• 제목/요약/키워드: Air-side performance

검색결과 333건 처리시간 0.026초

Study of Flooding Prevention on Cathode Gas Diffusion Layer for Dynamic Load Fuel Cell

  • Choi, Dong-Won;You, Jin-Kwang;Rokhman, Fatkhur;Bakhtiar, Agung;Choi, Kwang-Hwan
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.270-273
    • /
    • 2011
  • Water management is important in proton exchange membrane fuel cell because the water balance has a significant impact on the overall fuel cell system performance. In fuel cell vehicle, the vehicle's power demand is dynamic; therefore, the dynamic water management system is required. This present study proposes a method to control the humidity of the input air in cathode side of the fuel cell vehicle. The simulation using several driving cycles shows the proposed air humidification control obtains a relatively good result. The liquid saturation level is seen constant at the target level although still there are small deviations at driving cycles which having averagely high power demands.

  • PDF

냉매의 불균일한 분배가 증발기의 성능에 미치는 영향 (Effects on Refrigerant Maldistribution on the Performance of Evaporator)

  • 김창덕;이진호
    • 설비공학논문집
    • /
    • 제16권3호
    • /
    • pp.230-240
    • /
    • 2004
  • An experimental investigation was conducted to study two-phase flow distribution in a T-type distributor of slit fin-and-tube heat exchanger using R22. A comparison was made between the predictions by previously proposed tube-by-tube method and experimental data for the heat transfer rate of evaporator. Experiments were carried out under the conditions of saturation temperature of 5$^{\circ}C$ and mass flow rate varying from 0.6 to 1.2kg/min. The inlet air has dry bulb temperature of 27$^{\circ}C$, relative humidity of 50% and air velocity varying from 0.63 to 1.71㎧. Experiment show that air velocity increased by 85.2% is need for T-type distributor with four outlet branches than that of two outlet branches under the superheat of 5$^{\circ}C$, which resulted in air-side pressure drop increase of 130% for T-type distributor with four outlet branches as compared to two outlet branches.

Study on Performance Evaluation of Oscillating Heat Pipe Heat Exchanger for Low Temperature Waste Heat Recovery

  • Bui, Ngoc-Hung;Kim, Ju-Won;Jang, In-Seung;Kang, Jeong-Kil;Kim, Jong-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제11권2호
    • /
    • pp.73-81
    • /
    • 2003
  • The performance of heat exchanger using oscillating heat pipe (OHP) for low temperature waste heat recovery was evaluated. OHP used in this study was made from low finned copper tubes connected by many turns to become the closed loop of serpentine structure. The OHP heat exchanger was formed into shell and tube type. R-22 and R-141b were used as the working fluids of OHP with a fill ratio of 40 vol.%. Water was used as the working fluid of shell side. As the experimental parameters, the inlet temperature difference between heating and cooling water and the mass velocity of water were changed. The mass velocity of water was changed from 30 kg/$m^2$s to 92 kg/$m^2$s. The experimental results showed that the heat recovery rate linearly increased as the mass velocity and the inlet temperature difference of water increased. Finally, the performance of OHP heat exchanger was evaluated by $\varepsilon$-NTU method. It was found that the effectiveness would be 80% if NTU were about 1.5.

채널 형상에 따른 마이크로채널 PCHE의 열전달 및 압력강하 특성 (The Heat Transfer and Pressure Drop Characteristics on Microchannel PCHE with various Configurations)

  • 김윤호;문정은;이규정
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.215-220
    • /
    • 2008
  • A microchannel PCHE is manufactured by the two technologies of micro photo-etching and diffusion bonding. In this paper, heat transfer and pressure drop characteristics by applying various configuration for the flow channel in the microchannel PCHE is experimentally investigated. The flow channel configurations are designed three types such as straight, wavy and offset strip channels. The performance experiment of each configuration is performed for Reynolds numbers in ranges of $100{\sim}700$ under various flow conditions for the hot side and the Reynolds number of cold side is fixed at 350. The inlet temperatures of the hot side and cold side are conducted as $40^{\circ}C$ and $20^{\circ}C$, respectively. The heat transfer performance of wavy channel, which was similar to that of offset strip channel, was much higher than that of straight channel. The effectiveness of wavy channel and offset strip channel was evaluated as about $0.5{\sim}0.9$. The pressure drop of wavy channel was highest among configurations and that of offset strip channel was lower than that of straight channel because the round curved surface of each strip edge was reduced the pressure loss.

  • PDF

단상유동 조건에서 용접형 판형 열교환기의 열전달 및 압력강하 특성연구 (Heat Transfer and Pressure Drop Characteristics of Brazed Plate Heat Exchangers with Single-Phase Flow)

  • 김만배;박창용
    • 설비공학논문집
    • /
    • 제26권11호
    • /
    • pp.522-528
    • /
    • 2014
  • This experimental study measured and analyzed the heat transfer and pressure drop performance of brazed plate heat exchangers. Heat exchangers with different plate numbers of 10, 20, 30, and 40 were used for measurement, and their plate pattern was identical. The experiment was performed with distilled water, by changing the hot-side flow rate, with the cold-side flow rate fixed. The experimental results were compared with the calculated values by correlations based on gasketed plate heat exchangers, and showed that the heat transfer performance and pressure drop of brazed plated heat exchangers were higher than those of gasketed plate heat exchangers. From the variation of the friction factor, it could be inferred that in the flow channels of brazed plate heat exchangers, turbulent flow occurred at Reynolds numbers higher than 500. A new correlation to predict the Nusselt number was developed, and its absolute average deviation was 2.62%, compared with the values from the experimental data.

지그재그채널 PCHE의 각도에 따른 열전달 및 압력강하특성 (Heat Transfer and Pressure Drop Characteristics in Zigzag Channel Angles of Printed Circuit Heat Exchangers)

  • 권오경;최미진;최영종
    • 설비공학논문집
    • /
    • 제21권9호
    • /
    • pp.475-482
    • /
    • 2009
  • The objectives of this paper are to study the characteristics of heat transfer and pressure drop of the zigzag channel PCHE using diffusion bonding technology by numerical analysis. PCHE of five types are designed, which are zigzag channel angle 180$^{\circ}$, 160$^{\circ}$, 140$^{\circ}$, 120$^{\circ}$ and 100$^{\circ}$. The zigzag PCHE was numerically investigated for Reynolds number in a range of 150$\sim$800. The temperatures of the hot side were performed at 80$^{\circ}$ while that of the cold side was conducted at 20$^{\circ}C$. The results show that the performance of heat transfer rate for zigzag channel 100$^{\circ}$ increases about 11.5% compared to that of zigzag channel 180$^{\circ}$. On the other hand, the performance of pressure drop for zigzag channel 100$^{\circ}$ is remarkably higher than that of zigzag channel 180$^{\circ}$, about 2.4 times.

용접식 판형 열교환기의 성능에 관한 실험적 연구 (An Experimental Study on the Performance of a Brazed Plate Heat Exchanger)

  • 김종하;권오경;윤재호;이창식
    • 설비공학논문집
    • /
    • 제14권1호
    • /
    • pp.83-90
    • /
    • 2002
  • An experimental study on the performance evaluation of a brazed plate heat exchanger with 10USRT of normal cooling capacity has been carried out. In the present study, a brazed plate heat exchanger was tested at a chevron angle $25^{\circ}$with refrigerant R-22. Refrigerant mass flux was ranged from 23 to 58 kg/$m^2$s in condensation, and from 22 to 53 kg/$m^2$s in evaporation. The heat transfer coefficients and pressure drops are increased as the mass flux increases. The water side pressure drop is increased as the cooling water flow rate and chilled water flow rate increase, while mass flux has little effect. It is also shown that the system performance can be improved by enlarging condensation heat transfer area.

보조 흡입구가 장착된 왕복동 압축기의 성능 분석 (Performance of a Reciprocating Compressor Equipped with Auxiliary Port)

  • 이용호;김현진
    • 설비공학논문집
    • /
    • 제20권10호
    • /
    • pp.637-644
    • /
    • 2008
  • Auxiliary port which had been known to be used to reduce the expansion loss of a refrigeration system was applied to a R134a reciprocating compressor in a household refrigerator cycle with an intention of improving the compressor performance. Effects of the auxiliary port on the compressor performance was investigated by a computer simulation program. When a simple hole was made on the side wall of the cylinder as an auxiliary port and surrounding gas inside the compressor shell was assumed to be drawn into the cylinder through the hole, maximum COP improvement of 1.66% was obtained. With auxiliary port equipped with a plate type of check valve, maximum COP was raised to be 1.99%. COP improvement was more distinctive with decreasing the discharge pressure; COP improvement was 5% with discharge pressure of 7 bar.

유도공기 및 에어커튼을 이용한 주방 레인지후드 성능 개선에 관한 수치모사 (A Numerical Study on the Performance Improvement of Kitchen Range Hood by Air Induction and Air Curtain)

  • 손덕영;임지홍;최윤호;박재훈
    • 설비공학논문집
    • /
    • 제19권4호
    • /
    • pp.321-327
    • /
    • 2007
  • In an apartment house that is generally air-tight and well insulated, the combustion gas from cooking devices is the major source of air pollution in the kitchen. It spreads throughout the house affecting the overall Indoor all quality. In this study, the performance of the kitchen range hood which employs air induction and air curtain was investigated by numerical simulation. The results are compared with that of two other kitchen range hoods which are in general use. The two general types of range hoods considered in the present calculations are box and plate type range hoods. The former has a large capture space between the filter and suction duct, while the latter has little. It was found that the capture efficiency of the kitchen range hood with air induction and air curtain Is higher than that of the general types of range hoods by 20% approximately The reason may be because the air induction and the air curtain block the air stream escaping from the front and the side part of range hoods effectively and because an additional fan for air induction and air curtain increases suction flow rates.

2열 외부가압 공기 저어널 베어링에서 급기구 위치에 따른 부하지지 특성에 관한 연구 (A Study on the Loading Capacity According to the Source Positions in Externally Pressurized Air Journal Bearing with Two Row Sources)

  • 이종열;성승학;이득우
    • Tribology and Lubricants
    • /
    • 제17권5호
    • /
    • pp.365-372
    • /
    • 2001
  • This paper has been presented the hydrodynamic effect by the journal speed, eccentricity and source positions in order to overcome the defects of air bearing such as low stiffness and damping coefficient. Choosing the two row source position of air bearing is different from existed investigations in the side of pressure distribution of air film because of the high speed of journal and the wedge effects by the eccentricity. These optimal chooses of the two row source positions enable us to improve the performance of the film reaction force and loading force as making the high speed spindle. In this paper, The pressure behavior in theory of air film according to the eccentricity of journal and the source positions analyzed. The results of investigated characteristics may be applied to precision devices like ultra-precision grinding machine and ultra high speed milling.