• 제목/요약/키워드: Air-breathing fuel cell

검색결과 19건 처리시간 0.025초

자연급기 무가습 연료전지의 Dry-out조건 (Dry-out conditions of free-breathing PEMFC with dry $H_2$ gas)

  • 박상균
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권2호
    • /
    • pp.225-230
    • /
    • 2006
  • This study investigates drying condition when a small fan is added to a operating the free-breathing proton exchange membrane fuel cells (PEMFCs) with dry $H_2$ and Air. Polarization tests were conducted on PEMFCs at cell temperatures between 30 and $50^{\circ}C$ under dry operation. In the results, the cell performance strongly depended on the cell temperature and the cathode gas stoichiometric flow rates. The cell performance increases as cell temperature decreases from 50 to $30^{\circ}C$. In the domain where the stoichiometry of air is quite large, reduction of the concentration overpotential compensated the increased internal resistance due to drying. The maximum performance was obtained at the small air flow rate beyond which flooding occurs. This indicates that the fan should be operated in the stoichiometry domain with a well designed cell structure to avoid flooding.

연성 기판을 전류 집전체로 사용한 평판형 연료전지 스택 (Miniature planar stack using the flexible Printed Circuit Board as current collectors)

  • 김성한;차혜연;;차석원;장재혁
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1-4
    • /
    • 2008
  • Fuel cells have the potential of providing several times higher energy storage densities than those possible using current state-of-the-art lithium-ion batteries, but current energy density of fuel cell system is not better than that of lithium-ion batteries. To achieve the high energy density, volume and weight of fuel cell system need to be reduced by miniaturizing system components such as stack, fuel tank, and balance-of-plant. In this paper, the thin flexible PCB (Printed circuit board) is used as a current collector to reduce the stack volume. Two end plates are made from light weight aluminum alloy plate. The plate surface is wholly oxidized through the anodizing treatment for electrical insulation. The opening rate of cathode plate hole is optimized through unit cell performance measurement of various opening rates. The performances are measured at room temperature and ambient pressure condition without any repulsive air supply. The active area of MEA is 10.08 $cm^2$ and active area per a unit cell is 1.68 $cm^2$. The peak power density is about 210 mW/$cm^2$ and the air-breathing planar stack of 2 Wis achieved as a small volume of 18 cc.

  • PDF

$NaBH_4$를 이용만 공기호흡형 수소연료전지에 대한 연구 (Planar, Air-breathing PEMFC Systems Using Sodium Borohydride)

  • 김진호;황광택
    • 한국수소및신에너지학회논문집
    • /
    • 제20권4호
    • /
    • pp.300-308
    • /
    • 2009
  • In a pursuit of the development of alternative mobile power sources with a high energy density, a planar and air-breathing PEMFCs with a new type of hydrogen cartridge which uses onsite $H_2$ generated from sodium borohydride ($NaBH_4$) hydrolysis have been investigated for use in advanced power systems. Two types of $H_2$ generation through $NaBH_4$ hydrolysis are available: (1) using organic acids such as sulphuric acid, malic acid, and sodium hydrogen carbonate in aqueous solution with solid $NaBH_4$ and (2) using solid selected catalysts such as Pt, Ru, CoB into the stabilized alkaline $NaBH_4$ solution. It might therefore be relevant at this stage to evaluate the relative competitiveness of the two methods mentioned above. The effects of flow rate of stabilized $NaBH_4$ solution, MEA (Membrane Electrode Assembly) improvement, and type and flow control of the catalytic acidic solution have been studied and the cell performances of the planar, air-breathing PEMFCs using $NaBH_4$ has been measured from aspects of power density, fuel efficiency, energy density, and fast response of cell. In our experiments, planar, air-breathing PEMFCs using $NaBH_4$ achieved to maximum power density of 128mW/$cm^2$ at 0.7V and energy efficiency of 46% and has many advantages such as low operating temperature, sustained operation at a high power density, compactness, the potential for low cost and volume, long stack life, fast star-up and suitability for discontinuous operation.

공기호흡형 고분자연료전지의 운전특성에 대한 연구 (The Operating Characteristics of Air-Breathing Type PEFCs)

  • 손영준;임성대;박구곤;김경연;김민진;이원용
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 추계학술대회 논문집
    • /
    • pp.44-46
    • /
    • 2008
  • Air-breathing polymer electrolyte membrane fuel cells (PEMFC) are highly promising particularly for small-power applications up to tens watts class. A distinctive feature of the air-breathing PEMFC is its simple system configuration in which axial fans operate for dual purposes, supplying both oxidant and coolant in a single manner. In the present study, a nominal 80W air-breathing PEMFC system is developed and investigated to determine the optimal operating strategy through parametric studies (i.e., reactant humidity, and fanblowing flow rate). The cell voltage distributions are examined as a function of time to evaluate the system performance under various operating conditions.

  • PDF

수동급기 직접 메탄올 연료전지의 공기극 물 관리 (Water management for vapor-fed direct methanol fuel cells)

  • 장익황;차석원;하승범;이윤호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.319-322
    • /
    • 2009
  • This paper investigated environmental effects for passive, air-breathing, and vapor-feeding direct methanol fuel cells. In these experiments, experimental parameters are temperature($30^{\circ}C$, $40^{\circ}C$ and relative humidity(25%, 50%, 75%). From these experimental results, the water contents play a key role in terms of optimal ionic conductivity at the cathode catalyst layer. In case of pure methanol feeding, the performance is inversely proportional to the relative humidity. The water generation resulting from methanol crossover maintains ionic conductivity at the cathode. On the contrary, diluted methanol solution (50wt.%) lowers methanol crossover to the cathode. In order to increase ionic conductivity, the relatively high humidity is required to the cathode catalyst layer for the water generation. The relative humidity scales with the performance.

  • PDF

NaBH4를 이용한 수소발생반응의 촉매에 관한 연구 (A Study on the Catalysts for Hydrogen Generation Reaction Using NaBH4 Solution)

  • 정성욱;조은애;오인환;홍성안;김성현;서용교
    • 한국수소및신에너지학회논문집
    • /
    • 제14권2호
    • /
    • pp.114-121
    • /
    • 2003
  • Hydrogen generation system using aqueous $NaBH_4$ solution was developed for feeding small polymer electrolyte membrane fuel cells (PEMFCs). Ru was selected as a catalyst with its high activity for the hydrogen generation reaction. Hydrogen generation rate was measured with changing the solution temperature, amount of catalyst loading, $NaBH_4$ concentration, and NaOH (a base-stabilizer) concentration. A passive air-breathing 2 W PEMFC stack was operated on hydrogen generated using $20wt%\;NaBH_4+5wt%$ NaOH solution and Ru catalyst.

도금된 폴리카보네이트 분리판을 이용한 공기 호흡형 고분자 전해질막 연료전지에 관한 연구 (Study of Air-Breathing Polymer Electrolyte Membrane Fuel Cell Using Metal-Coated Polycarbonate as a Material for Bipolar Plates)

  • 박태현;이윤호;장익황;지상훈;백준열;차석원
    • 대한기계학회논문집B
    • /
    • 제37권2호
    • /
    • pp.155-161
    • /
    • 2013
  • 본 연구에서는 도금된 폴리카보네이트를 사용하여 공기호흡형 고분자 전해질막 연료전지의 분리판을 제작하였다. 도금층은 구리 $40{\mu}m$, 니켈 $10{\mu}m$, 금 $0.3{\mu}m$ 로 구성되었으며, 구리는 전기 전도층, 니켈은 구리와 금의 결합, 금은 도금층의 부식을 방지하기 위해 사용되었다. 본 분리판을 사용하여 성능을 평가한 결과 $120mW/cm^2$ 의 전력 밀도를 보였으며 이는 동일한 조건에서 그라파이트 분리판을 사용했을 때의 전력밀도와 거의 차이가 나지 않았다. 또한 평판형 12 층 스택의 공기호흡형 연료전지를 구성한 결과 각 전지당 $132.7mW/cm^2$ 의 성능을 보였으며 이를 12 시간 운전해본 결과 안정적인 성능을 보여 공기호흡형 고분자 전해질 연료전지의 분리판으로 적합함을 확인하였다.

고온형 멤브레인을 사용한 메탄올 개질 연료전지의 개질기 일체형 평판 설계 (Planar fuel cell design integrated with methanol reformer by using a high temperature membrane)

  • 김성한;장재혁;길재형;이홍렬;차혜연;구보성;정창렬;쿤두;미씨;오용수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.467-470
    • /
    • 2006
  • For a mobile application such as cellular phone, micro fuel cells should be extremely compact and thin. RHFC can be an alternative solution because RHFC gives higher power density than DMFC and does not need ahydrogen storage vessel In this paper, RHFC using methanol fuel is made as a novel planar design without a PROX. Both reformer and cell are made closely in a same plate to share the heater of reformer with the cell. The PBI membrane is used in the cell. The reason is that high temperature of reformer can cause a performance drop when perfluorosulfonic acid membrane such as Nafion is used such a high temperature operation also guarantees the higher CO tolerance to MEA catalyst. The cell is designed as an air-breathing type which the cathode of the cell is opened to the air. The commercial Cu/ZnO/Al2O3 steam reformer catalyst is packed in reformer channel. The active area of MEA is $11.9cm^2$ and the peak power density was $27.5mW/cm^2$.

  • PDF