• 제목/요약/키워드: AirKorea

검색결과 24,406건 처리시간 0.052초

공기부양판을 적용한 에어쿠션 트랜스포터의 개발 (Development of Air Cushion Transporter Using the Pneumatic Floating Pad)

  • 정현목;홍준희;윤동원;박희창;김병인;이성휘
    • 한국생산제조학회지
    • /
    • 제25권5호
    • /
    • pp.338-344
    • /
    • 2016
  • Recent trends in transport system for carrying heavy freight are that demands of a high efficiency, economic efficiency, convenience and safety are increased. Conventional transport systems were poor in transport efficiency and economic efficiency. And Safety problems can be caused to products and workers. In order to overcome these problems, an air cushion transport device with a high-pressure air is required. The air cushion transporter is a device for reducing the frictional force of floor surface and lifting the heavy freight by spraying the high-pressure air to the floor. Technology to float and transfer freight using high-pressure air is very convenient and initial cost can be reduced. In this paper, the study on the levitation performance and transport efficiency of air cushion transport system is conducted and verified that air cushion transporter has a significantly higher transport efficiency than conventional heavy handling systems.

항공기 관제 디스플레이의 생태학적 인터페이스 디자인에 관한 연구 (Ecological Interface Design for Air Traffic Control Display)

  • 고승문;명노해
    • 대한인간공학회지
    • /
    • 제25권4호
    • /
    • pp.103-113
    • /
    • 2006
  • The purpose of this study was to evaluate an effect of the new air traffic control display designed by Ecological Interface Design [EID]. The methodology of EID has not been applied to the development of the air traffic control display so far. To design a new air traffic control display by EID, We implemented Work Domain Analysis about the air traffic control domain and made the Work Domain Model that consisted of the five levels of the Abstraction Hierarchy. We extracted the Information Requirement from the completed Work Domain Model and the extracted information requirements from the model were used to design the new air traffic control display. We evaluated an effect of the new air traffic control display designed by EID. Participants for evaluating consisted of 14 active military air traffic controller of the Republic of Korea Air Force. Experiment was designed two factors within subject. Factors manipulated in the experiment included displays type to compare the existing type with the new ecological interface type and included complexity to compare the effect of the high complex situation with the effect of the low complex situation. Response time about questions with relation to air traffic collision situation, accuracy, and subjective work load were measured. The results reveled that EID type's display has a significant effect on response time, accuracy, and subjective work load and verified that EID could be applied to the air traffic control domain that is more complex and dynamic.

백화점 내 업종별 판매매장에 따른 오염물질 배출현황 평가 (Evaluation of Pollutants Emissions according to the Selling Store in Department Store)

  • 왕형석;황준석;장성진;김수민
    • 한국가구학회지
    • /
    • 제26권1호
    • /
    • pp.71-76
    • /
    • 2015
  • It is important thing that air quality affects human health. And It is more important thing that Indoor Air Quality more affects human health than Outdoor Air Quality. The cause of that is indoor air pollutants are more absorbed than outdoor air pollutants. By the way, in case of Multi-use facility for example office, department store, school etc., it has a feature that there are more people than any other buildings. therethrough, effects of Indoor Air Quality of Multi-use facility affect more people's health than Indoor Air Quality of any other buildings. However, in multi-use facility, specifically retail store, chemical treated materials are used for interior finishing, showcase finishing and product finishing because esthetic element is more added for detention of customer. Consequently, in place where demands brisk sales, possibility that indoor air is polluted by VOCs is high. This study considered retail store's Indoor Air Quality. as result of experiment, figure of department store's air pollution exceed about 5~20 times in guideline of multi-use facility's Indoor Air Quality in any kind of shop of department store (guideline : $500{\mu}g/m^3$).

부하예측 외기냉방에 의한 건물에너지 절약에 관한 연구 (A Study on Building Energy Saving using Outdoor Air Cooling by Load Prediction)

  • 김태호;유성연;김명호
    • 설비공학논문집
    • /
    • 제29권2호
    • /
    • pp.43-50
    • /
    • 2017
  • The purpose of this study is to develop a control algorithm for outdoor air cooling based on the prediction of cooling load, and to evaluate the building energy saving using outdoor air cooling. Outdoor air conditions such as temperature, humidity, and solar insolation are predicted using forecasted information provided by the meteorological agency, and the building cooling load is predicted from the obtained outdoor air conditions and building characteristics. The air flow rate induced by outdoor air is determined by considering the predicted cooling loads. To evaluate the energy saving, the benchmark building is modeled and simulated using the TRNSYS program. Energy saving by outdoor air cooling using load prediction is found to be around 10% of the total cooling coil load in all locations of Korea. As the allowable minimum indoor temperature is decreased, the total energy saving is increased and approaches close to that of the conventional enthalpy control.

CFD 기반 유체충격 해석에서 공기 압축성 효과 (Air Compressibility Effect in CFD-based Water Impact Analysis)

  • 찬후피;안형택
    • 대한조선학회논문집
    • /
    • 제48권6호
    • /
    • pp.581-591
    • /
    • 2011
  • This paper describes the air compressibility effect in the CFD simulation of water impact load prediction. In order to consider the air compressibility effect, two sets of governing equations are employed, namely the incompressible Navier-stokes equations and compressible Navier-Stokes equations that describe general compressible gas flow. In order to describe violent motion of free surface, volume-of-fluid method is utilized. The role of air compressibility is presented by the comparative study of water impact load obtained from two different air models, i.e. the compressible and incompressible air. For both cases, water is considered as incompressible media. Compressible air model shows oscillatory behavior of pressure on the solid surface that may attribute to the air-cushion effect. Incompressible air model showed no such oscillatory behavior in the pressure history. This study also showed that the CFD simulation can capture the formation of air pockets enclosed by water and solid surface, which may be the location where the air compressibility effect is dominant.

Development of Intelligent Powered Gait Orthosis for Paraplegic

  • Kang, Sung-Jae;Ryu, Jei-Cheong;Moon, In-Hyuk;Kim, Kyung-Hoon;Mun, Mu-Seung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1272-1277
    • /
    • 2005
  • In this study, we wolud be developed the fuzzy controlled PGO that controlled the flexion and the extension of each PGO's joint using the bio-signal and FSR sensor. The PGO driving system is to couple the right and left sides of the orthosis by specially designed hip joints and pelvic section. This driving system consists of the orthosis, sensor, control system. An air supply system of muscle is composed of an air compressor, 2-way solenoid valve(MAC, USA), accumulator, pressure sensor. Role of this system provide air muscle with the compressed air at hip joint constantly. According to output signal of EMG sensor and foot sensor, air muscles and assists the flexion of hip joint during PGO gait.

  • PDF

Advances In Air-Cooled Heat Exchanger Technology for Residential Air-Conditioning

  • Webb Ralph L.;Kim Nae-Hyun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제13권4호
    • /
    • pp.184-195
    • /
    • 2005
  • This paper describes the recent work on advanced technology concepts applied to air cooled heat exchangers for residential air-conditioning. The concepts include vortex generators for the air-side, micro-fin or flat tubes for the refrigerant-side. Advances in understanding of heat transfer mechanisms, predictive models are discussed.

개별공간의 자외선 살균 시스템 (UV Immune System of Personalized Space)

  • 정기범;최상곤
    • 설비공학논문집
    • /
    • 제21권1호
    • /
    • pp.63-70
    • /
    • 2009
  • The air sterilization systems are investigated experimentally in this paper. The goal is to reduce bacteria, mold and viruses in office air by using a UV sterilizer installed inside a partition panel and wall-mounted unit. These systems allow occupants to turn the system on/off and to control the incoming air speed and direction. The partition air sterilization system conditions and sterilizes the air, and then delivers the clean air into the personal task area through the partition panels, which are connected to the pressurized under-floor plenum. Room air exits through the return grills mounted on the ceiling. The wall-mounted air sterilization system sterilizes the air, and then delivers the clean air to the personal task area from the wall. In this study a full-size experimental environment is established to investigate the immunization performance of these air sterilization systems. A typical office space scale is used in this study in order to find an optimal system to achieve a sterilized healthy micro-environment. Multiple system parameters, including volume flow rate and velocity of supplied air, were regulated during the experiments. The more air contact these air sterilization systems had, the better disinfection performance. Over 90% of eradication ratios were obtained by these two air sterilization systems. The results indicate that these systems can efficiently disinfect office air contamination.