• Title/Summary/Keyword: Al plate

Search Result 569, Processing Time 0.025 seconds

The Applicability Analysis of FDS code for Fire-Driven Flow Simulation in Railway Tunnel (철도터널 화재 유동에 사용되는 FDS code의 적용성 분석)

  • Jang, Yong-Jun;Park, Won-Hee
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.2 s.39
    • /
    • pp.224-230
    • /
    • 2007
  • The performance and applicability of FDS code is analyzed for flow simulation in railway tunnel. FDS has been built in NIST(USA) for simulation of fire-driven flow. RANS and DNS's results are compared with FDS's. AJL non-linear ${\kappa}-{\epsilon}$[7,8] model is employed to calculate the turbulent flow for RANS. DNS data by Moser et al.[9] are used to prove the FDS's applicability in the near wall region. Parallel plate is used for simplified model of railway tunnel. Geometrical variables are non-dimensionalized by the height (H) of parallel plate. The length of streamwise direction is 50H and the length of spanwise direction is 5H. Selected Re numbers are 10,667 for turbulent flow and 133 for laminar low. The characteristics of turbulent boundary layer are introduced. AJL model's predictions of turbulent boundary layer are well agreed with DNS data. However, the near wall turbulent boundary layer is not well resolved by FDS code. Slip conditions are imposed on the wall but wall functions based on log-law are not employed by FDS. The heavily dense grid distribution in the near wall region is necessary to get correct flow behavior in this region for FDS.

Evaluation of Microbiological Hazards of Baking Utensils and Environment of Bakeries (일부 베이커리업체의 조리용기.기구 및 작업환경에 대한 미생물적 위해분석)

  • 김은미;김현숙
    • Culinary science and hospitality research
    • /
    • v.7 no.3
    • /
    • pp.85-98
    • /
    • 2001
  • This study was performed to describe the overall sanitation of baking utensils and equipments, employees, and environment in 9 bakeries. Microbiological tests on employees, utensils and equipments, were done according to standard procedure and included total plate count, coliforms, fungi and Staphylococcus aureus.. Microbiological testing is a value in determining hazards for developing a HACCP plan but were not detected throat and employee's hands before use. Staphylococcus aureus was detected nasal cavity and employees's hands after use. Employee's apron after use was detected fungi and coliform and was risk factor of cross-contamination to bread or cookies et al. Generally hygienic conditions of pan, kitchen board, knife, brush, and wooden scoop were worse than those of other baking utensils such as tray, bread tweezers, dusting brush and dish cloth. And refrigerator, freezer and fermentation chamber were detected fungi and coliforms. Total plate count of heating table, working table, distribution table, washbowl and refrigerator was increased in 2nd period. Temperature of refrigerator was 10.43$^{\circ}C$ and strict temperature control of refrigerations needs. Therefore, baking utensils and equipments were reguraly need to sterilize and clean. Additionary, it need to practice the effective sanitation education and training program for the bakery managers and employees.

  • PDF

The effect of Pellet about $DeNO_x$ for Packed-bed type reactor (Packed-bed type 반응기에서 $NO_x$제거에 대한 Pellet의 영향)

  • Park, Jae-Yoon;Lee, Kyunh-Ho;Lee, Dong-Hoon;Kim, Jung-Dal;Park, Sang-Hyun;Koh, Hee-Suk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05b
    • /
    • pp.203-206
    • /
    • 2000
  • In this experiment, an attempt to use pellets($BaTiO_3$, $TiO_2$, ${\gamma}-Al_2O_3$, sludge) for $NO_x$ removal was conducted The effect of pellets on NO removal from simulated flue gas was experimentally investigated for packed-bed reactor of plate-plate geometry. An experimental investigation has been conducted for NO concentration of 50ppm balanced by air, and gas flow rate of $5{\ell}/min$. Ceramic pellets were used for surface discharge and the sludge pellets was added on $BaTiO_3$ and $TiO_2$ to increase $NO_x$ removal rate. In the result, $NO_x$ removal rate using $TiO_2$ was better than other pellets. $NO_2$ segnificatly generated by using $BaTiO_3$ pellets and sludge pellets used with $BaTiO_3$ decreased $NO_2$ generation.

  • PDF

New Record of the Freshwater Dinoflagellate Peridinium umbonatum Stein (Dinophyceae) from Togyo Reservoir, Korea

  • Ki, Jang-Seu;Han, Myung-Soo
    • ALGAE
    • /
    • v.23 no.2
    • /
    • pp.115-118
    • /
    • 2008
  • Cells of the dinoflagellate Peridinium were frequently observed in water samples of Togyo reservoir, and some species were responsible for dense blooms. Recently, we could identify them as P. bipes f. occultatum Lindem. and P. aciculiferum Lemm., considering morphology (Ki et al. 2005a; Ki and Han 2005b): However, some unidentified Peridinium cells with different shapes and body sizes were found among the samples collected during early spring. Here we describe their morphological characteristics such as thecal plate and body size to characterize its taxonomic identity by morphological characters. The formula of epithecal plates was recorded as 4 apical, 2 intercalary and 7 precingular plates (i.e. 4’', 2a, 7’'’') and the epicone in an apical view was symmetric. An apical pore was easy to make out under a light microscope. No cingular displacement was observed. The average body size was 33 $\mu$m in length with a range of 26-36 $\mu$m, and average 26 $\mu$m in width with a range of 21-31 $\mu$m, respectively; the cell was, therefore, shown slightly elongated. This way we identified Peridinium umbonatum Stein, 1883 for the first time from Korean freshwaters.

Characteristics of Turbulent Impinging and Wall Jet Flow for a Circular Nozzle with Various Exit Wall Thickness (다양한 벽면 두께를 갖는 원형 노즐에서 분사되는 난류 충돌 및 벽면 제트 유동장 특성)

  • Yang, Geun-Yeong;Yun, Sang-Heon;Son, Dong-Gi;Choe, Man-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.6
    • /
    • pp.751-757
    • /
    • 2001
  • An experimental study of impinging jet-flow structure has been carried out for a fully developed single circular jet impingement cooling on a flat plate, and the effect of the wall thickness at nozzle exit edge is investigated. Impinging jet flow structures have been measured by Laser-Doppler Velocimeter to interpret the heat transfer results presented previously by Yoon et al.(sup)(10) The peaks of heat transfer rate are observed near the nozzle edge owing to the radial acceleration of jet flow when the nozzle locates close to the impingement plate. The growth of the velocity fluctuations in the wall jet flow is induced by the vortices which originate in the jet shear layer, and consequently the radial distribution of local Nusselt numbers has a secondary peak at the certain radial position. As a wall of circular pipe nozzle becomes thicker for small nozzle-to-target distance, the entrainment can be inhibited, consequently, the acceleration of wall jet flow is reduced and the heat transfer rate decreases.

Fatigue Strength Depending on Position of Cracks for Weldments

  • Lee Hae-Woo;Park Won-Jo
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.675-680
    • /
    • 2006
  • This is a study of fatigue strength of weld deposits with transverse cracks in plate up to 50 mm thick. It is concerned with the fatigue properties of welds already with transverse cracks. A previous study of transverse crack occurrence, location and microstructure in accordance with welding conditions was published in the Welding Journal (Lee et al., 1998). A fatigue crack develops as a result of stress concentration and extends with each load cycle until fatigue occurs, or until the cyclic loads are transferred to redundant members. The fatigue performance of a member is more dependent on the localized state of stress than the static strength of the base metal or the weld metal. Fatigue specimens were machined to have transverse cracks located on the surface and inside the specimen. Evaluation of fatigue strength depending on location of transverse cracks was then performed. When transverse cracks were propagated in a quarter-or half-circle shape, the specimen broke at low cycle in the presence of a surface crack. However, when the crack was inside the specimen, it propagated in a circular or elliptical shape and the specimen showed high fatigue strength, enough to reach the fatigue limit within tolerance of design stresses.

A Fracture Analysis on the Ceramic Dome with Different Geometry under Impact (충격을 받는 세라믹돔의 기하형상에 따른 파괴해석)

  • Kwon, Sun-Guk;Lee, Yung-Shin;Kim, Jae-Hoon;Lee, Jung-Hee;Yoon, Su-Jin
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.706-710
    • /
    • 2008
  • The experiment of dome port cover under shock impact is performed with shock tube. The dome port cover blocked intake air duct up from the solid propellant during air breathing vehicle speed reach Mach 2.0. When the air breathing vehicle reach Mach 2.0, the inlet cover is removed and the dome port cover is broken to pieces by detonator or pressure of inlet air. Thus the dome port cover not only must stand the pressure of combustion chamber but also easy to break from the RAM pressure. In this study, a fracture evaluation on the $Al_2O_3$ ceramic spherical dome and circular plate port under impact has been presented. Ceramic were supported by the rigid body and a couple of O-ring. The Mooney-Rivlin model have been used to describe behaviors of both O-ring. And spherical dome and circular plate fracture results of the LS-DYNA code using Johnson-Holmquist(JH-2) constitutive equation was compared.

  • PDF

A Study On Shape Design of Implant Systems For Bone Fracture Operations By Using Finite Element Method (유한요소법을 이용한 골절치료용 임플란트 시스템 형상설계에 관한 연구)

  • Cho, Ji-Hyun;Seo, Keum-Hee;Seo, Tae-il
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.3
    • /
    • pp.425-432
    • /
    • 2012
  • This paper investigates shape design processes of two implant systems for bone fracture treatment ; Bone plate and Interlocking nail system. These systems can directly fix fractured human bones by surgical operations. The bone plates consist of various shaped plates and implant screws for fixation of fractured human bones with various manual instruments allowing to handle them. The material corresponds to titanium alloy Ti6Al4V because it is harmless material for human body as well as significantly rigid. This system has to be suitably rigid as well as manually bended in orthopedic surgery operations. The Interlocking nail system is a kind of nail implanted inside fractured human bones. The shapes of these systems have to be suitably designed in order to endure various loads as well as avoid any damages. If various shaped prototypes would be fabricated and tested to design the optimal shapes, optimal shapes could be obtained but very long time and expensive costs must be required. In this paper finite element method was applied into these systems. Under various boundary conditions a series of structural analysis was conducted by using ANSYS. Finally important shape factors could be determined on the basis of the analysis results.

Experimental Investigation on the Drag Reduction for an Axi-symmetric Body by Micro-bubble and Polymer Solution

  • Yoon, Hyun-Se;Park, Young-Ha;Van, Suak-Ho;Kim, Hyung-Tae;Kim, Wu-Joan
    • Journal of Ship and Ocean Technology
    • /
    • v.8 no.1
    • /
    • pp.1-9
    • /
    • 2004
  • Experiments on friction drag reduction by injecting polymer (Polyethylene oxide) solution or micro-bubbles were carried out in the cavitation tunnel of KRISO. Two different drag reduction mechanisms were applied to a slender axi-symmetric body to measure the total drag reduction. And then the amount of friction drag reduction was estimated under the assumption that the reduction mechanisms were effective only to the friction drag component. As the result of the tests, polymer solution drag reduction up to 23% of the total drag was observed and it corresponds to about 35% of the estimated friction drag of the axi-symmetric body. This result matched reasonably well to that of the flat plate test "(Kim et al, 2003)". The normalization of the controlling parameters was tried at the end of this paper. Micro-bubble drag reduction was within 1% of its total drag. This unexpected result was quite different from that of the flat plate case "(Kim et at, 2003)" The possible reasons were discussed in this paper.

Bending Performance Evaluation of Reinforced Aluminum Square Tube Beams (보강 알루미늄 사각관 보의 굽힘 성능평가)

  • Lee Sung-Hyuk;Choi Nak-Sam
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.5
    • /
    • pp.171-180
    • /
    • 2005
  • Bending performances of aluminum square tube beams reinforced by aluminum plates under three point bending loads have been evaluated using experimental tests combined with theoretical and finite element analyses. A finite element simulation for the three-point bending test was performed. Basic properties of aluminum materials used for initial input data of the finite element simulation were obtained from the true stress-true strain curves of specimens which had been extracted from the Al tube beams. True stresses were determined from applied loads and cross-sectional area records of a tensile specimen with a rectangular cross-section by real-time photographing, and true strains were obtained from in-situ local elongation measurements of the specimen gage portion by the multi-point scanning laser extensometer. Six kinds of aluminum tube beam specimens adhered by aluminum plates were employed fur the bending test. The bending deformation behaviors up to the maximum load described by the numerical simulation were in good agreement with experimental ones. After passing the maximum load, reinforcing plate was debonded from the aluminum tube beam. An aluminum tube beam strengthened by aluminum plate on the upper web showed an excellent bending capability.