Test(WDT)와 분극실험을 실시하여 서로 비교하였다. WDT 실시 결과 공정조성 Sn-37Pb 솔더 합금에서 Pb-rich 상이 Sn-rich 상보다 우선적으로 양극 패드에서 녹아나서 상대적으로 ECM 저항성이 낮았으며, 음극패드에서 자라난 덴드라이트에도 Pb가 훨씬 많이 존재하였다. NaCl에서의 분극실험 결과 전기화학적으로 부동태 피막을 형성하는 Sn에 비해 Pb의 부식속도가 크게 나타났으며, WDT의 결과와 같은 경향을 보였다. 따라서 공정조성 SnPb 솔더 합금의 부식저항성과 ECM 저항성 사이에는 좋은 상관관계가 존재한다.

  • PDF

Ni기 초내열합금 GTD 111의 크리프 파단에 미치는 미세조직의 영향 (Study on the Relationship Between Microstructure and Creep-Rupture Behavior of GTD 111)

  • 신현종;김인수;이재현;허성강;조창용
    • 한국재료학회지
    • /
    • 제11권1호
    • /
    • pp.8-14
    • /
    • 2001
  • Ni기 초내열합금 GTD 111의 미세조직의 변화와 크리프 파단특성에 대해 연구하였다. 조직관찰을 통해 본 합금의 응고거동과 주조 후 응고과정에서 석출거동을 분석하였다. MC탄화물의 생성위치가 $\gamma$/$\gamma$' 상 보다 수지상 중심에서 가까운 것으로 MC탄화물이 $\gamma$/$\gamma$'공정상보다 먼저 응고된 것을 확인할 수 있었다. $\eta$상은 Ti가 많은 $\gamma$'상에서 변태되어 형성되었으며, $\gamma$/$\gamma$'공정상에서 η상으로의 변태에 따라 $\eta$상 근처에 PFZ가 형성되고 PFZ 내부에 TaC가 석출됨을 확인하였다. $871^{\circ}C$이상의 온도에서 크리프 파단은 결정입계를 따라 진행되는 것이 명확하였으며, 표면에서 형성된 균열과 내부에서 생성된 균열이 전파, 조합되어 최종파단을 초래하였다. 결정입계 균열의 생성은 최종응시 형성된 미세공동과 밀접한 관계가 있는 것으로 분석되었으며, $\eta$상과 PFZ는 균열 생성에 큰 영향을 주지 않았다.

  • PDF

과학적 분석을 통한 전세품 청동기의 진위판별 적용 가능성 연구 (Applicability for Authenticity of Bronze Artefacts using Scientific Analyses)

  • 도미솔;정광용
    • 보존과학회지
    • /
    • 제29권4호
    • /
    • pp.355-366
    • /
    • 2013
  • 전세품인 청동기를 대상으로 ICP-AES, SEM-EDS와 두 종류의 P-XRF (Bench top type, Gun type)를 이용하여 성분분석과 미세조직 관찰을 실시하였다. 또한 전세품 청동기의 성분 함유량을 분석하는 과학적 분석을 이용하여 특이원소의 검출에 따른 청동기의 진위 판별에 대한 적용성 연구를 실시하였다. ICP-AES의 분석 결과 청동기는 3원 합금(Cu-Sn-Pb계)의 청동으로 Ag, As, Co, Fe 등의 미량 성분이 검출되었으며 특이 원소(Zn 등)는 검출되지 않았다. P-XRF 분석결과 ICP-AES 분석결과와 비교하였을 때 Cu의 함유량은 10~25% 낮고, Sn 함유량은 10~20% 높게 검출되었다. 이는 탈주석 현상으로 Sn의 함유량이 높은 산화주석($SnO_2$) 화합물이 청동기 표면에 존재하여 영향을 주는 것으로 판단되었다. 그리고 SEM-EDS 분석결과 Pb의 편석 현상을 확인할 수 있었다. 이러한 과학적 분석 방법을 이용하여 청동 소지층과 부식층(표면)의 성분 조성 관계가 서로 다르게 나타나는 것을 확인하였다. 청동유물은 미세조직 및 성분분석 결과만으로 진위판별에 대한 결과를 적용하기가 어려웠다. 따라서 매장 환경 및 유물의 보존 상태 등에 따라 부식생성물질이 서로 다른 양상을 보이는 것에 착안하여 부식생성물질에 대한 추가적인 연구와 고고미술사적인 비교연구를 통하여 진위여부를 확인할 수 있을 것으로 사료된다.

하악 구치부에서 임플랜트 배열방식에 따른 임플랜트지지 고정성 국소의치의 광탄성 응력 분석 (PHOTOELASTIC STRESS ANALYSIS OF IMPLANT SUPPORTED FIXED PROSTHESES WITH DIFFERENT PLACEMENT CONFIGURATIONS IN MANDIBULAR POSTERIOR REGION)

  • 조혜원;김난영;김유리
    • 대한치과보철학회지
    • /
    • 제43권1호
    • /
    • pp.120-131
    • /
    • 2005
  • Statement of problem. More than 70% of patients who need the implant supported restoration are parially edentulous. The principles of design for implant supported fixed partial denture in mandibular posterior region are many and varied. Jurisdiction for their use is usually based on clinical evaluation. There are several areas or interest regarding the design of implant supported fixed partial denture in mandibular posterior region. 1) Straight and tripod configuration in implant placement, 2) Two restoration types such as individualized and splinted restorations. Purpose. The purpose of this study was to compare the amount and distribution of stress around the implant fixtures placed in the mandibular posterior region with two different arrangements and to evaluate the effects of splinting using the photoelastic stress analysis. Material & methods. 1) Production of study model: Mandibular partially edentulous model was waxed-up and duplicated with silicone and two models were poured in stone. 2) Fixture installation and photoelastic model construction: Using surveyor(Ney, USh), 3 fixtures(two 4.0 $\times$13 mm, one 5.0$\times$10 mm, Lifecore, USA) were insta)led in straight & tripod configurations. Silicone molds were made and poured in photoelastic resin (PL-2. Measurements group, USA). 3) Prostheses construction: Four 3-unit bridges (Type III gold alloy, Dongmyung co., Korea) were produced with nonhexed and hexed UCLA abutments and fitted with conventional methods. The abutments were tightened with 30 Ncm torque and the static loads were applied at 12 points of the occlusal surface. 4) Photoelastic stress analysis : The polarizer analyzer system with digital camera(S-2 Pro, Fujifilm, Japan) was used to take the photoelastic fringes and analysed using computer analysis program. Results. Solitary hexed UCLA restoration developed different stress patterns between two implant arrangement configurations, but there were no stress transfer to adjacent implants from the loaded implant in both configurations. However splinted restorations showed lesser amount of stresses in the loaded implants and showed stress transfer to adjacent implants in both configurations. Solitary hexed UCLA restoration with tripod configuration developed higher stresses in anterior and middle implants under loading than implants with straight configurations. Splintied 3 unit fixed partial dentures with tripod configuration showed higher stress development in posterior implant under loading but there were no obvious differences between two configurations. Conclusions. The tripod configuration of implant arrangement didn't show any advantages over the straight configuration. Splinting of 3 unit bridges with nonhexed UCLA abutments showed less stress development around the fixtures. Solitary hexed UCLA restoration developed tilting of implant fixture under offset loads.

Development of Continuous Galvanization-compatible Martensitic Steel

  • Gong, Y.F.;Song, T.J.;Kim, Han S.;Kwak, J.H.;De Cooman, B.C.
    • Corrosion Science and Technology
    • /
    • 제11권1호
    • /
    • pp.1-8
    • /
    • 2012
  • The development of martensitic grades which can be processed in continuous galvanizing lines requires the reduction of the oxides formed on the steel during the hot dip process. This reduction mechanism was investigated in detail by means of High Resolution Transmission Electron Microscopy (HR-TEM) of cross-sectional samples. Annealing of a martensitic steel in a 10% $H_2+N_2$ atmosphere with the dew point of $-35^{\circ}C$ resulted in the formation of a thin $_{C-X}MnO.SiO_{2}$ (x>1) oxide film and amorphous $_{a-X}MnO.SiO_{2}$ oxide particles on the surface. During the hot dip galvanizing in Zn-0.13%Al, the thin $_{C-X}MnO.SiO_{2}$ (x>1) oxide film was reduced by the Al. The $_{a-X}MnO.SiO_{2}$ (x<0.9) and $a-SiO_{2}$ oxides however remained embedded in the Zn coating close to the steel/coating interface. No $Fe_{2}Al_{5-X}Zn_{X}$ inhibition layer formation was observed. During hot dip galvanizing in Zn-0.20%Al, the $_{C-X}MnO.SiO_{2}$ (x>1) oxide film was also reduced and the amorphous $_{a-X}MnO.SiO_{2}$ and $a-SiO_{2}$ particles were embedded in the $Fe_{2}Al_{5-X}Zn_{X}$ inhibition layer formed at the steel/coating interface during hot dipping. The results clearly show that Al in the liquid Zn bath can reduce the crystalline $_{C-X}MnO.SiO_{2}$ (x>1) oxides but not the amorphous $_{a-X}MnO.SiO_{2}$ (x<0.9) and $a-SiO_{2}$ oxides. These oxides remain embedded in the Zn layer or in the inhibition layer, making it possible to apply a Zn or Zn-alloy coating on martensitic steel by hot dipping. The hot dipping process was also found to deteriorate the mechanical properties, independently of the Zn bath composition.

강화도 능내리출토 은제유물의 과학적 분석 및 재현실험을 통한 제작기법 연구 (A Study on the Manufacturing Technique by Scientific Analysis and Reproduction Experiment of Ancient Silver Objects Excavated from Neungnae-ri, Ganghwa Island)

  • 유동완;김수기
    • 보존과학회지
    • /
    • 제27권1호
    • /
    • pp.1-11
    • /
    • 2011
  • 강화도 능내리에서 출토된 고려시대 은제유물을 대상으로 성분조성과 경도, 조직특성을 연구하고 출토된 은제유물과 비슷한 성분비로 시편을 제작하여 가공방법과 온도에 따라 변하는 미세조직의 변화를 관찰하였다. 그 결과 능내리 출토 은제유물의 소지는 Cu가 2~6% 함유된 Ag-Cu 합금으로, Cu는 적절한 경도유지 등 특정 목정을 위하여 인위적으로 합금한 것으로 판단되며, 금으로 이루어진 도금층에서는 Hg가 약 11%의 함량으로 검출되어 아말감법으로 도금한 것으로 판단된다. 또한 일부 은제유물의 표면에서 확인되는 다공질 층은 실험시편 제작을 통한 확인결과 $400^{\circ}C$이상의 열이 가해질 때 생성되는 것으로, 능내리출토 은제유물들은 $400^{\circ}C$이상의 온도에서 열간가공하거나 열처리를 실시한 것으로 추정된다. 한편, 고부조로 타출된 은제유물 1점은 다른 은제유물과 비슷한 성분조성에도 불구하고 매우 낮은 경도를 보였는데, 이는 타출기법과 관계가 있는 것으로 추정된다.

정전압 분극곡선법에 의한 아말감의 부식 거동에 관한 연구 (A STUDY ON THE CORROSION BEHAVIOUR OF AMALGAMS BY USING OF POTENTIOSTATIC POLARIZATION METHOD)

  • 신동훈;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제12권1호
    • /
    • pp.39-49
    • /
    • 1986
  • The purpose of this study was to observe characteristic properties through the polarization curves and SEM images from 4 different types of amalgam obtained by using the potentiostats (Princeton EG & G) & SEM (Jeol/35), and to investigate the degree of corrosion on the oxidation peak of the each phase of amalgam. After each amalgam alloy and Hg was triturated as the direction of the manufacturer by means of the mechanical amalgamator (Shofu Co.), the triturated mass was inserted into the cylindrical metal mold which was 12mm in diameter and 10.0mm in height and was condensed by using routine manner. The specimen was removed from the mold and stored at room temperature for about 24 hours. The standard surface preparation was routinely carried out. Anodic polarization measurement was employed to confirm the corrosion behaviour of the amalgams in a 0.9% saline solution (P.H: 6.8-7.0) at $37^{\circ}C$. The initial rest potential (corrosion potential) was determined after 30 minutes of immersion of specimen in electrolyte, and the potential scan was begun at the point of 100mV cathodic from the corrosion potential. The scan rate was 0.17mV/sec. in the study to observe the degree of corrosion of each phase. SEI and EPMA images on the determined oxidation peaks of each amalgam were observed. The results were as follows: 1. In the four anodic polarization curves, low copper amalgams have three oxidation peaks and high copper amalgams have two oxidation peaks, -270mV, +26mV and +179mV(SEC) in the low copper lathe cut, and -300mV, +39mV and +163mV(SEC) in the low copper spherical. -4mV and +154mV(SEC) in the Dispersalloy, and +17mV and +180mV(SEC) in the Tytin as high copper amalgams. 2. ${\gamma}_2$ phase in the low copper amalgam and ${\eta}$ phase in the high copper amalgam were the most corrodible phases and Ag-Cu eutectic in high copper amalgam was the most slowly corroded phase. 3. Low copper amalgam was more susceptible in corrosion than high copper amalgam.

  • PDF

용탕단조법에 의한 AC8A/$Al_2O_3$ 복합재료의 기계적 성질에 관한 연구 (A Study on the Mechanical Properties of AC8A/$Al_2O_3$ Composites.)

  • 김기배;김경민;조순형;윤의박
    • 한국주조공학회지
    • /
    • 제11권6호
    • /
    • pp.475-481
    • /
    • 1991
  • In this study the fabrication technology and mechanical properties of AC8A/$Al_2O_3$ Composites by squeeze casting process were investigated to develope for application as the piston materials that require good friction, wear resistance, and thermal stability. AC8A/$Al_2O_3$ composistes without a porosity and the break of preform were fabricated at the melt temperature of $740^{\circ}C$, the preform temperature of $500^{\circ}C$, and mold temperature of $400^{\circ}C$ under the applied pressure of $1200kg/cm^2$ as the results of the observation of microstructures. As the results of this study, the tensile strength of AC8A/$Al_2O_3$ composites was not increased linearly with $Al_2O_3$ volume fraction and so it seemed not to agree with the rule of mixture, which had been used often in metal matrix composite. Also the tensile strength after thermal fatigue test was little different from that before the test. Consequently it was thought that AC8A/$Al_2O_3$ composites fabricated under our experimental conditions had a good thermal stability and subsequently a good interface bonding. Wear rate(i.e., volume loss per unit sliding distance) of AC8A/$Al_2O_3$ composites was decreased with $Al_2O_3$ volume fraction and the sliding speed at both room temperature and $250^{\circ}C$ and so there was a good correlation between wear rate and hardness. Also the wear rate of AC/8A20% $Al_2O_3$ composities was obtained the value of $1.65cm^3/cm$ at sliding speed of 1.14m/sec as compared with about $3.0\;{\times}10^{-8}cm^3/cm$ hyereutectie Al-Si alloy(Al-16%Si-2%Cu-1%Fe-1%Ni), which applied presently for piston materials. The wear behavior of $Al_2O_3$ composites was observed to a type of abrasive wear by the SEM view of wear surface.

  • PDF

A STRAIN GAUGE ANALYSIS OF IMPLANT-SUPPORTED CANTILEVERED FIXED PROSTHESIS UNDER DISTAL STATIC LOAD

  • Sohn, Byoung-Sup;Heo, Seong-Joo;Chang, Ik-Tae;Koak, Jai-Young;Kim, Seong-Kyun
    • 대한치과보철학회지
    • /
    • 제45권6호
    • /
    • pp.717-723
    • /
    • 2007
  • Statement of problem. Unreasonable distal cantilevered implant-supported prosthesis can mask functional problems of reconstruction temporarily, but it can cause serious strain and stress around its supported implant and surrounding alveolar bone. Purpose. The purpose of this study was to evaluate strain of implants supporting distal cantilevered fixed prosthesis with two different cantilevered length under distal cantilevered static load. Material and methods. A partially edentulous mandibular test model was fabricated with auto-polymerizing resin (POLYUROCK; Metalor technologies, Stuttgart, Swiss) and artificial denture teeth (Endura; Shofu inc., Kyoto, Japan). Two implants-supported 5-unit screw-retained cantilevered fixed prosthesis was made using standard methods with Type III gold alloy (Harmony C&B55; Ivoclar-vivadent, Liechtenstein, Germany) for superstructure and reinforced hard resin (Tescera; Ivoclar-vivadent, Liechtenstein, Germany) for occlusal material. Two strain gauges (KFG-1-120-C1-11L1M2R; KYOWA electronic instruments, Tokyo, Japan) were then attached to the mesial and the distal surface of each standard abutment with adhesive (M-bond 200; Tokuyama, Tokyo, Japan). Total four strain gauges were attached to test model and connected to dynamic signal conditioning strain amplifier (CTA1000; Curiotech inc., Paju, Korea). The stepped $20{\sim}100$ N in 25 N increments, cantilevered static load 8mm apart (Group I) or 16mm apart (Group II), were applied using digital push-pull gauge (Push-Pull Scale & Digital Force Gauge, Axis inc., Seoul, Korea). Each step was performed ten times and every strain signal was monitored and recorded. Results. In case of Group I, the strain values were surveyed by $80.7{\sim}353.8{\mu}m$ in Ch1, $7.5{\sim}47.9{\mu}m/m$ in Ch2, $45.7{\sim}278.6{\mu}m/m$ in Ch3 and $-212.2{\sim}718.7{\mu}m/m$ in Ch4 depending on increasing cantilevered static load. On the other hand, the strain values of Group II were surveyed by $149.9{\sim}612.8{\mu}m/m$ in Ch1, $26.0{\sim}168.5{\mu}m/m$ in Ch2, $114.3{\sim}632.3{\mu}m/m$ in Ch3, and $-323.2{\sim}-894.7{\mu}m/m$ in Ch4. Conclusion. A comparative statistical analysis using paired sample t-test about Group I Vs Group II under distal cantilevered load shows that there are statistical significant differences for all 4 channels (P<0.05).