• 제목/요약/키워드: Alignment mechanism

검색결과 153건 처리시간 0.028초

Solid-Electrolyte Interphase in the Spinel Cathode Exposed to Carbonate Electrolyte in Li-Ion Battery Application: An ab-initio Study

  • 최대현;강준희;한병찬
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2017년도 춘계학술대회 논문집
    • /
    • pp.169-169
    • /
    • 2017
  • Due to key roles for the electrochemical stability and charge capacity the solid-electrolyte interphase (SEI) has been extensively studied in anodes of a Li-ion battery cell. There is, however, few of investigation for cathodes. Using first-principles based calculations we describe atomic-level process of the SEI layer formation at the interface of a carbonate electrolyte and $LiMn_2O_4$ spinel cathode. Furthermore, using beyond the conventional density functional theory (DFT+U) calculations we examine the work function of the cathode and frontier orbitals of the electrolyte. Based on the results we propose that proton transfer at the interface is an essential mechanism initiating the SEI layer formation in the $LiMn_2O_4$. Our results can guide a design concept for stable and high capacity Li-ion battery cell through screening an optimum electrolyte fine-tuned energy band alignment for a given cathode.

  • PDF

리스프랑 관절 손상 (Lisfranc Joint Injury)

  • 이명진
    • 대한족부족관절학회지
    • /
    • 제20권3호
    • /
    • pp.106-111
    • /
    • 2016
  • The Lisfranc joint complex is an anatomical association of many bones and articulation, restrained by an even more complex network of ligaments, capsules, and fascia, which must work in concert to provide normal and painless motion. Careful diagnostic workup with high-quality radiographs and computed tomography of the foot are used to diagnose injuries and fractures of this complex. We have to understand the normal anatomy and injury mechanism in order to appropriately treat Lisfranc injuries. Good results have been associated with anatomic reductions of all bones, which was achieved with restoration of proper alignment.

A Study on Fracture Behavior and Impact Stability of Sintered Rare-earth Permanent Magnets

  • Li, Wei;Li, Anhua;Wang, Huijie;Dong, Shengzhi;Guo, Yongquan
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part2
    • /
    • pp.790-791
    • /
    • 2006
  • The fracture behavior and mechanical characteristics of sintered rare-earth magnets were investigated. It shows that the fracture behavior and bending strength of the magnets obviously exhibit anisotropy. Sm-Co magnets tend to cleavage fracture in the close-packed (0001) plane or in the ($10\bar{1}1$) plane. The fracture mechanism of $Nd_2Fe_{14}B$ magnet mainly appears to be intergranular fracture. The anisotropy of fracture behavior and mechanical strength of sintered rare-earth magnets is caused mainly by the strong crystal-structure anisotropy and the grain alignment texture. The effects of Nd content, and Pr, Dy substitution on the impact stability of $Nd_2Fe_{14}B$ magnets were also reported.

  • PDF

Growth of Vertically Aligned CNTs with Ultra Thin Ni Catalysts

  • Ryu, Je-Hwang;Yu, Yi-Yin;Lee, Chang-Seok;Jang, Jin;Park, Kyu-Chang;Kim, Ki-Seo
    • Transactions on Electrical and Electronic Materials
    • /
    • 제9권2호
    • /
    • pp.62-66
    • /
    • 2008
  • We report on the growth mechanism of vertically aligned carbon nanotubes (VACNTs) using ultra thin Ni catalysts and direct current plasma enhanced chemical vapor deposition (PECVD) system. The CNTs were grown with -600 V bias to substrate electrode and catalyst thickness variation of 0.07 nm to 3 nm. The CNT density was reduced with catalyst thickness reduction and increased growth time. Cone like CNTs were grown with ultra thin Ni thickness, and it results from an etch of carbon network by reactive etchant species and continuous carbon precipitation on CNT walls. Vertically aligned sparse CNTs can be grown with ultra thin Ni catalyst.

Automated Wireless Recharging for Small UAVs

  • Jung, Sunghun;Ariyur, Kartik B.
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제18권3호
    • /
    • pp.588-600
    • /
    • 2017
  • We develop a wireless, contact free power transfer mechanism that is safer than the direct metallic contact and robust to imperfect alignment on landing at the base station. A magnetic field is created using inductors on both the transmitting and receiving sides. We use the inductive wireless recharging to increase autonomy and decrease the sensor interference by reducing the inductor loop size. By locating four independent small receiver loops and corresponding four circuits around the quadrotor UAV, we can increase safety from circuit malfunctions in comparison to the use of just one loop. On the base station, four folding robotic bars are used to realign the receiver loops over the transmitter loops. After adequate recharging as measured by battery voltages or power consumption at the bae station, the UAV sends a signal to the base station to open the robotic bars and takes off once freed from the robotic bars.

공작기계용 접촉식 측정 프로브의 프로빙 오차 보상에 관한 연구 (Touch-Trigger Probe Error Compensation in a Machining Center)

  • 이찬호;이응석
    • 대한기계학회논문집A
    • /
    • 제35권6호
    • /
    • pp.661-667
    • /
    • 2011
  • 접촉식 측정 프로브는 3 차원 좌표 측정기 및 CNC 공작기계 등에서 제품 검사에 많이 활용되고 있고, 최근 품질 향상을 위한 가공 및 검사장비의 고정도화에 따라 측정의 정확도도 또한 매우 중요시 되고 있다. 이에 따라 스트레인 게이지 등을 이용한 고정도의 측정 프로브가 사용되고 있기는 하지만, 본 연구에서는 경제적인 측면을 고려하여 산업현장에서 공작기계에 많이 활용되는 일반 접촉식 측정 프로브의 메커니즘을 이해하고, 측정 시 발생할 수 있는 프로빙 오차에 대한 분석 및 보정을 통하여 그 활용성을 높이고자 하였다. 이를 위하여 스타일러스 반경 및 중심 정렬오차가 규명되었고, 3 차원 공간상의 측정 좌표에서 프로빙 오차에 대한 해석이 이루어졌다. 이러한 오차들을 보정하기 위한 알고리즘이 개발되었으며, 실제 CNC 공작기계 상에서 기준구 측정을 통한 검증이 이루어졌다.

IGRINS : Mirror Mounts Optomechanical Design

  • ;박찬;이성호;;이한신;오희영;정화경;육인수;;김강민;천무영
    • 천문학회보
    • /
    • 제36권2호
    • /
    • pp.155.1-155.1
    • /
    • 2011
  • The Korea Astronomy and Space Science Institute (KASI) and the Department of Astronomy at the University of Texas at Austin (UT) are developing a near infrared wide-band high resolution spectrograph, IGRINS (Immersion Grating Infrared Spectrograph). The white-pupil design of the instrument optics uses 7 cryogenic mirrors including 3 aspherical off-axis collimators and 4 flat fold mirrors. Two of the 3 collimators are H- and K-band pupil transfer mirrors and they are designed as compensators for the system alignment in each channel. Therefore, their mount design will be one of the most sensitive parts in the IGRINS optomechanical system. The other flat fold mirrors are designed within the limited area. Each of those includes the features of 3 axial hard points and 2 radial hard points with one spring plunger in order for the proper deflection of the mirror. The design work will include the computer-aided 3D modeling and finite element analysis (FEA) to optimize the structural stability and the thermal behavior of the mount models. The mount body will also include a tip-tilt and translation adjustment mechanism to be used as the alignment compensators.

  • PDF

외측 발목 염좌 병력에 따른 정적 하지 정렬 차이: 외측 발목 염좌의 예측인자로서 정적 하지 정렬 검사의 효용성과 한계점 (Differences in Static Lower Extremity Alignment according to the History of Lateral Ankle Sprain: Efficacy and Limitation of Static Lower Limb Alignment Measurement as a Predictor of Lateral Ankle Sprain)

  • Jeon, Hyung Gyu;Ha, Sunghe;Lee, Inje;Kang, Tae Kyu;Kim, Eun Sung;Lee, Sae Yong
    • 한국운동역학회지
    • /
    • 제31권1호
    • /
    • pp.1-15
    • /
    • 2021
  • Objective: The aim of this study was to investigate 1) the difference in static lower extremity alignment (SLEA) according to a history of lateral ankle sprain (LAS), 2) to identify SLEA factors affecting LAS, and 3) to present the cut-off value and 4) the usefulness and limitations of the SLEA measurement. Method: This case-control study recruited 88 men (age: 27.78±4.69 yrs) and 39 women (age: 24.62±4.20 yrs) subjects with and without LAS. SLEA measurement protocol included Q angle, tibiofemoral angle, genu recurvatum, rear foot (RF) angle, tibal varum and torsion, navicular drop, ankle dorsiflexion range of motion (DF ROM). Independent t-test, logistic regression and receiver operating characteristic (ROC) curve were used for statistical analysis. Results: Men with a history of LAS had significantly smaller Q angles both in standing and in supine position, while women with a history of LAS had significantly greater DF ROM in non-weight bearing (NWB; p < 0.05). Logistic regression model suggests tibial varum (OR = 0.779, p = 0.021) and WB DF ROM (OR = 1.067, p = 0.045) were associated with LAS in men. In case of women, there were no significant SLEA factors for LAS, however, ROC curve analysis revealed standing RF angle (AUC = 0.647, p = 0.028) and NWB DF ROM (AUC = 0.648, p = 0.026) could be affecting factors for LAS. Conclusion: There are differences in SLEA according to the history of LAS, furthermore, the identified items were different by sex. In case of men, tibial varum and WB DF ROM affect LAS occurrence. Standing RF angle and NWB DF ROM of women could be a predictor for LAS. However, since the sensitivity and specificity in most of the SLEA measurements are low, kinematic in dynamic tasks should be considered together for a more accurate evaluation of LAS risk.

노인 척추 변형 환자의 수술적 결정 (Surgical Decision for Elderly Spine Deformity Patient)

  • 김용찬;주형석;이근호
    • 대한정형외과학회지
    • /
    • 제54권1호
    • /
    • pp.1-8
    • /
    • 2019
  • 전 세계적으로 노인 인구는 급증하는 추세이며 노인 척추 변형 환자에 대한 변형 교정 수술도 점점 증가하고 있다. 그러나 노인 환자들을 대상으로 척추 변형 교정 수술 시 합병증을 줄이기 위해 고려해야 할 사항들, 그리고 수술 후 좋은 임상적인 결과를 예측하기 위한 객관적인 인자들에 대해 아직 많은 논의가 되지 않았다. 노인 척추 변형 환자에서 수술 전 고려해야 될 사항으로 Cumulative Illness Rating Scale for Geriatrics 및 Charlson Comorbidity Index scores 등의 지표를 이용하여 내과적 동반 질환을 확인해야 한다. 이들 지표는 술 후 합병증의 발생률과 연관이 있으며 수술 전 내과적인 질환을 조절하여 이 지표 수치를 낮춘 이후 수술을 시행할 경우 합병증을 줄일 수 있다. 두 번째, 수술 전 골밀도 검사를 시행하여 골다공증의 정도를 확인해야 한다. 심한 골다공증이 동반된 노인 척추 변형 환자의 경우 기기술과 관련된 합병증을 줄이기 위한 여러 가지 수술적인 기법들이 알려져 있으며 수술 전 골형성 유도제를 사용하여 골밀도를 교정하는 방법도 시도해볼 수 있다. 세 번째, 전 신체 시상학 정렬을 고려해야 한다. 노인 척추 변형 환자에서 고관절, 슬관절 등의 하지 관절의 퇴행성 변화와 변형을 동반하고 있는 경우가 흔하며 또한 척추의 변형이 보상작용으로 하지 관절의 변형을 일으키기도 한다. 최근 전 신체 시상학 정렬이 이전 사용되었던 척추나 골반에 국한된 지표보다 임상적인 상태를 더 잘 예측할 수 있는 것으로 보고되어 변형 교정 수술 시 전 신체 시상학 정렬을 고려하여야 하겠다. 결론으로 노인 척추 변형 환자에서 변형 교정 수술을 시행할 경우 내과적인 동반 질환, 골다공증의 정도를 확인하여 합병증을 줄이기 위해 수술 전 미리 교정하는 것이 필요하다. 또한 교정 수술 시 골반이나 척추에 국한된 지표에 비하여 임상적인 상태를 더 잘 예측할 수 있는 전 신체 시상학 정렬을 고려해야 한다.

Co-Ni 합금위에서 수직방향으로 정렬된 탄소나노튜브의 성장 (Growth of vertically aligned carbon nanotubes on Co-Ni alloy metal)

  • 이철진;김대운;이태재;박정훈;손권희;류승철;송홍기;최영철;이영희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1504-1507
    • /
    • 1999
  • We have grown vertically aligned carbon nanotubes in a large area of Co-Ni codeposited Si substrates by the thermal CVD using $C_2H_2$ gas. Since the discovery of carbon nanotubes, Synthesis of carbon nanotubes for mass production has been achieved by several methods such as laser vaporization arc discharge, and pyrolysis. In particular, growth of vertically aligned nanotubes is of technological importance for applications to FED. Recently, vertically aligned carbon nanotubes have been grown on glass by PECVD Aligned carbon nanotubes can be also grown on mesoporous silica and Fe patterned porous silicon using CVD. Despite such breakthroughs in the growth, the growth mechanism of the alignment are still far from being clearly understood. Furthermore, FED has not been clearly demonstrated yet at a practical level. Here, we demonstrate that carbon nanotubes can be vertically aligned on catalyzed Si substrate when the domain density reaches a certain value. We suggest that steric hindrance between nanotubes at an initial stage of the growth forces nanotubes to align vertically and then nanotubes are further grown by the cap growth mechanism.

  • PDF