• 제목/요약/키워드: Air-borne Noise

검색결과 107건 처리시간 0.025초

에어컨의 구조 소음 저감을 위한 실내기 모터 브라켓의 설계 (The Design of the Motor Bracket for Reduction of Structure-Borne Noise in Package Air-Conditioner)

  • 심현진;김성현;강태호;이정윤;오재응
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.453-456
    • /
    • 2005
  • In recent years, the demand of a silent indoor air-conditioner is the essential research filed when the product is developed. In this study, through the design modification of the noise and vibration source, the noise and vibration level of the package air-conditioner is reduced. The modal analysis of the motor bracket is performed by FEM. To find the most suitable shape of the motor bracket, Design of Experiments is applied.

  • PDF

크리트 가진법을 이용한 타이어특성에 따른 로드노이즈 예측 연구 (Road Noise Prediction Based on Frequency Response Function of Tire Utilizing Cleat Excitation Method)

  • 박종호;황성욱;이상권
    • 한국소음진동공학회논문집
    • /
    • 제22권8호
    • /
    • pp.720-728
    • /
    • 2012
  • It is important for identification of noise and vibration problem of tire to consider influence of interaction between road and tire. A quantification of road noise is a challenging issue in vehicle NVH due to extremely complicated transfer paths of road noise as well as the difficulty in an experimental identification of input force from tire-road interaction. A noise caused by tire is divided into road noise(structure-borne noise) and pattern noise(air-borne noise). Pattern noise is caused by pattern shape of tire, which has larger than 500 Hz, but road noise is generated by the interactions between a tire and a vehicle body. In this paper, we define the quantitative analysis for road noise caused by interactions between tire and road parameters. For the identification of road noise, the chassis dynamometer that is equipped $10mm{\times}10mm $ square cleat in the semi-anechoic chamber is used, and the tire spindle forces are measured by load cell. The vibro-acoustic transfer function between ear position and wheel center was measured by the vibro-acoustic reciprocity method. In this study three tires with different type of mechanical are used for the experiment work.

Acoustic Transfer Function을 이용한 실차 실내 소음 예측 (Prediction vehicle interior noise using Acoustic Transfer Function)

  • 고성규;신한승;조환철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 춘계학술대회 논문집
    • /
    • pp.534-537
    • /
    • 2011
  • This Paper present prediction Vehicle Interior Noise using ATF(Acoustic Transfer Function) and engine radiated sound power. This is useful tool to qualifying the effectiveness of Air-borne noise Path. Furthermore This method provide acoustic package performance of the vehicle and able to prepare frequency band to same segment or benchmarking vehicle.

  • PDF

에어컨의 구조 소음 저감을 위한 실내기 모터 브라켓의 설계 (The Design of the Motor Bracket for Reduction of Structure- Borne Noise in Package Air-Conditioner)

  • 심현진;이성진;강태호;이정윤;오재응
    • 대한기계학회논문집A
    • /
    • 제30권2호
    • /
    • pp.202-209
    • /
    • 2006
  • As the economic power is improved and the customer's demand is hard to please, the noise and vibration is the most important yardstick that can determine the quality of the product. Especially, as the airconditioner's demand increase suddenly, the product of quality and the noise is becoming a decisive factor of determining whether purchase the product or not. Therefore, every manufactory is investing a lot of money and research to cut down the unpleasantness induced from noise and vibration. And they are emphasizing their product's difference by advertising a silence very actively. With these reason, the demand of a silent indoor air-conditioner is the essential research filed when the product is develop(:d. In this study, the noise and vibration is visualized in the space and frequency domain by using experimental methods such as operational deflection shape (ODS), modal testing and sound intensity. Also the location of noise source and its characteristic is analyzed in an acoustical point of view to reduce the structure borne noise that come from the fan motor, and the pertinent control method is suggested. Furthermore, the most suitable shape of the motor bracket is suggested by applying FEM and DOE (Design of experiments) in the noise and vibration point a view.

무한 평판 주위에 형성된 수중 기포층의 방사소음 감소 효과 (Noise Reduction Effect of an Air Bubble Layer on an Infinite Flat Plate)

  • 김종철;오준석;조대승
    • 한국소음진동공학회논문집
    • /
    • 제17권2호
    • /
    • pp.168-176
    • /
    • 2007
  • The mixture sound speed in bubbly fluids is highly dispersive due to differences of the density and compressibility between bubbles and fluids. The dispersion range in bubbly fluids expands to a higher frequency than the resonance frequency of an air bubble. A theoretical model was developed to compute the reduction of radiation noise that is generated by a force applied on an infinite flat plate using a bubble layer as a compliant baffle. For evaluating the effectiveness of a bubble layer in reducing the structure-borne noise of an infinite elastic plate, the noise reduction levels for various parameters such as the thickness of bubble layers, the volume fractions and the distribution types of bubbly fluids are calculated numerically. The noise reduction effect of an air bubble layer on an infinite flat plate is considerable level and similar to the tendency of dispersion of bubbly fluids. It is recommended that the thickness of a bubble layer should be increased with keeping an appropriate volume fraction of an air bubble for the most effective reduction of the radiation noise.

구조 인텐서티법을 이용한 에어컨 실외기의 제진재 적용 (Damping Patch Placement on Outdoor Unit of Air-conditioner by Using Structural Intensity Technique)

  • 김규식;진심원;정인화;이정우;강연준
    • 한국소음진동공학회논문집
    • /
    • 제14권7호
    • /
    • pp.577-585
    • /
    • 2004
  • In this paper, reactive shearing structural intensity method is extended to damping patches placement on outer panels of outdoor unit of air-conditioner to reduce its structural borne noise. The structural intensity is calculated from the normal velocities of structures that are measured by using a laser scanning vibrometer, and $textsc{k}$-space (wave-number domain) signal processing is used to obtain the spatial derivatives in formulation of structural intensity. This method is applied to the outdoor unit of air-conditioner on shaker-exciting mode and operating mode. and then damping patches are placed over area of high reactive shearing structural intensity for reducing the radiated noise. Experimental results show the largest reduction of sound pressure level of an outdoor unit by appling small damping patches to optimal position.

피치배열을 이용한 타이어 패턴노이즈 저감 (The reduction of Tire pattern noise by using pitch sequence)

  • 황성욱;방명제;김선주;조춘택
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.611-614
    • /
    • 2005
  • It is well known that tire tread pattern has much influence on the tire pattern noise. The paper describes the method of pattern noise reduction by using the pitch sequence, both on the smooth asphalt roads and on the trenched concrete roads. The noise of tire is classified as either airborne or structure borne noise. Pattern noise through the airborne is considered as a major noise source at high speeds. As block impacting and air pumping by tread patterns are major noise source, tire pattern noise can be greatly influenced by optimal pitch sequence. The goal of this paper is to provide tire engineers with pitch sequence to reduce pattern noise effectively.

  • PDF

실험적 방법을 이용한 고압증기 시스템의 방음설계 및 검증에 관한 연구 (A Study on Noise Control and Verification of High Pressure Steam System Using Experimental Method)

  • 석호일;이도경;정태석;허주호
    • 대한조선학회 특별논문집
    • /
    • 대한조선학회 2011년도 특별논문집
    • /
    • pp.112-116
    • /
    • 2011
  • The noise analysis is usually carried out in the early structure design stage for the main areas in a vessel such as an accommodation, an engine room, HVAC System and etc. If the analysis results are higher than the noise limits based on guideline, appropriate countermeasures are established to reduce noise levels and applied to the vessel. But excessive noise induced the main or auxiliary equipment and high pressure steam system is very difficult to check in the initial design stage, and local noise problems frequently appear in actual vessels. This paper deals with excessive noise of the engine control room on LNG carrier. It includes the cause analysis of excessive noise, the countermeasure, and verification. Also, it proves suitability of the countermeasure through the on-board test.

  • PDF

군용 궤도장비 보조동력장치의 소음저감 최적화 연구 (A Study on Optimization of Noise Reduction of Auxiliary Power Unit for Military Tracked Vehicle)

  • 이주승;김병호;김병현
    • 한국산학기술학회논문지
    • /
    • 제19권8호
    • /
    • pp.336-342
    • /
    • 2018
  • 군용으로 사용하는 궤도장비 디젤엔진의 보조동력장치에 대한 소음저감은 소요군의 감성품질을 만족시키는 중요한 요소 중 하나이다. 본 연구에서 이러한 보조동력장치의 소음을 줄이기 위해 구조기인소음을 저감하는 방법과 공기기인소음을 저감하는 방법을 고안하여 시험을 수행하였다. 그 결과 구조기인소음 저감을 위해 소음기를 개선하였을 때 약 22 dB(A)의 소음저감 효과가 있었다. 공기기인소음 저감의 영향을 알아보기 위해 흡음재의 종류와 후방문 그릴의 형상에 따른 소음을 측정하였고 그 영향은 인간이 인지하지 못하는 수준인 3 dB(A) 미만의 소음저감 효과가 나타났다. 또한, 실제차량에 소음저감을 위한 방안들을 적용하여 시험한 결과 구조기인소음을 저감하였을 때 약 9 dB(A)의 소음저감 효과가 나타났으며 공기기인소음의 저감효과는 1 dB(A) 이하로 측정된 것을 확인하였다. 따라서 궤도장비의 APU 소음저감을 위해서는 공기기인소음을 저감하는 방법보다 구조물을 통해 전달되는 소음을 저감하는 방안이 효과적이라는 것을 확인하였다. 본 연구결과를 통해 추후 개발하는 타 군용 궤도장비의 소음을 저감하기 위한 기초자료로 사용될 것으로 기대된다.

청감실험을 이용한 건축설비소음의 등급화 (Grading of Architectural Plumbing Noise using Psycho-Acoustic Experiment)

  • 유희종;정철운;김재수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.488-492
    • /
    • 2007
  • Since Equipment-Noises occurring in machine room penetrate wall-body and travel to the adjacent room in the form of air-borne sound and structure-borne sound, it is appearing as the main factor that injures a peaceful residential environment, and due to this, such noise-damage is currently increasing rapidly. Consequently, despite the measures for sound-insulation and soundproof against the equipment-noise penetrated wall-body is urgently required, but as the subjective evaluation considered for psychological response about the equipment-noise was not practiced, many dissatisfactions are still raising even after some measure was taken. On such point of view, this Research, at the spot, has actually measured the equipment-noise that had permeated various wall-bodies, and examined its physical characteristics, thence based upon this, has conducted Psycho-Acoustics Experiment and investigated the interrelation between the physical evaluation value and psychological reaction value. It is considered that such study result could be utilized as the useful material at the time of establishment of the Grading Standard for the insulation performance against the Architectural Plumbing Noise, in the future.

  • PDF