• Title/Summary/Keyword: Air-Shower

Search Result 36, Processing Time 0.024 seconds

A Classification of Clouds Observed in Korea (우리나라에서 관측된 구름의 분류)

  • So, Seun-Seup;Jeon, Sam-Jin
    • Journal of the Korean earth science society
    • /
    • v.18 no.6
    • /
    • pp.565-578
    • /
    • 1997
  • Clouds are usually formed by adiabatic cooling through ascending currents, radiation cooling or a mixture of warm air and cold one. Ascending currents are caused by covection currents, or they are accompanied with fronts. Thus clouds are formed through various kinds of causes and procedures. So they are various in height and shape. Form of clouds was classified on the basis of the thecriteria that L. Howard proposed in 1803. He distinguished three simple, fundamental classes-Cirrus, Cumulus, Stratus-from which the others were derived by trasition or association. And they are subdivided into 10 genera according to their height and shape. Most of the clouds are subdivided into the detailed kinds to the characteristics such as appearance or intensity of convection current. Sometimes completly different shape of cloud can be developed out of the 'mother-cloud'. In korea, the stratocumulus, altostratus and cirrus clouds frequently appear. Generally we are likely to have rain or snow from the stratus cloud forms(As, St, Sc) and rain shower or hail from the cumulus forms(Ac, Cu, Cb).

  • PDF

New Approach to the Care of Suction Drain Insertion Site by Using Occlusive Transparent Film Dressing (투명필름 밀폐 드레싱을 이용한 새로운 배액관 관리법)

  • Kwon, Soon Hong;Oh, Deuk Young;Choi, Youn Suk;Lee, Paik Kwon;Rhie, Jong Won;Han, Ki Taik;Ahn, Sang Tae
    • Archives of Plastic Surgery
    • /
    • v.33 no.1
    • /
    • pp.131-134
    • /
    • 2006
  • The closed suction drain is commonly inserted after various surgical procedures. It has an important role to prevent possible hematoma or seroma that can cause postoperative wound problems. But there is still no consensus on managing the insertion site of suction drain after operation. Suture-tie fixation of drain to skin and classical Y shape gauze dressing is a usually accepted method, but it has many limitations. We introduce a new approach to the care for the insertion site of suction drain by using occlusive transparent film dressing, $IV3000^{(R)}$(Smith & Nephew, London, UK). By using transparent film, insertion site of drain can be easily checked without removal of dressing. Because it can reduce the tension of suture-tie fixation, it helps to prevent skin injury. Furthermore, occlusive film dressing can block air leakage from insertion site of drain, and the water-proof character of film allows patients to take a shower without dressing change. This new method is more convenient, more efficient, and less harmful to skin than classic one.

On the Abnormal Low Temperature Phenomenon of the Yellow Sea Bottom Cold Water in Summer, 1981 (1981年 夏季 黃海底層冷水의 理想底水溫現象)

  • Yang, Sung-Ki;Cho, Kyu-Dae;Hong, Chol-Hoon
    • 한국해양학회지
    • /
    • v.19 no.2
    • /
    • pp.125-132
    • /
    • 1984
  • The abnormal low water temperature phenomenon of the Yellow Sea Bottom Cold Water in summer, 1981 is studied on the basis of the oceanographical data collected by the National Fisheries University of Pusan in July, 1981 and Fisheries Research and Development Agency of Korea from 1960 to 1981 and meteorological data within the same 22 years. In winter, 1980 the northwesterly monsoon was vary predominant and the air temperature was lower than that of mean year by 1∼8$^{\circ}C$ and also the surface temperature was lower 1∼3$^{\circ}C$. And then the temperature of the Yellow Sea Bottom Cold Water in summer, 1981 became lower 2∼3$^{\circ}C$ than that of mean year and the influence of this cold water was extended to about 50 miles off the coast of Cheju Island. Comparing with mean year, the water temperature at 30m depth in February, 1981 was lower by 1∼2$^{\circ}C$ in entire regions except near sea of Sohuksando and at 50m depth in August, 1981, it was lower by about 3.5$^{\circ}C$. Particularly, the offshore of Hongdo shower value of 5$^{\circ}C$ than that of mean year. It was found that the abnormal low water temperature phenomenon of Yellow Sea Bottom Cold Water in summer, 1981 resulted from the sea surface cooling by the predominant northwestly monsoon and abnormally low air temperature in winter, 1980.

  • PDF

A Study of Detainees' Perceptions of the Detention Facilities of the Police Station and their Operation (경찰서 유치장 시설 및 운영에 관한 유치인의 인식연구)

  • Jung, Woo-Yeoul;Park, Dong-Kyun;Kim, Do-Kyun
    • Korean Security Journal
    • /
    • no.13
    • /
    • pp.423-449
    • /
    • 2007
  • This research is to investigate the detention facilities of police stations and their real operations through the perceptions of detainees at police station cells and to present the policy suggestions for them. To fulfill the research, a questionnaire was made out on the basis of 'the Regulation on Detention and Escort for Suspects'. 'the Regulation on a Standard Plan for Detention Facilities' and 'the Regulation on the Lowest Standard to Treat Detainees' ; and detainees at 23 police station cells under the jurisdiction of Kyungbuk Local Police Agency were asked to answer it. Policy suggestions following from the result of the investigation of detainees' perceptions of the detention facilities of the police stations are as follows; Firstly, the structure of police station cells should be arranged in straight lines in order to take their human rights into consideration and more detention facilities are needed to be built in order to separate male, female, handicapped and juvenile inmates. Secondly, shower rooms and washrooms outside the cells should always be open to detainees whenever they need to be used. Thirdly, any detention facilities deficient in fire fighting equipment should have exit doors installed as soon as possible in case of an emergency and provide sufficient fire extinguishers considering the number of detainees and the size of the facilities. Fourthly, the detention facilities should have sufficient windows for ventilation and take necessary measures to obtain natural lighting instead of electric lighting. Fifthly, air conditioners should be equipped properly taking account of the number of detainees and the dimensions of the facilities. Policy suggestions according to the result of the investigation of detainees' perceptions of the operation of detention facilities of police stations are as follows; Firstly, the problem of operating the detention facilities must deal with worn-out facilities and measures to secure the budget should be taken as soon as possible. Secondly, considering that most detained suspects have difficulties in livelihood, daily necessaries must be issued to them. Thirdly, personal belongings deposited by inmates must be properly managed with the same documentation throughout the police station detention facilities. The number of female guards to take exclusive charge of the physical checkups and processing of female detainees should be increased. Also the facilities for handicapped detainees must be expanded, improved and managed properly. Fourthly, except for handcuffs and ropes to bind detainees in the detention facilities, helmets to prevent self-harm must be withdrawn. The budget to improve the quality of meal issued by the government must be urgently secured and the price of private food sent to detainees must be readjusted to be in line with the consumer price. Health and medical care and sanitation for detainees must be substantial, and also sunbathing and outdoor exercises should be allowed to detainees.

  • PDF

Cohort Observation of Blood Lead Concentration of Storage Battery Workers (축전지공장 근로자들의 혈중 연농도에 대한 코호트 관찰)

  • Kim, Chang-Yoon;Kim, Jung-Man;Han, Gu-Wung;Park, Jung-Han
    • Journal of Preventive Medicine and Public Health
    • /
    • v.23 no.3 s.31
    • /
    • pp.324-337
    • /
    • 1990
  • To assess the effectiveness of the interventions in working environment and personal hygiene for the occupational exposure to the lead, 156 workers (116 exposed subjects and 40 controls) of a newly established battery factory were examined for their blood lead concentration (Pb-B) in every 3 months up to 18 months. Air lead concentration (Pb-A) of the workplaces was also checked for 3 times in 6 months interval from August 1987. Environmental intervention included the local exhaust ventilation and vacuum cleaning of the floor. Intervention of the personal hygiene included the daily change of clothes, compulsory shower after work and hand washing before meal, prohibition of cigarette smoking and food consumption at the work site and wearing mask. Mean Pb-B of the controls was $21.97{\pm}3.36{\mu}g/dl$ at the preemployment examination and slightly increased to $22.75{\pm}3.38{\mu}g/dl$ after 6 months. Mean Pb-B of the workers who were employed before the factory was in operation (Group A) was $20.49{\pm}3.84{\mu}g/dl$ on employment and it was increased to $23.90{\pm}5.30{\mu}g/dl$ after 3 months (p<0.01). Pb-B was increased to $28.84{\pm}5.76{\mu}g/dl$ 6 months after the employment which was 1 month after the initiation of intervention program. It did not increase thereafter and ranged between $26.83{\mu}g/dl\;and\;28.28{\mu}g/dl$ in the subsequent 4 tests. Mean Pb-B of the workers who were employed after the factory had been in operation but before the intervention program was initiated (Group B) was $16.58{\pm}4/53{\mu}g/dl$ before the exposure and it was increased to $28.82{\pm}5.66{\mu}g/dl$(P<0.01) in 3 months later (1 month after the intervention). The values of subsequent 4 tests remained between 26.46 and $28.54{\mu}g/dl$. Mean Pb-B of the workers who were employed after intervention program had been started (Group C) was $19.45{\pm}3.44{\mu}g/dl$ at the preemployment examination and gradually increased to $22.70{\pm}4.55{\mu}g/dl$ after 3 months(P<0.01), $23.68{\pm}4.18{\mu}g/dl$ after 6 months, and $24.42{\pm}3.60{\mu}g/dl$ after 9 months. Work stations were classified into 4 parts according to Pb-A. The Pb-A of part I, the highest areas, were $0.365mg/m^3$, and after the intervention the levels were decreased to $0.216mg/m^3\;and\;0.208mg/m^3$ in follow-up tests. The Pb-A of part II was decreased from $0.232mg/m^3\;to\;0.148mg/m^3,\;and\;0.120mg/m^3$ after the intervention. Pb-A of part III and W was tested only after intervention and the Pb-A of part III were $0.124mg/m^3$ in Jannuary 1988 and $0.081mg/m^3$ in August 1988. The Pb-A of part IV not stationed at one place but moving around, was $0.110mg/m^3$ in August 1988. There was no consistent relationship between Pb-B and Pb-A. Pb-B of the group A and B workers in the part of the highest Pb-A were lower than those of the workers in the parts of lower Pb-A. Pb-B of the workers in the part of the lowest Pb-A incerased more rapidly. Pb-B of group C workers was the highest in part I and the lowest in part IV. These findings suggest that Pb-B is more valid method than Pb-A for monitoring the health of lead workers and intervention in personal hygiene is more effective than environmental intervention.

  • PDF

A cohort study on blood zinc protoporphyrin concentration of workers in storage battery factory (축전지 공장 근로자들의 혈중 Zinc Protoporphyrin에 대한 코호트 연구)

  • Jeon, Man-Joong;Lee, Joong-Jeong;SaKong, Joon;Kim, Chang-Yoon;Kim, Jung-Man;Chung, Jong-Hak
    • Journal of Preventive Medicine and Public Health
    • /
    • v.31 no.1 s.60
    • /
    • pp.112-126
    • /
    • 1998
  • To investigate the effectiveness of the interventions in working environment and personal hygiene for the occupational exposure to the lead, the blood zinc protoporphyrin (ZPP) concentrations of 131 workers (100 exposed subjects and 31 controls) of a newly established battery factory were analyzed. They were measured in every 3 months up to 18 months. Ai. lead concentration (Pb-A) of the workplaces was also checked for 3 times in 6 months interval from August 1987. Environmental intervention included the local exhaust ventilation and vacuum cleaning of the floor. Intervention of the personal hygiene included the daily change of clothes, compulsory shower after work and hand washing before meal, prohibition of cigarette smoking and food consumption at the work site and wearing mask. Mean blood ZPP concentration of the controls was $16.45{\pm}4.83{\mu}g/d\ell$ at the preemployment examination and slightly increased to $17.77{\pm}5.59{\mu}g/d\ell$ after 6 months. Mean blood ZPP concentration of the exposed subjects who were employed before the factory was in operation (Group A) was $17.36{\pm}5.20{\mu}g/d\ell$ on employment and it was increased to $23.00{\pm}13.06{\mu}g/d\ell$ after 3 months. The blood ZPP concentration was increased to $27.25{\pm}6.40{\mu}g/d\ell$ on 6 months (p<0.01) after the employment which was 1 month after the initiation of intervention program. It did not increase thereafter and ranged between $25.48{\mu}g/d\ell$ and $26.61{\mu}g/d\ell$ in the subsequent 4 results. Mean blood ZPP concentration of the exposed subjects who were employed after the factory had been in operation but before the intervention program was initiated (Group B) was $14.34{\pm}6.10{\mu}g/d\ell$ on employment and it was increased to $28.97{\pm}7.14{\mu}g/d\ell$ (p<0.01) in 3 months later(1 month after the intervention). The values of subsequent 4 tests were maintained between $26.96{\mu}g/d\ell$and $27.96{\mu}g/d\ell$. Mean blood ZPP concentration of the exposed subjects who were employed after intervention program had been started (Group C) was$21.34{\pm}5.25{\mu}g/d\ell$ on employment and it was gradually increased to $23.37{\pm}3.86{\mu}g/d\ell$ (p<0.01) after 3 months, $23.93{\pm}3.64{\mu}g/d\ell$ after 6 months, $25.50{\pm}3.01{\mu}g/d\ell$ after 9 months, and $25.50{\pm}3.10{\mu}g/d\ell$ after 12 months. Workplaces were classified into 4 parts according to Pb-A. The Pb-A of part I, the highest areas, were $0.365mg/m^3$, and after the intervention the levels were decreased to $0.216mg/m^3$ and$0.208mg/m^3$ in follow-up test. The Pb-A of part II which was resulted in lowe. value than part I was decreased from $0.232mg/m^3$ to $0.148mg/m^3$, and $0.120mg/m^3$ after the intervention. The Pb-A of part III was tested after the intervention and resulted in $0.124mg/m^3$ in January 1988 and $0.181mg/m^3$ in August 1988. The Pb-A of part IV was also tested after the intervention and resulted in $0.110mg/m^3$ in August 1988. There was no consistent relationship between Pb-A and blood ZPP concentration. The blood ZPP concentration of the group A and B workers in the part of the highest Pb-A were lower than those of the workers in the parts of lower Pb-A. The blood ZPP concentration of the workers in the part of the lowest Pb-A increased more rapidly. The blood ZPP concentration of the group C workers was the highest in part III. These findings suggest that the intervention in personal hygiene is more effective than environmental intervention, and it should be carried out from the first day of employment and to both the exposed subjects, blue color workers and the controls, white color workers.

  • PDF