• Title/Summary/Keyword: Al tube

Search Result 343, Processing Time 0.029 seconds

Correlation among Ownership of Home Appliances Using Multivariate Probit Model (다변량 프로빗 모형을 이용한 가전제품 구매의 상관관계 분석)

  • Kim, Chang-Seob;Shin, Jung-Woo;Lee, Mi-Suk;Lee, Jong-Su
    • Journal of Global Scholars of Marketing Science
    • /
    • v.19 no.2
    • /
    • pp.17-26
    • /
    • 2009
  • As the lifestyle of consumers changes and the need for various products increases, new products are being developed in the market. Each household owns various home appliances which are purchased through the choice of a decision maker. These appliances include not only large-sized products such as TV, refrigerator, and washing machine, but also small-sized products such as microwave oven and air cleaner. There exists latent correlation among possession of home appliances, even though they are purchased independently. The purpose of this research is to analyze the effect of demographic factors on the purchase and possession of each home appliances, and to derive some relationships among various appliances. To achieve this purpose, the present status on the possession of each home appliances are investigated through consumer survey data on the electric and energy product. And a multivariate probit(MVP) model is applied for the empirical analysis. From the estimation results, some appliances show a substitutive or complementary pattern as expected, while others which look apparently unrelated have correlation by co-incidence. This research has several advantages compared to previous literatures on home appliances. First, this research focuses on the various products which are purchased by each household, while previous researches such as Matsukawa and Ito(1998) and Yoon(2007) focus just on a particular product. Second, the methodology of this research can consider a choice process of each product and correlation among products simultaneously. Lastly, this research can analyze not only a substitutive or complementary relationship in the same category, but also the correlation among products in the different categories. As the data on the possession of home appliances in each household has a characteristic of multiple choice, not a single choice, a MVP model are used for the empirical analysis. A MVP model is derived from a random utility model, and has an advantage compared to a multinomial logit model in that correlation among error terms can be derive(Manchanda et al., 1999; Edwards and Allenby, 2003). It is assumed that the error term has a normal distribution with zero mean and variance-covariance matrix ${\Omega}$. Hence, the sign and value of correlation coefficients means the relationship between two alternatives(Manchanda et al., 1999). This research uses the data of 'TEMEP Household ICT/Energy Survey (THIES) 2008' which is conducted by Technology Management, Economics and Policy Program in Seoul National University. The empirical analysis of this research is accomplished in two steps. First, a MVP model with demographic variables is estimated to analyze the effect of the characteristics of household on the purchase of each home appliances. In this research, some variables such as education level, region, size of family, average income, type of house are considered. Second, a MVP model excluding demographic variables is estimated to analyze the correlation among each home appliances. According to the estimation results of variance-covariance matrix, each households tend to own some appliances such as washing machine-refrigerator-cleaner-microwave oven, and air conditioner-dish washer-washing machine and so on. On the other hand, several products such as analog braun tube TV-digital braun tube TV and desktop PC-portable PC show a substitutive pattern. Lastly, the correlation map of home appliances are derived using multi-dimensional scaling(MDS) method based on the result of variance-covariance matrix. This research can provide significant implications for the firm's marketing strategies such as bundling, pricing, display and so on. In addition, this research can provide significant information for the development of convergence products and related technologies. A convergence product can decrease its market uncertainty, if two products which consumers tend to purchase together are integrated into it. The results of this research are more meaningful because it is based on the possession status of each household through the survey data.

  • PDF

Studies on the Simplified Hemagglutination Reaction to Pasteurella multocida and the Stabilization of Erythrocytes (Pasteurella multocida에 대(對)한 간이적혈구(簡易赤血球) 응집반응(凝集反應)과 적혈구(赤血球)의 안정화(安定化)에 관(關)한 연구(硏究))

  • Lee, Hak Cheul;Chung, Yung Gun;Kim, Kyo-Joon
    • Korean Journal of Veterinary Research
    • /
    • v.10 no.1
    • /
    • pp.11-23
    • /
    • 1970
  • Recently Carter(1952) reported the capsule antigens of Pasteurella multocida could be divided into four serological types A,B,C and D by means of precipitation tests. Subsequently he showed that the most sensitive for identification of these types involved the use of capsule substance adsorbed by erythrocytes in hemagglutination test. It may be somewhat difficult to conduct the hemagglutination test in small laboratory, because relatively large amounts of antisera and erythrocytes of the human O type are required for the test. A simple method for serological typing of P. multocida was the slide agglutination test employed by Little et al. (1943) and Namioka et al. (1962), but this method is still in controversy. The author tried adapting Carter's hemagglutination method to the slide method so called "micromethod technique", and studied on the stabilization of erythrocytes for use of slide hemagglutination to P. multocida although many invesigators reported the stabilization of erythrocytes. The results obtained are summarized as follows: 1. A simplified method (slide method) for capsule typing of the organism was developed by adapting Carter's hemagglutination reaction(tube method). Antibody-containing serum can be diluted serially on Boerner's microtest slide with capillary or serological pipetts with a considerable accuracy. The slide reaction can be carried out with case on the slide by adding $0.05m{\ell}$ of antigen-sensitized erythrocytes suspension diluted to one percent on $0.05m{\ell}$ of serially diluted antibody-containing sera, and the final result can be read after 60 minutes at the room temperature ($15^{\circ}C$). 2. It is difficult to determine superiority of inferiority between the slide method and the tube method on the pattern of the reaction of hemagglutination. 3. The pH range of 6.6 to 8.3 is optimal for the slide hemagglutination reaction. 4. The antigen-sensitization against erythrocytes at $37^{\circ}C$ is optimal for the slide hemagglutination. 5. Both the doses and concentration of antigen do not influence the antigen-adsorbing capacity of erythrocytes. 6. The reduction of antigen-sensitizing hours does not influence the antigen-adsorbing capacity of erythrocytes even 30 minutes. 7. The tannic acid treatment against formalinized and non-formalinized erythrocytes showed no effect on the reaction of hemagglutination. 8. The erythrocytes preserved at $4^{\circ}C$ in the ACD solution do not decrease the reactivity on the reaction of hemagglutination for 60 days, while they begin slight hemolysis 30 days after preserving. 9. The stable preparation of erythrocytes can be obtained by treating the cells at $37^{\circ}C$ for 20 hours with from 4 to 8 percent of formalin in saline or buffer. These cells can be preserved at $4^{\circ}C$ for more than 8 months experimented without hemolysis. With low concentration of formalin, the cells were not sufficiently stabilized resulting in the hemolysis after short period of preservation at $4^{\circ}C$. 10. The erythrocytes treated with 16 percent of formalin remain constantly or increase the reactivity for the reaction of hemagglutination. On the contrary, the cells treated with I to 8 percent of formalin decrease the reactivity. 11. There is no difference between nontreated fresh erythrocytes and the erythrocytes preserved in the ACD solution on the reactivity against the hemagglutination, and the erythrocytes treated with 16 percent of formalin showed the reactivity of higher level than that of the above two kinds of erythrocytes. 12. There is no difference between the saline and the isotonic buffer solution on the reaction of hemagglutination.

  • PDF

The Role of Chest CT Scans in the Management of Empyema (농흉에서 전산화 단층촬영의 의의)

  • Heo, Jeong-Suk;Kwun, Oh-Yong;Sohn, Jeong-Ho;Choi, Won-Il;Hwang, Jae-Seok;Han, Seung-Beom;Jeon, Young-June;Kim, Jung-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.4
    • /
    • pp.397-404
    • /
    • 1994
  • Background: To decide the optimal antibiotics and application of chest tube, examination of pleural fluid is fundamental in the management of empyema. Some criteria for drainage of pleural fluid have been recommended but some controversies have been suggested. Recently, newer radiologic methods including ultrasound and computed tomography scanning, have been applied to the diagnosis and management of pleural effusions. We undertook a retrospective analysis of 30 patients with pleural effusion who had CT scans of the chest in order to apply the criteria of Light et al retrospectively to patients with loculation and to correlate the radiologic appearance of pleural effusions with pleural fluid chemistry. Method: We analyzed the records of 30 out of 147 patients with pleural effusion undergoing chest CT scans. Results: 1) Six of the pleural fluid cultures yielded gram negative organisms and three anaerobic bacterias and one Staphylococcus aureus and one non-hemolytic Streptococci. No organism was cultured in ninteen cases(63.0%). 2) The reasons for taking chest CT scans were to rule out malignancy or parenchymal lung disease(46.7%), poor response to antibiotics(40.0%), hard to aspirate pleural fluid(10.0%) and to decide the site for chest tube insertion(3.3%). 3) There was no significant correlations between ATS stages and loculation but there was a tendency to loculate in stage III. 4) There was a significant inverse relationship between the level of pH and loculation(p<0.05) but there appeared to be no relationship between pleural fluid, LDH, glucose, protein, loculation and pleural thickening. 5) In 12 out of 30, therapeutic measures were changed according to the chest CT scan findings. Conclusion: We were unable to identify any correlations between the plerual fluid chemistry, ATS stages and loculations except pH, and we suggest that tube thoracotomy should be individualized according to the clinical judgement and serial observation. All patients with empyema do not need a chest CT scan but a CT scan can provide determination of loculation, guiding and assessing therapy which should decrease morbidity and hospital stay.

  • PDF

Vertical Upward Air-Water Two-Phase Flow Regime Identification (수직상향류 공기-물 이상유동영역 판별)

  • Lee, Ba-Ro;Jang, Young-Jun;Ko, Min-Seok;Lee, Bo-An;Lee, Yeon-Gun;Kim, Sin
    • Journal of Energy Engineering
    • /
    • v.22 no.4
    • /
    • pp.362-369
    • /
    • 2013
  • Two-phase flow is frequently observed in many industries such as nuclear power plants and oil transportation. Two-phase flow regime depends on the flow rates, the fluid properties and the structure of flow channels. Since the identification of the flow regime is of great importance in the system design and the safety analysis, a number of theoretical and experimental investigations have been performed. This paper presents a basic research on the characteristics of each flow regime and transition boundary in the two-phase flows. The flow regime of the upward air-water flow in the vertical tube, 30 mm in the inner diameter, is distinguished by using the high-speed camera and the Wire-mesh sensor(WMS). The identified experimental data are compared with the flow regime maps proposed by Taitel et al, Mishima and Ishii. Even though there is slight difference in the transition boundary, the experimental data show general agreement with these flow regime maps.

BOND STRENGTH OF RESIN CEMENTS TO ZIRCONIA CERAMIC (지르코니아 세라믹과 레진 시멘트의 결합강도)

  • Chang Mun-Suk;Kim Ji-Hye;Cho Suck-Kyu;Bok Won-Mi;Song Kwang-Yeob;Park Ju-Mi
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.426-437
    • /
    • 2005
  • Statement of problem : Although zirconium oxide ceramics are more and more commonly used in restorative dentistry, for many clinical applications only limited data can be found in the literature. However it is quite clear that hydrofluoric acid etching is impossible with zirconia ceramics. Therefore, other bonding techniques are required in order to lute these materials adhesively. Purpose : The purpose or this study was to evaluate the effects of surface treatments on shear bond strengths between two resin cements and a zirconia ceramic. Materials and methods : Experimental industrially manufactured yttrium-oxide-partially-stabilized zirconia ceramic discs (Adens, Korea) were used for this study. The ceramic specimens divided into five experimental groups and a control group (as received). Five surface treatments were studied 1) sandblasting with 110$\mu$m $Al_2O_3$ at 3 bars pressure 13 seconds at a distance of 10 mm, 2) flame-treated with the Silano-Pen for 5 $s/cm^3$, 3) grinding with a diamond bur. 4) sandblasting + Silano-Pen treatment, 5) diamond bur preparation + Silano-Pen treatment. Acrylic plastic tube (5 mm in height and 3 mm in diameter) were filled with composite to fabricate composite cylinders The composite cylinders were bonded to the ceramic specimens with either Superbond C&B or Panavia F resin luting agents. All cemented specimens were tested under shear loading until fracture on universal testing machine at a crosshead speed 1mm/min; the maximum load at fracture was recorded. Sheat bond strength data were analyzed with oneway analysis of variance and Tukey HSD tests (P<.05). Treated ceramic surfaces and fracture surfaces after shear testing were examined morphologically using scanning electron microscope. Results: Ceramic surface treatment with Silano-Pen after sandblasting improved the bond strength of Superbond C&B resin cement. Supevbond C& B resin cement at Silano-Pen aiker sandblasting($27.4{\pm}3.8MPa$) showed statistically higher shear bond strength than the others. Conclusion: Within the limitation of this study, Superbond C& &B resin cement are suitable for cementation of zirconia ceramics and flame-treated with the Silano-Pen after sandblasting is required to enhance the bond strength.

Evolution of Process and Outcome Measures during an Enhanced Recovery after Thoracic Surgery Program

  • Lee, Alex;Seyednejad, Nazgol;Lawati, Yaseen Al;Mattice, Amanda;Anstee, Caitlin;Legacy, Mark;Gilbert, Sebastien;Maziak, Donna E.;Sundaresan, Ramanadhan S.;Villeneuve, Patrick J.;Thompson, Calvin;Seely, Andrew J.E.
    • Journal of Chest Surgery
    • /
    • v.55 no.2
    • /
    • pp.118-125
    • /
    • 2022
  • Background: A time course analysis was undertaken to evaluate how perioperative process-of-care and outcome measures evolved after implementation of an enhanced recovery after thoracic surgery (ERATS) program. Methods: Outcome and process-of-care measures were compared between patients undergoing major elective thoracic surgery during a 9-month pre-ERATS implementation period to those at 1-3, 4-6, and 7-9 months post-ERATS implementation. Outcome measures included length of stay, the 30-day readmission rate, 30-day emergency department visits, and minor and major adverse events. Process measures included first time to activity, out-of-bed, ambulation, fluid diet, diet as tolerated, as well as removal of the first and last chest tube, epidural, patient-controlled analgesia, and Foley and intravenous catheters. Results: In total, 704 patients (352 pre-ERATS, 352 post-ERATS) were included. Mobilization-related process measures, including time to first activity (16.5 vs. 6.8 hours, p<0.001), out-of-bed (17.6 vs. 8.9 hours, p<0.001), and ambulation (32.4 vs. 25.4 hours, p=0.04) saw statistically significant improvements by 1-3 months post-ERATS implementation compared to pre-ERATS. Time to Foley removal improved by 4-6 months post-ERATS (19.5 vs. 18.2 hours, p=0.003). Outcome measures, including the 30-day readmission rate and emergency department visits, steadily decreased post-ERATS. By 7-9 months post-ERATS, both minor (18.2% vs. 7.9%, p=0.009) and major (13.6% vs. 4.4%, p=0.007) adverse events demonstrated statistically significant improvements. Length of stay trended towards improvement from 6.2 days pre-ERATS to 4.8 days by 7-9 months post-ERATS (p=0.06). Conclusion: The adoption of ERATS led to improvements in multiple process-of-care measures, which may collectively and gradually achieve optimization of clinical outcomes.

The Study of Affecting Image Quality according to forward Scattering Dose used Additional Filter in Diagnostic Imaging System (부가필터 사용 시 전방 산란선량에 따른 화질 영향에 대한 연구)

  • Choi, Il-Hong;Kim, Kyo-Tae;Heo, Ye-Ji;Park, Hyong-Hu;Kang, Sang-Sik;Noh, Si-Cheol;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.597-602
    • /
    • 2016
  • Recent clinical field utilizes the aluminium filter in order to reduce the low-energy photons. However, the usage of the filter can cause adverse effect on the image quality because of the scattered dose that is generated by X-ray hardening phenomenon. Further, usage of filter with improper thickness can be a reason of dose creep phenomenon where unnecessary exposure is generated towards the patient. In this study, the author evaluated the RMS and the RSD analysis in order to have a quantitative evaluation for the effect of forward scattering dose by the filter on the image. as a result of the study, the FSR and the RSD was increased together with the increasing of thickness of the filter. In this study the RSD means the standard deviation of the mean value is relatively size. It can be understood that the signal-to-noise ratio decreases when the average value is taken as a signal and the standard deviation is judged as a noise. The signal-to-noise ratio can understanding as index of resolution at image. Based on these findings, it was quantitatively verified that there is a correlation of the image quality with the FSR by using an additional filter. The results, a 2.5 mmAl which is as recommended by NCRP in the tube voltage of 70 kVp or more showed the 14.6% on the RSD when the filter was not in used. these results are considered able to be utilized as basic data for the study about the filter to improve the quality of the image.

Research on Radiation Shielding Film for Replacement of Lead(Pb) through Roll-to-Roll Sputtering Deposition (롤투롤 스퍼터링 증착을 통한 납(Pb) 대체용 방사선 차폐필름 개발)

  • Sung-Hun Kim;Jung-Sup Byun;Young-Bin Ji
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.441-447
    • /
    • 2023
  • Lead(Pb), which is currently mainly used for shielding purposes in the medical radiation, has excellent radiation shielding functions, but is continuously exposed to radiation directly or indirectly due to the harmfulness of lead itself to the human body and the inconvenience caused by its heavy weight. Research on shielding materials that are human-friendly, lightweight, and convenient to use that can block risks and replace lead is continuously being conducted. In this study, based on the commonly used polyethylene terephthalate (PET) film and the fabric material used in actual radiation protective clothing, a multi-layer thin film was realized through sputtering and vacuum deposition of bismuth, tungsten, and tin, which are metal materials that can shield radiation. Thus, a shielding film was produced and its applicability as a radiation shielding material was evaluated. The radiation shielding film was manufactured by establishing the optimized conditions for each shielding material while controlling the applied voltage, roll driving speed, and gas supply amount to manufacture the shielding film. The adhesion between the parent material and the shielding metal thin film was confirmed by Cross-cut 100/100, and the stability of the thin film was confirmed through a hot water test for 1 hour to measure the change of the thin film over time. The shielding performance of the finally realized shielding film was measured by the Korea association for radiation application (KARA), and the test conditions (inverse wide beam, tube voltage 50 kV, half layer 1.828 mmAl) were set to obtain an attenuation ratio of 16.4 (initial value 0.300 mGy/s, measured value 0.018 mGy/s) and damping ratio 4.31 (initial value 0.300 mGy/s, measured value 0.069 mGy/s) were obtained. by securing process efficiency for future commercialization, light and shielding films and fabrics were used to lay the foundation for the application of films to radiation protective clothing or construction materials with shielding functions.

Structural Behavior of Mixed $LiMn_2O_4-LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ Cathode in Li-ion Cells during Electrochemical Cycling

  • Yun, Won-Seop;Lee, Sang-U
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.5-5
    • /
    • 2011
  • The research and development of hybrid electric vehicle (HEV), plug-in hybrid electric vehicle (PHEV) and electric vehicle (EV) are intensified due to the energy crisis and environmental concerns. In order to meet the challenging requirements of powering HEV, PHEV and EV, the current lithium battery technology needs to be significantly improved in terms of the cost, safety, power and energy density, as well as the calendar and cycle life. One new technology being developed is the utilization of composite cathode by mixing two different types of insertion compounds [e.g., spinel $LiMn_2O_4$ and layered $LiMO_2$ (M=Ni, Co, and Mn)]. Recently, some studies on mixing two different types of cathode materials to make a composite cathode have been reported, which were aimed at reducing cost and improving self-discharge. Numata et al. reported that when stored in a sealed can together with electrolyte at $80^{\circ}C$ for 10 days, the concentrations of both HF and $Mn^{2+}$ were lower in the can containing $LiMn_2O_4$ blended with $LiNi_{0.8}Co_{0.2}O_2$ than that containing $LiMn_2O_4$ only. That reports clearly showed that this blending technique can prevent the decline in capacity caused by cycling or storage at elevated temperatures. However, not much work has been reported on the charge-discharge characteristics and related structural phase transitions for these composite cathodes. In this presentation, we will report our in situ x-ray diffraction studies on this mixed composite cathode material during charge-discharge cycling. The mixed cathodes were incorporated into in situ XRD cells with a Li foil anode, a Celgard separator, and a 1M $LiPF_6$ electrolyte in a 1 : 1 EC : DMC solvent (LP 30 from EM Industries, Inc.). For in situ XRD cell, Mylar windows were used as has been described in detail elsewhere. All of these in situ XRD spectra were collected on beam line X18A at National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory using two different detectors. One is a conventional scintillation detector with data collection at 0.02 degree in two theta angle for each step. The other is a wide angle position sensitive detector (PSD). The wavelengths used were 1.1950 ${\AA}$ for the scintillation detector and 0.9999 A for the PSD. The newly installed PSD at beam line X18A of NSLS can collect XRD patterns as short as a few minutes covering $90^{\circ}$ of two theta angles simultaneously with good signal to noise ratio. It significantly reduced the data collection time for each scan, giving us a great advantage in studying the phase transition in real time. The two theta angles of all the XRD spectra presented in this paper have been recalculated and converted to corresponding angles for ${\lambda}=1.54\;{\AA}$, which is the wavelength of conventional x-ray tube source with Cu-$k{\alpha}$ radiation, for easy comparison with data in other literatures. The structural changes of the composite cathode made by mixing spinel $LiMn_2O_4$ and layered $Li-Ni_{1/3}Co_{1/3}Mn_{1/3}O_2$ in 1 : 1 wt% in both Li-half and Li-ion cells during charge/discharge are studied by in situ XRD. During the first charge up to ~5.2 V vs. $Li/Li^+$, the in situ XRD spectra for the composite cathode in the Li-half cell track the structural changes of each component. At the early stage of charge, the lithium extraction takes place in the $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component only. When the cell voltage reaches at ~4.0 V vs. $Li/Li^+$, lithium extraction from the spinel $LiMn_2O_4$ component starts and becomes the major contributor for the cell capacity due to the higher rate capability of $LiMn_2O_4$. When the voltage passed 4.3 V, the major structural changes are from the $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component, while the $LiMn_2O_4$ component is almost unchanged. In the Li-ion cell using a MCMB anode and a composite cathode cycled between 2.5 V and 4.2 V, the structural changes are dominated by the spinel $LiMn_2O_4$ component, with much less changes in the layered $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component, comparing with the Li-half cell results. These results give us valuable information about the structural changes relating to the contributions of each individual component to the cell capacity at certain charge/discharge state, which are helpful in designing and optimizing the composite cathode using spinel- and layered-type materials for Li-ion battery research. More detailed discussion will be presented at the meeting.

  • PDF

Treatment of Potassium Titanyl Phosphate Laser and Radiation Therapv for Tracheal Stenosis (기관 협착에서 레이저와 방사선 치료의 적용)

  • 김광택;김맹호
    • Journal of Chest Surgery
    • /
    • v.30 no.12
    • /
    • pp.1237-1241
    • /
    • 1997
  • Tracheal stenosis is a difficult disease entity to manage. Laser ablation is one effective treatment for treacheal stenosis and can be utilized if tracheal reconstructive surgery is impossible. Potassium titanyl phosphate laser, transmitted via flexible quartz fiber, can be precisely manipulated through flexible bronchoscope under local anesthesia. We treated 7 patients with trach al and broncheal lesion under local anesthesia with KTP laser from January 1995 to July 1996. The patients included three males and four females. The age of patients ranged from 22 to 66 years with a mean of 43.7 years The etiology of tracheal stenosis in patients was stenosis after tracheostomy(3 cases), prolong inturbation in cases of sepsis(1 cases), and the recurrence of lung cancer within endobronchial lesion(2 cases). In the cases of tracheal stenosis treated with laser ablation, there were 2 cases of recurrence of stenosis at the anastomosis site after the operation, 3 cases of stenosis at tracheostomy site, and 2 cases of local recurrence of lung cancer. The site of the tracheal stenosis was the balloon site of the tracheostomy tube(3-4cm inferior to the tracheostomy site, 2-3cm superior to the carina) and the anastomosis site that were narrowed to less than 5mm(4 cases). For the stenosis lesion in the endobronchial area, there were 2 patients with a lesion at the anterior wa l, 1 patient with a lesion at the posterior wall, 2 patients with circumferential stenosis. Laser ablation time was 25.4 $\pm$5.9min and used energy was 1768 $\pm$365J. We have used KTP laser via (lexible bronchoscope without major complications. Adjuvant radiation therapy may prevent fibroblast proliferation which leads to restenosis. In three patients of restenosis after laser ablation, adjuvant irradiation started within 4 hours after laser ablation, and the radiation doses were 1500cGy given in five fraction. In patients with adjuvant radiation therapy, stenosis has not recurred

  • PDF