• 제목/요약/키워드: All ceramic crown

검색결과 141건 처리시간 0.027초

알루미나 테이프를 사용한 유리 침투형 알루미나 코아의 변연적합도 (MARGINAL FIT OF GLASS INFILTRATED ALUMINA CORE FABRICATED FROM ALUMINA TAPES)

  • 오남식;이명현;김대준;이근우;이선형
    • 대한치과보철학회지
    • /
    • 제36권6호
    • /
    • pp.832-845
    • /
    • 1998
  • The purpose of this study was to compare the marginal fit of all ceramic crowns prepared from alumina slip casting, which is consistent with the conventional In-ceram system, and those fabricated from alumina tapes which is currently under development in an effort to alleviate complexities involved in the forming procedure of the In-ceram crown core. All ceramic crowns, made of In-ceram(slip casting) and alumina tapes(Doctor blade casting), were prepared with $90^{\circ}\;and\;135^{\circ}$ shoulder margins. The crowns were cemented with a glass ionomer cement and embeded in epoxy resin. The embedded crowns were sectioned faciolingually and mesiodistally and marginal discrepancies and marginal gaps were measured under the Measurescope MM II. The measurements were analyzed using Wilcoxon rank sum test and Kruskal-Wallis test and the results were as follows: 1. In the case of $90^{\circ}$ shoulder margin, the combined marginal discrepancies and marginal gaps were $78.3{\mu}m\;and\;44.4{\mu}m$ respectively, for the all ceramic crowns fabricated using the alumina tapes. In comparison, the values were $65{\mu}m\;and\;25.5{\mu}m$ for the In-ceram crowns. For the marginal gaps a statistical difference existed (p<0.05) but no significant difference was observed for the marginal discrepancy (p>0.05). 2. In the case of $135^{\circ}$ shoulder margin, the combined marginal discrepancy and marginal gaps were $82.1{\mu}m\;and\;40.2{\mu}m$ respectively, for the all ceramic crowns formed with the tapes. As compared with the marginal discrepancy and gaps of the $90^{\circ}$ shoulder margin in the fabricated from the alumina tapes, no significant statistical differencies were discerned in both cases (p>0.05). 3. There was no statistically significant difference in the fits among four locations around the margins of the all ceramic crowns fabricated using the alumina tapes. The results obtained in this study showed that the marginal fits of the glass infiltrated alumina cores fabricated from the alumina tapes are slightly higher value than those prepared using the In-ceram but the difference is within a clinically acceptable range.

  • PDF

CCD카메라를 이용한 수종 전부도재관의 변연적합도에 관한 연구 (A STUDY ON THE MARGINAL FIT OF ALL-CERAMIC CROWNS USING CCD CAMERA)

  • 문병화;양재호;이선형;정헌영
    • 대한치과보철학회지
    • /
    • 제36권2호
    • /
    • pp.273-292
    • /
    • 1998
  • The purpose of this study was to evaluate marginal fit of four all-ceramic crown systems 1) conventional In-Ceram, 2) copy-milled In-Ceram using Celay system, 3) IPS Empress, 4) OPC(Optimal Pressable Ceramic). All ceramic crowns were made on epoxy dies. The fabricated crowns were sandblasted, cleaned with ultrasonic cleansing, silanated, and cemented with Bistite composite resin cement. the selected marginal areas of the crowns were the labial, lingual, mesial, and distal surface. Each selected area of surface was $0.6{\times}1.6mm$ in dimension. The image of each marginal area was captured to computer files using DT-55 Frame Grabber and light microscope connected CCD camera. The marginal gaps were measured every $70{\mu}m$ using computer image analysis program. The results obtained were summarized as follows : 1. The marginal fit of four all-ceramic crowns were significantly different from each other(p<0.01), and mean marginal fit values obtained were $31.42{\pm}16.52{\mu}m$ in conventional In-Ceram, $55.45{\pm}27.90{\mu}m$ in copy-milled In-Ceram using Celay system, $44.36{\pm}24.59{\mu}m$ in IPS Empress, $47.21{\pm}20.42{\mu}m$ in OPC. 2. In the marginal fit of conventional In-Ceraw and copy-milled In-Ceram crowns using Celay system there was no significant difference between mesiodistal and buccolingual surface, but in the marginal fit of IPS Empress and OPC crowns, there was significant difference between mesiodistal and buccolingual surface(p<0.01). 3. The marginal fit of four kinds of all-ceramic crowns was clinically acceptable.

  • PDF

상악 제1소구치의 교두각에 따른 전부도재관의 응력분포에 관한 삼차원유한요소법적 연구 (A STUDY ON THE STRESS DISTRIBUTION OF THE ALL CERAMIC CROWNS ACCORDING TO THE CUSP ANGLE OF THE MAXILLARY FIRST PREMOLAR USING THREE DIMENSIONAL FINITE ELEMENT METHOD)

  • 김원규;신동국;송기범;동진근
    • 대한치과보철학회지
    • /
    • 제42권1호
    • /
    • pp.58-72
    • /
    • 2004
  • Statement of problem : Clinically, maxillary first premolar has a high risk of fracture. This is thought to be caused by the susceptible figure which the maxillary first premolar has In other words, sharp cusp angles of the premolar is thought to influence this situation. Purpose : This study was to know stress distribution of all-ceramic crown according to the cusp angle. Material and Method : It was manufactured a three dimensional finite element model simplified maxillary first premolar, and then analyzed stress distribution when cusp angle was each $80^{\circ}$, $90^{\circ}$, $100^{\circ}$, $110^{\circ}$ and $120^{\circ}$. Results and conclusion : 1. The von Misses stress showed that stress decreases as cusp angle increases in the central groove of the occlusal surface. 2. It showed that maximum principal stress was centered at the region of the central groove of the occlusal surface and a region which the force was inflicted. And also it appeared high on the lingual and buccal side of finish line. 3. The X axis of normal stress was focused in the central groove of the occlusal surface. The Y axis normal stress appeared high in the central groove of the occlusal surface, buccal and lingual side. 4. The Stress near the finish line showed a low value compared with stress in the region of the central groove of the occlusal surface. 5. It shows that the most dangerous angle for tooth fracture was on $80^{\circ}$ of the cusp angle and low on $120^{\circ}$ of its.

Metal bracket과 ceramic bracket의 전단 결합 강도와 debonding 상태에 관한 연구 (A STUDY OF THE SHEAR BOND STRENGTH OF METAL BRACKETS AND CERAMIC BRACKETS AND THE CONDITION AFTER DEBONDING)

  • 윤정진;유영규
    • 대한치과교정학회지
    • /
    • 제22권2호
    • /
    • pp.327-343
    • /
    • 1992
  • Metal brackets and ceramic brackets were bonded to natural teeth, porcelain crowns and gold crowns After stored in artificial saliva solution for 72 hours at $37^{\circ}C$, the shear bond strengths were measured by Instron and compared with them, the bonding sites and bracket bases were examined by scanning electron microscope and light optical stereomicroscope. The results were as follows: 1. The shear bond strengths of the group which metal brackets were bonded to natural teeth and the groups which ceramic brackets were bonded to natural teeth and porcelain crowns were comparable to each other, the shear bond strength of the group which metal brackets were bonded to gold crowns was significantly low. 2. The bond failed predominantly at the bracket base/adhesive interface with the bulk of adhesive remaining on enamel in the group which metal brackets were bonded to natural teeth. 3. The bond failed consistently at the crown/adhesive interface with all of adhesive remaining on the bracket babes in the group which metal brackets were bonded to gold crowns. 4. The bond failed at the enamel or crown/adhesive interface with the bulk of adhesive remaining on the bracket bases in the groups which cramic brackets were bonded to natural teeth and porcelain crowns. 5. The shear bond strengths of the groups which ceramic brackets were bonded to porcelain crowns were not affected by etching time.

  • PDF

In vitro performance and fracture resistance of novel CAD/CAM ceramic molar crowns loaded on implants and human teeth

  • Preis, Verena;Hahnel, Sebastian;Behr, Michael;Rosentritt, Martin
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권4호
    • /
    • pp.300-307
    • /
    • 2018
  • PURPOSE. To investigate the fatigue and fracture resistance of computer-aided design and computer-aided manufacturing (CAD/CAM) ceramic molar crowns on dental implants and human teeth. MATERIALS AND METHODS. Molar crowns (n=48; n=8/group) were fabricated of a lithium-disilicate-strengthened lithium aluminosilicate glass ceramic (N). Surfaces were polished (P) or glazed (G). Crowns were tested on human teeth (T) and implant-abutment analogues (I) simulating a chairside (C, crown bonded to abutment) or labside (L, screw channel) procedure for implant groups. Polished/glazed lithium disilicate (E) crowns (n=16) served as reference. Combined thermal cycling and mechanical loading (TC: $3000{\times}5^{\circ}C/3000{\times}55^{\circ}C$; ML: $1.2{\time}10^6$ cycles, 50 N) with antagonistic human molars (groups T) and steatite spheres (groups I) was performed under a chewing simulator. TCML crowns were then analyzed for failures (optical microscopy, SEM) and fracture force was determined. Data were statistically analyzed (Kolmogorow-Smirnov, one-way-ANOVA, post-hoc Bonferroni, ${\alpha}=.05$). RESULTS. All crowns survived TCML and showed small traces of wear. In human teeth groups, fracture forces of N crowns varied between $1214{\pm}293N$ (NPT) and $1324{\pm}498N$ (NGT), differing significantly ($P{\leq}.003$) from the polished reference EPT ($2044{\pm}302N$). Fracture forces in implant groups varied between $934{\pm}154N$ (NGI_L) and $1782{\pm}153N$ (NPI_C), providing higher values for the respective chairside crowns. Differences between polishing and glazing were not significant ($P{\geq}.066$) between crowns of identical materials and abutment support. CONCLUSION. Fracture resistance was influenced by the ceramic material, and partly by the tooth or implant situation and the clinical procedure (chairside/labside). Type of surface finish (polishing/glazing) had no significant influence. Clinical survival of the new glass ceramic may be comparable to lithium disilicate.

출력 지지대 두께가 선택적 레이저 용융법으로 제작된 금속 하부구 조물 적합도에 미치는 영향 (Effect of support thickness on the adaptation of Co-Cr alloy copings fabricated using selective laser melting)

  • 김재홍;김세연
    • 대한치과기공학회지
    • /
    • 제45권3호
    • /
    • pp.67-73
    • /
    • 2023
  • Purpose: This in vitro study aimed to evaluate the clinical acceptability of precision of fit of the support thickness of Co-Cr alloy copings fabricated using selective laser melting (SLM). Methods: Thirty dental stone models of maxillary left molar abutments were manufactured, images were taken using a scanner, and a computer-aided design program was used to design the form of a conventional metal ceramic crown coping. Overall, 30 single copings were made from Co-Cr alloy using SLM and divided into three support radius groups (0.1, 0.25, and 0.35 mm) of 10 for each. Digitized data were superimposed with three-dimensional inspection software to quantitatively obtain the machinability of a ceramic crown coping, and visual differences were confirmed using a color map. The root mean square values of the ceramic crown coping group were statistically analyzed using one-way analysis of variance (α=0.05). Results: The precision of fit was superior with 0.25 mm compared with 0.1 mm and 0.35 mm, and the results exhibited significant differences (p<0.05). All specimens showed that various support thicknesses did not exceed the clinically permitted value of 120 ㎛, which mean that more than 0.1 mm and 0.35 mm of support radius for SLM was adequate. Conclusion: The support thickness of Co-Cr alloy restoration fabricated using SLM is shown to affect the adaptation.

COMPARATIVE STUDY ON THE FRACTURE STRENGTH OF EMPRESS 2 CERAMIC AND TARGIS-VECTRIS CROWN

  • Cha Young-Joo;Yang Jae-Ho;Lee Sun-Hyung;Han Jung-Suk
    • 대한치과보철학회지
    • /
    • 제39권6호
    • /
    • pp.599-610
    • /
    • 2001
  • Due to an increasing interest in esthetics and concerns about toxic and allergic reactions to certain alloys, patients and dentists have been looking for metal-free tooth-colored restorations. Recent improvement in technology of new all-ceramic materials and composite materials has broadened the options for esthetic single crown restorations. The aim of this investigation was to study the fracture strength of the metal-free posterior single crowns fabricated using two recently introduced systems, Empress 2 ceramic and Targis-Vectris. Forty premolar-shaped stainless steel dies with the 1mm-wide circumferential shoulder were prepared. Ten cylindrical crowns having a diameter of 8.0mm and total height of 7.5mm were fabricated for each crown system respectively(PFM, Empress staining technique, Empress 2 layering technique, and Targis- Vectris). The crowns were filled with cement and placed on the stainless steel dies with firm finger pressure. The crowns were then stored in distilled water at room temperature for 24 hours before testing. The crowns were tested for fracture strength in an Instron universal testing machine (Instron 6022). With a crosshead speed of 1mm/min the center of the occlusal surface of the crown was loaded using a 4-mm-diameter stainless steel ball until fracture occurred. The fracture surfaces of the crowns were gold coated and examined using scanning electron microscopy(Jeol JSM-840 Joel Ltd., Akishima, Tokyo, Japan). Within the parameters of this study the following conclusions were drawn: 1. The mean fracture strength for PFM crowns was 5829(${\pm}906$)N; for Empress staining technique the fracture strength was 1697(${\pm}604$)N; for Empress 2 Layering technique the fracture strength was 1781N(${\pm}400$)N, and the fracture strength for Targis- Vectris was 3093(${\pm}475$)N. 2. The fracture strength of the PFM crowns was significantly higher than that of the Empress 2 and the Targis-Vectris crowns (P<0.05). 3. The fracture strength of the Targis-Vectris crowns was significantly higher than that of the Empress 2 crowns (P<0.05). 4. No statistical difference was found when Empress staining technique was compared with Empress 2 layering technique. 5. The SEM image of fracture surface of Empress 2 crown showed a very dense microstructure of the lithium disilicate crystals and the SEM image of fracture surface of Targis-Vectris crown showed indentations of Vectris and some fibers tom off from Vectris.

  • PDF

치과 CAD/CAM용 복합소재를 이용한 치과보철물의 제작에 대한 연구 (A Study on Hybrid material of Making Dental restorations by CAD/CAM System)

  • 최범진
    • 대한심미치과학회지
    • /
    • 제23권2호
    • /
    • pp.86-94
    • /
    • 2014
  • In recent years, perhaps the biggest driver in new material development is the desire to improve crown and bridge esthetics compared to the traditional PFM or all-metal restorations. As such, zirconia, leucite-containing glass ceramic and lithium disilicate glass ceramic have become prominent in the dental practice. Each material type performs differently regarding strength, toughness, ease of machining and the final preparation of the material prior to placement. For example, glass ceramic are typically weaker materials which limits its use to single-unit restorations. On the other hand, zirconia has a high fracture toughness which enables multi-unit restorations. This material requires a long sintering procedure which excludes its use for fast chair side production. Developed hybrid material of CAD/CAM is contained nano ceramic elements. This new material, called a Resin Nano Ceramic is unique in durability and function. The material is not a resin or composite. It is also not a pure ceramic. The material is a mixture of both and consists of ceramic. Like a composite, the material is not brittle and is fracture resistant. Like a glass ceramic, the material has excellent polish retention for lasting esthetics. The material is easily machined chair side or in a dental lab, polishes quickly to an esthetic finish and if necessary, can be useful restoratives.

외과적 정출술을 통한 치은 하방 치경부 파절선이 있는 상악 전치부의 심미 보철 치료 (Esthetic restoration of subgingival crown-root fractured maxillary anterior tooth using surgical extrusion)

  • 이소진;김유진;박영범;조규성;정문규
    • 대한치과보철학회지
    • /
    • 제50권3호
    • /
    • pp.204-209
    • /
    • 2012
  • 치은연 하방에 치아 우식증이나 치아 파절이 발생했을 때, 치아를 탈구시켜 즉시 정출시키는 외과적 정출술을 이용한 치관 연장술은 자연치를 보존하고 추가적인 치주적 수술 없이 단기간에 심미적인 보철 치료를 가능하게 한다. 본 환자는 16세 남환으로 본원 보존과로부터 상악 좌측 중절치의 심미 수복을 위해 본원 보철과로 의뢰되었다. 상악 좌측 중절치는 근관치료가 되어 있었으며 치관-치근 파절로 인해 협측 치관 길이는 4mm였으며 구개측 판막을 열었을 때 근심 구개측 치경부 파절 범위는 치은 하방 3-4mm에 위치하였다. 외과적 정출술을 통한 치관연장술을 시행하였으며 경과 관찰 및 임시 치아의 단계를 거쳐 3개월 후에 전부 도재관으로 수복하여 만족할 만한 임상결과를 얻을 수 있었다.

도재 소성 과정에서의 고온이 지르코니아 코어의 변연적합도에 미치는 영향 (Influence of High Temperature of the Porcelain Firing Process on the Marginal Fit of Zirconia Core)

  • 김재홍;김기백
    • 치위생과학회지
    • /
    • 제13권2호
    • /
    • pp.135-141
    • /
    • 2013
  • 본 연구는 치과에서 사용되는 심미 보철물 중에 하나인 지르코니아 기반의 전부도재관 제작 시 지르코니아 코어 위에 상부 도재를 축성하고 소성하는 과정에서 발생되는 고온이 완성된 전부도재관의 변연적합도에 미치는 영향을 분석함으로써 임상적 허용이 가능한지 알아볼 뿐 아니라, 치과보철치료를 위한 치과의사, 치과위생사, 치과기공사의 보철물 선택 시 임상적 참고자료로 제공할 목적으로 수행되었다. 심미에 가장 많은 영향을 미치는 상악 중절치를 지대치로 선정하여 동일한 모형 10개 제작 후 각각의 지대치에 적합한 지르코니아 코어를 제작하였다. 제작된 코어의 변연적합도 측정 후 코어 위에 상부 도재를 축성하여 전부도재관을 완성한 뒤 2차 측정을 실시하였으며, 측정 후 비교 분석 된 결과는 다음과 같다. 변연적합도는 지르코니아 코어 제작한 후 전부도재관으로 제작되는 과정에 따라 더 커졌으며, 통계적으로도 유의한 차이를 보였다(p<0.001). 그러나 전부도재관에서 총 80회 측정된 변연적합도의 값에서 임상적 허용 수치인 $120{\mu}m$을 넘지 않는 결과를 보였으며, 이와 같은 결과를 토대로 지르코니아 코어 위에 상부 도재 소성 시 변연적합도가 커지긴하나 임상적으로 허용이 가능하다는 결론을 도출하였다.