• 제목/요약/키워드: Alarm displays

검색결과 20건 처리시간 0.021초

Human Factors Evaluations of Alarm Displays in Main Control Rooms

  • Choe, Pilsung
    • 대한인간공학회지
    • /
    • 제32권1호
    • /
    • pp.69-75
    • /
    • 2013
  • Objective: This study proposes an alarm display and compares it with the one(alarm tile display) widely used in main control rooms(MCRs) of nuclear power plants. Background: Catching up with the rapid development of computer technologies, advanced MCRs has been required. Using modern technologies of computers and visual displays, we have a lot of potential to improve user performance and satisfaction as well as safety in MCRs. Method: The alarm bar display has been proposed to reduce some potential problems of the alarm tile display in this study. Human factors evaluations were conducted to compare both types of displays. Two interfaces of bar alarm and tile alarm were simulated on the desktop computer for the user-involved experiment. Eight students participated in the experiment with the within-subject design. Results: The alarm bar was slightly better in terms of situation awareness, and preferred to understand alarm dynamics. The alarm tile was slightly or significantly better in other measures. Conclusion: Both alarm displays have their own advantages and disadvantages. Therefore, combining benefits of both displays can be used to optimize the design of alarm displays. Application: The proposed display is expected to compensate the existing displays for certain purposes.

Comparison of alarm systems for advanced control room

  • Lee, H.C.;Oh, I.S.;Sim, B.S.;Koo, I.S.;Kim, J.T.;Lee, K.Y.;Park, J.K
    • 대한인간공학회:학술대회논문집
    • /
    • 대한인간공학회 1997년도 추계학술대회논문집
    • /
    • pp.303-309
    • /
    • 1997
  • This study is carried out to investigate performance differences between two alarm presentation methods from the viewpoint of human factors and to provide items to be improved. One of the alarm display methods considered in this study displays alarm lists on VDT combined with hardwired alarm panels. The other method displays alarms on plant mimic diagrams of VDT. This alarm display method has other features for operator aid with which operator can get detailed information on the activated alarm in the mimic diagrams, and the capability for alarm processing such as alarm reduction and prioritization. To compare the twodisplay methods, a human factor experiment was performed with a plant simulator in the ITF(Integrated Test Fcility) that plant operators run for 4 event scenarios. During the experiment, physiological measurements, system and operator action log, and audio/video recordings were collected. Operators' subjective opinion was collected as well after the experiment. Time, error rate and situation awareness were major human factor criteria used for the comparison during the analysis stage of the experiment. No statistical significance was found in the results of our statistical comparison analysis. Several findings were identified, however, through the analysis of subjective opinions.

  • PDF

제어실의 인적오류 예방에 적용 가능한 ISO 표준 검토 (A Review on ISO Standards Applicable for a Human Error Tolerant Control Center Design)

  • 이동하
    • 대한인간공학회지
    • /
    • 제30권1호
    • /
    • pp.161-168
    • /
    • 2011
  • Objective: The aim of this study is to review the ISO(the International Organization for Standardization) standards recommendations on a human error tolerant control room design. Background: ISO TC(Technical Committee) 159 published a variety of international standards on design of mental and physical work, design of displays and controls, and workstation layout design. A proper edition of these standards can be a good resource for a human error tolerant control center design guidelines. Method: Recommendations of ISO TC 159 standards were grouped into arrangement of control suite, layout of control room, layout and dimensions of workstations, design of displays and controls, environmental design, alarm, automation, management system design, procedure and training. Results: It was found that some standards on the design of supervisory control and data acquisition(SCADA), alarm, automation, layout, workload management, and environment can be used for human error prevention guidelines in the control center design. Conclusion: ISO TC 159 standards were not sufficient to cover all the ergonomics area of control center design. Application: Designers can have technical aids from these ISO standards to improve ergonomic performance of their control center.

원자력발전소용 경보원인추적시스템 설계 및 구현 (Design and Implementation of a Alarm-Cause Tracking System for Nuclear Power Plant)

  • 김정택;이정운;박재창;권기춘;류승필
    • 정보학연구
    • /
    • 제5권2호
    • /
    • pp.81-94
    • /
    • 2002
  • 원자력발전소에서 경보가 발생하면 운전원이 세부원인을 파악하고 그에 맞는 조치를 취해야한다. 세부원인을 파악하기 위해서는 운전원의 경험, 경보절차서, 경보논리도면 등을 참조하는데, 경보절차서에는 관련원인이 여러개 있을 수 있으므로 이런 경우에 논리도면을 참조하게 된다. 그러나 수백 페이지이상 되는 논리도면을 보면서 경보논리의 상태 및 원인을 추적하는 것은 매우 힘들다. 이 연구에서는 논리도면을 전산화하여 온라인으로 경보발생 시 해당경보의 상세원인을 추적하여 화면에 표시하는 시스템을 제안한다.

  • PDF

An Intelligent Human-Machine Interface for Next Generation Nuclear Power Plants

  • Park, Seong-Soo;Park, Jin-Kyun;Hong, Jin-Hyuk;Chang, Soon-Heung;Kim, Han-Gon
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1995년도 추계학술발표회논문집(1)
    • /
    • pp.191-196
    • /
    • 1995
  • The intelligent human-machine interface (HMI) has been developed to enhance the safety and availability of a nuclear power plant by improving operational reliability The key elements of the HMI are the large display panels which present synopsis of the plant status and the compact, digital work stations for the primary operator control and monitoring functions. The work station consists of four consoles such as a dynamic alarm console (DAC), a system information console (SIC), a computerized operating-procedure console (COC), and a safety related information console (SRIC). The DAC provides clean alarm pictures, in which information overlapping is excluded and alarm impacts are discriminated, for quick situation awareness. The SIC covers a normal operation by offering all necessary plant information and control functions. In addition, it is closely linked with the DAC and the COC to automatically display related system information under the request of these consoles. The COC aids the operator with proper emergency operation guidelines so as to shutdown the plant safely, and it also reduces his physical/mental burden by automating the operating procedures. The SRIC continuously displays safety related information to allow the operator to assess the plant status focusing on plant safety. The proposed HMI has been validated and demonstrated with on-line data obtained from the full-scope simulator for Yonggwang Units 1,2.

  • PDF

원자력 및 핵의학 분야용 Total RMS (Radiation Monitoring System)의 설계 (Design of Total RMS(Radiation Monitoring System) for nuclear and nuclear medicine)

  • 고태영;이주현;이승호
    • 전기전자학회논문지
    • /
    • 제21권2호
    • /
    • pp.158-161
    • /
    • 2017
  • 본 논문에서는 원자력 및 핵의학 분야용 Total RMS(Radiation Monitoring System)를 제안한다. 제안하는 시스템은 Stack Monitor, Area Monitor, Water(Liquid) Monitor 등을 하나의 시스템으로 확장 및 제어할 수 있는 장비로 각 방사선 검출기에서 측정된 신호를 통합 모니터링 할 수 있다. 제안하는 시스템은 해당 방사선을 검출하는 Sensor Module, 방사선 검출 위치에 인접한 곳에서 방사선량을 디스플레이 하는 Display Unit, 검출된 방사선량이 위험 수준에 도달시 경보를 알리는 Alarm Unit, 각 모니터링에서 측정된 방사선량들을 취합하고 저장하여 원격 감시 시스템에 내용을 전달하는 Main Hub, 원격지에서 측정된 방사선량 상태를 일목요연하게 디스플레이 하는 RMS Monitoring Unit 등으로 구성된다. 제안된 원자력 및 핵의학 분야용 Total RMS의 성능을 평가하기 위하여 공인시험기관에서 실험한 결과, 측정 불확도가 8.5%이하로 측정되어 국제 표준인 ${\pm}15%$ 이하에서 정상동작 됨이 확인되었다.

환경잡음신호의 주파수특성 분석에 의한 전자보안펜스의 신뢰성 향상 (Reliability Improvement of the Electronic Security Fence Using Friction Electricity Sensor by Analyzing Frequency Characteristic of Environmental Noise Signal)

  • 윤석진;원서연;김희식;이용철;장우영
    • 전자공학회논문지
    • /
    • 제52권3호
    • /
    • pp.173-180
    • /
    • 2015
  • 외곽 침입 탐지를 위한 전자보안 펜스 시스템은 광망, 장력, 자력 등 다양한 시스템이 개발되어 국가 보안시설에 설치되고 있으나, 실외에 설치가 되는 시스템으로 환경 잡음에 따른 오경보의 발생에 따라 현장적용에 불편함이 크다. 본 논문에서 연구하는 마찰대전 방식의 전자보안펜스 시스템은 침입에 따른 감지 성능뿐 아니라, 경제성, 시공편리성, 유지보수 측면에서 많은 장점을 가지고 있으나, 환경 잡음에 따른 신뢰성 개선이 필요하다. 본 연구의 목적은 환경 잡음에 따른 오경보 감소에 대한 연구를 하는 것이다. 기존의 마찰대전 방식 전자보안펜스 시스템은 펜스 침입 신호의 크기를 분석하여 침입 경보를 결정했으나 강풍과 같은 환경잡음에 의해서도, 동일한 신호의 크기가 발생되어 오경보의 해석에 어려움이 있었다. 오경보 감소방안 연구를 위해 서울시립대학교 교내의 온실 실험실 Fence 위에 시스템을 설치하였고, 환경잡음 신호와의 관계를 분석하기 위해 온도, 풍속, 습도 등에 대한 데이터를 별도로 수집하였다. 수집된 신호는 고속푸리에 변환 FFT(Fast Fourier Transform)를 이용해 주파수 특성을 분석하여, 침입신호와 환경잡음신호를 구분하는 알고리즘으로 개선하였다. 제안된 신호침입 알고리즘의 적용 전 후 데이터를 수집, 분석한 결과, 알고리즘 적용 후, 약 98%의 개선이 있음을 확인하였다. 실제 주요보안 시설에 설치할 경우 주변 잡음신호에 대해 신뢰성을 향상할 수 있는 알고리즘인 것을 확인하였다.

화재전류(IGR) 경보 기능이 내장된 누전경보차단기의 개발 및 안전성 평가에 관한 연구 (Development and Safety Evaluation of Earth Leakage Alarm Breaker Equipped with Fire Current (IGR) Alarming Function)

  • 고완수;최충석
    • 한국화재소방학회논문지
    • /
    • 제34권3호
    • /
    • pp.43-48
    • /
    • 2020
  • 본 연구에서는 누전경보 기능이 내장된 누전경보차단기(JER-E2S, ETECKOREA Co., Korea)를 개발하고, 그 특성을 분석하였다. 개발된 누전경보차단기는 단상 220 V 전용으로 정격전류는 32 A, 20 A, 20 A(화장실용), 16 A 등이다. JER-E2S는 기존 누전차단기(ELB)의 특성을 모두 만족하고 있으며, 13 ± 2 mA의 저항성누설전류(Igr)인 화재전류가 전선로에 흐르면 실시간 검출하여 LED 램프로 위험 상태를 점멸할 수 있는 제품이다. 개발된 누전경보차단기는 LED 램프 및 통신기기 등에서 필연적으로 발생되는 용량성누설전류(Igc)에 대한 내성이 있어서 안정적인 전기 공급이 가능하다. 또한, 누전경보차단기는 순간지락 정전보호 기능이 있어서 작은 물방울 및 나뭇잎 등의 순간지락에 따른 차단기의 오동작 없이 전원 공급이 가능하다. 그리고 개발된 누전경보차단기의 대기전력은 0.1 W 이하로 기존 ELB에 비해 절전 성능이 3~8배 우수한 특성을 나타냈으며, 일반 120 ㎡의 아파트 1 세대에 10개 정도의 누전경보차단기가 설치되었을 때 1 개월에 2~5 kWh의 전기를 절감할 수 있다. 개발된 누전경보차단기는 기존 누전차단기의 특성을 만족할 뿐만 아니라 전기화재 예방기능 및 오동작 방지기능이 있어서 전원 품질이 우수하고, 전기화재 예방에 혁신적으로 기여할 수 있는 제품이다.

마이크로 프로세서를 이용한 미숙아 보육기 시스템 (Development of the Infant Incubator Using Micro Processor)

  • 차동익;이성용;김종만;서규영;박민용
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 추계학술대회
    • /
    • pp.83-85
    • /
    • 1992
  • In this paper, the Infant Incubator Consisting of amp lifer, A/D Convert, I/O Expand, Watchdog Timer, Alarm Circuit. Display, and mirco-Computer part was developed. The care of Premature new borns of the required that they be in an environment in which temperature is elevaled and Controlled, because they are unable to regulated their own temperature. The central and processing methods based on micro-processor employ the flexibility, and economy over other conventional system. The system characteristic were as follows 1) system based on micro-processor. 2) Easy-to read, touch-Operate control panel all displays and indicators 3) System flexibility.

  • PDF

감성평가를 이용한 선교알람관리시스템의 청각아이콘 평가 (Selection of Auditory Icons in Ship Bridge Alarm Management System Using the Sensibility Evaluation)

  • 오승빈;장준혁;박진형;김홍태
    • 한국항해항만학회지
    • /
    • 제37권4호
    • /
    • pp.401-407
    • /
    • 2013
  • 선박 기술 발전에 따라 다양한 장비가 개발되고 있지만 인적요인에 의한 해양사고는 여전히 지속적으로 발생하고 있다. 이러한 상황에서 인적요인에 의한 사고 감소를 위하여 선교 내 항해장비의 인간공학적 설계가 많은 관심의 대상이 되고 있다. 선교에는 항해 및 통신장비로부터 나오는 음향 신호 등 항해사에게 정보를 전달하기 위한 다양한 청각 신호들이 존재한다. 하지만 이러한 청각 신호, 청각 경고음에 대한 인간의 인지능력에 관한 연구는 미흡한 실정이다. 청각 경고음은 크게 음성(speech), 함축적 소리(abstract sound), 청각 아이콘(auditory icon)으로 구분 할 수 있다. 본 연구에서는 청각 경고음 중 청각아이콘을 활용하여 5가지의 경보상황(엔진, 화재, 조타, 전기, 충돌)에서 청각아이콘에 대한 감성평가를 통해 각 상황에 적합한 청각아이콘을 선별하였다. 5가지 경보상황 중 뚜렷한 경향이 나타난 2가지 경보상황(엔진, 충돌)에 대하여 분석을 하였다. 본 연구 결과는 선교 내 청각표시장치와 통합선교알람관리시스템을 위한 기초자료로 활용될 수 있을 것으로 기대된다.