• 제목/요약/키워드: Air tubes

검색결과 495건 처리시간 0.025초

Fibrin Glue가 자연기흉의 재발에 미치는 영향 (The Effect of Fibrin Glue as a Prevention Against Spontaneous Pneumothorax)

  • 이석열
    • Journal of Chest Surgery
    • /
    • 제24권6호
    • /
    • pp.570-578
    • /
    • 1991
  • The spontaneous pneumothorax is the sudden collapse of the lung usually by air leakage from the ruptured sub-pleural bleb and has high recurrence rate. For prevention against recurrence, many drugs such as tetracycline, talcum powder, quinacrine, etc. have been used but the effects are not satisfactory. We reduced the recurrence rate successfully by the fibrin glue instillation through the chest tube. From the January 1989 to September 1990, we have managed 65 patients of spontaneous pneumothorax with closed thoracostomy and fibrin glue[fibrinogen 1gm/50ml with approtinin 3, 000kIU /ml, thrombin 5, 000IU /ml in 3% each 10ml] instillation through the chest tube. And we compared the results with those of 106 patients of spontaneous pneumothorax who were managed only by the closed thoracostomy from January 1985 to December 1988. Only the patients who visited our hospital with recurrence were considered as the recurred cases but the others were considered as not recurred. And the removal of chest tubes usually done 3 days after cessation of air leakage or 2 days after fibrin glue instillation Statistical analysis was done by X2-test. The results were as followings: 1. The recurrence rate of fibrin glue instillation group was lower than that of non-instillation group[1st attack: 15.1% versus 27.6% p<0, 05, the 2nd attack: 33.3% versus 73.7% p<0.01, the total 18.5% versus 35.8% p<0.01]. 2. The mean duration of chest tube drainage in the fibrin glue instillation group was shorter than non-instillation group[4.24$\pm$1.36 days versus 4.48$\pm$1.73 days p<0.05]. 3. The mean duration of hospitalization was shorter in the instillation group [8.12$\pm$3.5 days versus 10.8$\pm$3.8 days p<0.05] The complications were transient mild fever, chest pain, pleural effusion in 46 cases of 65 patients, but those didn`t make any problem. We concluded that the fibrin glue is effective in the reduction of recurrence rate, obliteration of air leakage and duration of hospitalization.

  • PDF

연소불안정 저감을 위한 다중 스월 인젝터의 음향학적 감쇠기능 (Effect of Multi-Swirl Injector on Acoustic Damping for Reduction of Combustion Instability)

  • 김현성;김병선;윤영빈
    • 한국항공우주학회지
    • /
    • 제36권1호
    • /
    • pp.62-71
    • /
    • 2008
  • 액체로켓엔진에서 발생하는 고주파 연소불안정을제어하기 위하여 인젝터의 길이 변화를 줄 수 있는 다중 스월 인젝터의 감쇠효과를 분석하였다. 음향흡수자로서 인젝터의 효과를 분석하기 위하여 인젝터는 1/4 파장 공명기로 해석하였고, 상온에서 감쇠 효과의 적합성을 검증하였다. 인젝터 내부에 형성되는 air core의 부피가 감쇠 효과에 직접적인 영향을 주므로 이를 모사한 다수의 튜브로 실험을 하였다. 실험을 통해 각 모드의 배(anti-node point)에 장착된 인젝터의 수의 증가로 감쇠 효과가 커지는 것을 확인하였다. 또한 1L, 1T, 1L1T 모드에 동조된 인젝터들을 동시에 각 모드의 배에 장착했을 경우, 각 모드에서 단일 모드에 튜닝된 인젝터들을 장착하였을 경우와 거의 같은 감쇠 효과를 얻을 수 있었다.

백필터 집진기의 지능형 IoT 탈진 시스템 개발 (Development of Intelligent IoT Exhaustion System for Bag Filter Collector)

  • 장성철;이정원
    • 사물인터넷융복합논문지
    • /
    • 제5권1호
    • /
    • pp.29-34
    • /
    • 2019
  • 백필터 집진기는 여러개 또는 수십개의 여과포를 구성하여 미세먼지를 정화시켜 깨끗한 공기를 대기에 방출시키는 일종의 공기청정기이다. 백필터 길이가 5m 이하인 경우 다이아프램 밸브에서 발생되는 압축공기를 벤추리를 통과시키는 것만으로도 백필터에 부착된 분진 및 흄을 효율적으로 탈진 할 수 있었다. 7m 이상의 롱백 탈진에 만족스러운 결과를 얻기 위해서는 더욱 효율이 높고 경제성 있는 인젝터 개발이 시급한 실정이다. 기존 국내외 인젝터의 경우 유지 보수시 다수의 블루튜브 해체작업과 인젝터와 블루튜브가 결합되어 중량증가로 인한 작업의 불편성 등 많은 문제를 내포하고 있는 실정이다. 본 연구에서는 코안다 효과를 이용한 최적의 인젝터 개발을 위한 유동해석과 4차 산업의 지능형 자동화 탈진 기술이 접목되어, 기존 설비 대비 에너지 비용저감 및 필터 수명향상 등을 획기적으로 개선시키고자 하는 상용화 연구를 수행하였다.

냉기 강제순환형 공랭식 쇼케이스 성능 해석 (Performance analysis of a cold-air forced circulation type showcase)

  • 김정식;김내현
    • 한국산학기술학회논문지
    • /
    • 제14권3호
    • /
    • pp.1003-1010
    • /
    • 2013
  • 본 연구에서는 식료품의 진열과 보관에 사용되며 전시효과가 우수한 냉기 강제순환식 쇼케이스의 성능을 예측하는 프로그램을 개발하였다. 압축기의 성능해석에는 제조사에서 제공한 성능선도를 사용하였고 모세관 내 압력손실은 균질유동 모델을 사용하여 계산하였다. 증발기와 응축기는 미소체적으로 구분하여 에너지 균형을 고려하였고 관내측과 공기측 열전달계수는 적절한 상관식으로부터 구하였다. 압축기로 3/4 마력급 왕복동식 2개를 사용하고, 팽창장치로는 내경 1.6 mm의 모세관을, 응축기와 증발기로는 상호 공유형태의 핀-튜브 열교환기를 적용한 쇼케이스 시제품에 대해 성능시험을 수행하고 시험결과와 비교했을 때, 본 프로그램은 시제품의 증발 온도와 응축 온도를 적절히 예측함을 확인하였다.

수증기댐 처리가 통죽(筒竹)의 송풍오븐건조 특성에 미치는 영향 (Effect of Vapor-dam Treatment on the Air Circulating oven Drying Characteristics of Bamboo Tubes)

  • 이남호;정희석;하야시 카즈오;;;황의도
    • Journal of the Korean Wood Science and Technology
    • /
    • 제35권1호
    • /
    • pp.11-16
    • /
    • 2007
  • 본 연구는 통죽의 송풍오븐 건조중 수증기댐 처리가 건조속도 및 할렬과 외주할 예방에 미치는 영향을 조사하였다. 생재에서 함수율 약 7~8%까지 건조되는데 소요되는 시간은 건조스케줄이 과격할수록 적었으며, 건조소요시간은 건조초기의 건조속도에 의해서 크게 좌우되는 것으로 나타났다. 건조중 횡단면적 수축율과 통피층의 두께수축율은 모두 비정상적일 정도로 매우 크게 나타났다. 무처리재의 경우 건조개시 직후 할렬과 외주할이 발생하였으며, 수증기댐 처리재에서는 약 67% 정도의 건조수율을 기대할 수 있었다. 수증기댐 처리재의 외주할은 건조조건 보다는 수증기댐 처리에 의한 횡단면을 통과하는 수분의 증발 차폐정도와 밀접한 관련이 있는 것으로 평가되었다.

SCR facility design for the selective catalyst performance of mixed gas

  • Woohyeon, Hwang;Kyung-Ok, Lee
    • 한국컴퓨터정보학회논문지
    • /
    • 제28권1호
    • /
    • pp.121-127
    • /
    • 2023
  • 본 연구에서는 질소화합물을 최적으로 줄일 수 있는 SCR에서 설계 조건과 CFD 해석 결과를 비교해 검토하고자 한다. 이를 위해 보일러의 쉘과 튜브 영역에 대해 설계 기준을 만족하고 있는지 CFD을 이용하여 해석하고 비교하였다. SCR 시스템에서 해석영역은 쉘 측은 가스·공기 열교환기 입구에서 출구까지이고, 튜브 측은 가스·공기 열교환기의 8개 튜브로 설정하였다. CFD 해석을 통해 SCR 시스템의 1차 촉매 면에서 가스의 속도 분포는 2.7%로 설계되었고, NH3/NOx 몰비 분포는 3.7%로 설계 기준을 만족하였다. 또한, 온도 분포의 균일성을 확인하였고 요구 조건인 260℃ 이상을 만족하였다. 촉매에 유입되는 가스의 각도는 2.9도로 설계 조건을 충족하였고, 그리고 발생하는 압력손실도 설계 요구조건을 만족하였다. 이러한 CFD 해석을 통해 각 영역별로 요구되는 설계조건을 만족하여 설계되어 최적으로 운전되고 있음을 확인하였다.

Development of Microfluidic Radioimmunoassay Platform for High-throughput Analysis with Reduced Radioactive Waste

  • Jin-Hee Kim;So-Young Lee;Seung-Kon Lee
    • 대한방사성의약품학회지
    • /
    • 제8권2호
    • /
    • pp.95-101
    • /
    • 2022
  • Microfluidic radioimmunoassay (RIA) platform called µ-RIA spends less reagent and shorter reaction time for the analysis compared to the conventional tube-based radioimmunoassay. This study reported the design of µ-RIA chips optimized for the gamma counter which could measure the small samples of radioactive materials automatically. Compared with the previous study, the µ-RIA chips developed in this study were designed to be compatible with conventional RIA test tubes. And, the automatic gamma counter could detect radioactivity from the 125I labeled anti-PSA attached to the chips. Effects of the multi-layer microchannels and two-phase flow in the µ-RIA chips were investigated in this study. The measured radioactivity from the 125I labeled anti-PSA was linearly proportional to the number of stacked chips, representing that the radioactivity in µ-RIA platform could be amplified by designing the chips with multi-layers. In addition, we designed µ-RIA chip to generate liquid-gas plug flow inside the microfluidic channel. The plug flow can promote binding of the biomolecules onto the microfluidic channel surface with recirculation in the liquid phase. The ratio of liquid slug and air slug length was 1 : 1 when the 125I labeled anti-PSA and the air were injected at 1 and 35 µL/min, respectively, exhibiting 1.6 times higher biomolecule attachment compared to the microfluidic chip without the air injection. This experimental result indicated that the biomolecular reaction was improved by generating liquid-gas slugs inside the microfluidic channel. In this study, we presented a novel µ-RIA chips that is compatible with the conventional gamma counter with automated sampler. Therefore, high-throughput radioimmunoassay can be carried out by the automatic measurement of radioactivity with reduced radiowaste generation. We expect the µ-RIA platform can successfully replace conventional tube-based radioimmunoassay in the future.

활성탄관법을 이용한 공기중 이황화탄소 농도 측정법에 관한 연구 (Evaluation of the Charcoal Tube Sampling Method for Carbon Disulfide in Air)

  • 이나루;백남원
    • 한국산업보건학회지
    • /
    • 제3권1호
    • /
    • pp.22-36
    • /
    • 1993
  • This study was conducted to evaluate the charcoal tube sampling method for carbon disulfide in the air. Breakthrough was investigated according to flow rate, sampling time and air volume. Also the storage stability by storage method and time was investigated. The results are summarized as follows. 1. The samples stored at room temperature($28.2^{\circ}C$), refrigerator($3.8^{\circ}C$) and freezer($-15.6^{\circ}C$) were analyzed every week to five weeks. At one week storage at room temperature, 3.5% of $CS_2$ in the front section of the charcoal tube migrated into the back section and 57.7% at five weeks. The amount of $CS_2$ in the back section of the charcoal increased continuously by storage time. Migration of $CS_2$ was slow at refrigerator, and stopped occur at freezer. Recovery rate $CS_2$ was 52-82% at room temperature and 92-101% at refrigerator, based on the amount at freezer as a reference value. Thus loss was observed at room temperature. 2. When 6-48 L of fresh air were passed through tubes with spiked amounts of 0.379 and 0.759mg sample, the amounts of $CS_2$ in the back section of charcoal were 5.7-132.4 and 0-92% of the amount in the front section, respectively. The total recovery rates of$CS_2$ from 0.379 and 0.759mg spiked sample were 35.7-101.0% and 9l.3-100.1%, respectively. $CS_2$ loss was observed in 0.379mg spiked sample, but not in 0.759mg spiked sample. In the spiked samples, the amount of $CS_2$ in the back section of charcoal was not affected by flow rate when the air volume was controlled. The amount of $CS_2$ in the back section of charcoal increased over sampling time. And the faster the flow rate, the more the migration amount when the sampling time was the same. 3. A known concentration, 10 ppm of $CS_2$, was produced in a 200 L Tedlar bag. When the air volume was 24, 36, 48 L, breakthrough was 5.8, 16.9, 47.4%, respectively. The sampling flow rate of 0.05, 0.1, 0.2 Lpm did not change the breakthrough rate. Breakthrough increased over sampling time. And the faster the flow rate, the more the breakthrough, when the sampling time was the same.

  • PDF

진주시 대기중 휘발성 유기화합물의 농도특성 기초조사 (Characterization of Volatile Organic Compounds(VOCs) Concentrations in Jinju)

  • 박정호;박현건;서정민
    • 한국환경과학회지
    • /
    • 제22권1호
    • /
    • pp.91-98
    • /
    • 2013
  • In order to study the seasonal patterns and possible origins of air concentrations of volatile organic compounds(VOC), measurements were taken with GC-MS at 3 sampling sites in Jinju for 12 months from Mar. 2010 to Feb. 2011. Atmospheric VOC are sampled on tubes containing solid adsorbents(Tenax TA) with a time resolution of 2hrs. Composition and concentration of VOC are analysed with a GC system equipped with thermal desorption apparatus(ATD). The most abundant compound appeared to be Toluene, Ethylbenzene and m,p-Xylene. The mean concentrations of Benzene were 0.20 ppb at GN site, 0.18 ppb at DA site, and 0.25 ppb at SP site, respectively. VOC concentration showed a strong seasonal variation, with higher concentrations during the spring and lower concentrations during the summer. The results showed that monthly fluctuations in measured VOC concentrations depended on variations in the strength of sources, as well as on photochemical activity and meteorological conditions. In Jinju, the total VOC emissions for 2009 were estimated to be 4,407 ton/year by Clean Air Policy Support System(CAPSS). It is shown that solvent use 57.5%(2,534 ton/yr), waste treatment and disposal 23.3%(1,025 ton/yr), and mobil source-road traffic 12.2%(537 ton/yr) are the most significant anthropogenic source.

포항과 구미의 대규모 산단지역 대기 중 휘발성 유기화합물 농도 분포 특성에 관한 연구 (Characterization of Atmospheric Concentrations of Volatile Organic Compounds in Industrial Areas of Pohang and Gumi Cities)

  • 백성옥;김수현;김미현
    • Environmental Analysis Health and Toxicology
    • /
    • 제20권2호
    • /
    • pp.167-178
    • /
    • 2005
  • This study was carried out to evaluate the temporal, spatial, and seasonal variations of VOC, and to characterize the VOC concentrations in two large industrial complexes located in Pohang and Gumi cities. Twenty -four hours continuous sampling of selected VOC was made with STS 25 sequential tube samplers and double-bed adsorbent tubes. Air samples were collected every three hour interval for 7 consecutive days in each site during summer and winter. VOC were determined by thermal desorption coupled with GC/MS. A total of 27 VOCs of environmental concern were determined, including aliphatic, aromatic and halides. Generally. concentrations of toxic VOC were higher in Gumi than Pohang, and VOC levels in industrial areas were typically several-fold higher than those in residential areas. The most abundant VOC appeared to be toluene for both cities. However, chlorinated VOC were higher in Gumi than Pohang, while aromatic VOC were more abundant in Pohang than in Gumi. Two cities showed relatively different variations of VOC concentrations within a day. It is likely that traffic related sources are major factors affecting the VOC in Pohang, and industrial solvents usages are important sources in Gumi. These results imply that the occurrence and levels of atmospheric VOC are strongly dependent on the type of industries in each city. Therefore, in order to develop any control strategies or to establish the priority rankings for VOC in large industrial complexes, the type of industries and the occurrence of VOC in the atmosphere should be taken into consideration.