• Title/Summary/Keyword: Air-curtain

Search Result 136, Processing Time 0.027 seconds

Variation of Vapor Pressure Deficit and Condensation Flux of Air Heating Plastic Greenhouse Installed with Two Layers Thermal Curtain in Winter (이층커튼 온풍난방 플라스틱온실의 겨울철 포차 및 결로량 변화)

  • Lee, Hyun-Woo;Kim, Young-Shik;Sim, Sang-Youn;Lee, Jong-Won
    • Journal of Bio-Environment Control
    • /
    • v.22 no.1
    • /
    • pp.35-41
    • /
    • 2013
  • This study was conducted to provide data necessary for reducing the condensation on greenhouse covering in winter season. The variation of VPD (Vapor Pressure Deficit) and condensation flux was analyzed in experimental tomato greenhouse. VPD values in experimental plastic greenhouse were greater than 0.2 kPa of disease prevention threshold, and lower than 0.5 kPa of threshold for dehumidification. The surface temperature of inside covering was slightly higher than the average temperature of outside and above curtain, and changed according to outside temperature. The humidity above curtain was nearly 100% and good condition for condensation. The humidity below curtain was 75~90% and comparatively stable condition for growing. The condensation flux value in experimental greenhouse corresponded with result of Seginer and Kantz (1986).

Numerical analysis of solar heat gain on slim-type double-skin window systems - Heat transfer phenomena with opening of windows and vent slot in summer condition - (전산유체 해석을 통한 슬림형 이중외피 창호의 태양열 취득량 분석 - 높은 태양고도 및 하절기 냉방조건에서의 자연환기구 적용 및 창문 조절 방식별 비교 -)

  • Park, Ji-Ho;Oh, Eun-Joo;Cho, Dong-Woo;Cho, Kyung-Joo;Yu, Jung-Yeon
    • KIEAE Journal
    • /
    • v.17 no.1
    • /
    • pp.69-75
    • /
    • 2017
  • Purpose: Heat transfer analysis of recently developed 'slim type double-skin system window' were presented. This window system is designed for curtain wall type façade that main energy loss factor of recent elegant buildings. And the double skin system is the dual window system integrated with inner shading component, enclosed gap space made by two windows when both windows were closed and shading component effectively reflect and terminate solar radiation from outdoor. Usually double-skin system requires much more space than normal window systems but this development has limited by 270mm, facilitated for curtain wall façade buildings. In this study, we estimated thermophysical phenomena of our double-skin curtain wall system window with solar load conditions at the summer season. Method: A fully 3-Dimentional analysis adopted for flow and convective and radiative heat transfer. The commercial CFD package were used to model the surface to surface radiation for opaque solid region of windows' frame, transparent glass, fluid region at inside of double-skin and indoor/outdoor environments. Result: Steep angle of solar incident occur at solar summer conditions. And this steep solar ray cause direct heat absorption from outside of frame surface rather than transmitted through the glass. Moreover, reflection effect of shading unit inside at the double-skin window system was nearly disappeared because of solar incident angle. With this circumstances, double-skin window system effectively cuts the heat transfer from outdoor to indoor due to separation of air space between outdoor and indoor with inner space of double-skin window system.

Studies on Management of Effective Temperature and Humidity in Greenhouse at Summer Season (하절기 효율적인 하우스 온도 습도 관리에 관한 연구)

  • 우영회;남윤일;송천호;김형준;김동억
    • Journal of Bio-Environment Control
    • /
    • v.3 no.1
    • /
    • pp.58-65
    • /
    • 1994
  • It is necessary to effective temperature and humidity management for normal growth of crops in protected cultivation during the summer season. Because the highest temperature of vinyl house inhibit normal growth of crop and decrease of crop production or marketability in summer season. Finally, the vinyl house was impossible some crop cultivation in summer season. This study was conducted to investigate effective and economic method for temperature drop in protected cultivation during the summer season. 1. In medium size vinyl house(5$\times$13$\times$3m), the effect of temperature drop appeared the highest in treatment of shading with aluminium thermal curtain+fog system+ventilation with fan. The effect of temperature drop was about 1$0^{\circ}C$ lower than outer air temperature and about 4$^{\circ}C$ lower than outer soil temperature. 2. The effect of temperature drop according to shading with aluminium thermal curtain+fog system+ventilation with fan during the highest temperature of summer season Jul., 20 to Aug., 21 was appeared about 8$^{\circ}C$ lower than outdoor above ground(1.2m) and about 7$^{\circ}C$ lower than outdoor surface ground. 3. The changes of solar radiation during a day according to shading with aluminium thermal curtain+ventilation with fan and shading with black curtain+ventilation with fan treatments was appeared respectively about 29.3%, 32.5% of outdoor solar radiation a fine day and respectively about 27.4%, 31.8% of outdoor solar radiation a cloudy day.

  • PDF

Effects of Minimizing the Heating Space on Energy Saving and Hot Pepper(Capsicum annuum L.) Growth in the Plastic Greenhouse (온실 난방공간 최소화가 에너지 절감 및 고추 생육에 미치는 영향)

  • Tae Young Kim;Young Hoe Woo;Ill Hwan Cho;Young Sam Kwon;Si Young Lee;Han Ik Jang
    • Journal of Bio-Environment Control
    • /
    • v.10 no.4
    • /
    • pp.213-218
    • /
    • 2001
  • In 2000, domestic protected cultivation area was about 52,189 ha including 13,621 ha of heating greenhouses. Recently, heating cost accounts for 25 to 30% of total production cost which has been increased due to the rise of oil price, while the heating cost was about 15% in other advanced countries. To reduce the heating energy cost, the study of minimizing the heating space of greenhouse have been conducted from 1998 to 1999. The system was developed to control the heating space according to crop growth by moving horizontal curtain up and down. Installation of the heating space-control curtain in greenhouse decreased heating capacity to 264 m$^3$compared to 661.5 m$^3$in the traditional curtain, and consumpted fuel was saved about 56% point in semiforcing culture and 28% point in retarding culture of pepper. In addition, uniform distribution of air temperature and relative humidity in greenhouse environment resulted in earlier flowering and higher yields in hot pepper.

  • PDF

A Numerical Study on Smoke Behavior of Fishing Vessel Engine Room (어선 기관실의 연기 거동에 관한 수치해석 연구)

  • JANG, Ho-Sung;JI, Sang-Won
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.5
    • /
    • pp.683-690
    • /
    • 2021
  • The ventilation system of the engine room of a ship is generally installed to supply the combustion air necessary for the internal combustion engine and to remove the heat source generated in the engine room, and it must satisfy the international standard (ISO 8861) for the design conditions and calculation standards for the ventilation of the ship engine room. The response delay of the ventilation system including the fire detector is affected by the airflow formed inside the area and the location of the fire detector. In this study, to improve the initial fire detection response speed of a fire detector installed on a fishing vessel and to maintain the sensitivity of the installed detector, the smoke behavior was simulated using the air flow field inside the engine room, the amount of combustion air in the internal combustion engine, and the internal pressure of the engine room as variables. Analysis of the simulation results showed that reducing the flow rate in the air flow field and increasing the vortex by reducing the internal pressure of the engine room and installing a smoke curtain would accelerate the rise of the ceiling of the smoke component and improve the smoke detector response speed and ventilation system.

Survey of ICT Apply to Plastic Greenhouse, Rack·Pinion Adaption to Single Span and CFD Analysis (온실 ICT융복합 실태조사와 복숭아형 랙피니언천창 적용 단동온실 및 CFD 유동해석)

  • Cho, Kyu Jeong;Kim, Ki Young;Yang, Won Mo
    • Journal of Bio-Environment Control
    • /
    • v.24 no.4
    • /
    • pp.308-316
    • /
    • 2015
  • This study was conducted to investigate the situation of ICT apply to plastic greenhouse, and the results be apply to design of new one. A CFD analysis were conducted to monitering the ventilation and energy saving of the single span greenhouse newly designed. The causes of delay to apply ICT to plastic greenhouse are the high cost for installation(24%), insufficiency of after services(19%), often disorder(16%), unskillful management of soft ware(15%), insufficient ICT efficiency(13%) and unsatisfying of income increase(12%). The parts of problem occurred in ICT plastic greenhouse are the structure, actuator, environmental control system and sensor(approximate 14%, respectively), remote control technique(13%), plant management technique(12%), energy saving technique(10%) and utilization of software(8%). In the condition of lateral window closed, the average wind speed changed to slow, but it was faster in the condition of leeward side window opened than in the condition of lee and winward side window opened. The air movement in the condition of lateral window closed occur by air moving fan not by out air. It is not affect the room temperature but effective the uniformity of room temperature. The average temperature of low height greenhouse was uniform than high height one. The average temperature in condition of 3rd curtain opened become same with outside temperature after 2 hours, but take more 5 hours in condition of 3rd curtain closed.

Development of Cultivation Facility Models to Reduce High Temperature Damage in Oak Mushroom (Lentinula edodes) Cultivation Using Bed-logs (고온피해 경감을 위한 표고 원목재배사 모델개발)

  • Kim, Own-Su;Kim, Seon-Cheol;Lee, Byeong-Seok;Kwon, Hyuk-Woo;Ko, Han-Gyu;Park, Heung-Soo
    • Journal of Mushroom
    • /
    • v.14 no.3
    • /
    • pp.119-126
    • /
    • 2016
  • Five empirical farmhouses were selected to reduce the high temperature damage in oak mushroom cultivation using bed-logs. The cultivation facilities were categorized as follows: those having two blackout curtains or one blackout curtain and outdoor oak mushroom cultivation. The inequality of the indoor condition, oak mushroom hyphae rampant ratio, and fruit body production in each test condition was evaluated. $3^{\circ}C$ was lower in indoor temperature of cultivation facility having two blackout curtains than one blackout curtain. Specifically, the indoor air humidity average of cultivation facilities having one or two blackout curtains was 10% lower than that of outdoor oak mushroom cultivation. This condition is not ideal for oak mushroom cultivation as continuous indoor humidity control is essential for producing good fruit bodies. The Inoculated bed-log surface and oak mushroom hyphae rampant ratio of bed-logs cultivated with two blackout curtains was superior to other tested conditions. The mushroom production ratio observed in facilities with two blackout curtains was 117-204% higher than those cultivated in facilities with only one blackout curtain. Furthermore, the mushroom production ratio increased in based on these findings, we recommended five cultivation facility models to reduce high temperature damage in oak mushroom cultivation using bed-logs.

Airflow pattern of Double window system for Remodeling by using Integrated Simulation. (통합 시뮬레이션을 통한 리모델링용 이중창 시스템 기류 패턴 분석)

  • Kim, Eun-Hee;Nam, Hyun-Jin;Yook, In-Soo;Kim, Jeong-Yoon;Kim, Jae-Min
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1036-1041
    • /
    • 2008
  • Double facade systems are often paid attention of as an effective energy saving measure for curtain wall buildings. However, it is not easy to install the system in existing buildings and requires substantial investment. An innovative double window system is proposed in this study which can be installed with exiting window systems in a cost effective way. the proposed system is connected to existing return ducts to make airflow between the existing window and the newly installed window. To ensure the best performance of the proposed system, simulation-based analysis was implemented in which airflow characteristics of inside double window were examined according to air pressures of return duct and window material by using computer simulation ESP-r. the overview of the proposed system and the results of the simulation-based analysis are presented in this paper.

  • PDF

A Study on Change in Window Transmitted Solar and the Resultant Wall Surface Convective Heat Gain with Regard to Slat Reflectance of External and Internal Blinds (실내·외 블라인드의 Slat 반사율에 따라 창호 일사투과량 및 그에 따른 벽체 대류열획득량 분석)

  • Hyun, In-Tak;Lee, Jae-Ho;Yoon, Yeo-Beom;Lee, Kwang Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.565-571
    • /
    • 2014
  • Nowadays, to make buildings light weight and aesthetically pleasing, curtain wall structure are commonly used. Therefore, window to wall ratio is increasing, which has caused cooling and heating load in crease in buildings as well. This phenomenon has negative impact from energy point of view. This paper analyzes window and wall convective heat gain when the slat reflectance of external and internal blinds are changed for the better understanding of the fundamentals behind the phenomena. It was observed that, if slat reflectance is increased, window transmitted solar increases and convection heat rate is clearly affected. Among six surfaces including four walls, ceiling and floor, maximum convection heat rate occurs on the south wall in summer. On the other hand, ceiling and floor showed the lowest convection heat gain, since they are shared by adjacent floors.

Effect of Heat Insulation by Plastic Curtain with Air Cell in Greenhouse (플라스틱 공기막 커튼을 활용한 온실의 보온력 향상)

  • Kim, Hak-Ju;Lee, Si-Young;Yeom, Sung-Hyun;Nam, Yooun-Il;Jeon, Hee;Yoon, Nam-Kyu
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2003.04a
    • /
    • pp.203-206
    • /
    • 2003
  • 우리나라 시설원예 면적은 '95년 43,093ha에서 '01년 말 현재 52,125ha로 연평균 3.2%의 증가율을 보인 반면 난방면적은 연평균 10.8%씩 증가하여 12,710ha로 전체 시설재배 면적의 24.4%를 차지하고 있다. 또한 난방연료의 95% 이상이 경유이며, 최근 국제정세 불안 등으로 유가가 급등하여 시설재배농가의 연료비 부담은 더욱 가중되고 있다. (중략)

  • PDF