• 제목/요약/키워드: Air-source heat pump system

검색결과 237건 처리시간 0.028초

열원조건 분석 통한 흡수식 히트펌프 적용 열에너지 네트워크의 에너지 절감 예측 (A Study on the Energy Reduction of a Heating Network Through the Application of an Absorption Heat Pump)

  • 나선익;이영수;백영진;이길봉
    • 설비공학논문집
    • /
    • 제29권5호
    • /
    • pp.239-248
    • /
    • 2017
  • At the $21^{st}$ Conference of the Parties (COP) of the United Nations Climate change Conference, representatives of the 195 member countries reached an agreement requiring all participating countries, including Korea, to establish proactive measures to fight climate change. Under this vision, energy network technologies are deemed as a key site of research towards meeting this goal. Herein, the headquarters of the Korea Institute of Energy Research (KIER) is a worthy site for carrying out energy network technology research insofar as it contains various heat sources. To prepare for this research, a study was conducted analyzing the heat sources at KIER based on measured data. The study also consisted of developeding simulation models to predict the amount of energy savings that could be derived by replacing an absorption chiller/heater with an absorption heat pump during winter seasons. In our simulation results, we observed a primary energy saving ratio of 65~72% based on the water temperature from the heat source of a coal power plant.

단순 선형열원 모델을 이용한 지중 유효 열전도도와 보어홀 유효 열저항 산정 (Evaluation of Ground Effective Thermal Conductivity and Borehole Effective Thermal Resistance from Simple Line-Source Model)

  • 손병후
    • 설비공학논문집
    • /
    • 제19권7호
    • /
    • pp.512-520
    • /
    • 2007
  • The design of a ground-source heat pump system includes specifications for a ground loop heat exchanger where the heat transfer rate depends on the effective thermal conductivity of the ground and the effective thermal resistance of the borehole. To evaluate these heat transfer properties, in-situ thermal response tests on four vertical test boreholes with different grouting materials were conducted by adding a monitored amount of heat to circulating water. The line-source method is applied to the temperature rise in an in-situ test and extended to also give an estimate of borehole effective thermal resistance. The effect of increasing thermal conductivity of the grouting materials from 0.818 to $1.104W/m^{\circ}C$ resulted in overall increases in effective thermal conductivity by 15.8 to 56.3% and reductions in effective thermal resistance by 13.0 to 31.1%.

온실 내 잉여 태양열을 이용한 공기열원 히트펌프 성능향상 (Performance Improvement of an Air Source Heat Pump by Storage of Surplus Solar Energy in Greenhouse)

  • 권진경;강금춘;문종필;강연구;김충길;이수장
    • 생물환경조절학회지
    • /
    • 제22권4호
    • /
    • pp.328-334
    • /
    • 2013
  • 본 연구에서는 온실 내부의 태양 잉여열과 외부의 공기열을 선택적으로 열원으로 이용함으로써 히트펌프의 성능을 향상시키고, 온실의 환기 지연을 통해 이산화탄소 시용비용을 절감할 수 있는 온실 공조시스템을 개발하고자 하였다. 본 시스템의 축열 과정은 태양 잉여열을 이용하는 내부순환모드와 외기열을 이용하는 외부순환모드가 온실 내부온도에 따라 자동으로 절환되도록 구성하였으며, 히트펌프 가동, 축열모드 절환, 난방 가동을 위한 6개의 온도값을 입력함으로써 축열과 난방이 자동으로 수행되도록 설계하였다. 단동온실을 대상으로 무환기 조건에서 기초시험을 수행한 결과, 태양 잉여열을 이용한 축열은 약 11시부터 시작되어 평균 3시간 30분 정도 유지되었으며, 주간의 온실 내부온도는 환기를 수행하지 않음에도 대부분 약 $20{\sim}28^{\circ}C$ 범위를 유지하였다. 주간 내부순환모드에서 시스템의 난방성능계수는 약 3.35로 야간 외부순환모드의 2.46 및 주간 외부순환모드의 2.67에 비해 각각 36% 및 25% 향상됨을 확인하였다. 본 시스템의 개선사항으로 태양 잉여열의 효율적 이용을 위해 축열조 관리온도를 상승시킬 수 있는 고효율 히트펌프의 적용이 필요하며, 온실의 무환기 운용에 따른 과습환경의 조성을 방지하고 태양 잉여열 수준이 높은 시기에 온실의 온도상승을 방지하기 위해 강제환기를 운전모드에 추가할 필요가 있는 것으로 판단되었다.

축열식 열원시스템 적용에 의한 전력부하 평준화의 경제성 검토 (Feasibility Study on Leveling Method of Electric Power Load by Applying Thermal Storage Air Conditioning System)

  • 이철구
    • 한국지열·수열에너지학회논문집
    • /
    • 제15권1호
    • /
    • pp.9-17
    • /
    • 2019
  • Reducing global warming potential has become important, and as one of those methods for reducing it, economic evaluation by applying ice thermal storage air conditioning system was performed. The floor area and height of the subject building was assumed $5,000m^2$ and 20 m. Absorption chillerheater system and air source heat pump system was used for comparing to the subject system, and payback period method was used to perform economic evaluation. Although the running cost of ice thermal storage system is reduced compared to two systems, the ratio is not significant compared to the increase of initial construction expenses, and payback period was calculated to be about 7.7 and 79.3 years. However, the heat storage system should be approached from the viewpoint of long term rather than the economic standard in the present standard.

에너지원별 냉방기기 표본설계 (Sample design of cooling systems for each energy source)

  • 강용태;이덕주;김의경;전호철
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.202-208
    • /
    • 2008
  • The objectives of this study are to collect the population of each cooling system for gas and electric driven systems, and propose sample design for five cooling systems; ice storage systems, system air-conditioning system, turbo system as electric driven cooling systems, and absorption system and Gas driven Heat Pump (GHP) system as gas driven cooling systems. The sample design are carried out based on types of business, capacity, installation region and year. This study proposes criterion of the sample design for cooling systems for each energy source.

  • PDF

지열원히트펌프를 활용한 도로융설시스템의 성능 평가 및 예측 (An Evaluation and Prediction of Performance of Road Snow-melting System Utilized by Ground Source Heat Pump)

  • 최덕인;황광일
    • 한국태양에너지학회 논문집
    • /
    • 제32권3호
    • /
    • pp.138-145
    • /
    • 2012
  • Because of the climate changes and the development of building technologies, the cooling loads have been increased. Among the various renewable energies, geothermal energy is known as very useful and stable energy for heating and cooling of building. This study proposes a road snow-melting system of which heat is supplied from GSHP(Ground source heat pump) in viewpoint of the initial investment and annual running performance, which is also operating as a main facility of heating and cooling for common spaces. The results of this study is as followings. From the site measurement, it is found out that the road surface temperature above the geothermal heating pipe rose up to $5^{\circ}C$, which is the design temperature of road snow-melting, after 2 hours' operation and average COP(Coefficient of performance) was estimated as 3.5. The reliability of CFD has confirmed, because the temperature difference between results of CFD analysis and site measurement is only ${\pm}0.4^{\circ}C$ and the trend of temperature variation is quite similar. CFD analysis on the effect of pavement materials clearly show that more than 2 hours is needed for snow-melting, if the road is paved by ascon or concrete. But the road paved by brick is not reached to $5^{\circ}C$ at all. To evaluate the feasibility of snow-melting system operated by a geothermal circulation which has not GSHP, the surface temperature of concrete-paved road rise up to $0^{\circ}C$ after 2 hour and 40 minutes, and it does never increase to $5^{\circ}C$. And the roads paved by ascon and brick is maintained as below $0^{\circ}C$ after 12 hours geothermal circulation.

지중열교환기의 고밀도폴리에틸렌 배관 형상에 따른 열전달 성능 특성에 대한 수치해석적 연구 (Numerical Analysis on the Heat Transfer Characteristics of HDPE Pipe with the Variation of Geometries for Ground Loop Heat Exchangers)

  • ;최종민
    • 한국지열·수열에너지학회논문집
    • /
    • 제12권4호
    • /
    • pp.33-39
    • /
    • 2016
  • A ground source heat pump (GSHP) system is recommended as a heating and cooling system to solve the pending energy problem in the field of air conditioning, because it has the highest efficiency. However, higher initial construction cost works as a barrier to the promotion and dissemination of GSHP system. In this study, numerical analysis on the characteristics of high density polyethylene (HDPE) pipe with spiral inside was executed. The heat transfer and flow characteristics of it were compared with those of a conventional smooth HDPE pipe. The heat transfer coefficient and pressure drop of the spiral HDPE pipe were higher than those of the smooth HDPE pipes at the same fluid flow rate. By decreasing the flow rate, the spiral HDPE pipe represented similar values of heat transfer coefficient and pressure drop to the smooth HDPE pipe. The lower flow rate of the spiral HDPE pipe comparing with it of the smooth HDPE pipe is estimated to reduce the length of the ground loop heat exchanger.

하천수 이용 열원시스템의 경제성 평가 (Economic Evaluation on Energy System Using River Water)

  • 이철구;김종대;임태순;최명식;방승기;함흥돈
    • 한국지열·수열에너지학회논문집
    • /
    • 제9권2호
    • /
    • pp.25-31
    • /
    • 2013
  • It has become very important for unused energy to be used for building air conditioning. Economic evaluation on energy system by using river water as a heat source, which is one of the unused energy, was carried out. The floor area of the building and the distance between heat source equipment and river was assumed $50,000m^2$ and 200 m. General heat source system using absorption chiller-heater was used for comparing to the energy saving system, and payback period method using initial cost and running cost of two systems, was used to perform economic evaluation. According to development of high capacity of water source heat pump which is appropriate for using river water, initial cost for the system has been reduced. Payback period was about 3.2 years, and this period might be shortened if nation's economic support enact.

공동주택에서 지열 냉난방 시스템 적용시 경제성 분석 (Economic Analsys of Cooling-Heating System Using Ground Source Heat in Multi Family Apartment)

  • 박용부;박종배;임해식;백성권
    • 한국지반환경공학회 논문집
    • /
    • 제8권3호
    • /
    • pp.11-18
    • /
    • 2007
  • 본 연구에서는 파급효과가 큰 공동주택에서 지열 냉난방 시스템의 경제성을 아파트 분양평형, 운전시간, 냉난방 및 급탕 설치형태별로 구분하여 초기 공사비 증가, 운전비 절감액, 초기 투자비 회수기간등을 산정하였다. 냉난방 및 급탕 운전시간이 많을수록 초기 공사비 증가액에 비해 운전비용 절감액이 커 초기 투자비 회수기간이 단축되었다. 전용면적이 클수록 투자회수 기간이 길었으며 냉난방 및 급탕 설치형태에서는 냉난방을 지열원, 급탕을 폐열회수한 경우가 초기 투자 회수기간이 가장 짧았다. 기존 시스템(패키지 에어콘, LNG 난방 및 급탕)에 비해 냉난방, 급탕을 모두 지열로 이용하는 경우, 냉난방은 지열, 급탕은 폐열을 이용하는 경우, 냉난방은 지열, 급탕은 LNG인 경우에 공사비가 $m^2$당 각각 약 72,000원, 66,900원, 62,300원 정도 증가하였다.

  • PDF