• Title/Summary/Keyword: Air-conditioner

Search Result 777, Processing Time 0.02 seconds

An experimental study on the performance of a window system air-conditioner using R407C and R410B (R407C 및 R410B 적용 창문형 에어컨의 성능에 관한 실험적 연구)

  • Kim, M.H.;Shin, J.S.;Kim, K.J.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.4
    • /
    • pp.536-544
    • /
    • 1997
  • This study presents test results of a residential window system air-conditioner using R22 and two potential alternative refrigerants, R407C and R410B. A series of performance tests was performed for the basic and liquid-suction heat exchange cycle in a psychrometric calorimeter test facility. For R407C, the same rotary compressor was used as in the R22 system. However, compressor for the R410B system was modified to provide the similar cooling capacity. The evaporator circuit was changed to get a counter-cross flow heat exchanger to take advantage of zeotropic mixture's temperature glide, and liquid-line suction-line heat exchange cycle was also considered to improve the performance of the system. Test results were compared to those for the basic R22 system.

  • PDF

Thermal Environment Analysis of a Classroom by CFD Simulation to Determine Optimal Temperature Sensor Position in Ceiling Type Air-Conditioning System (천정형 에어컨 온도센서의 최적 위치 결정을 위한 교실의 CFD 열환경 분석)

  • Li, M.H.;Kim, D.G.;Kum, J.S.;Jeong, S.K.
    • Journal of Power System Engineering
    • /
    • v.10 no.4
    • /
    • pp.43-49
    • /
    • 2006
  • Nowadays, the thermal environments of classrooms are usually adjusted by the ceiling type air-conditioning system with a temperature sensor installed on inlet of an air-conditioner. However, it is not clear that the conventional temperature sensor position is proper to satisfy both thermal comport and energy saving in summer especially. Therefore, this study is aimed at finding out the best position of the temperature sensor on the purpose of the comfort thermal environment and energy saving. The different 5 positions for the temperature sensor are supposed in this paper to analyze thermal environment by CFD. From the analysis through the CFD simulations, the best position of the temperature sensor satisfying for both comfort thermal environment and energy saving is obtained.

  • PDF

Development of Simulation Program for Multi-Air conditioner (멀티에어컨의 성능해석 프로그램 개발)

  • Jeong, B.Y.;Koh, J.Y.;Park, B.D.;Yim, C.S.
    • Solar Energy
    • /
    • v.20 no.1
    • /
    • pp.63-72
    • /
    • 2000
  • In this study, theoretical simulation method for the steady state characteristics of a refrigeration cycle which consists of one condenser and multi-evaporator (Multi-air conditioner) is presented. The simulation was performed for a typical multi-air conditioning system consisted one outdoor unit with air-cooled condenser, compressor, linear electric expansion valve and bypass circuit and connected three-evaporators (three indoor units). The simulation results are good agreement with those of experiments within 5 $\sim$ 10% at the given system operation conditions which are condensing pressure, evaporating pressure, sub-cooled degree of condenser, superheated degree, discharge temperature of compressor and pulse of linear electric expansion valve.

  • PDF

Study on Pressure Pulsation and Cavity Resonance in Discharge Plenum of Hermetic Compressor (공조용 밀폐형 압축기의 토출부 압력맥동 및 케비티 공명에 대한 연구)

  • 이진갑
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.3
    • /
    • pp.302-308
    • /
    • 2000
  • The major source of noise in air-conditioner is a compressor. Therefore, noise reduction in a compressor is quite significant as an element technology in air-conditioner field. Recently, a scroll compressor is widely used, because a scroll compressor features lower noise, due to less pulsation of gas pressure, than that of the rotary compressor. During a past noise reduction effort on a scroll compressor, noise radiation from the discharge portion of the hermetic shell was identified as the major contributor to overall noise. For a reduction of noise, the source of noise at the discharge portion must be identified. This paper presents detailed analyzes for the discharge pressure pulsation and cavity resonance at discharge space, which will make possible a low noise design of a scroll compressor.

  • PDF

Non-destructive Reliability Evaluation of Electronic Device by ESPI (ESPI를 이용한 전자부품 비파괴 신뢰성평가)

  • Yoon, Sung-Un;Kim, Koung-Suk;Jo, Seon-Hyung;Kang, Ki-Soo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.6
    • /
    • pp.630-633
    • /
    • 2001
  • This paper propose electronic speckle pattern interferometry(ESPI) for reliability evaluation of electronic device. Especially, vibration problem in a fan of air conditioner, motor of washing machine and etc. is important factor to design the devices. But, it is difficult to apply previous method, accelerometer to the devices with complex geometry. ESPI, non-contact measurement technique applies a commercial fan of air conditioner to vibration analysis. Vibration mode shapes, natural frequency and the range of the frequency are decided and compared with that of FEM analysis. In mechanical deign of new product, ESPI adds weak point of previous method to supply effective design information.

  • PDF

Fatigue-characteristic Evaluation of a Ventilating Blade in the Air-conditioner (냉방기용 송풍 Blade의 피로특성 평가)

  • Choi, Jung-Hun;Koo, Jae-Mean;Seok, Chang-Sung;Kim, Jong-Hak;Chang, Sung-Yong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.11
    • /
    • pp.72-77
    • /
    • 2010
  • The fatigue characteristic of a material or a structure is derived from fatigue tests of standard specimens. However, many test results of standard specimens are very different from those of real structures. One reason for this difference is the constraint effects according to the geometrical difference. Therefore, to calculate more accurate fatigue life, the constraint effect must be considered by comparing test results of standard specimens with those of real structures. In this study, a blade of an air-conditioner was evaluated by both the test and the analysis. The results showed that a standard specimen is conservative, compared with a structure specimen. And fatigue life of an air-conditioner's blade was predicted from those.

Optimum Design of an Indoor Package Air-Conditioner's Flow Path by Taguchi Method (다구찌 방법에 의한 PAC 실내기 유로의 최적설계)

  • Kim, Jang-Kweon;Oh, Seok-Hyung
    • Journal of Power System Engineering
    • /
    • v.18 no.1
    • /
    • pp.32-37
    • /
    • 2014
  • In this study, the optimum design process of an indoor package air-conditioner (PAC) was implemented by Taguchi method. The goal of this study is to obtain the best set condition of each control factor composing of an indoor PAC. The number of revolution of a double inlet sirocco fan installed in an indoor PAC was measured by the orthogonal array of $L_{18}(2^3{\times}3^4)$ and analysed by using the-smaller- the-better characteristic among the static characteristic analyses. As a result, the optimum condition of an indoor PAC was found as a set of when the cost of production, assembling and working conditions were considered. Moreover, the number of revolution of a double-inlet sirocco fan used for an optimum condition was reduced about 8.5% more than that of a standard condition for the target flowrate of $18.5m^3/min$.

Evaluation for the Capability of the Sound Insulation and Experimental Analysis for the Improvement of the Sound Insertion Loss of the Air Conditioner-cabinet Considering the Thickness and Aperture of the Partition (파티션의 두께 및 틈새를 고려한 에어컨 캐비닛의 차음 성능 평가 및 음향 삽입 손실 향상에 대한 실험적 분석)

  • Han, Hyung-Suk;Jung, Woo-Seoung;Mo, Jin-Yong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.2
    • /
    • pp.263-271
    • /
    • 2008
  • Compressor radiated noise is one of the dominant noise for the outdoor unit of the air conditioner. Therefore, air conditioner makers are trying to reduce it continuously. Even though noise absorption and isolation technology are one of the important parts for reducing the noise from the compressor, it is usually treated to the substitute technology when the noise from the compressor is very difficult to reduce by the compressor noise control only. In this paper, we focus on the property of the sound insulation for the cabinet and measure it applying the theory of the sound transmission loss and insertion loss of the simple enclosure. The insertion loss is evaluated by the experiments according to the thickness and the aperture of the partition in the cabinet.

The Variation of Multi Air Conditioner Operation Characteristics with the Arrangements of Connection Pipe Lengths (멀티에어컨의 연결 배관길이의 변화에 따른 운전특성 변화)

  • Park, B.D.;Ha, D.Y.;Jeong, B.Y.;Koh, J.Y.;Yim, C.S.
    • Solar Energy
    • /
    • v.20 no.4
    • /
    • pp.45-52
    • /
    • 2000
  • Multi A/C is consisted of one outdoor unit and several indoor units. When the Multi Air conditioner is installed, we have to be cautious of the length of pipe arrangements. When the pipe arrangement is installed with unbalance or too long, there can be cooling capacity losses and low EER. An experimental study was carried out about the operation characteristic of Multi Air conditioner varying the length of pipe arrangements. If the pipe arrangement of the system is 15m, the cooling capacity and EER were decreased 0.8% and 1.3% respectively compared to the case when pipe arrangement is 5m. In case of 25m, the cooling capacity and EER were decreased 10.7% and 12.2% respectively compared to the case of 5m. When the length of pipe is not same each other, it is profitable to make the pipe length of highest capacity indoor unit shortest.

  • PDF

Temperature characteristics of condenser and evaporator of Air-conditioner applying variable capacity compressor under cooling condition (가변용량 압축기를 적용한 에어컨의 냉방운전 시 응축 및 증발온도 특성)

  • Kwon, Young-Chul;Chun, Chong-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.6
    • /
    • pp.1325-1331
    • /
    • 2007
  • In order to investigate the cooling capacity of an air-conditioner applying a variable capacity compressor and the temperature characteristics on a condenser and an evaporator, the experiment on the operation characteristics of the air-conditioner was performed along a compressor operation ratio and an indoor/outdoor temperatures, under a cooling operation mode. The system characteristics were measured by the psychrometric calorimeter. The cooling capacity increased with decreasing the outdoor temperature and increasing the indoor temperature. Also, it increased with increasing the compressor operation ratio. The temperature of the condenser was more sensitive for the variation of the outdoor temperature and the temperature of the evaporator was more sensitive for the variation of the indoor temperature. The operation characteristics of the cycle used in this present were also analyzed by a pressure-enthalpy chart.

  • PDF