• Title/Summary/Keyword: Air to water

Search Result 6,150, Processing Time 0.034 seconds

이유체노즐의 액체이송공기 공급방법에 따른 어뎁터 내부유동특성에 관한 해석적 연구 (Effects of Carrier Air Supplying Parameter on the Internal Flow Characteristics of an Adaptor in Two-Fluid Nozzle)

  • 박설혜;조민호;김덕진;이지근;노병준
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.65-70
    • /
    • 2008
  • The numerical simulation on the internal flow characteristics of the adaptor in a two-fluid nozzle has been performed to investigate the effects of carrier air supplying parameters using a commercial code. The four adaptor models with the different positions in the carrier air supplying port were considered at the fixed conditions of urea-water solution and carrier air supplying. As the results from the numerical analysis, the internal pressure of the adaptor was varied with the port position for carrier air supplying, and it shows lower pressure value than the atmospheric pressure. Consequently, the flowrate of urea-water solution issuing from the feeding injector with the adaptor varied up to 30% with the port positions for the carrier air supplying. When the carrier air is supplied from the side from the feeding injector axis and the upper part from the feeding injector tip, the flowrate of urea-water solution issuing from the feeding injector with the adaptor show higher value than other carrier air supplying conditions.

  • PDF

EXHAUST GAS HEAT RECOVERY SYSTEM FOR PLANT BED HEATING IN GREENHOUSE PRODUCTION

  • Kim, Y.J.;Ryou, Y.S.;Rhee, K.J.;Kang, G.C.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2000년도 THE THIRD INTERNATIONAL CONFERENCE ON AGRICULTURAL MACHINERY ENGINEERING. V.III
    • /
    • pp.639-646
    • /
    • 2000
  • Hot air heater with light oil combustion is the most common heater for greenhouse heating in the winter season in Korea. However, since the heat efficiency of the heater is about 80%, considerable unused heat in the form of exhaust gas heat discharges to atmosphere. In order to capture this exhaust gas heat a heat recovery system for plant bed heating in the greenhouse was built and tested in the hot air heating system of greenhouse. The system consists of a heat exchanger made of copper pipes, ${\phi}\;12.7{\times}0.7t$ located inside the rectangular column of $330{\times}330{\times}900mm$, a water circulation pump, circulation plastic pipe and a water tame The total heat exchanger area is $1.5m^2$, calculated considering the heat exchange amount between flue gas and water circulated in the copper pipes. The system was attached to the exhaust gas path. The heat recovery system was designed as to even recapture the latent heat of flue gas when exposing to low temperature water in the heat exchanger. According to performance test it can recover 45,200 to 51,000kJ/hr depending on the water circulation rates of 330 to $690{\ell}$/hr from the waste heat discharged. The exhaust gas temperature left from the heat exchanger dropped to $100^{circ}C$ from $270^{circ}C$ by the heat exchange between the water and the flue gas, while water gained the difference and temperature increased to $38^{circ}C$ from $21^{circ}C$ at the water flow rate of $690{\ell}$/hr. And, the condensed water amount varies from 16 to $43m{\ell}$ at the same water circulation rates. This condensing heat recovery system can reduce boiler fuel consumption amount in a day by 34% according to the feasibility study of the actual mimitomato greenhouse. No combustion load was observed in the hot air heater.

  • PDF

자연환기 온실의 환기회수에 따른 포그냉방시스템의 냉방효과 (The Cooling Effect of Fog Cooling System as Affected by Air Exchange Rate in Natural Ventilation Greenhouse)

  • 김문기;김기성;권혁진
    • 생물환경조절학회지
    • /
    • 제10권1호
    • /
    • pp.10-14
    • /
    • 2001
  • 포그냉방시스템의 냉방효과는 온실 내부의 상대습도, 공기유동과 밀접한 관계가 있다. 냉방설계용 VETH선도에서 냉발효율은 환기회수의 증가와 그에 상응하는 분무수량의 증가로 인하여 개선될 수 있다. 시간제어방식을 이용한 무차광 실험온실에서 분당 환기회수가 평균 0.77회, 분무수량이 2,009g 일 때 온실 내부의 기온이 31$^{\circ}C$로 외부기온과 거의 같게 나타났으며, 이 때의 증발효율은 82%이다. 분당 환기회수가 평균 0.26회, 분무수량이 1.256g인 경우 무냉방 온실의 기온과 비슷한 37.1$^{\circ}C$였다. 차광율 70%인 실험온실의 분당 환기환수가 평균 2.59회, 분무수량이 2,009g 일 때, 내부의 상대습도는 증가하나 기온은 하강하지 못했다. 그러나 분당 환기회수가 평균 2.33회, 분무수량이 2,009g인 경우 내부의 기온이 31.4$^{\circ}C$로 이 때 온실의 유입구 풍속은 최고 1.9m.s$^{-1}$였다. 시간제어의 경우 일정간격으로 일정한 수량을 분무하기 때문에 분무입자가 모두 증발하지 못하고 온실 내부에 누적되어 온실 내부의 상대습도를 증가시켜 냉방효율을 감소 시키는 원인이 되고 차광망이 온실내부의 공기흐름을 차단하여 증발효율을 감소시키는 것으로 나타났다. 포그냉방시스템의 냉방효율을 높이기 위해서는 온실 내부의 상대습도에 의한 제어방식과 내부 공기의 순환에 대한 연구가 필요하다.

  • PDF

생활 오배수를 이용한 중수처리 공급장치의 기술성 고찰 (Technical Considerations of Recycling Water Treatment/Supply Apparatus using Living Waste Water)

  • 조정식;이희완;김홍민
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.493-498
    • /
    • 2008
  • The several water resources are showed recently the various pollution types due to the industrialization and the disarranged district development. The living waste water, plant waste water and so are contaminated continuously and the recycling water is concerned highly to save the cost and to improve the environment as the general people. The dust and the heavy metal in the air and the acid rain are contaminating the river water and the underground water. The clean environment is on the rise to the general people and is to be the social problems. There is going to complement and repair the water supplying and fire extinguishing pipeline to save the construction cost and improve the environment in the construction facilities parts. Therefore, in this paper the recycling water treatment/supply apparatus using the living waste water is considerated technically and is raised on the practical uses.

  • PDF

A Study on Coolant Mixing in Multirod Bundle Subchannels

  • Cha, Jong-Hee;Cho, Moon-Haeng
    • Nuclear Engineering and Technology
    • /
    • 제2권1호
    • /
    • pp.19-25
    • /
    • 1970
  • 이 연구는 다봉속내에서의 인접유로간의 냉각재 혼합류를 실험적으로 다룬 것이다. 실험은 19봉속내의 사각형 유로와 삼각형 유로간의 혼합류를 단상 유동과 공기-물 이상 유동에 물질 전달량을 측정하여 얻고 있다. 실험결과는 단상 유동에서 낮은 혼합률을, 공기-물 이상 유동에서 큰 혼합률을 얻고 있으며 공기-물 유동에서의 혼합률은 공기 체적률의 증가에 따라 감소되고 있음을 나타내고 있다. 공기-물 이상 유동에서의 높은 혼합률은 공기류에 의한 충분한 교란효과 때문인 것 같다.

  • PDF

Air-Water 모델에서 기포특성에 관한 실험적 연구 (An Experimental Study on the Characteristics of Bubbles in Air-Water Model)

  • 오율권;서동표
    • 한국안전학회지
    • /
    • 제18권1호
    • /
    • pp.14-18
    • /
    • 2003
  • The structural development of air-water bubble plumes has been measured under different condition on air flow rate in a cylindrical bath. The time-averaged structure of plumes has been measured with an oscilloscope and an electro-conductivity probe. The temperature of bubbles was also obtained by a thermal-infrared camera. Gas volume fraction and bubble frequency were high since bubbles concentrated on the nozzle. In general, their axial and radial values tended to decrease with increasing distance. Bubble temperature reached water temperature within a short time. The present study showed that thermal equilibrium between bubbles and water was completed before bubbles flow became stable.

경사진 원형 수층에서의 자연대류 열전달 (Natural Convection Heat Transfer in Inclined Cylindrical Water Layers)

  • 장병훈
    • 설비공학논문집
    • /
    • 제15권10호
    • /
    • pp.787-794
    • /
    • 2003
  • The effect of inclination angle on natural convection heat transfer has been studied for water layers. The range of the Raleigh number was from the subcritical value to 1.4${\times}$10$^{7}$ , and the range of the inclination angle, $\theta$, measured from the horizontal was 0$\leq$$\theta$$\leq$180$^{\circ}$. For horizontal water layers, present results agreed well with the results of previous investigators and also showed significant departures from the results of air layers in the turbulent regime. Inclined cylindrical water layers showed secondary maxima in heat transfer, whereas rectangular air layers showed continuous decline of Nusselt number.

공기와 이산화탄소 가스에 수분공급을 위한 연구 (Water Vapor Supply Study for Air and Carbon dioxide)

  • 이택홍;박태성;김태완;노재현;강영진;이승용
    • 한국수소및신에너지학회논문집
    • /
    • 제25권1호
    • /
    • pp.72-78
    • /
    • 2014
  • The study has been designed to develop water vapor supply for semiconductor industry, industrial gas manufacturing, impurities analysis, and fuel cell. Water concentration in air reached $1019{\mu}mol/mol$ at dew temp ($-20^{\circ}C$) and water concentration in CO2 reached $127{\mu}mol/mol$ at dew temp ($-40^{\circ}C$. Carbon dioxide needs more wet gas than air because interaction potential of carbon dioxide shows more strong attraction than air.

바닥복사 난방시스템의 공급온수온도가 실내 열환경에 미치는 영향 (The Effects of Hot Water Supply Temperature on Indoor Thermal Characteristics for Floor Radiant Heating System)

  • 안병천
    • 한국지열·수열에너지학회논문집
    • /
    • 제14권4호
    • /
    • pp.13-19
    • /
    • 2018
  • The Effects of hot water supply temperature on indoor thermal characteristics for floor radiant heating system in residential apartment were researched by computer simulation. The parametric study on hot water supply temperatures with different outdoor air temperatures was done with regard to energy performance and control characteristics, respectively. As a result, the maximum overshoot of indoor air temperature and energy consumption were reduced by adjusting the hot water supply temperatures with outdoor air temperatures.

수중수색 시 수심에 따른 공기소모량의 변화 분석 (Analysis of changes in air consumption according to water depth in underwater search)

  • 전재인;공하성
    • 문화기술의 융합
    • /
    • 제6권1호
    • /
    • pp.433-439
    • /
    • 2020
  • 이 연구는 수심에 따른 공기소모량의 변화를 인간의 특성 및 이론값과의 비교·분석하였다. 실험 결과는 다음과 같다. 첫째, 실험대상자 A·B는 수심에 따라 각각 비슷한 상승률을 보였다. 둘째, 실험대상자 C는 수중 25m에서 공기소모량의 상승률이 유의하게 높게 나타났는데, 그 이유는 깊은 수심의 수압에 신체가 민감하게 반응하여, 호흡이 다른 참여자보다 다소 빨라 공기소모량을 증가시킨 것으로 보인다. 셋째, 실험대상자 D·E는 공기소모량이 전반적으로 유의하게 낮게 나타났다. 이는 D와 E의 연령이 각각 37세, 35세로 실험대상자 중 가장 젊고, 체력이 강건하며, 군 복무 당시 해상의 심해 잠수경험이 풍부하여 나타난 결과로 보인다. 넷째, 실험대상자 분당 평균 공기소모량은 수면과 비교하여 수중 5m는 약 1.45배, 수중 10m는 약 1.85배, 수중 20m는 약 2.8배로 분당 공기소모량이 증가하였다. 이는 구조대원 각자의 경험과 체력, 신체가 수중에서 적응하는 정도의 차이, 그리고 수중 호흡법이 달라서 나타난 결과로 보인다. 마지막으로 실험 평균값과 이론값의 차이는 실험대상자 구조대원 5명 각자의 경험과 체력, 신체가 수중에서 적응하는 정도의 차이 및 수중 호흡법에 따라 이론값보다 많거나 적게 공기를 소모하여서 나타난 결과로 보인다.