• 제목/요약/키워드: Al tube

Search Result 343, Processing Time 0.025 seconds

Evaporating Heat Transfer Characteristics of R-l34a in a Horizontal Smooth Channel

  • Pamitran, A.S.;Choi, Kwang-Il;Oh, Jong-Taek;Oh, Hoo-Kyu
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.14 no.4
    • /
    • pp.156-165
    • /
    • 2006
  • Convective boiling heat transfer coefficients were measured in a horizontal minichannel with R-l34a. The test section was made of stainless steel tube with an inner diameter of 3.0 mm and a length of 2m. It was uniformly heated by applying electric current directly to the tube. Local heat transfer coefficients were obtained for heat fluxes from 10 to $40kW/m^2$, mass fluxes from 200 to $600kgT/m^2s$, qualities up to 1.0, and the inlet saturation temperature of $10^{\circ}C$. The experimental results were mapped on Wojtan et $al.'s^(7)$ and Wang et $al.'s^(8)$ flow pattern maps. The nucleate boiling was predominant at low vapor quality whereas the convective boiling was predominant at high vapor quality. Laminar flow appeared in the flow with minichannel. The experimental results were compared with six existing two-phase heat transfer coefficient correlations. A new boiling heat transfer coefficient correlation based on the superposition model for refrigerants was developed with mean and average deviations of 10.39% and -3.66%, respectively.

A FEM Analysis of Remote Field Eddy Current Distribution Characteristics to CANDU Fuel Channel Tube(I) (CANDU형 핵연료 채널 압력관에 대한 원거리장 와전류의 자제분포 특성해석(I))

  • Huh, Hyung;Chung, Hyun-Kyu;Kim, Kern-Jung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.1
    • /
    • pp.59-64
    • /
    • 2002
  • A FEM model of the remote-field eddy current effect is presented for zirconium-2.5 percent niobium(Zr-2.5%Nb) nuclear reactor pressure tubes to demonstrate the important electromagnetic field phenomena. This model is applied to evaluate the optimal operating frequency and detector position. There are many ambiguous experimental results connected with this technique. Finite element calculations can be used in the interpretation of these experimental results even though the electromagnetic fields measured in the remote-field technique are very small.

Physical Properties of Heavy Elements as Filter in Diagnostic Radiology (진단방사선영역에서 중원소 여과판의 물리적 특성)

  • Kim, Y.K.;Lee, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1977-1979
    • /
    • 1999
  • This work characterized in terms of the physical properties of heavy elements as reduction filter in the diagnostic radiology. From the results of experimental evaluation, it was founded that in the case of the Ho filter, the variety of X-ray property with kVp was less than those of Ba, Cu and Al. And the ratio of transit-dose to surface and the load of X-ray tube were increased in the order of Al, Ba, Cu and Ho. The contrast of X-ray image showed the higher value in the order of Cu, Al, Ba and Ho.

  • PDF

Unsteady State Analysis of Al Tube Hot Extrusion by A Porthole Die (포트홀 다이에 의한 Al 튜브의 비정상상태 열간 압출 공정 해석)

  • 조형호;이상곤;박종남;김병민
    • Transactions of Materials Processing
    • /
    • v.10 no.4
    • /
    • pp.311-318
    • /
    • 2001
  • Porthole die extrusion has a great advantage in the forming of long hollow section tubes. It is difficult to produce long hollow section tubes with complicated section by the conventional extrusion process with a mandrel on the stem Because of the limit of the length of mandrel and the complexity of cross section. Porthole die extrusion is affected by many parameters, such as extrusion ratio, extrusion speed, die geometry, porthole number, bearing length etc. Up to now, most of studies about porthole die extrusion have been investigated by experiments or steady state FE-analysis. However, in this paper, porthole die extrusion is analysed by the unsteady state 3D FE-simulation. And the result of unsteady state analysis is compared with the experimental result. Also, the surface state of extruded tubes are examined for the various process conditions.

  • PDF

Propane Dehydrogenation over a Hydrogen Permselective Membrane Reactor

  • Chang, Jong-San;Roh, Hyun-Seog;Park, Min-Seok;Park, Sang-Eon
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.5
    • /
    • pp.674-678
    • /
    • 2002
  • The dehydrogenation of propane to propylene has been studied in an isothermal high-temperature shell-and-tube membrane reactor containing a Pd-coated ${\psi}$-Al2O3 membrane and a Pt/K/Sn/Al2O3 packed catalyst . A tubular Pd-coated ${\psi}$-Al2O3 membrane was prepared by an electroless plating method. This membrane showed high hydrogen to nitrogen permselectivities (PH2N2 = 10-50) at 400 $^{\circ}C$ and 500 $^{\circ}C$ with various transmembrane pressure drops. The employment of a membrane reactor in the dehydrogenation reaction, which selectively separates hydrogen from the reaction mixture along the reaction path, can greatly increase the conversion and enable operation of the reactor at lower temperatures. High hydrogen permselectivity has been confirmed as a key factor in determining the reactor performance of conversion enhancement.

A Study on the Reduction of Exposure Dose and Contrast Improvement by Use of Heavy Elements Filter (X선 진단영역에서 중원소(Ho) 여과판 사용에 따른 피폭선량 감소와 대조도 개선에 관한 연구)

  • Kim, Young-Keun
    • Journal of radiological science and technology
    • /
    • v.23 no.1
    • /
    • pp.91-96
    • /
    • 2000
  • This work was on the reduction of exposure dose and contrast improvement by Use of Heavy Elements Filter From the result of experimental evaluation, it was found that the beam harding of X-ray was not showed in Ho and Gd, heavy elements filters, contrast to Cu and Al filters In which the harding showed. And the ratio of transit dose to surface dose and the load of X-ray tube increase in order of Al, Cu, Gd and Ho, respectively. The contrast of X-ray images using the intensifying screen and the input phosphor showed the higher value in order of Cu, Al, Gd and Ho. Therefore, in the case of using contrast media and phosphor in region of diagnostic radiology, X-ray image quality depends primarily on kVp and heavy elements filters.

  • PDF

Secondary Growth of Sodium Type Faujasite Zeolite Layers on a Porous $\alpha-Al_2O_3$ Tube and the $CO_2/N_2$ Separation (Na형 Faujasite 제올라이트 분리막 형성 및 $CO_2/N_2$ 분리)

  • Cho, Churl-Hee;Yeo, Jeong-Gu;Ahn, Young-Soo;Han, Moon-Hee;Kim, Yong-Ha;Hyun, Sang-Hoon
    • Membrane Journal
    • /
    • v.17 no.3
    • /
    • pp.254-268
    • /
    • 2007
  • Sodium type faujasite(FAU) zeolite layers with diverse materials characteristics(Si/Al ratio, thickness, and structural discontinuity) were hydrothermally grown on a porous $\alpha-Al_2O_3$ tube, and then the $CO_2/N_2$ separation was evaluated at $30^{\circ}C$ for an equimolar mixture of $CO_2$ and $N_2$. Among hydrothermal conditions, $SiO_2$ content in hydrothermal solution seriously affected materials characteristics: with an increment in the $SiO_2$ content, Si/Al ratio, thickness, and structural discontinuity of grown FAU zeolite layer simultaneously increased. The present study reveals that structural discontinuity(intercrystalline voids due to an incomplete densification and cracks induced by GIS Na-P1 phase) is the most important variable affecting the $CO_2/N_2$ separation. Also, it was suggested that the $CO_2$ desorption in permeate side be the rate-determining(slowest) step in the overall $CO_2$ permeation.

Numerical simulation and analytical assessment of STCC columns filled with UHPC and UHPFRC

  • Nguyen, Chau V.;Le, An H.;Thai, Duc-Kien
    • Structural Engineering and Mechanics
    • /
    • v.70 no.1
    • /
    • pp.13-31
    • /
    • 2019
  • A nonlinear finite element model (FEM) using ATENA-3D software to simulate the axially compressive behavior of circular steel tube confined concrete (CSTCC) columns infilled with ultra high performance concrete (UHPC) was presented in this paper. Some modifications to the material type "CC3DNonlinCementitious2User" of UHPC without and with the incorporation of steel fibers (UHPFRC) in compression and tension were adopted in FEM. The predictions of utimate strength and axial load versus axial strain curves obtained from FEM were in a good agreement with the test results of eighteen tested columns. Based on the results of FEM, the load distribution on the steel tube and the concrete core was derived for each modeled column. Furthermore, the effect of bonding between the steel tube and the concrete core was clarified by the change of friction coefficient in the material type "CC3DInterface" in FEM. The numerical results revealed that the increase in the friction coefficient leads to a greater contribution from the steel tube, a decrease in the ultimate load and an increase in the magnitude of the loss of load capacity. By comparing the results of FEM with experimental results, the appropriate friction coefficient between the steel tube and the concrete core was defined as 0.3 to 0.6. In addition to the numerical evaluation, eighteen analytical models for confined concrete in the literature were used to predict the peak confined strength to assess their suitability. To cope with CSTCC stub and intermediate columns, the equations for estimating the lateral confining stress and the equations for considering the slenderness in the selected models were proposed. It was found that all selected models except for EC2 (2004) gave a very good prediction. Among them, the model of Bing et al. (2001) was the best predictor.

A Characteristics on Water Quality Analysis Used the High-Voltage Discharge (고전압 방전을 이용한 수질분식에 관한 특성)

  • Cho, Kook-Hee;Kim, Young-Bae;Cho, Moon-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.156-161
    • /
    • 2004
  • In this research, we used discharge tube without dielectric bead or with dielectric beads(SiO$_2$, $Al_2$O$_3$, or ZrO$_2$), and discharge in water at High-voltage pulse$.$DC power supply for removal of Escherichia coli. At the result of experiments, the removal characteristics of Escherichia coli appeared relation ratio to input voltage. Because, the electric field of discharge tube is increased when input voltage is increased. And, discharge tube used dielectric bead(ZrO$_2$), the removal characteristics of Escherichia coli was better than cases of else. And discharge used DC Power, the removal characteristics of Escherichia coli was better than AC Pulse Power.

Heat Transfer Characteristics of Carbon Dioxide in a Inclined Helical Coil Type Heat Exchanger with Inner Diameter Tube of 4.55 mm (내경 4.55 mm의 경사진 헬리컬 코일형 열교환기내 이산화탄소의 열전달 특성에 관한 연구)

  • Son, Chang-Hyo
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.3
    • /
    • pp.1-6
    • /
    • 2007
  • The heat transfer coefficient and pressure drop during gas cooling process of $CO_2$ (R-744) in inclined helical coil copper tubes were investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and a inclined helical coil type gas cooler (test section). The test section consists of a smooth copper tube, which is specified as the inner diameter of 4.55 mm. The refrigerant mass fluxes were varied from 200 to $600kg/m^2s$ and the inlet pressures of gas cooler were done 7.5 to 10.0 (MPa). The heat transfer coefficients of $CO_2$ in the inclined helical coil tubes increase with the increase of mass flux and gas cooling pressure of $CO_2$. The pressure drop of $CO_2$ in the gas cooler shows relatively good coincidence with those predicted by Ito's correlation developed for single-phase in a helical coil tube. The local heat transfer coefficient of $CO_2$ is well coincident with the correlation by Pitla et al. However, at the region near pseudo-critical temperature, the experiments indicate higher values than the Pitla et al. correlation.

  • PDF