• Title/Summary/Keyword: Airborne pollutants

Search Result 69, Processing Time 0.029 seconds

A Study on the Quantitative Analysis of SO$_2$ Dry Deposition in the Northeastern Asia (동북아 지역에서의 SO$_2$ 건성 침적에 관한 정량분석)

  • 홍민선;김순태;이동섭
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.3
    • /
    • pp.231-241
    • /
    • 1997
  • A tracer model was applied in the Far East Asia to investigate the dry deposition rates of air pollutants on Korean Peninsula originated from different countries including China and Japan. Wind direction was chosen to predict the maximum deposition rates and SO$_2$ was chosen as a tracer to estimate the source strength. Model simulation shows that inflow, deposition and airborne ratios of China-originated SO$_2$ were 50%, 8% and 30%, respectively, at most. Also it was found that deposition, outbounded and airborne ratios of Korea-originated SO$_2$ were 15~77%, 8~75%, and 3~30%, respectively Model simulation also shows that inflow, deposition and airborne ratios of Kyushu-originated SO$_2$ were, 30~45%, 8~14% and 20~25%, respectively. This study shows that tracer model can be applied on the estimation of air pollutants partitioning in regional scale and that more sophisticated modules and schemes can be developed and applied to better predict the transboundary amounts of air pollutants in this region.

  • PDF

Reduction Effect of Airborne Pollutants in Pig Building by Air Cleaner Operated with Plasma Ion (플라즈마 이온 방식의 공기정화기를 이용한 돈사내 공기오염물질 저감 효과)

  • Kim, Yoon-Shin;Kim, Ki-Youn;Cho, Man-Su;Ko, Moon-Suk;Ko, Han-Jong;Jung, Jin-Won;Oh, Mi-Seok;Youn, Baek;Kim, Jung-Ho
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.4
    • /
    • pp.306-312
    • /
    • 2010
  • This field study was performed to evaluate the efficiency of a plasma ion-operated air cleaner in temporal reduction of airborne pollutants emitted from a pig housing facility. In the case of gaseous pollutants, the plasma ion air cleaner was not effective in reducing levels of ammonia, hydrogen sulfide, nitrogen dioxide, or sulfur dioxide (p>0.05). In the case of particulate pollutants, however, the air cleaner was effective in reducing levels of particulate matter ($PM_{2.5}$ and $PM_1$) by 79(${\pm}6.1$) and 78(${\pm}3.0$)%, respectively. Unlike the case of these fine particle fractions, the reduction of total suspended particles (TSP) and $PM_{10}$ following treatment was almost negligible. In the case of biological pollutants, the mean reduction efficiencies for airborne bacteria and fungi were relatively low at 22(${\pm}6.6$) and 25(${\pm}8.7$)%, respectively. Taken together, these results indicate that in terms of air pollutants released from this pig housing facility, the plasma ion air cleaner was primarily effective in reducing levels of $PM_{2.5}$ and $PM_1$.

Aircraft Measurement of SO$_2$, NO$_{x}$ over Yellow Sea Area (항공기를 이용한 서해안에서의 SO$_2$ 및 NO$_{x}$의 측정)

  • 김병곤;차준석;한진석;박일수;김정수;나진균;최덕일;안준영;강창국
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.5
    • /
    • pp.361-369
    • /
    • 1997
  • In order to investigate the abundance and transboundary fluxes of air pollutants over the Yellow Sea, airborne measurements were made aboard the SF-600 aircraft (Pan-Asia Engineering) in March, 1996. The data presented in this paper are preliminary results and airborne experiment will be carried out until 1999. The vertical profile of relevant meteorological parameters such as temperature, water vapor, wind direction and wind speed were also observed at Taean. Mixing layer height was about 1000~1100m during the flights. The SO$_2$ and NO$_{x}$ concentrations were 3~6 ppb and 5~7 ppb below 1000 m, within 1 ppb and 3~5 ppb at 1000~2000m, respectively. Backward trajectory analyses were also carried out. A mathematical method by Lelieveld et al.(1989) was used to estimate the flux of air pollutants through the planetary boundary layer of Yellow Sea area. Transboundary fluxes were calculated using the measurement results with respect to the pollutants concentration, depth of the planetary boundary layer, wind speed and wind direction. The estimated transboundary flux of SO$_2$through the western boundary of Korea was about 39~42 tons/hour.r.

  • PDF

Control of Airborne Organic Pollutants Using Plug-Flow Reactor Coated With Carbon Material-Titania Mixtures Under Visible-Light Irradiation

  • Jo, Wan-Kuen;Kang, Hyun-Jung;Kim, Mo-Keun
    • Journal of Environmental Science International
    • /
    • v.22 no.10
    • /
    • pp.1263-1271
    • /
    • 2013
  • Graphene oxide (GO)-titania composites have emerged as an attractive heterogeneous photocatalyst that can enhance the photocatalytic activity of $TiO_2$ nanoparticles owing to their potential interaction of electronic and adsorption natures. Accordingly, $TiO_2$-GO mixtures were synthesized in this study using a simple chemical mixing process, and their heterogeneous photocatalytic activities were investigated to determine the degradation of airborne organic pollutants (benzene, ethyl benzene, and o-xylene (BEX)) under different operational conditions. The Fourier transform infrared spectroscopy results demonstrated the presence of GO for the $TiO_2$-GO composites. The average efficiencies of the $TiO_2$-GO mixtures for the decomposition of each component of BEX determined during the 3-h photocatalytic processes were 26%, 92%, and 96%, respectively, whereas the average efficiencies of the unmodified $TiO_2$ powder were 3%, 8%, and 10%, respectively. Furthermore, the degradation efficiency of the unmodified $TiO_2$ powder for all target compounds decreased during the 3-h photocatalytic processes, suggesting a potential deactivation even during such a short time period. Two operational conditions (air flow entering into the air-cleaning devices and the indoor pollution levels) were found to be important factors for the photocatalytic decomposition of BEX molecules. Taken together, these results show that a $TiO_2$-GO mixture can be applied effectively for the purification of airborne organic pollutants when the operating conditions are optimized.

Emission of Airbone Pollutants from Traditional Korean Fireplace (아궁이 사용에 의한 대기오염물질의 배출 특성)

  • Park, Sung Kyu;Lyu, Kun Jung;Choi, Sang Jin;Kim, Dae keun;Kim, Dong Young;Jang, Young Kee
    • Journal of Climate Change Research
    • /
    • v.6 no.2
    • /
    • pp.113-119
    • /
    • 2015
  • Emission from the traditional Korean fireplace, or the under-floor heating and cooking device, can contribute significantly to airborne pollutants inventories. This study has systematically measured emissions of airborne pollutants from the fireplace when used different fuels such as firewood, agricultural crop residuals, household wastes. The results show that emission factors of airborne pollutants through the primary combustion of firewood were 3.22 g/kg for TSP, 2.93 g/kg for $PM_{10}$, 2.65 g/kg for $PM_{2.5}$, 174.19 g/kg for CO, 7.77 g/kg for NO, 0.15 g/kg for $SO_2$, 40.53 g/kg for TVOC and 0.03 g/kg for $NH_3$; from burning of agricultural crop residues, 2.85 g/kg for TSP, 1.38 g/kg for $PM_{10}$, 1.14 g/kg for $PM_{2.5}$, 126.47 g/kg for CO, 12.60 g/kg for NO, 0.20 g/kg for $SO_2$, 33.73 g/kg for TVOC and 0.02 g/kg for $NH_3$; and for household wastes, 10.52 g/kg for TSP, 8.52 g/kg for $PM_{10}$, 6.23 g/kg for $PM_{2.5}$, 72.86 g/kg for CO, 11.73 g/kg for NO, 0.20 g/kg for $SO_2$, 47.10 g/kg for TVOC and 0.20 g/kg for $NH_3$.

The Need for QA/QC in the Measurements of Airborne Pollutants - Conduction of and Directions towards an Interlaboratory Comparison Test in 1998 by the Measurement and Analysis Division of KOSAE (대기오염측정에 대한 정도관리의 필요성 - 1998년도 한국대기환경학회 측정분석분과회의 실험실간 비교분석사업 시행과 전개방향)

  • 김기현;이강웅;김조천;서영화;이종해;허귀석
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.1
    • /
    • pp.63-69
    • /
    • 1999
  • To offer a general guideline for the quantitative analysis of airborne pollutants, we designed and conducted a comprehensive QA/QC test using two different strategic approaches, namely (1) field-based comparative measurement and (2) laboratory-based comparative analysis. The former task was performed to make meaningful comparison of combined errors occurring from both sampling and analytical techniques in the measurements of such components as: (1) criteria pollutants, (2) volatile organic compounds (VOCs), and (3) particulate matters with the associated metals and ions. The latter task was also conducted to compare various types of bias arising mainly from the laboratory analytical procedures of (1) gaseous standards of VOCs and (2) of aqueous standards of metals and ions. The concentration data derived from each of these two different types of major tasks were evaluated per chemical species categorized as above. While the very details of these studies are to be reported on an individual basis according to the above classification of the project, this paper is presented to provide an overview of the whole project - its aim and direction.

  • PDF

Distribution of Airborne Fungi in the Public Facilities (다중이용시설 내 공기 중의 진균 분포)

  • Koh, Yeon-Ja;Gong, Young-Woo;Lee, Jae-Mann;Go, Jong-Myoung;Kim, Yong-Hee;JeGal, Seung
    • Journal of environmental and Sanitary engineering
    • /
    • v.22 no.4
    • /
    • pp.77-85
    • /
    • 2007
  • Recently, there is increasing interest in indoor air pollution. Fungal spores are one of the pollutants that is the causes of hypersensitivity reactions, bronchial asthma, allergic rhinitis. This study was performed to assess the levels of fungi concentration in public facilities and airborne fungi were collected with the air sampler using DRBC(Dichloran rose bengal chloramphenicol) agar. It was found that airborne fungi concentration were related to the humidity and the people movement. 10 genera of fungi was isolated and identified and the most common culturable fungi were Penicillium, Cladosporium, and Aspergillus.

Health Risk Assessment of Airborne Volatile Organic Compounds in Ulsan Industrial Complex (울산공단지역의 대기중 휘발성 유기화합물에 대한 인체 위해도 평가)

  • 이진홍;남병현;윤미정
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1999.06a
    • /
    • pp.271-276
    • /
    • 1999
  • 미국을 비롯한 선진국들은 이미 휘발성 유기화합물(volatile organic compounds) 과 독성 중금속(toxic metals)을 비롯한 유해 대기오염물(hazardous air pollutants)에 대해 ATEOS (Airborne Toxic Element and Organic Species), TEAM(Total Exposure Assessment Measurement) 연구등의 대규모 연구를 통하여 인체에 미치는 영향이 가장 큰 물질군이 휘발성 유기화합물임을 밝혀낸 바 있다. (중략)

  • PDF

Comparative measurements of Criteria Pollutants Using DOAS and Conventional In-situ Monitoring Technique at Sung Nam city of Korea

  • Kim, Ki-Hyun;Jin, Byong-Bok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.E4
    • /
    • pp.169-181
    • /
    • 2001
  • To test the compatibility of differential optical absorption spectroscopy (DOAS) and conventional in-situ monitoring technique we conducted a comparative analysis of the two systems using hourly measurement data sets of three criteria pollutants including No$_{2}$O$_{3}$, and SO$_{2}$ collected in months between April and June of 2001 at Sung Man city, Kyung Gi Province, Korea. The results of our comparative analysis were useful to evaluate the various aspects of DOAS performance, of particular the level of agreement with the counterpart method through computation of percent differences and correlation analysis. Interpretation of the mixing ratio data for those chemical species was however confined in terms of explaining the differences affected by the changes in environmental conditions because measurements of important meteorological parameters were limited during most of the study period. Nevertheless, the overall results of this study strongly demonstrated that the mixing ratio of major pollutants measured by the two different systems maintain strong compatibility from various respects.

  • PDF

Biomonitoring the Genotoxicity of Environmental Pollutants Using the Tradescantia Bioassay (환경 중 유전독성물질 검색을 위한 자주달개비 생물검정 기법의 적용연구)

  • 신해식
    • Proceedings of the Korea Society of Environmental Toocicology Conference
    • /
    • 2004.05a
    • /
    • pp.47-60
    • /
    • 2004
  • Higher plants can be valuable genetic assay systems for monitoring environmental pollutants and evaluating their biological toxicity. Two assays are considered ideal for in situ monitoring and testing of soil, airborne and aqueous mutagenic agents; the Tradescantia stamen hair assay for somatic cell mutations and the Tradescantia micronucleus assay for chromosome aberrations. Both assays can be used for in vivo and in vitro testing of mutagens. Since higher plant systems are now recognized as excellent indicators and have unique advantages over in situ monitoring and screening, higher plant systems could be accepted by regulatory authorities as an alternative first-tier assay system for the detection of possible genetic damages resulting from the pollutants or chemicals used and produced by industrial sectors. It has been concluded that potential mutagen and carcinogen such as the heavy metals among indoor air particulates, volatile compounds in the working places, soil, and water pollutants contribute to the overall health risk. This contribution can be considerable under certain circumstances. It is therefore important to identify the level of genotoxic activity in the environment and to relate it to the biomarkers of a health risk in humans. The results from the higher plant bioassays could make a significant contribution to assessing the risks of pollutants and protecting the public from agents that can cause mutation and/or cancer. The plant bioassays, which are relatively inexpensive and easy to handle, are recommended for the scientists who are interested in monitoring pollutants and evaluating their environmental toxicity to living organisms.

  • PDF