• 제목/요약/키워드: Air-Conditioning system

검색결과 3,316건 처리시간 0.03초

2단 증기 압축식 냉동시스템을 적용한 해상용 제빙장치의 냉매에 따른 성능 분석 (Performance Analysis of a Seawater Ice Machine Applied Two-stage vapor compression refrigeration system for Various Refrigerants)

  • 윤정인;손창효;허성관;전민주;전태영
    • 동력기계공학회지
    • /
    • 제20권2호
    • /
    • pp.85-90
    • /
    • 2016
  • Coefficient of performance (COP) for two-stage compression system is investigated in this paper to develop seawater ice machine. The system performance is analyzed with respect to degrees of superheating and subcooling, condensing and evaporating temperatures, compression and mechanical efficiencies and mass flow ratio in an inter-cooler. The main results are summarized as follows : The COP of the system grows when the mass flow ratio, subcooling degree and evaporating temperature edge up. Contrariwise, the system performance descends in case that superheating degree and condensing temperature increase. The most effective factor for the COP is the mass flow rate ratio. Each refrigerant has different limitation for a value of the mass flow ratio in the inter-cooler because of difference in material property.

해양심층수 이용 냉방시스템에 관한 연구 (A Study on the Air Conditioning System by the Low Temperature Energy of the Deep Seawater)

  • 박성제;김효봉;김현주
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2006년 창립20주년기념 정기학술대회 및 국제워크샵
    • /
    • pp.253-256
    • /
    • 2006
  • This paper shows the study on application of the law temperature energy in the deep seawater. Deep, cold seawater has long been recognized as a valuable ocean energy resource. Recently, research and experimentation has been conducted on energy systems using deep seawater: deep seawater air conditioning system, ice-making device, salt and fresh-water manufacturing system and the Spray freeze drying system for extracting valuable material of the deep seawater. They are technically and economically feasible today: once installed, the energy is inexhaustible and there are no adverse environmental impacts. Because of the economy of scale in the air conditioning system, the seawater A/C system is most appropriate for supplying multiple buildings or hotels in a coastal area.

  • PDF

Study on the Performances of Air Flow Fate Effect on a Structured Packed Tower at Adiabatic Condition in a Liquid Lithium Chloride Cooling System

  • Bakhtiar, Agung;Choi, K.H.;Kim, J.R.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.404-408
    • /
    • 2009
  • The liquid desiccant air-conditioning system has been proposed as an alternative to the conventional vapor compression cooling systems to control air humidity. The complete system of liquid desiccant air-conditioning system is consisted two main components those are humidifier (regeneration) and dehumidifier. Humidifier part is connected to the load when summer season which is the air condition is hot and humid have to be turned into comfort condition on human. This paper purpose is performances study of air flow rate effect on a structured packed tower on cooling and dehumidifier system using liquid lithium chloride as the desiccant. Experimental apparatus used in this present study is consisted of three components those are load chamber, packed tower and chiller. Load chamber’s volume is $40m^3$, and packed tower dimension is cubic with length 0.4m occupied with packed column. Totally, 15 experimental has done using 5 times repeat on each variable of air velocity that varying on 2m/s, 3m/s and 4m/s with other conditions are controlled. Air inlet initial temperature and relative humidity are set respectively on $30^{\circ}C$ and 52%, desiccant flow rate is 0.63 kg/s, desiccant temperature is $10^{\circ}C$ and desiccant concentration is 0.4. The result of this study shows that averagely, the moisture removal rate and the heat transfer rate are influenced by the air velocity. Higher air velocity will increase the heat transfer and decreasing the moisture removal rate. At adiabatic condition the air velocity of 2 m/s respectively is having the higher moisture removal rate acceleration then the air velocity of 3m/s and 4 m/s until the steady state condition.

  • PDF

Electrical and Structural Design of Air-conditioning Fan Motor for Noise Reduction

  • Han Hyung-Suk;Mo Jin-Yong;Kim Chang-Hyun;Lee Jae-Kwon;Jeong Weui-Bong
    • Journal of Mechanical Science and Technology
    • /
    • 제20권10호
    • /
    • pp.1653-1661
    • /
    • 2006
  • AC induction motors have been widely used for fan motor of the air conditioner indoor unit. Noise of these AC induction motors is usually caused by the coupling effects of structural and electrical systems. The rotating torque and the noise from AC induction motor were discussed in this paper,. First, the modification of motor was carried out in order to reduce the unbalance magneto motive force between main and sub winding. Second, structural modification based on normal mode analysis and modal testing was carried out so that the fan motor does not have the natural frequencies near the 2f-line frequency. Numerical modifications through these two processes were verified by experiments, which showed that the sound pressure level at 2f-line frequency of the modified system became about 25dB less than that of conventional one.

중용량 공조에서 EHP와 GHP의 경제성 비교 (The Economic Comparison of EHP and GHP for Medium Capacity Air-conditioning)

  • 김영일
    • 설비공학논문집
    • /
    • 제20권3호
    • /
    • pp.167-174
    • /
    • 2008
  • Cost related to building equipment accounts for about 85% of the life cycle cost of buildings. Therefore proper selection of air-conditioning system is important for reducing the overall cost of buildings. In this study, medium capacity EHP and GHP for air-conditioning a building with a floor area of 1,200 $m^2$ are compared economically. To consider all the factors of initial and operation costs effectively, an annual equal payment method is proposed. For the initial cost, cost of equipment, construction, installation, electric facility, financial subsidy and tax cut is considered. Cost of basic electricity, energy(electricity and gas), space charge, labor, insurance and repair is considered for the operation cost. Under the assumptions made in this study, overall cost of EHP is less than that of GHP, but this is not absolute and different outcome may result if different assumptions are made. This study is useful for those who are interested in choosing an air-conditioning system that costs less for mid-size buildings with simple calculations.

저전력 무선센서 네트워크를 이용한 빌딩 내 환경공조 시스템 (Indoor Air-Conditioning System in building Using Lower Power Wireless Sensor Network)

  • 이승철;정완영
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2007년도 춘계종합학술대회
    • /
    • pp.397-400
    • /
    • 2007
  • 본 연구에서는 소형, 저전력 센서와 센서 인터페이스를 구현하여 빌딩내의 실내 공조시스템과 함께 연동하고자 하였다. 빌딩 내 공조시스템은 저비용인 저전력 무선센서 노드간의 네트워크를 형성하여 각 룸마다 오염농도를 분석하여 룸의 오염 상태를 확인 한 후 실내 공조시스템에 있는 팬을 자동으로 조절해서 최적의 환경을 조성할 수 있게 하였다. 또한 GUI 인터페이스를 통해 각 룸의 있는 센서노드의 배터리 상태를 확인할 수 있는 것은 물론 모니터링이 필요한 가스의 농도와 온도 등을 확인 할 수도 있었다. 본 논문에서는 IEEE 802.15.4와 Zigbee를 지원하는 근거리 통신망을 갖는 저전력 무선센서 노드를 이용하여 무선센서 네트워크를 형성하기 위해 Ad-hoc 기능을 갖는 Simple forwarding routing을 구현하였다. 그리고 가스센서의 전력소모를 줄이기 위해서 전기화학적으로 환원 또는 산화하여 외부회로에 흐르는 전류를 측정하는 저전력 전기화학식 가스센서를 사용하였으며, 가스센서 인터페이스를 저전력으로 동작하도록 설계하였다.

  • PDF

공기조화기내 메쉬삽입 물-공기 직접접촉의 열전달 특성 연구 (Air handling unit utilizing water/air direct contact heat exchanger with mesh)

  • 전용한;문명훈;김종윤;김남진;서태범;김종보
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1161-1166
    • /
    • 2008
  • The objective of this research was to investigate the enhancement of heat transfer by mesh in water/air direct contact air conditioning system. Mesh is inserted as a turbulent promoter in front of the water injection nozzle. The heat transfer characteristics with and without mesh and the effect of the number of inserted mesh and mesh porosity size have been studied experimentally. Inserted mesh improves heat transfer efficiency compared to non-inserted mesh system and heat transfer efficiency increased as the number of mesh is increased. Meanwhile, heat transfer efficiency decreased as the porosity of the mesh is increased. With inserted mesh, inlet and outlet temperature difference of air increased more than 50%. Heat exchange time of water/air to reach the 100% humidity decreased less than 30%. This result shows inserted mesh can enhance the performance of the water/air direct contact air conditioning system.

  • PDF

바닥취출 공조공간에서 급기온도 및 급기풍속이 환기효율에 미치는 영향 (Effect of supply air temperature and airflow rate on ventilation effectiveness in an underfloor air conditioning space)

  • 정광섭;한화택;홍승재
    • 설비공학논문집
    • /
    • 제10권5호
    • /
    • pp.640-648
    • /
    • 1998
  • A numerical study has been conducted to investigate the effect of inflow supply air temperature and velocity on ventilation effectiveness in an underfloor air conditioning space. A low Reynolds number k-$\varepsilon$ model is implemented to calculate steady state turbulent velocity distributions. A step-down injection method is used to calculate local and room mean ages from transient concentrations based on the concept of the age of air. Results show that there is a significant effect of Archimedes number on ventilation effectiveness especially for cooling conditions. Reynolds number shows relatively minor effect on velocity distribution and ventilation effectiveness especially for isothermal and heating conditions. It can be concluded that underfloor air conditioning system provides good ventilation characteristics for cooling conditions because of temperature stratification in the space.

  • PDF

HFC-134a를 대체냉매로 사용한 자동차 냉방시스템의 성능해석 (Performance Analysis of an Automotive Air Conditioning System Using HFC-134a as an Alternative Refrigerant)

  • 한도영;조영두
    • 설비공학논문집
    • /
    • 제7권3호
    • /
    • pp.406-420
    • /
    • 1995
  • As concerns increase over the dangers of environmental destruction on a global scale, CFC regulations have finally been carried out and some CFC's are expected to be phased out by the end of 1995. The research for alternative refrigerants is very demanding. The major activities related to alternative refrigerants are focused on two different areas; one is the development of mixed refrigerants by using the existing refrigerants, and the other is the development of new HFC refrigerants. One of the most promising alternative refrigerant for CFC-12 is HFC-134a. HFC-134a has often been used as a replacement of CFC-12 for automotive air-conditioners. However, due to different thermodynamic properties of HFC-134a, performances of the replaced system are degraded compared with those of the CFC-12 system. Sometimes, the complete redesign of the system is required. In order to analyse and design the new system effectively, the developement of a system simulation program, in which HFC-134a can be selected as a refrigerant, is recommended. Therefore, the summary of this research is as follows : (1) The various thermodynamic properties of HFC-134a are ana lysed and programmed. (2) The model for serpentine heat exchanger is developed and programmed. (3) These subroutines are integrated to develop to develop an automotive air conditioning system simulation program which is verified by the test results. (4) The verified program is used to analyse the performance of a selected automotive air conditioning system.

  • PDF