• 제목/요약/키워드: Air-conditioners

검색결과 227건 처리시간 0.027초

Bass 확산모형을 이용한 가정용 냉장고의 보급추정 및 효율향상에 따른 경제성 분석 연구 (A study on the Distribution Estimation of Residental Refrigerators using Bass Diffusion Model and Economic Analysis Corresponding to Enhancement of Energy Efficiency)

  • 백정명;원종률;이병하;김정훈
    • 전기학회논문지
    • /
    • 제57권11호
    • /
    • pp.1938-1945
    • /
    • 2008
  • Due to rapid economic growth, the usage of residential cooling electrical appliances such as air conditioners and refrigerators has increased dramatically for the last decades. In other to reduce its energy consumption, the authorities have applied energy efficiency standards for principal appliances, including refrigerator. This paper estimates the distribution of refrigerators using the Bass Diffusion Model and then performs economic analysis corresponding to enhancement of energy efficiency more correctly than existing methods.

Development of the Broadband PLC Home Controller using JINI Surrogate

  • Kim, Yong-Seok;Kim, Hee-Sun;Lee, Chang-Goo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1563-1567
    • /
    • 2005
  • The Home network system means that information appliances, Home PCs, etc., using wired or wireless network method enable to control and share with peripheral devices such as internet, shared data, a scanner and a printer, and it is networking solution, which intelligent communication will be possible as the system which can do a remote control such as TV Set, refrigerators, air conditioners, DVD players, digital camcorders based on external network using an internet, a potable information terminal and a mobile phone whenever, wherever and freely. In this study, the home network interface solution is used one of the wired network standards, PLC (Power-Line Communication) technology, so we can construct of intelligent home network's home controller without re-build a network at home. On keeping with current waves of thought, we will focus on a home controller development with great interest which is enabled to do an effective managed control, applying intelligent home network technology which can be new paradigm like a cyber apartment.

  • PDF

압축기의 수명실험에서의 AE 신호를 이용한 상태감시 (State Monitoring of Compressor using AE Signal in Life Test)

  • 정지홍;강명창;노태영;이감규
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.56-60
    • /
    • 1997
  • The compressor is one of important elements in refrigeration cycle and play an important role of refrigeration efficiency and quality. This paper analyzes slides in rotary compressors for room air conditioners, monitoring using Acoustic Emission(AE) technique. Reliability of rotary compressors which are factory-tested has been evaluated through visual inspection on taking them apart after long term test, which is life test. This paper describes methods for acquisition and processing of Acoustic Emission(AE) raw signal to monitor state of rotary compressor in Life Test.

  • PDF

냉각수 보급이 가정용 흡수식 냉난방기의 성능에 미치는 영향 (Effect on Household Absorption Chiller by the Supply of the Cooling Water)

  • 이호생;김동휘;최병권;김재돌;윤정인
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2002년도 춘계학술대회논문집
    • /
    • pp.267-272
    • /
    • 2002
  • The electric heat pump requiring HCFCs as a refrigerant has been for most residential air-conditioners in Korea. They cause a surge up electric power demand during summer. Moreover, the use of HCFCs and HFCs causes a serious problem to the global environment such as global warming and ozone layer destruction. An absorption chiller and heater could solve such problems. It was built and tested for analyzing the performance of the absorption chiller/heater. Experiment was done with a 1.5RT household absorption chiller and heater. It was experimented that the cooling capacity, gas capacity, COP were researched by the temperature of cooling water. The change of the cooling water temperature have effect the temperature(or pressure) of the parts on absorption chiller The result of the change of the cooling water temperature have the effects of the absorption chillers. This data will help to operate the household absorption chiller and heater.

  • PDF

AE 신호를 이용한 회전형 압축기의 이상상태 감시 (The Abnormal Condition Monitoring of Rotary Compressor using Acoustic Emission)

  • 이감규;정지홍;김전하;강명창;김정석
    • 한국공작기계학회논문집
    • /
    • 제13권5호
    • /
    • pp.118-123
    • /
    • 2004
  • The compressor has one of important roles in refrigeration cycle and it determines refrigeration efficiency and quality This paper aims to monitor rotary compressors for room air conditioners by using Acoustic Emission(AE) technique. The reliability of rotary compressors has been evaluated through visual inspection on them after long term test. This paper describes methods for acquisition and processing AE raw signal to monitor the state of rotary compressor. A detecting method of abnormal compressor in real time is suggested and special-purpose monitoring system which can be applied to automatic manufacturing line is developed using one-chip microprocessor at low cost.

A Study on Low-Cost Sensorless Drive of Brushless DC Motor for Compressor Using Random PWM

  • Shin, Duck-Shick;Kim, Dae-Kyong
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권1호
    • /
    • pp.91-96
    • /
    • 2013
  • Recently, it is increased to apply sensorless drive for BLDC (Brushless DC) motor to household electrical appliances, especially in the refrigerators and air conditioners, to reduce the cost and the acoustic noise by the operation and to make their functions more comfortable for human beings. In this paper, low-cost sensorless drive for BLDC motor is implemented by random PWM (Pulse Width Modulation). The experimental results show that the electromagnetic noise was reduced and the sound quality was improved by BLDC motor sensorless random PWM Control.

The System of Waste Home Appliances Recycling in Taiwan

  • Ma, H.K.;Li, K.C.;Wu, N.M.;Chang, W.C.
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 The 6th International Symposium of East Asian Resources Recycling Technology
    • /
    • pp.43-47
    • /
    • 2001
  • The waste home appliances including television sets, refrigerators, washing machines and air conditioners have increasingly received environmental concerns in Taiwan. In light of the enforcement of Waste Disposal Act (WDA), the Taiwan Environmental Protection Administration (EPA) has certified 60 recycling/storage facilities and given permission for qualified companies to build six treatment plants around the island. Now the recycling and well treatment home appliances are estimated to be 3,342,369 units until May 31, 2001. This paper describes the present status of waste home appliance recycle and its treatment in Taiwan. The principle guidelines and policies regarding recycling, resource recovery and environmental concerns are presented.

  • PDF

인터넷을 이용한 공동주택의 에너지소비특성 실태조사 (An Internet-based Survey on the Characteristics of Energy Consumption of Apartment)

  • 황광일
    • 한국주거학회논문집
    • /
    • 제13권6호
    • /
    • pp.41-48
    • /
    • 2002
  • The purpose of this study is, by the method of the internet-based survey, to understand the relations between the residential condition and the characteristics of energy consumption. The followings are the results of this study. $\circled1$ Among 601 responses, evaluable 329s means that the user fully understanding what this survey is for. $\circled2$ Gas-or oil-burners occupy 80% of heater. $\circled3$ Contrary to expectations, we can not find out the relations between the cooling area and the cooling capacity of Air-conditioners. $\circled4$ There is no relation between the direction of apartment and the cooling capacity, neither. $\circled5$ During the summer, average and maximum monthly electric fare for cooling is ₩198/$\textrm{m}^2$ and ₩461/$\textrm{m}^2$, respectively. $\circled6$ And during the winter, average and maximum monthly electric fare for heating is ₩335/$\textrm{m}^2$ and ₩484/$\textrm{m}^2$, respectively.

에어컨에서 직렬아크검출 알고리즘에 관한 연구 (A Study on the Detection Algorithm of Series Arc Signals in Air Conditioners)

  • 지홍근;최성국;정광석;박대원;길경석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1970-1976
    • /
    • 2009
  • This paper describes a series arc detection algorithm in a low-voltage wiring system. We designed and fabricated an arc detection circuit which consists of a high-pass filter with the low cut-off frequency of 170 kHz to attenuate power frequency. The series arcing phenomena was simulated by an arc generator specified in UL1699. In the experiment, various loads such as resistive loads, resistive loads controlled by a dimmer, and vacuum cleaners were used. Whether the signal is arc or noise is discriminated by pulse counts and periodicity of the detected signal.

  • PDF

전동차 차량 네트워크 성능 모니터링 시스템에 관한 연구 (A Study of monitoring system for train communication networks)

  • 이대은;손수국;손강호;전성준
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1871-1879
    • /
    • 2008
  • A few years ago, The trains had little control equipment so the trains had little data transmission between control equipment. Recently, there is a lot of control equipment in a train as traction control, air conditioners and even internet access. for this reason, vehicle network must allow for the big amount of transmission data and must ensure the high reliability. In this paper we present monitering system for verify high reliability of data transmission of MVB of TCN which is an international standard of IEC 61375.

  • PDF