• 제목/요약/키워드: Air-pressure control

검색결과 750건 처리시간 0.026초

변풍량 공조시스템의 요구외기량 확보를 위한 제어방식 (Control Methods of the VAV Air Handling Unit for the Required Outdoor Air Demand)

  • 한도영;주영덕;김진;이준호
    • 설비공학논문집
    • /
    • 제15권3호
    • /
    • pp.203-209
    • /
    • 2003
  • Control algorithms of an air handling unit by using the mixing box plenum pressures were developed and verified by experiments. Control algorithms developed for this study were the setpoint algorithms for the outdoor damper position, the outdoor/fixed plenum pressure, and the return/exhaust plenum pressure. The outdoor/fixed plenum pressure setpoint was used to control the bypass damper position, and the return/exhaust plenum pressure setpoint was used to control the return fan speed. Experimental results showed the good control of the required outdoor air demand. Therefore, setpoint algorithms developed for this study may effectively be applied for the control of the VAV air handling unit.

Air dome inner pressure control system

  • Miki, Norihisa
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1989년도 한국자동제어학술회의논문집; Seoul, Korea; 27-28 Oct. 1989
    • /
    • pp.727-730
    • /
    • 1989
  • Tokyo dome is Japan's first air dome. The roof of the dome is supported by air pressure. The centralized control system (YOKOGAWA's DCS : CENTUM and YEWPACK) is applied to automatically regurate the air pressure. The control system acquires signals from sensors positioned throughout the stadium and operate 36 fans to blow air into the dome. Great emphasis is placed on the reliability and safety of the system.

  • PDF

인체계측 모델을 이용한 욕창방지용 공기셀 매트리스의 개발 (Development of Air-cell Mattress for Preventing Pressure Ulcer Using Anthropometric Model)

  • 강성재;김규석;홍정화;류제청;김경훈;문무성;문인혁
    • 제어로봇시스템학회논문지
    • /
    • 제11권7호
    • /
    • pp.578-586
    • /
    • 2005
  • Air mattress is now used widely to prevent the pressure ulcer by reducing the localized pressure peaks. The pressure control method based on the anthrophometric model of an air-cell mattress developed in this study is presented. The air-cell mattress has 18 cylindrical air cells made of porous material allowing air leakage. Even though the air leakage can contribute to reducing the development of pressure ulcer by lowering the pressure peak, temperature and humidity, the air pressure changes with time and the desired air-cell pressure has to be determined as an optimal value for each user. To select the desired air-cell pressure, we first divide the parts of the body into four sections such as head, trunk, hip, and leg. Then, the pressure of each section grouped with air-cells is calculated from the weight of each part estimated from the individual height and body weight. Air supply system for the air-cell mattress is implemented by using four electronic solenoid valves and an air compressor, and it is driven by a real-time microcontroller. We experimented with five subjects of the contact pressure on skin. The experimental results show that the proposed air-cell mattress is effective for the prevention of the pressure ulcer.

저압 에어포그 시스템을 설치한 온실의 냉방효율 (Cooling Efficiency of Low Pressure Compressed Air Fogging System in Naturally Ventilated Greenhouses)

  • 남상운;김영식;성인모;고기혁
    • 한국농공학회논문집
    • /
    • 제54권5호
    • /
    • pp.49-55
    • /
    • 2012
  • In order to derive the efficient utilization of low pressure compressed air fogging system, cooling efficiencies with control types were analyzed through cooling experiments in tomato greenhouses. The control types were set up with temperature control, humidity control, temperature and humidity control, and time control. It showed that the cooling effects were 0.7 to $3.3^{\circ}C$ on average and maximum of 4.3 to $7.0^{\circ}C$, the humidification effects were 3.5 to 13.5 % on average and maximum of 14.3 to 24.4 %. Both the cooling and humidification effect were the highest in the time control method. The cooling efficiency of the air fogging system was not high with 8.3 to 27.3 % on average. However, the cooling efficiency of 24.6 to 27.3 % which appears from the time control is similar to the cooling efficiency of high pressure fogging system experimented in Japan. The air fogging system is operated by low pressure, but its efficiency is similar to high pressure. We think because it uses compressed air. From this point of view, we suggest that the air fogging system can get the cooling efficiency of similar levels to that of high pressure fogging system and it will have an advantage from clogging problem of nozzle etc.

A Novel Air-cell Mattress Based on Approximate Anthropometric Model for Preventing Pressure Ulcer

  • Moon, In-Hyuk;Kang, Sung-Jae;Kim, Gyu-Seok;Mun, Mu-Seong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1278-1282
    • /
    • 2005
  • Air mattress is now used widely to prevent the pressure ulcer by reducing the localized pressure peaks. In this paper an air-cell mattress and its pressure control method based on an approximate anthropometric model are presented. The air-cell mattress has eighteen cylindrical air cells made of porous material allowing air leakage to contribute in reducing the development of pressure ulcer by lowering the pressure peak, temperature and humidity. To determine an optimal air-cell pressure appropriate for each user, we divide the parts of the body into four sections such as head, trunk, hip, and leg. Then, the pressure of each section is independently calculated from the weight of each part based on the individual body height and weight and the approximate anthropometric model. Air supply system for the air-cell mattress is implemented by using four electronic solenoid valves and an air compressor, and it is driven by a real-time micro-controller. The experimental results with seven subjects shows that the proposed air-cell mattress is effective for the prevention of the pressure ulcer.

  • PDF

열전달 특성을 고려한 공기압 압력제어계의 감압제어특성 해석 (Analysis of Decompression Control Characteristics of Pneumatic Pressure Control System Considering Heat Transfer Characteristics)

  • 장지성
    • 동력기계공학회지
    • /
    • 제10권1호
    • /
    • pp.90-95
    • /
    • 2006
  • Pneumatic control systems have been mainly used as a high speed operating system. Therefore, state change of air in a control volume was assumed to be adiabatic change and, pneumatic control systems have been analyzed by using this assumption. Especially, when absolute value of pressure change in the control volume is small, there is a tendency to neglect effect of temperature change on pneumatic control system because temperature change owing to pressure change is small. In this study, an effect of temperature change of air on the decompression control process was analyzed by considering change of mass flow rate, and heat transfer characteristics between air in the chamber and the chamber wall. As a result, this study could confirm that a slight temperature change of the air in the pneumatic pressure control system can influence on the dynamic characteristics of pressure response, and pressure control performance.

  • PDF

제어밸브의 유량특성에 따른 에어스프링의 성능 변화 (Effect of Control Valve Flow Rates Characteristics on the Performance of an Air Spring)

  • 한승훈;장지성;지상원
    • 드라이브 ㆍ 컨트롤
    • /
    • 제13권3호
    • /
    • pp.8-14
    • /
    • 2016
  • This study describes the effect of the critical pressure ratio of a control valve on the performance of an air spring system composed of an air spring, auxiliary chamber, control valve and mass in order to suggest a more efficient design for an air spring system. The critical pressure ratio of the control valve is assumed to have a fixed value, but the critical pressure ratio of the control valve is known to have various values between 0.05 and 0.6, and the effect of the variation of the critical pressure ratio on the performance of the air spring system has not yet been reported. The analysis derives nonlinear and linear governing equations of the air spring system, including the critical pressure ratio of the control valve. This simulation study is presented to show that the impedance and transmissibility characteristics of the air spring system change due to variations in the critical pressure ratio of the control valve as well as its sonic conductance. As a result, the critical pressure ratio of the control valve should be maintained as large as possible to improve the vibration isolation characteristics of the air spring system.

가변 주파수 전류 제어에 의한 다이어프램의 압력제어 (Air-pressure Control of Diaphragm using Variable Frequency Current Control)

  • 임근민;이동희
    • 전력전자학회논문지
    • /
    • 제16권3호
    • /
    • pp.258-265
    • /
    • 2011
  • 본 논문은 다이어프램의 공기압력을 제어하기 위한 가변 주파수 전류 제어기를 제안한다. 제안된 제어기는 기존의 다이어프램의 공기압력을 제어하는 방법과는 달리 단상 인버터를 이용하여 상 전류와 주파수를 제어한다. 한 상의 전류는 다이어프램의 지령 공기 압력을 추종하도록 조절되고, 전류 주파수는 기계적인 진동을 줄이기 위해 변화한다. 일정한 공기압력으로 부드럽게 변화하기 위해서 전류 주파수는 전류 제어기에서 제어전압에 따라 제어되며, 이 때의 상전류가 일정한 공기압력에 만족하게 되면 전류주파수는 다이어프램의 진동을 줄이기 위해 증가된다. 제어 전압에 의한 상 전류가 지령값보다 높게 되면 전류 주파수는 공기압력을 추종하기 위해 감소된다. 제안된 제어방식은 상용 다이어프램을 이용한 실험을 통해 확인하였다.

구개열 환자에서의 구강인두압력 및 공기유량에 관한 음성학적 특징 (CHARACTERISTICS OF OROPHARYNGEAL AIR PRESSURE, AIRFLOW IN CLEFT PALATE PATIENTS)

  • 백진아
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제28권1호
    • /
    • pp.13-20
    • /
    • 2006
  • The articulation disorders associated with velopharyngeal insufficiency (VPI) in cleft palate patients are interested to clinicians particularly. The purpose of this study was to investigate mainly the oropharyngeal air pressure and overall air flow in cleft palate patients. The pressure-measuring catheter was positioned at the midportion of the oropharyngeal cavity with a facial mask. Test words were composed of 9 meaningless polysyllabic words and 17 meaningful words. Aerophone II and Nasometer II were used to measure peak air pressure, mean air pressure, maximum flow rate, volume, phonatory flow rate, nasalance. The data shows that airflow of the cleft palate patient group were higher than those of the control group. Intraoral air pressure of the cleft palate patient group was lower than those of the control group. The first vowel formant and first Bandwidths of the cleft palate patient group were higher than those of the control group.

초음속 지상추진시험설비의 공기 혼합시스템 설계 및 제작 (Design and Manufacture of the air mixing system for supersonic ground test facility)

  • 이양지;강상훈;양수석
    • 항공우주기술
    • /
    • 제7권1호
    • /
    • pp.40-48
    • /
    • 2008
  • 공기 혼합시스템은 초음속 지상추진시험설비의 축열식 가열기로부터 공급되는 $1000^{\circ}C$, 3.5MPa의 공기와 고압공기 공급원으로부터 공급되는 상온, 동일 압력의 공기를 혼합시켜서 시험부로 공급하기 위한 설비로 32MPa로 압축되어 있는 고압공기 공급원을 3.5MPa로 감압하는 고압/저온 유동제어부, 축열식 가열기의 고온밸브에서부터 공기 혼합기로 고온의 공기를 공급하기 위한 고온 배관, 축열식 가열기로부터 공급되는 고온 유동과 고압공기 공급원으로부터 공급되는 상온 유동을 혼합하기 위한 공기 혼합기로 구성된다. 공기 혼합 시스템을 통하여 완전히 혼합된 공기의 유량은 25kg/s, 온도는 약 $400^{\circ}C$로 이를 통하여 초음속 지상추진시험설비의 구동 영역을 저 마하수, 저 고도 영역까지 확장할 수 있다.

  • PDF