• Title/Summary/Keyword: Air to water

Search Result 6,142, Processing Time 0.045 seconds

Trade-off Analysis Between National Ecosystem Services Due to Long-term Land Cover Changes (장기간 토지피복 변화에 따른 국내 생태계서비스 간 상쇄효과(Trade-off) 분석)

  • Yoon-Sun Park;Young-Keun Song
    • Korean Journal of Environment and Ecology
    • /
    • v.38 no.2
    • /
    • pp.204-216
    • /
    • 2024
  • Understanding the trade-off effect in ecosystem services and measuring the interrelationships between services are crucial for managing limited environmental resources. Accordingly, in this study, we identified the dominant trends and increases and decreases in ecosystem services derived from changes in land cover over about 30 years and tracked changes in the relationships between ecosystem services that occurred over time. Through it, we determined the relationship between land cover changes and ecosystem service changes, as well as the distinct characteristics of service changes in different areas. The research primarily utilized the InVEST model, an ecosystem service assessment model. After standardizing the evaluation results between 0 and 1, it went through principal component analysis, a dimensionality reduction technique, to observe the time-series changes and understand the relationships between the services. According to the research results, the area of urbanized regions dramatically increased between 1989 and 2019, while forests showed a significant increase between 2009 and 2019. Between 1989 and 2019, the national ecosystem service supply witnessed a 13.9% decrease in water supply, a 10.5% decrease in nitrogen retention, a 2.6% increase in phosphorus retention, a 0.9% decrease in carbon storage, a 1.2% increase in air purification, and a 3.4% decrease in habitat quality. Over the past 30 years, South Korea experienced an increase in urbanized areas, a decrease in agricultural land, and an increase in forests, resulting in a trade-off effect between phosphorus retention and habitat quality. This study concluded that South Korea's environment management policies contribute to improving ecosystem quality, which has declined due to urbanization, and maximizing ecosystem services. These findings can help policymakers establish and implement forestry policies focusing on sustainable environmental conservation and ecosystem service provision.

Suggestions for improving data quality assurance and spatial representativeness of Cheorwon AAOS data (철원 자동농업기상관측자료의 품질보증 및 대표성 향상을 위한 제언)

  • Park, Juhan;Lee, Seung-Jae;Kang, Minseok;Kim, Joon;Yang, Ilkyu;Kim, Byeong-Guk;You, Keun-Gi
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.20 no.1
    • /
    • pp.47-56
    • /
    • 2018
  • Providing high-quality meteorological observation data at sites that represent actual farming environments is essential for useful agrometeorological services. The Automated Agricultural Observing System (AAOS) of the Korean Meteorological Administration, however, has been deployed on lawns rather than actual farm land. In this study, we show the inaccuracies that arise in AAOS data by analyzing temporal and vertical variation and by comparing them with data recorded by the National Center for AgroMeteorology (NCAM) tower that is located at an actual farming site near the AAOS tower. The analyzed data were gathered in August and October (before and after harvest time, respectively). Observed air temperature and water vapor pressure were lower at AAOS than at NCAM tower before and after harvest time. Observed reflected shortwave radiation tended to be higher at AAOS than at NCAM tower. Soil variables showed bigger differences than meteorological observation variables. In August, observed soil temperature was lower at NCAM tower than at AAOS with smaller diurnal changes due to irrigation. The soil moisture observed at NCAM tower continuously maintained its saturation state, while the one at AAOS showed a decreasing trend, following an increase after rainfall. The trend changed in October. Observed soil temperature at NCAM showed similar daily means with higher diurnal changes than at AAOS. The soil moisture observed at NCAM was continuously higher, but both AAOS and NCAM showed similar trends. The above results indicate that the data gathered at the AAOS are inaccurate, and that ground surface cover and farming activities evoke considerable differences within the respective meteorological and soil environments. We propose to shift the equipment from lawn areas to actual farming sites such as rice paddies, farms and orchards, so that the gathered data are representative of the actual agrometeorological observations.

Effects of Column Diameter on the Holdups of Bubble, Wake and Continuous Liquid Phase in Bubble Columns with Viscous Liquid Medium (점성액체 기포탑에서 탑의 직경이 기포, wake 및 연속액상 체류량에 미치는 영향)

  • Lim, Dae Ho;Jang, Ji Hwa;Kang, Yong;Jun, Ki Won
    • Korean Chemical Engineering Research
    • /
    • v.49 no.5
    • /
    • pp.582-587
    • /
    • 2011
  • Holdup characteristics of bubble, wake and continuous liquid phases were investigated in bubble columns with viscous liquid media. Effects of column diameter(0.051, 0.076, 0.102 and 0.152 m ID), gas velocity($U_G$=0.02~0.16 m/s) and liquid viscosity(${\mu}_L$=0.001~0.050 $Pa{\cdot}s$) of continuous liquid media on the holdups of bubble, wake and continuous liquid phases were discussed. The three phase such as bubble, wake and continuous liquid phases were classified successfully by adapting the dual electrical resistivity probe method. Compressed filtered air and water or aqueous solutions of CMC(Carboxy Methyl Cellulose) were used as a gas and a liquid phase, respectively. To detect the wake as well as bubble phases in the bubble column continuously, a data acquisition system(DT 2805 Lab Card) with personal computer was used. The analog signals obtained from the probe circuit were processed to produce the digital data, from which the wake phase was detected behind the multi-bubbles as well as single bubbles rising in the bubble columns. The holdup of bubble and wake phases decreased but that of continuous liquid media increased, with an increase in the column diameter or liquid viscosity. However, the holdup of bubble and wake phases increased but that of continuous media decreased with an increase in the gas velocity. The holdup ratio of wake to wake to bubble phase decreased with an increase in the column diameter or gas velocity, however, increased with an increase in the viscosity of con-tinuous liquid media. The holdups of bubble, wake and continuous liquid media could be correlated in terms of operating variables within this experimental conditions as: ${\varepsilon}_B=0.043D^{-0.18}U_G^{0.56}{\mu}_L^{-0.13}$, ${\varepsilon}_W=0.003D^{-0.85}U_G^{0.46}{\mu}_L^{-0.10}$, ${\varepsilon}_C=1.179D^{0.09}U_G^{-0.13}{\mu}_L^{0.04}$.

Evaluation of SharpIR Reconstruction Method in PET/CT (PET/CT 검사에서 SharpIR 재구성 방법의 평가)

  • Kim, Jung-Yul;Kang, Chun-Koo;Park, Hoon-Hee;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.12-16
    • /
    • 2012
  • Purpose : In conventional PET image reconstruction, iterative reconstruction methods such as OSEM (Ordered Subsets Expectation Maximization) have now generally replaced traditional analytic methods such as filtered back-projection. This includes improvements in components of the system model geometry, fully 3D scatter and low noise randoms estimates. SharpIR algorithm is to improve PET image contrast to noise by incorporating information about the PET detector response into the 3D iterative reconstruction algorithm. The aim of this study is evaluation of SharpIR reconstruction method in PET/CT. Materials and Methods: For the measurement of detector response for the spatial resolution, a capillary tube was filled with FDG and scanned at varying distances from the iso-center (5, 10, 15, 20 cm). To measure image quality for contrast recovery, the NEMA IEC body phantom (Data Spectrum Corporation, Hillsborough, NC) with diameters of 1, 13, 17 and 22 for simulating hot and 28 and 37 mm for simulating cold lesions. A solution of 5.4 kBq/mL of $^{18}F$-FDG in water was used as a radioactive background obtaining a lesion of background ratio of 4.0. Images were reconstructed with VUE point HD and VUE point HD using SharpIR reconstruction algorithm. For the clinical evaluation, a whole body FDG scan acquired and to demonstrate contrast recovery, ROIs were drawn on a metabolic hot spot and also on a uniform region of the liver. Images were reconstructed with function of varying iteration number (1~10). Results: The result of increases axial distance from iso-center, full width at half maximum (FWHM) is also increasing in VUE point HD reconstruction image. Even showed an increasing distances constant FWHM. VUE point HD with SharpIR than VUE point HD showed improves contrast recovery in phantom and clinical study. Conclusion: By incorporating more information about the detector system response, the SharpIR algorithm improves the accuracy of underlying model used in VUE point HD. SharpIR algorithm improve spatial resolution for a line source in air, and improves contrast recovery at equivalent noise levels in phantoms and clinical studies. Therefore, SharpIR algorithm can be applied as through a longitudinal study will be useful in clinical.

  • PDF

Acoustic Stratigraphy and Sedimentary Processes in the KONOD-1 Area between the Clarion and Clipperton Fracture Zones, Northeastern Equatorial Pacific (북동태펑양 크라리온-크리퍼톤 균열대 사이 한국 망간노듈개발지역-1의 탄성파층서 및 퇴적작용)

  • Jeong, Kap-Sik;Han, Sang-Joon;Kim, Seong-Ryul
    • 한국해양학회지
    • /
    • v.23 no.1
    • /
    • pp.24-40
    • /
    • 1988
  • In the Korea Ocean Nodule Development (KONOD)-1 area between the Clarion and Clipperton fracture zones of the northeastern equatorial Pacific, the pelagic sediment layer can be divided into two or three units on air-gun seismic profile. The acoustic units can be also correlated with those in the DSDP site 163 core. The topmost unit (unit I) is acoustically transparent and consists of zeolitic clay and radiolarian ooze of late Oligocene to middle Eocene age. Unit IIA is well-stratified and transparent in the lower part. consisting of the radiolarian ooze intercalated with chert beds and zeolitic clay of early Eocene to Paleocene age. Unit IIB is stratified with layers of silicified and compacted flinty-cherty nannofossil chalk (late Cretaceous) on top of the acoustic basement. Units I and IIA form the Line Islands Formation that overlies an unnamed formation of unit lIB. The entire layers and the unit I layer propressively thin northward, except near the Line Islands Ridge. The distribution of sediment layer has been controlled by the equatorial Cenozoic CCD and the northward spreading of the Pacific plate. The change of CCD corresponding to the subsidence and migration of the plate has determined the sediment composition of the DSDP 163 core passed across the equator of high sedimentation suite. The late Cretaceous sedimentary layer (unit IIB) in the 163 core was formed above the CCD south of the equator. The unit IIA resulted from rapid subsidence of the Pacific plate below the CCD in the Paleocene. The unit IIA is seen only in the west of 149 W. Both the units IIA and I were probably formed during the Pacific plate passing and after leaving the equatorial region respectively since early Eocene. In the south of the KONOD-l area, the unit I was redistributed by bottom current, a branch of the Antarctic Bottom Water flowing eastward guided by the Clipperton fracture zone. The activities of bottom currents were prolonged for a long geological time. Turbidite layers occur more than 350 km from the Hawaiian Ridge to near the Clarion fracture zone. They originated directly from the Hawaiian Ridge, filling the topographic lows.

  • PDF

Heavy Metals of Landfilled Biomass and Their Environmental Standard, Including CCA-treated Wood for Eco-housing Materials (방부처리 목재를 포함한 토양매립 바이오메스의 중금속 함량과 안전성 문제)

  • Lim, Kie-Pyo;Lee, Jong-Tak;Bum, Jung-Won
    • Journal of the Korean Wood Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.37-45
    • /
    • 2006
  • Recently, wood-framed houses has been built in the Korea for pension. Wood is good material for human healthy, while the construction lumbers are treated with preservative such as CCA (chromated copper arsenate), which contain some toxic elements for human body. However, if the waste woody biomass treated with various heavy metals, which has been collected from house construction or demolition, was fired in the field, and incinerated or landfilled after mass collection, such components will result in the toxic air pollutants in the burning or land fills, and spreaded into other areas. So the careful selection of wood and chemicals are required in advance for house construction, in particular, for environment-friendly housings. Therefore, this study was carried out to determine the content of toxic heavy metals in woody materials such as domestic hinoki and imported hemlock treated with CCA for housing materials, and the post-treated wood components such as organic fertilizer, sludge, dry-distilled charcoal and carbonized charcoal, to be returned finally into soil. The results are as follows. 1) The chemical analysis of toxic trace elements in various solid biomass required accurate control and management of laboratory environment, and reagents and water used, because of the error of data due to various foreign substances added in various processing and transporting steps. So a systematic analyzers was necessary to monitor the toxic pollutants of construction materials. 2) In particular, the biomass treated with industrial biological or thermal conditions such as sludge or charcoals was not fully dissolvable after third addition of $HNO_3$ and HF. 3) The natural woody materials such as organic fertilizer, sludge. and charcoals without any treatment of preservatives or heavy metal components were nontoxic in landfill because of the standard of organic fertilizers, even after thermal or biological treatments. 4) The CC A-treated wood for making the construction wood durable should not be landfilled, because of its higher contents of toxic metals than the criterion of organic fertilizer for agriculture or of natural environment. So the demolished waste should be treated separately from municipal wastes.

Measurement of Radiation Using Tissue Equivalent Phantom in ICR Treatment (자궁강내 근접방사선조사시 인체조직등가 팬톰을 이용한 방사선량 측정)

  • Jang, Hong-Seok;Suh, Tae-Suk;Yoon, Sei-Chul;Ryu, Mi-Ryeong;Bahk, Yong-Whee;Shinn, Kyung-Sub
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.1
    • /
    • pp.45-52
    • /
    • 1995
  • This study is to compare A point doses in human pelvic phantom by film dosimetry, computer planning and manual calculation by using of along-away table. We developed tissue equivalent human pelvic phantom composed of four pieces of cylindrical acryl tubes with water, to simulate intracavitary radiation (ICR) in patients with cervix cancer. When the phantom assembled from 4 pieces, it has a small space for inserting Fletcher-Suit-Delclos applicator like a human vagina. Fletcher-Suit-Delclos applicator inserted into the space was packed tightly with furacin gauzes, and three $^{137}Cs$ sources with radioactivity of $15.7mg\;Ra-eq$ were inserted into the tandem. For the film dosimetry, two pieces of X-OMAT V film (Kodak Co.) of which planes include point A, were arranged orthogonally in the slits between phantoms. A point dose and iso-dose curves were measured by means of optical densitometer. A point doses by film dosimetry, RTP system and manual calculation by using of along-away table were compared, and iso-dose curves by film dosimetry and computer planning were also compared. The dose of A point was 51.2cGy/hr by film dosimetry, 46.7cGy/hr by RTP system and 47.9 cGy/hr by along-away table. A point dose by computer planning was similar to the dose by calculation using of along-away table with acceptable accuracy $({\pm}3%)$, however, the dose by film dosimetry was different from two others with about 10% error. Since most clinical beams contains a scatter component of low energy photons, the correlation between optical density and dose becomes tenuous. In addition, film suffers from several potential errors such as changes in processing conditions, interfilm emulsion differences, and artifacts caused by air pockets adjacent to the film. For these reasons, absolute dosimetry with film is impractical, however, it is very useful for checking qualitative patterns of a radiation distribution. In future, solid state dosimeter such as TLD must be used for the dosimetry of ionizing radiation. When considerable care is used, precision of approximately 3% may be obtained using TLD.

  • PDF

Studies on the Morphological, Anatomical and Physiological Characters in Populus alba × glandulosa and its Parent (Populus alba × glandulosa 와 그의 양친종(両親種)의 형태(形態), 해부학(解剖學), 생리학적(生理学的) 연구(硏究))

  • Kim, Chung Suk;Chon, Sang Keun;Hwang, Jin Sung
    • Journal of Korean Society of Forest Science
    • /
    • v.49 no.1
    • /
    • pp.11-31
    • /
    • 1980
  • The morphological, anatomical and physiological traits were eximined for Populus alba ${\times}$ glandulosa which is an important planting species in Korea. The results obtained are as follows: 1. External characters in the leaf shape and chaff shape in the catkin were inherited as incomplete dominance but nectar gland was inherited as dominance. 2. Among the 15 selected clones, 9 clones were male, 2 clones female and 2 clones monoecious. 3. There were well-developed cork layers and bast fiber bundles in the bark. 4. Primordial leaves composed of 3 layers of cells and those undifferentiated into palisade and spongy parenchymas differed in its origin. 5. Leaf scare consisted of two kinds of tissues; one is connected to vascular bundle and the other not to vascular bundle. Tissues which had been connected to vascular bundle were isolated with only 2 or 3 layers of cork cells from the outside. 6. There was complicated arrangement in the vascular bundle of petioles. 7. Growth of the hybrid was sensitively influenced by external temperature, day-length and amount of light. In particular, it was apparent in height growth. 8. Flatness, loam soils and a $60{\times}60cm$ spacing might be best factors for the growth of P. alba ${\times}$ glandulosa. 9. The rooting of 15 clones was dependant upon external factors. 10. The growth of P. alba ${\times}$ glandulosa was best at around 80% of soil moisture content on the basis of plot water capacity. 11. Temperature difference between inside and outside stems below 100cm during the winter was the greatest at the south among seasons and among directions. 12. The sap movement was markedly influenced by air temperature, relative humidity in forest stand and moisture content in stem. 13. Total sugars in the cortex changed with season but did not differ in the dircetion of the stem. 14. Isoperoxidase variations in the leaf were different among 15 clones. Thus, it may be useful as a criterium for clonal identification. 15. The rate of soil moisture content decreased at a rapid slope was faster than that at a slow slope. Poor growth of P. alba ${\times}$ glandulosa at the slope was probably due to depletion of soil moisture.

  • PDF

Tephrostratigraphy and Paleoenvironments of Marine Core in the Kita-Yamato Trough, East Sea/Japan Sea (동해 키타-야마토 해곡에서 채취된 시추코아의 테프라층서와 고환경)

  • Chun Jong-Hwa;Cheong Daekyo;Han Sang-Joon;Huh Sik;Yoo Hai-Soo
    • Economic and Environmental Geology
    • /
    • v.39 no.1 s.176
    • /
    • pp.83-93
    • /
    • 2006
  • The Kita-Yamato Trough is characterized by a SW-NE trending narrow graben between the Yamato Bank and the Kita-Yamato Bank in the central East Sea/Japan Sea (ES/JS). Core 20EEZ-1 was obtained in the flat summit of a small ridge from the southwest Kita-Yamato Trough. The sedimentation was mainly controlled by the supply of hemipelgic sediments and substantial tephras from explosive volcanic eruptions of the Quaternary volcanoes. The aim of this study is to reconstruct the tephrostratigraphy from the marine sediments collected from the Kita-Yamato Trough and to provide the atmosphere and ocean conditions during the explosive volcanic eruptions. According to the detailed tephrostratigraphy and lithofacies records, the core sediments were deposited during the last marine isotope stage (MIS) 7. The core consists of four lithofacies, idetified as, oxidized mud (OM), crudely laminated mud (CLM) and bioturbated mud (BM), interbedded with coarse-grained tephra (TP). The major element geochemistry and stratigraphic positions of seven tephra layers suggest that they originated from the Aira caldera in Kyushu area among the Japanese islands (AT tephra; 29.24 ka), unknown submarine volcano in the south Korea Plateau (SKP-I; MIS 3, SKP-II; MIS 4, SKP-IV; boundary between MIS 6 and MIS 5e, SKP-V; MIS 6, respectively), and the Baegdusan volcano in the Korean Peninsula (B-KY1; ca. 130 ka, B-KY2; ca. 196 ka). The absence of tephras originated trom Ulleung Island in core 20EEZ-l suggest that the tephras had not been transported into the Kita-Yamato Trough by atmosphere conditions during the eruptions. On the other hand, the B-KYI and the B-KY2 tephras derived from the Baegdusan volcano were founded in the Kita-Yamato Trough by a presence of prevailing westerly winds during the eruptions. Furthermore, the SKP tephras were characterized by the transport across the air-water interface, causing quickly thrust of raising eruption plumes from subaqueous explosive eruptions. Surface currents may play an important role in controlling the distribution patterns of the SKP tephras to distal areas. The tephrostratigraphic study in the Kita-Yamato Trough provides the important chronostratigraphic marker horizons and the detailed atmosphere and ocean conditions during the explosive eruptions.

Standard Performance Measurements of GE $Advance^{TM}$ Positron Emission Tomography (GE $Advance^{TM}$ 양전자방출단층촬영기의 표준 성능평가)

  • Jeong, Ha-Kyu;Kim, Hee-Joung;Son, Hye-Kyung;Bong, Jung-Kyun;Jung, Hai-Jo;Jeon, Tae-Joo;Kim, Jae-Sam;Lee, Jong-Doo;Yoo, Hyung-Sik
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.2
    • /
    • pp.100-112
    • /
    • 2001
  • Purpose: The purpose of this study was to establish optimal imaging acquisition conditions for the GE $Advance^{TM}$ PET imaging system by performing the acceptance tests designed by National Electrical Manufacturers Association (NEMA) protocol and General Electric Medical Systems (GEMS) test procedures. Materials and Methods: Performance tests were carried out with $^{18}FDG$ radioactivity source and phantoms by using a standard acquisition mode. Transaxial resolution and scatter traction tests were performed with a line source and axial resolution with a point source, respectively. A cylindrical phantom made of polymethylmethacrylate (PMMA) was used to measure sensitivity, count rate losses and randoms, uniformity correction, and attenuation inserts were added to measure remaining tests. The test results were acquired in a diagnostic acquisition mode and analyzed mainly on high sensitivity mode. Results: Transaxial resolution and axial resolution were measured as average of 4.65 mm and 3.98 mm at 0 cm, and 6.02 mm and 6.71 mm at 20 cm on high sensitivity mode, respectively. Average scatter fraction was 9.87%, and sensitivity was $225.8kcps/{\mu}Ci/cc$ of trues. Activity at 50% deadtime was $4.6{\mu}Ci/cc$, and the error of count rate correction at that activity was from 1.49% to 3.83%. Average nonuniformity for total slice w3s 8.37%. The accuracy of scatter correction was -0.95%. The accuracies of attenuation correction were 5.68% for air, 0.04% for water and -6.51% for polytetrafluoroethylene (PTFE). Conclusion: The results satisfied most acceptance criteria, indicating that the GE $Advance^{TM}$ PET system can be optimally used for clinical applications.

  • PDF