• Title/Summary/Keyword: Alarm suppression

Search Result 15, Processing Time 0.031 seconds

Practical Alarm Suppression Rules and their Implementation for Nuclear Power Plants (원자력발전소의 출력감발모드를 위한 경보축약 규칙)

  • Hwang, In-Koo;Kim, Yang-Mo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.10
    • /
    • pp.1804-1810
    • /
    • 2011
  • It is necessary to adopt some logical techniques and methods of alarm processing for a large complex plant such as nuclear power plants in order to present the occurred alarm messages properly and concisely. Among such alarm processing techniques, the alarm suppressing function is a strong tool to avoid alarm flooding during the sudden transients of plant output power such as turbine trips, reactor trips and other incidents. Unless any suppression or representation technologies are used in an alarm message listing system, it cannot provide quick assistance to plant operators or supervisors during plant upsets because too many alarm messages are presented in an alarm list window. This paper presents the key suppression methods and analysis processes developed for implementing a suppressed alarm message listing function of an integrated alarm system called LogACTs which has been applied to a CANDU nuclear power plant. A simulation testing of the suppressing function conducted with the real plant alarm message list data has demonstrated an effective performance of the developed logics with the high suppression rate.

Analysis of Unwanted Fire Alarm Signal Pattern of Smoke / Temperature Detector in the IoT-Based Fire Detection System (IoT 기반 화재탐지시스템의 연기 및 온도감지기 비화재보 신호 패턴 분석)

  • Park, Seunghwan;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.2
    • /
    • pp.69-75
    • /
    • 2022
  • Fire-alarm systems are safety equipment that facilitate rapid evacuation and early suppression in case of fire. It is highly desirable that fire-alarm systems have low false-alarm rates and are thus reliable. Until now, researchers have attempted to improve detector performance by applying new technologies such as IoT. To this end, IoT-based fire-detection systems have been developed. However, due to scarcity of large-scale operational data, researchers have barely studied malfunctioning in fire-alarm systems or attempted to reduce false-alarm rates in these systems. In this study, we analyzed false-alarm rates of smoke/temperature detectors and unwanted fire-alarm signal patterns at K institution, where Korea's largest IoT-based fire-detection system operates. After analyzing the fire alarm occurrences at the institution for five years, we inferred that the IoT-based fire-detection system showed lower false-alarm rates compared to the automatic fire-detection equipment. We analyzed the detection pattern by dividing it into two parts: normal operation and unwanted fire alarms. When a specific signal pattern was filtered out, the false-alarm rate was reduced to 66.9% in the smoke detector and to 46.9% in the temperature detector.

Development of Acquisition and Analysis System of Radar Information for Small Inshore and Coastal Fishing Vessels - Suppression of Radar Clutter by CFAR - (연근해 소형 어선의 레이더 정보 수록 및 해석 시스템 개발 - CFAR에 의한 레이더 잡음 억제 -)

  • 이대재;김광식;신형일;변덕수
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.4
    • /
    • pp.347-357
    • /
    • 2003
  • This paper describes on the suppression of sea clutter on marine radar display using a cell-averaging CFAR(constant false alarm rate) technique, and on the analysis of radar echo signal data in relation to the estimation of ARPA functions and the detection of the shadow effect in clutter returns. The echo signal was measured using a X -band radar, that is located on the Pukyong National University, with a horizontal beamwidth of $$3.9^{\circ}$$, a vertical beamwidth of $20^{\circ}$, pulsewidth of $0.8 {\mu}s$ and a transmitted peak power of 4 ㎾ The suppression performance of sea clutter was investigated for the probability of false alarm between $l0-^0.25;and; 10^-1.0$. Also the performance of cell averaging CFAR was compared with that of ideal fixed threshold. The motion vectors and trajectory of ships was extracted and the shadow effect in clutter returns was analyzed. The results obtained are summarized as follows;1. The ARPA plotting results and motion vectors for acquired targets extracted by analyzing the echo signal data were displayed on the PC based radar system and the continuous trajectory of ships was tracked in real time. 2. To suppress the sea clutter under noisy environment, a cell averaging CFAR processor having total CFAR window of 47 samples(20+20 reference cells, 3+3 guard cells and the cell under test) was designed. On a particular data set acquired at Suyong Man, Busan, Korea, when the probability of false alarm applied to the designed cell averaging CFAR processor was 10$^{-0}$.75/ the suppression performance of radar clutter was significantly improved. The results obtained suggest that the designed cell averaging CFAR processor was very effective in uniform clutter environments. 3. It is concluded that the cell averaging CF AR may be able to give a considerable improvement in suppression performance of uniform sea clutter compared to the ideal fixed threshold. 4. The effective height of target, that was estimated by analyzing the shadow effect in clutter returns for a number of range bins behind the target as seen from the radar antenna, was approximately 1.2 m and the information for this height can be used to extract the shape parameter of tracked target..

A Study on Design and Operation Performance of Automatic Fire Detection Equipment (P-type One-class Receiver) by Bidirectional Communication (양방향 통신이 가능한 자동화재탐지설비(P형 1급 수신기)의 설계 및 동작특성에 관한 연구)

  • Lee, Bong-Seob;Kwak, Dong-Kurl;Jung, Do-Young;Cheon, Dong-Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.2
    • /
    • pp.347-353
    • /
    • 2012
  • In this paper, authors will develop the quick and precise remote controller of automatic fire detection equipment (P-type one-class receiver) based on information communication technology (IT). The remote controller detects the fire and disaster in the building automatically and quickly and then activates the facilities to extinguish the fire and disaster, monitoring such situation in a real time through wire-wireless communication network. The proposed remote controller is applied a programmable logic device (PLD) micom. of one-chip type which is small size and lightweight and also has highly sensitive-precise reliabilities. The one-chip type PLD micom. analyzes digital signals from sensors, then activates fire extinguishing facilities for alarm and rapid suppression in a case of fire and disaster. The detected data is also transferred to a remote situation room through wire-wireless network of RS232c and bluetooth communication, and then the situation room sends an emergency alarm signal. The automatic fire detection equipment (AFDE) based on IT will minimize the life and wealth loss while prevents fire and disaster.

An Open Circuit Fault Diagnostic Technique in IGBTs for AC to DC Converters Applied in Microgrid Applications

  • Khomfoi, Surin;Sae-Kok, Warachart;Ngamroo, Issarachai
    • Journal of Power Electronics
    • /
    • v.11 no.6
    • /
    • pp.801-810
    • /
    • 2011
  • An open circuit fault diagnostic method in IGBTs for the ac to dc converters used in microgrid applications is developed in this paper. An ac to dc converter is a key technology for microgrids in order to interface both distributed generation (DG) and renewable energy resources (RES). Also, highly reliable ac to dc converters are necessary to keep converters in continuous operation as long as possible during power switch fault conditions. Therefore, the proposed fault diagnostic method is developed to reduce the fault detection time and to avoid any other fault alarms because continuous operation is desired. The proposed diagnostic method is a combination of the absolute normalized dc current technique and the false alarm suppression algorithm to overcome the long fault detection time and fault alarm problems. The simulation and experimental results show that the developed fault diagnostic method can perform fault detection within about one cycle. The results illustrate that the reliability of an ac to dc converter interfaced with a microgrid can be improved by using the proposed fault diagnostic method.

Improvement of non-negative matrix factorization-based reverberation suppression for bistatic active sonar (양상태 능동 소나를 위한 비음수 행렬 분해 기반의 잔향 제거 기법의 성능 개선)

  • Lee, Seokjin;Lee, Yongon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.4
    • /
    • pp.468-479
    • /
    • 2022
  • To detect targets with active sonar system in the underwater environments, the targets are localized by receiving the echoes of the transmitted sounds reflected from the targets. In this case, reverberation from the scatterers is also generated, which prevents detection of the target echo. To detect the target effectively, reverberation suppression techniques such as pre-whitening based on autoregressive model and principal component inversion have been studied, and recently a Non-negative Matrix Factorization (NMF)-based technique has been also devised. The NMF-based reverberation suppression technique shows improved performance compared to the conventional methods, but the geometry of the transducer and receiver and attenuation by distance have not been considered. In this paper, the performance is improved through preprocessing such as the directionality of the receiver, Doppler related thereto, and attenuation for distance, in the case of using a continuous wave with a bistatic sonar. In order to evaluate the performance of the proposed system, simulation with a reverberation model was performed. The results show that the detection probability performance improved by 10 % to 40 % at a low false alarm probability of 1 % relative to the conventional non-negative matrix factorization.

Performance-based Fire Protection Design of Domestic Super High-rise Buildings - Evaluation by ASET and RSET -

  • Roh, Hyeong-Ki
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.2
    • /
    • pp.9-13
    • /
    • 2011
  • The Performance-based fire protection design required to construct super high-rise building is the active measure for the evaluation of fire risks and the establishment of fire protection systems on the basis of engineering analysis, which is more efficient and proper than existing prescriptive-based design. This study applied time-line analysis of RSET is required safe egress time and ASET is available safe egress time with the fire and evacuation simulation to analyze. The result of this study showed the sprinkler system increased ASET and fire detection and alarm system reduced RSET efficiently. Reduced evacuation time influences to secure the life safety. Also it is essential to maintain the fire suppression system and fire detection & alarm system properly. Database of fire movement and evacuation action program are useful for the performance-based design.

Clutter Suppression Method for Altitude and Mainlobe Clutter In Moving Platform Radar (이동 플랫폼 레이더에서 고도 클러터와 주엽 클러터 억제 기법)

  • Jeon, Hyeonmu;Bae, Chang-sik;Yang, Hoon-gee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.10
    • /
    • pp.1386-1391
    • /
    • 2018
  • The radar in the moving platform is interfered by the mainlobe clutter as well as the altitude clutter that is received from sidelobe. The altitude clutter is relatively short range compared to mainlobe clutter and therefore enters the radar with a strong signal. As these clutters are major reason making the probability of false alarm high, it is required to suppress both altitude clutter and mainlobe clutter. In this paper, It is proposed the clutter suppression method consisted of two pulse canceller to suppress the clutters being two frequency area in moving platform. It is analyzed the correlation of output signals according to the use of pulse canceller and provided the structure of staggered pulse canceller considered the correlation. Finally, it shows that altitude clutter and mainlobe clutter are suppressed by proposed staggered pulse canceller using the simulation.

A Study on the Performance Variation Depending on Using Period of Ionization Smoke Detector (이온화식연기감지기의 사용기간 경과에 따른 성능변화 연구)

  • Kim, Shi-Kuk;Baek, Won-Don;Ok, Kyung-Jea;Lee, Chun-Ha
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.175-179
    • /
    • 2008
  • This paper studied on the performance variation depending on using period of ionization smoke detector. In korea, there were a lot of loss of lives and property because of fire. In many cases, an alarm equipment didn't operate though it was set up, so it causes the failure of early evacuation and fire suppression. Accordingly, an experiment on the change of ionization smoke detector in capacity performed with ionization smoke detector which is set up with fire objects.

  • PDF

Adaptive CFAR implementation of UWB radar for collision avoidance in swarm drones of time-varying velocities (군집 비행 드론의 충돌 방지를 위한 UWB 레이다의 속도 감응형 CFAR 최적화 연구)

  • Lee, Sae-Mi;Moon, Min-Jeong;Chun, Hyung-Il;Lee, Woo-Kyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.3
    • /
    • pp.456-463
    • /
    • 2021
  • In this paper, Ultra Wide-Band(UWB) radar sensor is employed to detect flying drones and avoid collision in dense clutter environments. UWB signal is preferred when high resolution range measurement is required for moving targets. However, the time varying motion of flying drones may increase clutter noises in return signals and deteriorates the target detection performance, which lead to the performance degradation of anti-collision radars. We adopt a dynamic clutter suppression algorithm to estimate the time-varying distances to the moving drones with enhanced accuracy. A modified Constant False Alarm Rate(CFAR) is developed using an adaptive filter algorithm to suppress clutter while the false detection performance is well maintained. For this purpose, a velocity dependent CFAR algorithm is implemented to eliminate the clutter noise against dynamic target motions. Experiments are performed against flying drones having arbitrary trajectories to verify the performance improvement.