Study on Performance Evaluation of Oscillating Heat Pipe Heat Exchanger for Low Temperature Waste Heat Recovery

  • Bui, Ngoc-Hung;Kim, Ju-Won;Jang, In-Seung;Kang, Jeong-Kil;Kim, Jong-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제11권2호
    • /
    • pp.73-81
    • /
    • 2003
  • The performance of heat exchanger using oscillating heat pipe (OHP) for low temperature waste heat recovery was evaluated. OHP used in this study was made from low finned copper tubes connected by many turns to become the closed loop of serpentine structure. The OHP heat exchanger was formed into shell and tube type. R-22 and R-141b were used as the working fluids of OHP with a fill ratio of 40 vol.%. Water was used as the working fluid of shell side. As the experimental parameters, the inlet temperature difference between heating and cooling water and the mass velocity of water were changed. The mass velocity of water was changed from 30 kg/$m^2$s to 92 kg/$m^2$s. The experimental results showed that the heat recovery rate linearly increased as the mass velocity and the inlet temperature difference of water increased. Finally, the performance of OHP heat exchanger was evaluated by $\varepsilon$-NTU method. It was found that the effectiveness would be 80% if NTU were about 1.5.

AN EXPERIMENTAL STUDY ON AIR-WATER COUNTERCURRENT FLOW LIMITATION IN THE UPPER PLENUM WITH A MULTI-HOLE PLATE

  • NO HEE CHEON;LEE KYUNG-WON;SONG CHUL-HWA
    • Nuclear Engineering and Technology
    • /
    • 제37권6호
    • /
    • pp.557-564
    • /
    • 2005
  • Air-water countercurrent flow limitation at perforated plates with four holes was investigated in a vertical tank to see the effects of the plate thickness, the number of hole, and the diameter of the hole on the onset of CCFL. The thickness of plates was 1 cm and 4 cm, with a relatively large hole diameter of 5 cm. The collapsed water level formed on the perforated plate and its distribution in the upper plenum were measured. The gas flow rate in the multi-hole plate is relatively higher than one in the single tube because some of holes in the multi-hole plate provide a flow path fur liquid with less air-liquid resistance than in the single tube. The onset of CCFL occurred at nearly the same air flow rate regardless of the plate thickness. The negligible effect of the plate thickness on CCFL means that the flooding is initiated at the top of the plate rather than at its bottom. It turns out that $j_k$ and $K_k$ better fit the data than $H_k$ when hole diameter is greater than 2.86 cm. In our experimental ranges, the collapsed water levels at the onset of CCFL ranged from 7.5 cm to 10.5 cm. There was no three dimensional distribution of water level before and after the onset of CCFL.

라돈방사능농도의 측정을 통한 지진발생 예측에 관한 연구 (A Study of the Prediction of Earthquake Occurrence by Detecting Radon Radioactivity)

  • 김윤신;이철민;이승일
    • 한국환경과학회지
    • /
    • 제12권6호
    • /
    • pp.677-688
    • /
    • 2003
  • The purpose of this study was to predict occurrence of earthquakes in Korea by measuring the concentration of radon radioactivity in the air and in the underground water. Two monitoring systems of radon concentration detection in the air were installed in Seoul, East Coast area, whereas of radon concentration in the underground water in Kyungju area during December, 1999 to June, 2001. The distribution of radon concentration in the air in Seoul is as follows Winter(10.10 $\pm$ 2.81 Bq/㎥), autumn(8.41 $\pm$ 1.35 Bq/㎥), summer(5.83 $\pm$ 0.05 Bq/㎥) and spring (5.34 $\pm$ 0.44 Bq/㎥), whereas the distribution of radon in the air in the East Coast area showed some difference as follows : autumn (14.08 $\pm$ 5.75 Bq/㎥), Summer (12.04 $\pm$ 0.53 Bq/㎥), Winter (12.02 $\pm$ 1.40 Bq/㎥) and spring (8.93 $\pm$ 0.91 Bq/㎥). In the meanwhile, the distribution of radon in the water is as follows : spring (123.59 $\pm$ 16.36count/10min), Winter (93.95 $\pm$ 79.69counter/10min), autumn (68.96 $\pm$ 37.53counter/10min) and spring (34.45 $\pm$ 9.69counter/10min). The daily range of the density of radon concentration in Seoul and East Coast area was between 5.51 Bq/㎥ - 9.44 Bq/㎥, 7.15 Bq/㎥ - 15.27 Bq/㎥, respectively. Correlation of the distributions of radon concentrations in the air and in underground water with earthquake showed considerable variations of radon concentration before the occurrence of the earthquake. The results suggested that radon radioactivity seemed to be helpful for the prediction of the occurrence of earthquake.

춘천의 안개발생과 관련된 기상특성분석 및 수치모의 (Analysis of Meteorological Features and Prediction Probability Associated with the Fog Occurrence at Chuncheon)

  • 이화운;이귀옥;백승주;김동혁
    • 한국대기환경학회지
    • /
    • 제21권3호
    • /
    • pp.303-313
    • /
    • 2005
  • In this study, meteorological characteristics concerning the occurrence of fog are analyzed using 4-years $(2000\~2003)$ data at Chuncheon and the probability of prediction is investigated. From the analysis of meteorological characteristics, the fog at Chuncheon occurred before sunrise time and disappeared after that time and lasted for $2\~4$ hours. When fog occurred, on the whole, wind direction was blew the northerly and wind speed was below 2.1m/s. Especially, about $42\%$ of foggy day fell on the calm $(0\~0.2\;ms^{-1})$ conditions. The difference between air temperature and dew point temperature near the surface were mainly less than $2^{\circ}C$. For the lack of water surface temperature, the water surface temperature was calculated by using Water Quality River Reservoir System (WQRRS) and then it was used as the surface boundary condition of MM5. The numerical experiment was carried out for 2 days from 1300 LST on 14 October 2003 to 1300 LST on 16 October 2003 and fog was simulated at dawn on 15 and 16 October 2003. Simulated air temperature and dew point temperature indicate the similar tendency to observation and the simulated difference between air temperature and dew point temperature has also the similar tendency within $2^{\circ}C$. Thus, the occurrence of fog is well simulated in the terms of the difference between air temperature and dew point temperature. Horizontal distribution of the difference between air temperature and dew point temperature from the numerical experiment indicates occurrence, dissipation and lasting time of fog at Chuncheon. In Chuncheon, there is close correlation between the frequency of fog day and outflow from Soyang reservoir and high frequency of occurrence due to the difference between air and cold outlet water temperature.

최속 강하법을 이용한 흡수식 냉동공조시스템 제어 (Control of the Absorption Air Conditioning System by Using Steepest Descent Method)

  • 한도영;김진
    • 설비공학논문집
    • /
    • 제15권6호
    • /
    • pp.495-501
    • /
    • 2003
  • Control algorithms for the absorption air conditioning system may be developed by using dynamic models of the system. The simplified effective dynamic models, which can predict the dynamic behaviors of the system, may help to develop effective control algorithms for the system. In this study, control algorithms for an absorption air conditioning system were developed by using a dynamic simulation program. A cooling water inlet temperature control algorithm, a chilled water outlet temperature control algorithm, and a supply air temperature control algorithm, were developed and analyzed. The steepest descent method was used as an optimal algorithm. The simulation results showed energy savings and the effective controls of an absorption air conditioning system.

The Optimal Control of an Absorption Air Conditioning System by Using the Steepest Descent Method

  • Han Doyoung;Kim Jin
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권3호
    • /
    • pp.123-130
    • /
    • 2004
  • Control algorithms for an absorption air conditioning system may be developed by using dynamic models of the system. The simplified effective dynamic models, which can predict the dynamic behaviors of the system, may help to develop effective control algorithms for the system. In this study, control algorithms for an absorption air conditioning system were developed by using a dynamic simulation program. A cooling water inlet temperature control algorithm, a chilled water outlet temperature control algorithm, and a supply air temperature control algorithm, were developed and analyzed. The steepest descent method was used as an optimal algorithm. Simulation results showed energy savings and the effective controls of an absorption air conditioning system.

프로세스 시뮬레이션에 의한 제 2종 흡수식 열펌프 성능에 관한 연구 (A Study on the Performance of an Absorption Heat Transformer with Process Simulation)

  • 조승연;김영인
    • 대한설비공학회지:설비저널
    • /
    • 제16권3호
    • /
    • pp.295-304
    • /
    • 1987
  • The purpose of this study is to develop a computer model for simulating the water-lit hium bromide absorption heat transformer (AHT) Including all major components and to find the flexibility in operation. The effect of source hot water temperature, cooling water temperature, useful hot water flow rate, cooling water flow rate and evaporator circulation flow rate were investigated. The coefficient of performance (COP), temperature boost $({\Delta}T\;=\;T_A\;-\;Ti)$ and concentration variations can be predicted. The performance study indicates that the performance of AHT increases for the waste hot water temperature increasing and with a decrease of the cooling water temperature. The effect on performances of useful hot water flow rape is significant except on temperature boost. Also the effects on performance of cooling water flow rate and evaporator circulation flow rate are small. It is shown that the computer program is valuable to predict the performance of absorp-tion heat transformer units at various working corditions.

  • PDF

한반도 연안 기온자료의 분포함수 추정 (Estimation on the Distribution Function for Coastal Air Temperature Data in Korean Coasts)

  • 정신택;조홍연;고동휘;황재동
    • 한국해안·해양공학회논문집
    • /
    • 제26권5호
    • /
    • pp.278-284
    • /
    • 2014
  • 연안 생태환경변화의 주요 지표로 이용되는 수온은 기온과 밀접한 상관관계가 있기 때문에 기온자료를 이용하여 기후변화에 따른 수온변화와 연안 생태환경변화를 추정할 수 있다. 기후변화는 기온 및 수온의 발생빈도 변화와 연안의 생태환경변화를 유발하기 때문에 기온과 수온의 발생 빈도분포 함수를 추정하는 연구가 필요하다. 본 연구에서는 우리나라 연안의 장기 기온자료를 이용하여 빈도분포함수를 추정하였다. 빈도분포 함수는 조위 분포함수 추정(Cho et al., 2003), 수온 분포함수 추정(Jeong et al., 2013) 등에 사용된 Bi-modal 형태의 분포함수를 이용 하였으며, 분포함수의 매개변수는 최소자승법으로 최적 추정하였다. 최적 추정된 매개변수는 기온자료의 기본적인 통계정보에 해당하는 평균, 표준편차, 왜도계수와 강한 상관관계를 보이고 있는 것으로 파악되었으며, 통계정보를 이용한 매개변수 추정공식의 RMS 오차는 5% 정도로 파악되었다. 한편 본 연구에서 제시하는 Bi-modal 분포함수는 전체적인 기온 분포양상을 적절하게 표현하고 있으나, 고온 영역의 급격한 빈도감소 양상 및 관측 자료의 분포에서 보이는 작은 첨두 재현에는 한계가 있는 것으로 파악되었다.

정수처리를 위한 여과지의 역세척에 관한 연구 (A Study on Backwashing of Granular Fiters Used in Water Treatment)

  • 이정택;안종호;최근호
    • 상하수도학회지
    • /
    • 제13권3호
    • /
    • pp.61-72
    • /
    • 1999
  • To obtain the experimental data for design and operation of actual filtration processes, a sand filter and three kinds of dual media filters in pilot-plant scale were operated in this study. We analyzed the effect of filter medium composition on the filter performance and the effects of backwash water flow rates, length of stream line and air flow rate on the filter backwash efficiency. We also compared the efficiencies of the combined air-water backwashing and the water backwashing in dual media filters. As the backwash water flow rates or the length of stream line increased, the final turbidity of backwash water was decreased and the filtration duration time after backwash was increased. In the case of the combined air-water backwashing, the backwash water quantity needed for backwashing the dual media filters could be decreased. The total volume of filtered water for the dual media filters during filter run was over three times larger than that for the sand filter. The dual media filters could be operated at a high filtration rate of 360 m/day.

  • PDF

중앙냉방시스템의 최적제어에 관한 연구 (Optimal Control for Central Cooling Systems)

  • 안병천
    • 설비공학논문집
    • /
    • 제12권4호
    • /
    • pp.354-362
    • /
    • 2000
  • Optimal supervisory control strategy for the set points of controlled variables in the central cooling system has been studied by computer simulation. A quadratic linear regression equation for predicting the total cooling system power in terms of the controlled and uncontrolled variables was developed using simulated data collected under different values of controlled and uncontrolled variables. The optimal set temperatures such as supply air temperature, chilled water temperature, and condenser water temperature, are determined such that energy consumption is minimized as uncontrolled variables, load, ambient wet bulb temperature, and sensible heat ratio, are changed. The chilled water loop pump and cooling tower fan speeds are controlled by the PID controller such that the supply air and condenser water set temperatures reach the set points designated by the optimal supervisory controller. The influences of the controlled variables on the total system and component power consumption was determined. It is possible to minimize total energy consumption by selecting the optimal set temperatures through the trade-off among the component powers. The total system power is minimized at lower supply, higher chilled water, and lower condenser water set temperature conditions.

  • PDF