• 제목/요약/키워드: Air-heated solar collector

검색결과 27건 처리시간 0.018초

태양열이용 하이브리드 난방 열펌프시스템 (The hybrid heat pump with solar energy for heating)

  • 김지영;고광수;강병찬;박윤철
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.173-178
    • /
    • 2005
  • Recently. we interested in renewable energy due to cost increase of the crude oil, etc. In this study solar assisted hybrid heat pump system that uses the solar heat and air as heat source analyzed by experimentally.'rho system could runs at dual mode. One is thermal storage mode of solar energy at day time and the other is heat pump mode with low temperature air as heat source at night time. In case of setting temperature over the limited range. high temperature water heated at the solar energy collecting tubes supplied to the storage tank. As results. it is founded that the heat pump performance Is higher than general heat pump which using the only air as a heat source. The developed system could be used as main healing equipment for the panel heating for the residential house.

  • PDF

태양열(太陽熱)을 이용(利用)한 식품건조(食品乾燥)에서 Silica Gel의 활용효과(活用效果) (Effect of Silica Gel on Food Dehydration of Onion by Solar Energy)

  • 전병선;윤한교;장규섭
    • 농업과학연구
    • /
    • 제10권1호
    • /
    • pp.156-165
    • /
    • 1983
  • 태양열(太陽熱)을 이용(利用)한 silica gel의 활용(活用)에 대(對)한 기초자료(基礎資料)를 얻고자, silica gel을 이용(利用)한 양파의 건조특성(乾燥特性)과, 공기(空氣)의 제습효과(除濕效果)를 구명(究明)하고, 건조제(乾燥劑)로서의 재사용(再使用)을 위(爲)하여 실험(實驗)한바, 그 결과(結果)를 요약(要約)하면 다음과 같다. 1. 외기온도(外氣溫度) $30^{\circ}C$, 상대습도(相對濕度) 55% 내외(內外)에서 포화(飽和)silica gel을 수분함량(水分含量) 8%까지 재생(再生)시키는데 14시간(時間) 소요(所要)되었다. 2. 집열기(集熱器)를 재순환(再循環)시켜 건조(乾燥)한 결과(結果), 노천건조(露天乾燥)보다 1/2정도(程度) 시간(時間)이 단축(短縮)되었다. 3. 실험기간중(實驗期間中) 집열기(集熱器)의 평균효율(平均效率)은 25%였다. 4. 건조실(乾燥室)을 이용(利用)한 송풍건조시(送風乾燥時), 갈변도(褐變度)가 1/2로 감소(減少)되었다.

  • PDF

RSM 기법을 애용한 태양열 집열판 재생기의 운전 조건 최적화 (Optimum Operating Condition of Air Heating Solar Collector Regenerator Using RSM Technique)

  • 정재호
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2004년도 춘계학술대회
    • /
    • pp.89-91
    • /
    • 2004
  • This study examines a regeneration process using hot air heated by solar radiation to recover absorption potential by evaporating moisture in liquid desiccant. More specifically, this study is aimed at finding the optimum operating condition of the regenerator by utilizing a well-established statistical tool, so-called design of experiment, and optimization techniques. It is demonstrated that an optimization model to find the optimum operating condition can be obtained using the functional relationship between regeneration rate and affecting factors which is approximated on the basis experimental results.

  • PDF

농산물(農産物) 건조(乾燥) 및 저장(貯藏)을 위(爲)한 태양열(太陽熱) 저장고(貯藏庫)의 개발(開發)에 관(關)한 연구(硏究) (Development of Solar Warehouse for Drying and Storing the Agricultural Products)

  • 김만수;장규섭;김성래;전병선
    • 농업과학연구
    • /
    • 제9권1호
    • /
    • pp.357-370
    • /
    • 1982
  • 태양열(太陽熱)을 이용(利用)한 곡물(穀物)의 건조(乾燥)와 저장(貯藏)을 겸할 수 있는 농가용(農家用) 태양열(太陽熱) 저장고(貯藏庫)의 개발(開發)에 필요(必要)한 기초자료(基礎資料)를 얻기 위(爲)하여 구조(構造)가 간단(簡單)하고 가격(價格)이 저렴한 콘크리트 벽체의 저장고(貯藏庫)와 그 지붕을 대신(代身)한 태양열집열기(太陽熱集熱器)를 설계(設計) 제작(製作)하여 집열기(集熱器)의 성능(性能)을 실험(實驗)에 의(依)하여 구(求)하였으며 집열기(集熱器)에서 가열(加熱)된 공기(空氣)와 상온통풍(常溫通風)에 의(依)한 벼의 건조특성(乾操特性)을 비교(比較) 분석(分析)하였다. 건조(乾操)된 곡물(穀物)의 저장시(貯藏時)에 그 온도(溫度)를 예측(豫測)할 수 있는 simulation model을 개발(開發)하여 그 적합성(適合性)을 검정(檢定)하고 저장곡물(貯藏殺物)의 각(各) 부위(部位)에 대(對)한 온도(溫度)의 변화(變化)를 분석(分析)한 결과(結果)들을 요약(要約)하면 다음과 같다. 1. 본(本) 실험(實驗)에 설계(設計) 제작(製作)된 태양열집열기(太陽熱集熱器)의 효율(效率)은 평균(平均) 26%였으며 총열전달계수(總熱傳達係數)는 약(約) $25kJ/hr.m^2\;^{\circ}K$였다. 2. 태양열(太陽熱)을 이용(利用)한 건조(乾燥)에서는 공시(供試)벼의 함수율(含水率) 23.5%에서 15.0%까지 건조(乾燥)시키는데 7일(日)이 소요(所要)되었으며 상온통풍건조(常溫通風乾燥)에서는 함수율(含水率) 20.0%에서 15.5%까지 건조(乾燥)시키는데 12일(日)이 소요(所要)되었다. 3. 건조소요시간(乾燥所要時間)은 태양열(太陽熱)을 이용(利用)한 건조(乾燥)가 배(倍) 정도(程度) 빠르나 하층부(下層部)의 곡물(穀物)의 과건현상(過乾現象)의 방지책(防止策)이 철저히 구명(究明)되어야 할 것이다. 4. 저장곡물(貯藏殺物)의 온도(溫度)를 예측(豫測)할 수 있는 simulation model을 finite difference method에 의(依)해 개발(開發)하였으며 검정(檢定) 결과(結果) 실측치(實測値)와 잘 일치(一致)되었다. 5. 저장곡물(貯藏殺物)의 온도(溫度) 변화(變化)는 벽체와 접촉(接觸)하고 있는 부위(部位)에서 컸으며 곡물(穀物)의 손상(損傷)도 이곳에서 심(甚)할 것으로 사료(思料)된다.

  • PDF

TAP을 적용한 내단열과 외단열구조의 열성능 평가에 관한 연구 (A Study on Thermal Performance Evaluation with TAP (Thermosyphoning Air Panel) in Inside and Outside Insulated Constructions)

  • 이경회;유호천;홍영우;전채휘
    • 태양에너지
    • /
    • 제7권1호
    • /
    • pp.23-29
    • /
    • 1987
  • TAP system, a kind of natural convective space heating collector, has a good heat loss by night. The aim of this paper is to induce and to study an hourly heat flow theory by response factors analysis with TAP in inside and outside insulated construction, to compare and evaluate on thermal performance an hourly natural temperature, heated room temperature and heating load in aboved-mention constructions with computer simulation. The results of the study can be summarized as follows. According that there is no TAP and with TAP, it is inside insulated construction and outside insulated construction, daily natural range of temperature each shows $12.5^{\circ}C$ and $16.7^{\circ}C$, $2.7^{\circ}C$ and $3.7^{\circ}C$, daily heated range of temperature with noramal control heating system each shows $6.6^{\circ}C$ and $12.1^{\circ}C$, $1.7^{\circ}C$ and $3.1^{\circ}C$, heating hours each show 10 hr and 7 hr, 9 hr and 4 hr and heating energy saving percentage in january 123% and 79%, 100% and 40%. Therefore, energy saving percentage shows that outside insulated construction saves about 54% in comparision with inside insulated construction.

  • PDF

태양에너지를 이용한 곡물건조시스템의 시뮬레이션에 관한 연구 (Simulation of Drying Grain with Solar-Heated Air)

  • 금동혁;김용운
    • Journal of Biosystems Engineering
    • /
    • 제4권2호
    • /
    • pp.65-83
    • /
    • 1979
  • Low-temperature drying systems have been extensively used for drying cereal grain such as shelled corn and wheat. Since the 1973 energy crisis, many researches have been conducted to apply solar energy as supplemental heat to natural air drying systems. However, little research on rough rice drying has been done in this area, especially very little in Korea. In designing a solar drying system, quality loss, airflow requirements, temperature rise of drying air, fan power and energy requirements should be throughly studied. The factors affecting solar drying systems are airflow rate, initial moisture content, the amount of heat added to drying air, fan operation method and the weather conditions. The major objectives of this study were to analyze the effects of the performance factors and determine design parameters such as airflow requirements, optimum bed depth, optimum temperature rise of drying air, fan operation method and collector size. Three hourly observations based on the 4-year weather data in Chuncheon area were used to simulate rough rice drying. The results can be summarized as follows: 1. The results of the statistical analysis indicated that the experimental and predicted values of the temperature rise of the air passing through the collector agreed well. 2. Equilibrium moisture content was affected a little by airflow rate, but affected mainly by the amount of heat added, to drying air. Equilibrium moisture content ranged from 12.2 to 13.2 percent wet basis for the continuous fan operation, from 10.4 to 11.7 percent wet basis for the intermittent fan operation respectively, in range of 1. 6 to 5. 9 degrees Centigrade average temperature rise of drying air. 3. Average moisture content when top layer was dried to 15 percent wet basis ranged from 13.1 to 13.9 percent wet basis for the continuous fan operation, from 11.9 to 13.4 percent wet basis for the intermittent fan operation respectively, in the range of 1.6 to 5.9 degrees Centigrade average temperature rise of drying air and 18 to 24 percent wet basis initial moisture content. The results indicated that grain was overdried with the intermittent fan operation in any range of temperature rise of drying air. Therefore, the continuous fan operation is usually more effective than the intermittent fan operation considering the overdrying. 4. For the continuous fan operation, the average temperature rise of drying air may be limited to 2.2 to 3. 3 degrees Centigrade considering safe storage moisture level of 13.5 to 14 perceut wet basis. 5. Required drying time decrease ranged from 40 to 50 percent each time the airflow rate was doubled and from 3.9 to 4.3 percent approximately for each one degrees Centigrade in average temperature rise of drying air regardless of the fan operation methods. Therefore, the average temperature rise of drying air had a little effect on required drying time. 6. Required drying time increase ranged from 18 to 30 percent approximately for each 2 percent increase in initial moisture content regardless of the fan operation methods, in the range of 18 to 24 percent moisture. 7. The intermittent fan operation showed about 36 to 42 percent decrease in required drying time as compared with the continuous fan operation. 8. Drymatter loss decrease ranged from 34 to 46 percent each time the airflow rate was doubled and from 2 to 3 percent approximately for each one degrees Centigrade in average temperature rise of drying air, regardless of the fan operation methods. Therefore, the average temperature rise of drying air had a little effect on drymatter loss. 9. Drymatter loss increase ranged from 50 to 78 percent approximately for each 2 percent increase in initial moisture content, in the range of 18 to 24 percent moisture. 10. The intermittent fan operation: showed about 40 to 50 percent increase in drymatter loss as compared with the continuous fan operation and the increasing rate was higher at high level of initial moisture and average temperature rise. 11. Year-to-year weather conditions had a little effect on required drying time and drymatter loss. 12. The equations for estimating time required to dry top layer to 16 and 1536 wet basis and drymatter loss were derived as functions of the performance factors. by the least square method. 13. Minimum airflow rates based on 0.5 percent drymatter loss were estimated. Minimum airflow rates for the intermittent fan operation were approximately 1.5 to 1.8 times as much as compared with the continuous fan operation, but a few differences among year-to-year. 14. Required fan horsepower and energy for the intermittent fan operation were 3. 7 and 1. 5 times respectively as much as compared with the continuous fan operation. 15. The continuous fan operation may be more effective than the intermittent fan operation considering overdrying, fan horsepower requirements, and energy use. 16. A method for estimating the required collection area of flat-plate solar collector using average temperature rise and airflow rate was presented.

  • PDF

태양에너지를 이용한 곡물건조시스템의 시뮬레이션에 관한 연구 (Simulation of Drying Grain with Solar-Heated Air)

  • 금동혁
    • Journal of Biosystems Engineering
    • /
    • 제4권2호
    • /
    • pp.64-64
    • /
    • 1979
  • Low-temperature drying systems have been extensively used for drying cereal grain such as shelled corn and wheat. Since the 1973 energy crisis, many researches have been conducted to apply solar energy as supplemental heat to natural air drying systems. However, little research on rough rice drying has been done in this area, especially very little in Korea. In designing a solar drying system, quality loss, airflow requirements, temperature rise of drying air, fan power and energy requirements should be throughly studied. The factors affecting solar drying systems are airflow rate, initial moisture content, the amount of heat added to drying air, fan operation method and the weather conditions. The major objectives of this study were to analyze the effects of the performance factors and determine design parameters such as airflow requirements, optimum bed depth, optimum temperature rise of drying air, fan operation method and collector size. Three hourly observations based on the 4-year weather data in Chuncheon area were used to simulate rough rice drying. The results can be summarized as follows: 1. The results of the statistical analysis indicated that the experimental and predicted values of the temperature rise of the air passing through the collector agreed well.2. Equilibrium moisture content was affected a little by airflow rate, but affected mainly by the amount of heat added, to drying air. Equilibrium moisture content ranged from 12.2 to 13.2 percent wet basis for the continuous fan operation, from 10.4 to 11.7 percent wet basis for the intermittent fan operation respectively, in range of 1. 6 to 5. 9 degrees Centigrade average temperature rise of drying air.3. Average moisture content when top layer was dried to 15 percent wet basis ranged from 13.1 to 13.9 percent wet basis for the continuous fan operation, from 11.9 to 13.4 percent wet basis for the intermittent fan operation respectively, in the range of 1.6 to 5.9 degrees Centigrade average temperature rise of drying air and 18 to 24 percent wet basis initial moisture content. The results indicated that grain was overdried with the intermittent fan operation in any range of temperature rise of drying air. Therefore, the continuous fan operation is usually more effective than the intermittent fan operation considering the overdrying.4. For the continuous fan operation, the average temperature rise of drying air may be limited to 2.2 to 3. 3 degrees Centigrade considering safe storage moisture level of 13.5 to 14 perceut wet basis.5. Required drying time decrease ranged from 40 to 50 percent each time the airflow rate was doubled and from 3.9 to 4.3 percent approximately for each one degrees Centigrade in average temperature rise of drying air regardless of the fan operation methods. Therefore, the average temperature rise of drying air had a little effect on required drying time.6. Required drying time increase ranged from 18 to 30 percent approximately for each 2 percent increase in initial moisture content regardless of the fan operation methods, in the range of 18 to 24 percent moisture.7. The intermittent fan operation showed about 36 to 42 percent decrease in required drying time as compared with the continuous fan operation.8. Drymatter loss decrease ranged from 34 to 46 percent each time the airflow rate was doubled and from 2 to 3 percent approximately for each one degrees Centigrade in average temperature rise of drying air, regardless of the fan operation methods. Therefore, the average temperature rise of drying air had a little effect on drymatter loss. 9. Drymatter loss increase ranged from 50 to 78 percent approximately for each 2 percent increase in initial moisture content, in the range of 18 to 24 percent moisture. 10. The intermittent fan operation: showed about 40 to 50 percent increase in drymatter loss as compared with the continuous fan operation and the increasing rate was higher at high level of initial moisture and average temperature rise.11. Year-to-year weather conditions had a little effect on required drying time and drymatter loss.12. The equations for estimating time required to dry top layer to 16 and 1536 wet basis and drymatter loss were derived as functions of the performance factors. by the least square method.13. Minimum airflow rates based on 0.5 percent drymatter loss were estimated.Minimum airflow rates for the intermittent fan operation were approximately 1.5 to 1.8 times as much as compared with the continuous fan operation, but a few differences among year-to-year.14. Required fan horsepower and energy for the intermittent fan operation were3. 7 and 1. 5 times respectively as much as compared with the continuous fan operation.15. The continuous fan operation may be more effective than the intermittent fan operation considering overdrying, fan horsepower requirements, and energy use.16. A method for estimating the required collection area of flat-plate solar collector using average temperature rise and airflow rate was presented.