• Title/Summary/Keyword: Air-conditioning system

Search Result 3,316, Processing Time 0.032 seconds

Sliding Mode Control for Improving Performance of Mount with MR(Magneto-Rheological) Fluid (MR마운트 진동제어 성능 향상을 위한 슬라이딩 모드 제어)

  • Ahn, Young Kong;Kim, Sung-Ha;Jeong, Seok-Kwon
    • Journal of Power System Engineering
    • /
    • v.21 no.4
    • /
    • pp.18-25
    • /
    • 2017
  • This paper deals with vibration control of a small mount with MR(Magneto-Rheological) fluid as a functional fluid mount for precision equipment of automobiles. Damping and stiffness coefficients of the mount with MR fluid are changed by variations of the applied magnetic field strength. We present the robust control scheme, based on a conventional sliding mode control theory, for the design of a stable controller that is capable of vibration control due to various disturbances such as impact and periodic excitations, and is insensitive to dynamic properties of the mount. We got stable controller by using Lyapunov stability theory. The controller is then realized by using a semi-active control condition in simulations. Chattering problem of the sliding mode control is eliminated by saturation function instead of signum function. The sliding mode control with Lyapunov stability theory is superior to passive and Sky-Hook control in performance.

Improving Energy Self-sufficiency in Municipal Wastewater Treatment Plant using Renewable Energy Production (능동적 신재생에너지 생산을 통한 하수처리장 에너지자립화 향상)

  • Kang, Ji-Hoon;Chae, Kyu-Jung;Kim, Dong-Soo;Yang, Hee-Jung;An, Yeong-Seop;Kim, Won-Kyoung;Kim, Jeong-Hyeon;Park, Dong-Eul
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.643-643
    • /
    • 2012
  • Increasing energy prices and growing concerns about global warming address the need to improve energy self-sufficiency in many industrial and municipal sectors. Wastewater treatment plants (WWTPs) are representative of energy-consuming facilities in Korea, accounting for 5% of national energy consumption. We present renewable energy technologies and energy self-sufficiency scenarios in a municipal WWTP ($30,000m^3d^{-1}$) located in Yongin, South Korea. By employing photovoltaics (PV, 135 kW), small hydropower turbine (10 kW), and thermal energy from treated effluent (25 RT: refrigeration ton) within the WWTP, a total of 142 tonne of oil equivalent (toe) of energy was estimated to be generated, accounting for $365ton\;CO_2\;yr^{-1}$ of greenhouse gas emission reduction. Core renewable technologies under consideration include 1) hybrid solar PV system consisting of fixed PV, dual-axis PV, and building integrated PV, 2) low-head small hydropower plant specifically designed for treated effluent, 3) effluent heat recovery system for heating and air conditioning. In addition to these core technologies, smart operation and management scheme will be presented for enhancing overall energy savings and distribution within the WWTP.

  • PDF

The Study on Performance Characteristics in Refrigeration System using R717 and R22 as working fluid (냉매 R717과 R22를 작동유체로 이용한 냉동장치의 성능특성에 관한 연구)

  • Kim, Jin-Hyun;Kim, Jae-Geun;Kim, Jong-Gil;Kim, Yang-Hyun;Hong, Suk-Ju;Ha, Ok-Nam
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.495-500
    • /
    • 2006
  • Nowadays HCFCs refrigerant are restricted because it cause depletion of ozone layer. However, natural gases such as ammonia as an organic compound, propane and propylene as hydrocarbon are easy and cheap to obtain as well as environmental. Accordingly, this experiment apply the $NH_3$ and R22 to study the performance characteristic from the superheat control and compare the energy efficiency of two refrigerants from the high performance. The condensing pressure of refrigeration system is increased from 15bar to 16bar and degree of superheat is increased from 0 to $10^{\circ}C$ at each condensing pressure. As the result of experiment, when comparing the each COP, we knew the $NH_3$ is suitable as the alternative refrigerant of the R22.

  • PDF

Effect of supercooling and cooling rate on a continuous ice slurry formation using a plate heat exchanger (판형 열교환기에서 유동 과냉도 및 냉각속도가 연속제빙에 미치는 영향)

  • Lee, Dong-Gyu;Peck, Jong-Hyun;Hong, Hi-Ki;Kang, Chae-Dong
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.138-143
    • /
    • 2006
  • The peculiarity of ice slurry, such as liquidity, high heat transfer rate and easy storage can also find to supercooled type dynamic ice storage system(DISS) which is one of the DISS. However, in order to accomplish continuous ice formation in the system without mechanical moving parts, supercooled aqueous solutionshould be formed stable through cooling heat exchanger and be dissoluted in storage tank. In previous research, the time of ice slurry increased as the pressure of the cooling heat exchanger(PHX) increased. In this study, a cooling experiment of an ethylene glycol 7mass% solution was performed with various inlet temperature of the PHX, which has constant brine inlet temperature of $-7^{\circ}C$. The temperature in the storage tank maintained to freezing point of the solution. At results, the time of ice slurry formation increased as the supercooling degree decreased and the cooling rate increased.

  • PDF

Economic Analysis of Heat Pump System through Actual Operation (히트 펌프 냉난방 시스템의 실사용을 통한 경제성 분석)

  • Shin, Gyu-Won;Kim, Gil-Tae;Joo, Ho-Young;Lee, Jae-Keun
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.921-926
    • /
    • 2006
  • The present study has been conducted economic analysis through actual operation of EHP and GHP which are installed at the same building of an university Cost items, such as initial cost, annual energy cost and maintenance cost of each system are considered to analyze LCC and economical efficiency is compared. The initial cost is considered on the basis of actual costs, and annual energy cost is converted into the cost after measuring electricity and gas consumption a day. LCC applied present value method is used to assess economical efficiency of both them. Variables used to LCC analysis are electricity cost escalation rate, natural gas cost escalation rate, interest rate, and service lives and when each of them are 4%, 2%, 8%, and 20 years, results of analysis short that EHP(148,257,306 won) is 8.05%(12,981,990 won) more profitable than GHP(161,239,295 won).

  • PDF

A Study on the Operating Control of a 2-Stage Heat Pump System with Screw Compressors (스크류 2단 압축 열펌프 시스템의 운전 제어 방안에 관한 연구)

  • Kim, Ji-Young;Baik, Young-Jin;Lee, Young-Soo;Ra, Ho-Sang
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.501-505
    • /
    • 2006
  • A preliminary performance test of a 30RT 2-stage screw heat pump was carried out in order to develop a high performance large-scale unutilized energy source heat pump, which will be used in district heating and cooling. Two issues on the system control were investigated in this study, A stable 2-stage heating operation is guaranteed only if the load-side water inlet temperature is over a certain value, to where the 1-stage heating operation should be done first from a cold start. An oil shortage problem in low stage compressor, which depends on the degree of suction superheat, was solved by the proper oil level control scheme.

  • PDF

A Study on thermal performance of box type double skin facade and curtain wall in heating period (박스형 이중외피와 커튼월 창호의 난방기 열적성능 비교)

  • Park, Chang-Young;Choi, Chang-Ho;Lee, Keon-Ho;Yoon, Yong-Sang
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.909-914
    • /
    • 2006
  • The purpose of this study is to analyze the thermal of DFS(double Facade System) and curtain wall in the heating period. The physical difference between curtain wall and double facade on thermal performance has been tested at the newly constructed laboratory, which can turn $360^{\circ}$ to confirm the characteristic of a facade with the various directions. This study divide on 'ventilated, airtight' and 'heated or unheated' conditions from the CASE 1, 2, 3, 4. The results showed thermal performance of double facade system which has been better than curtain wall. The heating energy of DFS reduced $8%{\sim}10%$ of energy consumption. comparable to SFS in experemted results. In view of the researching results so far achieved, the research came to a conclusion, that the curtain wall can save the energy in the heating period than a curtain wall.

  • PDF

A Study on the Certified Ground Source Heat Pump and Performance Analysis (지열원 히트펌프 유닛 인증 현황 및 성능 분석에 관한 연구)

  • Chang Woo Yang;Hee Jeong Kang;Jong Min Choi
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.18 no.4
    • /
    • pp.22-32
    • /
    • 2022
  • To reduce energy consumption and CO2 emission in building sector, a ground source heat pump system has been highly adopted due to its high efficient by many regulation. A certification system has been operated to distribute reliable and high-efficient heat pump units. In this study, the performance status of the recently certified ground source heat pump unit with components was investigated. All heat pump units certified from 2015 to 2020 were water to water heat pump types. Compared to the past, higher capacity systems over 400 kW have been certificed. The cooling COP of the heat pump unit based on certification criteria showed higher value than the heating COP. It is highly recommended to revise the certified criteria values considering operating conditions individually. Most of ground source heat pump units have employed scroll type compressors and plate type heat exchangers with HFC refrigerant.

A Study on Reliability Improvement of Domestic Ground Source Heat Pump Units by Analyzing the Certification System (국내 지열원 히트펌프 유닛의 인증제도 분석을 통한 신뢰성 향상 방안 연구)

  • Chan Woo Yang;Hee Jeong Kang;Sewang Oh;Ubin Do;Kwang Ho Lee;Jong Woong Choi;Yong Cho;Jong Min Choi
    • New & Renewable Energy
    • /
    • v.19 no.4
    • /
    • pp.72-83
    • /
    • 2023
  • Only ground source heat pump units certified according to the regulations in Korea can be adopted in ground source heat pump systems. In this study, domestic and international standards and regulations for ground source heat pump units were investigated. Unlike ISO 13256-1~2, which is the international standard, KS B 8292~8294 for ground source heat pump unit only included rated test conditions. Therefore, it is necessary to supplement various test conditions to the KS B series, because its performance data, which is required to calculate the system's design capacity, is dependent on the change in entering water temperature. The difference between the coefficient of performance of the certified ground source heat pump units and the certified criteria changed significantly according to the operating mode, heat source, and load type, because the criteria increased by about 5% for all. Thus, it is highly suggested that the certification standards be revised while considering the product performance level and various conditions.

A Numerical Study of Automotive Indoor Thermal Comfort Model According to Boarding Conditions and Parameters Related to HVAC (HVAC 관련 매개변수 및 탑승조건에 따른 자동차 실내의 온열쾌적성 평가모델에 관한 수치해석적 연구)

  • Yoon, Seong Hyun;Park, Jun Yong;Son, Deok Young;Choi, Yunho;Park, Kyungseok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.9
    • /
    • pp.979-988
    • /
    • 2014
  • Recently, the interest in the thermal comfort is ever increasing as the time people stay in the automobile is gradually increasing. So far, however, the cooling performance of the HVAC(heating and ventilation air conditioning) system is evaluated by thermal environment criteria such as indoor air velocity and temperature, not by a thermal comfort index. Furthermore, the precise criteria has not been established yet when the thermal comfort for the automobile is evaluated using numerical analysis. In this study, the numerical analysis of automobile indoor thermal comfort according to various parameters such as HVAC operating mode, airflow, passenger boarding conditions is performed during the HVAC system's initial operating time(20 minutes). The solar ray tracing model and S2S radiation model are used and validated to simulate an external heat source. Based on this study, an evaluation model which can predict the thermal comfort index for the combination of the above parameters is presented.