• 제목/요약/키워드: Air-to-Water Heat Pump System

검색결과 224건 처리시간 0.016초

오일 용해도를 고려한 $CO_2$ 트윈 로타리 압축기 성능해석 (Solubility Consideration in Performance Analysis of a $CO_2$ Twin Rotary Compressor)

  • 김우영;안종민;김현진;조성욱
    • 설비공학논문집
    • /
    • 제19권12호
    • /
    • pp.842-849
    • /
    • 2007
  • For a $CO_2$ two-stage twin rotary compressor used for heat pump water heater system, changes of $CO_2$ solubility in PAG oil were investigated along the gas passages from the first stage suction to final discharge. Only slight changes in solubility took place in suction chambers for both of the first and second stages, but for compression chambers, solubility variation ranged from 0.115 to 0.136, and from 0.133 to 0.182, respectively for the first and second stages. Calculation of gas flashing in parts of leakage oil flows and of oil contained in control volumes due to solubility changes was conducted and included in gas pressure calculation. For the second stage, gas flashing amounts to around $5%\sim6%$ for most leakage flows. Cooling capacity, compressor input, and COP obtained by calculation were well compared to the experimental results. Effects of operation speed on the compressor performance was also studied: as the shaft speed increased, adiabatic efficiency decreased rapidly due to increased over-compression loss.

$CO_2$ 2단 트윈 로타리 압축기 성능해석 (Performance Analysis of a $CO_2$ Two-Stage Twin Rotary Compressor)

  • 김우영;안종민;김현진;조성욱
    • 설비공학논문집
    • /
    • 제19권1호
    • /
    • pp.19-27
    • /
    • 2007
  • Analytical investigation on the performance of a two stage twin rotary compressor for $CO_2$ heat pump water heater system has been carried out. A computer simulation program was made based on analytical models for gas compression in control volumes, leakages among neighboring volumes, and dynamics of moving elements of the compressor. Calculated cooling capacity, compressor input, and COP were well compared to those of experiments over the compressor speeds tested. For the operating condition of suction pressure of 3 MPa, and discharge pressure of 9 MPa, and compressor inlet temperature of $35^{\circ}C$, the compressor efficiency was calculated to be 80.2%: volumetric, adiabatic, and mechanical efficiencies were 88.3%, 93.2%, and 92.7%, respectively. For the present compressor model, volumetric and adiabatic efficiencies of the second stage cylinder were lower by about $6{\sim}7%$ than those of the first stage mainly due to the smaller discharge port at the second stage. Parametric study on the discharge port size showed that the compressor performance could be improved by 3.5% just by increasing the discharge port diameter by 20%.

On the Safety and Performance Demonstration Tests of Prototype Gen-IV Sodium-Cooled Fast Reactor and Validation and Verification of Computational Codes

  • Kim, Jong-Bum;Jeong, Ji-Young;Lee, Tae-Ho;Kim, Sungkyun;Euh, Dong-Jin;Joo, Hyung-Kook
    • Nuclear Engineering and Technology
    • /
    • 제48권5호
    • /
    • pp.1083-1095
    • /
    • 2016
  • The design of Prototype Gen-IV Sodium-Cooled Fast Reactor (PGSFR) has been developed and the validation and verification (V&V) activities to demonstrate the system performance and safety are in progress. In this paper, the current status of test activities is described briefly and significant results are discussed. The large-scale sodium thermal-hydraulic test program, Sodium Test Loop for Safety Simulation and Assessment-1 (STELLA-1), produced satisfactory results, which were used for the computer codes V&V, and the performance test results of the model pump in sodiumshowed good agreement with those in water. The second phase of the STELLA program with the integral effect tests facility, STELLA-2, is in the detailed design stage of the design process. The sodium thermal-hydraulic experiment loop for finned-tube sodium-to-air heat exchanger performance test, the intermediate heat exchanger test facility, and the test facility for the reactor flow distribution are underway. Flow characteristics test in subchannels of a wire-wrapped rod bundle has been carried out for safety analysis in the core and the dynamic characteristic test of upper internal structure has been performed for the seismic analysis model for the PGSFR. The performance tests for control rod assemblies (CRAs) have been conducted for control rod drive mechanism driving parts and drop tests of the CRA under scram condition were performed. Finally, three types of inspection sensors under development for the safe operation of the PGSFR were explained with significant results.

Noncondensable gas's influence in waster vapor absorption accompanying interfacial disturbance into aqueous solution of LiBr

  • Dong-Ho RIE;Keun-Oh Lee
    • 한국안전학회지
    • /
    • 제7권2호
    • /
    • pp.63-70
    • /
    • 1992
  • 흡수식 열펌프에서 폭 넓게 사용되고 있는 대표적인 냉매/흡수용액은 $H_2O$ / LiBr 계이다 그러나, LiBr 수용액의 점성계수는 LiBr의 농도가 커짐에 따라 증가하기 때문에, LiBr수용액의 농용액 영역에서 물질확산계수가 감소한다. 이 결점을 보완하기 위해 흡수용액에 계면활성제를 첨가시키므로서 흡수를 촉진시키는 방식을 이용하고 있다. 계면활성제의 첨가에 의한 흡수용액의 열 및 물질이동 촉진에 관한 연구는 계면활성제 첨가농도에 의해 흡수용액의 표면상에서 게면활성제가 액적으로 존재하는 계면활성제 포화용해도 이상의 조건에서 발생하는 마랑고니대류가 효과적이다. 이 흡수촉진효과는 냉매증기의 흡수시 흡수용액표면상의 분포한 계면활성제와 흡수용액사이의 표면장력차에 기인하는 계면교한 현상에 기인한다. 그러나, 이흡수촉지효과는 냉매증기의 흡수가 일어나는 흡수기 내부의 不안정상태, 즉, 불응축성가스(공기)가 존재하지 않는 조건하에서 이루어지며, 불응축성가스가 흡수촉진저하(열 및 물질이동의 저하)에 기인하는 연구는 보고된 바 없다. 이러한 불응축성가스가 흡수기 내부에 존재할 때 계면교한의 거동 및 열 및 물질이동저하현상을 파악하기 위하여 계면활성제 농도변화(포화용해도 이상 및 이하의 두 조건)에 따른 증기흡수 실험 및 계면교한가시화 실험을 행하였다. 결과적으로 본실험을 통하여 불응축성가스가 수증기흡수에 끼치는 영향을 파악(계면교란의 악화) 첨가시의 흡수량과 不安定상태(불응축성가스가 존재시)의 증기흡수량의 비교에 의해 급격한 증기흡수저하가 不安定상태하에서 발생함으로서 불응축성가스가 흡수촉진효과(계면교한현상)을 저해시키는 결론을 얻었다.es and facts obtained by the expenence in this area, respectively. Both depth-first search and backward chaining schemes are used in reasoning process. This expert system is written in an artificial intelligence language "PROLOG", and its availability is demonstrated through the case study.e함량은 감소되었으며 sulfhydryl기가 증가됨에 따라서 disulfide groups은 감소되는 경향을 보였고 ascorbic acid는 열처리 온도뿐만 아니라 시간과도 관련이 있음을 알 수 있었다. 저온 살균유와 초고온 살균유 사이에서는 지표물질들의 함량이 다소 차이가 있음을 볼 수 있었다.담시간이 구체적으로 기술되지 않았으며, 고유한 언어를 통역하는 과정에서 의미론적 문제에 대한 고려가 부족하였다. 면접과 기록과정에서 보면 자료의 기록과정과 분류 및 분석과정이 명시되어 있지 않았다. 참여관찰과 면접방법을 사용시 이에 대한 자세한 기술이 되어 있지 않았다. 5. 연구결과의 적용 및 이에 대한 논의는 상당히 제한되어 있었는데, 수편의 연구만이 방법론 문제점과 앞으로의 연구분야에 대한 전망을 제시하였으며, 특이한 것은 어 떤 연구자도 이른 개발을 위한 적용 및 임상실무적 차원에서 간호에 대한 제언을 하지 않았다.유모델변수들은 유입-유출 자료들로부터 평가할 수 있으며, 이를 위해서 본 논문에서는 Gauss-Newton 방법을 이용한 Bard

  • PDF