• 제목/요약/키워드: Air-gapped CT

검색결과 3건 처리시간 0.026초

공극 변류기의 2차 전류 보상 (Compensation for the Secondary Current of an Air-gapped Current Transformer)

  • 강용철;정태영;장성일;김용균;박지연
    • 전기학회논문지
    • /
    • 제57권2호
    • /
    • pp.149-154
    • /
    • 2008
  • An air-gapped current transformer(CT) has been used to reduce a remanent flux in the core, particularly in the case of auto-reclosure. However, it causes larger transient, ratio and phase errors than the iron-cored CT because of the small magnetizing inductance. This paper proposes a compensation algorithm for the secondary current of the air-gapped CT during the fault conditions including auto-reclosure as well as in the steady-state. The core flux is calculated from the measured secondary current of the CT and inserted into the hysteresis loop to estimate the exciting current. Finally, the correct current is estimated by adding the measured secondary current to the estimated exciting current. Various test results clearly indicate that the proposed compensating algorithm can improve the accuracy of the air-gapped CT significantly and reduce the required core cross-section of the air-gapped CT significantly.

정상상태에서 공극 변류기의 보상 (Compensation of an Air-Gapped Current Transformer in the steady state)

  • 강용철;박지연;소순홍;장성일;김용균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.15-17
    • /
    • 2006
  • This paper proposes a compensation method for an air gapped current transformer (CT) in the steady state. An air gapped CT is used in order to reduce a remanent flux in the case of auto-reclosure. It causes larger ratio and angle errors than the closed core CT because the magnetizing inductance of an air-gapped CT is even smaller than the closed-core CT. The core flux is calculated and used to estimate the exciting current in accordance with the hysteresis curve of the air-gapped CT The correct current is obtained by adding the estimated exciting current to the measured secondary current. The performance of the method was investigated for the air gapped CTs with a gap of 0.083mm and 0.249mm for the 120%, 100% and 20% of the rated current. Various test results indicate that the proposed compensation algorithm can improves the accuracy significantly.

  • PDF

초고압 계통에서의 공극 변류기의 과도 특성 분석 (Analysis of Transient Characteristics of Air-Gapped CTs In EHV Transmission Systems)

  • 강용철;윤재성;이병은;강상희;박종근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.294-296
    • /
    • 1999
  • This paper describes the transient characteristics of air-gapped CTs in EHV transmission systems. An air-gapped CT is modelled using EMTP. Air-gapped CTs with the gap of 0, 0.5, 1.0 [mm] are analysed and compared with and without consideration of auto-reclosure. From the results. even small gap improves the transient characteristics after auto-reclosure.