• 제목/요약/키워드: Air supply & exhaust

검색결과 159건 처리시간 0.03초

격리병실내 급배기구 위치에 따른 오염물 제거효율 비교 (Comparison of pollutant removal efficiency according to the locations of the supply and exhaust)

  • 원안나
    • 도시과학
    • /
    • 제9권2호
    • /
    • pp.13-20
    • /
    • 2020
  • The Recently, several countries have been affected by respiratory diseases, resulting in renewed research interest in their prevention and control. One such example was the 2015 outbreak of Middle East Respiratory Syndrome (MERS) in South Korea and COVID-19. In this study, we performed experiments and simulations based on concentration decay using CO2 as the tracer gas to elucidate the pollutant-removal efficiency for different inlet and exhaust locations and outdoor air-supply ratios. The wall inlet exhibited a higher pollutant-removal efficiency, owing to the upward movement of the air from the lower zone to the upper one. In conclusion, it is recommended that a total air-conditioning plan for isolation rooms be established as well as efficient system operation for pollutant removal and air-flow control to prevent the transmission of infections from the patients to others.

디젤기관의 LPG 혼합에 의한 오염배출물 저감특성 (Emission characteristics of diesel engine by mixing LPG)

  • 장영준;전충환;이춘우
    • 오토저널
    • /
    • 제15권2호
    • /
    • pp.44-52
    • /
    • 1993
  • In this study, the characteristics of decreasing exhaust gas of diesel engine was examined in dual fuel method by using commertial LPG for automotive. LPG was supplied to engine intake port by fumigation method and flow rate was controlled by using the needle valve. LPG supply ratios were 0, 20, 30% of total fuel amount to be supplied to engine by mass base. We investigated the effect of LPG supply ratio on exhaust gas concentrations related to excess air ratio and engine load at 1600, 1800, 2000 rpm. Soot concentration decreased about 30% in proportion to the increase of the LPG supply ratio. NOx concentration decreased in proportion to the increase of the LPG than diesel only and the increase rate was higher at low engine load. BSFC(Brake specific fuel consumption) was lower in proportion to the increase of the LPG supply ratio at high engine load and to the decrease of LPG supply ratio at low engine load.

  • PDF

고공시험설비의 전체 사양을 결정하는 시험부를 중심으로 설비개발시의 주요 고려사항 (Fundamental design consideration for optimum performance in altitude test cell facility)

  • 최경호;이중형;조지오위노;이대수
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년도 제31회 추계학술대회논문집
    • /
    • pp.411-415
    • /
    • 2008
  • 이 논문은 고도모사 시험설비의 전체 사양을 결정에 관계되는 엔진 입구에서의 고도비행 경험을 위한 모의대기 요구 조건, 모의 비행중 쇼요되는 연료 소모량 및 공급 방법, 시험모드별 냉각부하 예측, 효과적인 압력 회복률을 위한 배기 이젝터의 최적형상 결정에 관한 고려사항을 기술하였다. 이를 위하여 엔진의 연료소모량을 고려한 엔진 배기가스의 온도 및 배출량 등의 계산을 수행되었다.

  • PDF

대심도 지하역사 승강장 및 대합실 평상시/비상시 급·배기 풍량에 대한 실험적 연구 (Experimental Study for the Capacity of Ordinary and Emergency Ventilation System in Deeply Underground Subway Station)

  • 장용준;이호석;박덕신
    • 한국철도학회논문집
    • /
    • 제15권6호
    • /
    • pp.579-587
    • /
    • 2012
  • 서울 지하철 지하역사의 평상시 및 비상시(화재시)의 급배기 효율을 조사하기 위하여 대표적인 대심도역사인 신금호 역사를 선정하여 설계 용량 대비 실제 용량을 계측하여 비교분석 하였다. 신금호 역사는 심도가 43.6m(서울에서 3번째 깊이) 이며, 지하8층의 섬식 승강장과 지하 1,2층의 대합실로 이루어져 있다. 승강장과 대합실을 연결하는 통로는 1개의 비상계단을 사용하도록 되어있다. 실험을 위하여 열선유속계, capture hood, 풍향풍속계 및 데이터 수집장치 등을 이용하여 자동 계측하였다. 실험 결과 평상시 대합실에서는 급기량 및 배기량이 설계치에 비하여 실측치가 각각 34% 및 46% 감소된 환기량을 보였으며, 승강장에서는 급기량 및 배기량이 각각 66% 및 38% 감소된 환기량을 보였다. 비상시에서는 대합실에서 급기량이 42% 감소, 승강장에서는 배기량이 28% 감소된 것으로 조사되었다. 따라서 평상시에는 역사에서의 공기질 악화 및 비상시에는 제연능력 약화가 예상된다.

백연 저감을 위한 열교환 시스템의 배기 열전달 특성에 관한 연구 (Study on Exhaust Air Heat Transfer Characteristics of Heat Exchange System for White Smoke Reduction)

  • 왕쩐후안;전종균;권영철
    • 한국기계기술학회지
    • /
    • 제20권6호
    • /
    • pp.739-744
    • /
    • 2018
  • In this study, effects of reducing white smoke at a heat exchange system for white smoke reduction were studied in the winter season. For this purpose, the heat transfer processes on the exhaust air were investigated by Solidworks. Five wave heat exchangers of air-to-air and air-to-water type were applied for the exhaust air heat recovery. The analytical condition of the exhaust air was fixed and the computational analysis was performed according to the change of SA(supply air) inlet velocities. In order to evaluate the performance of the heat exchange system for white smoke reduction, W(water)/SA recovered capacities and the temperature/absolute humidity reduction rate were calculated. As SA inlet velocity increased, the exit temperature and absolute humidity of the mixing zone were reduced by up to about $40^{\circ}C$ and 0.12kg/kg respectively. Also, W/SA recovered capacities increased linearly up to about 35%.

유공성 수평격판을 가진 열원이 있는 밀폐공간내의 온도분포 특성 (Characteristices of Temperature Distribution in a Closed Space with Heat Source and Porous Horizontal Partition)

  • 박찬수;조대환;전철균
    • 한국해양공학회지
    • /
    • 제13권3B호
    • /
    • pp.29-37
    • /
    • 1999
  • Ventilation of the marine engine room is very important for the health of the workers as well as the normal operation of machines. To find proper ventilation conditions of this engine room, numerical simulation with standard k-${\epsilon}$ model was carried out. In the present study, the marine engine room is separated to two floors with porus horizontal partition and considered as a closed space with a heat source and forced ventilation ducts. The porosity of horizontal partition is found to be important. For the engine room with 2 supply ports & 2 exhaust ports, the increasing of the porosity of horizontal partition is effective to reduce the recirculation flow zone in the second floor. When the engine room is ventilated with three supply air ports & one exhaust port, the increasing of the porosity of horizontal partition is effective to reduce the recirculating flow zone in the exhaust air area, but there is a possibility of local extreme heating at the lower side of engine near bottom.

  • PDF

오염발생원의 위치인식에 의한 환기장치 제어방안 (Ventilation System Control by Location-Aware of Pollution Source)

  • 한화택;한정일;권용일
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.405-410
    • /
    • 2006
  • This paper presents a control algorithm of supply and exhaust diffusers by recognizing a contaminant source location. CFD analysis has been conducted to calculate steady state airflow and concentration distributions in a model room, which has two supply and two exhaust openings on the ceiling. Calculations have been performed for five cases out of nine different ventilation modes by combining on/off control of the supply and exhaust openings. Local mean residual life times are obtained and compared at 9 internal points for each ventilation case. Depending on the contaminant source location, the ventilation system is operated at an optimum ventilation mode, which can results in maximum exhaust performance.

  • PDF

실내 공기질 개선을 위한 환기기술에 관한 연구 (A Study on the ventilation Technology for Indoor Air Quality Improvement)

  • 장태현;조현욱
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권5호
    • /
    • pp.540-551
    • /
    • 2005
  • In this research, We'll focus on warm environment and ventilation characteristics when utilizing intake ports, exhaust port and 4-way cassettes for removing heat and polluted air. Four way cassettes have been typical air conditioning units for offices since the multi air-conditioner was introduced. The following installation cases will also be discussed: 1) 4-way cassette's operation without intake ports and exhaust port. 2) Effect of the position of intake port and exhaust ports. 3) cooling air flow, temperature. distribution and local supply index according to the air flow rate from 4-way cassettes.

열회수장치에 의한 열교환 성능 분석(농업시설) (Analysis of Heat Exchanging Performance of Heat Recovering Device Attached to Exhaust Gas Duct)

  • 서원명;강종국;윤용철;김정섭
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2000년도 학술발표회 발표논문집
    • /
    • pp.333-339
    • /
    • 2000
  • This study was performed to investigate the performance of heat recovery device attached to exhaust gas funnel connected to combustion chamber of greenhouse heating system. The experiment heat recovery system is mainly consisted of LPG combustion chamber and two heat recovery units; unit-A is attached directly to the exhaust gas funnel, and unit-B is connected with unit-A. Heat recovery performance was evaluated by estimating total energy amount by using enthalpy difference between two measurement points together with mass flow rate of gas and/or air passing through each heat recovery unit depending on 5 different flow rates controlled by voltage meter. The results of this experimental study, such as heat exchange behavior of supply air pipes and exhaust air passages crossing the pipes, pressure drop between inlet and outlet, heat recovery performance of exchange unit, etc., will be used as fundamental data for designing optimum heat recovery device to be used for fuel saving purpose by reducing heat loss amounts mostly wasted outside of greenhouse through funnels.

  • PDF