• 제목/요약/키워드: Air quality system

검색결과 1,306건 처리시간 0.034초

중국 초미세먼지 현황 및 정책 동향 (Review on the Current Status and Policy on PM2.5 in China)

  • 문광주;채혁기;전권호;;;김대곤;박현주;김정수
    • 한국대기환경학회지
    • /
    • 제34권3호
    • /
    • pp.373-392
    • /
    • 2018
  • The emission of air pollutants in China has increased rapidly as its economy expanded over the last decades. The Chinese government has recently acknowledged the seriousness of the resulting air pollution and is trying to improve air quality in many ways. Here, we review the air quality control and management policies in China, one of our closest neighbors, because these policies may also influence the air quality in Korea. This study examined the recent policies on $PM_{2.5}$ reduction and analyzed the variation in air quality and air pollutant emissions in China. The ambient air quality and emission standards in China have been strengthened, based on China's Air Pollution Prevention and Control Action Plan of 2013. As a result, the annual mean concentration of $PM_{2.5}$ in 2015 in 74 large Chinese cities declined by 23.6% compared with 2013 values. Coal consumption in China also has been reduced by more than 10% per year since 2013. Furthermore, the laws controlling atmospheric emissions were revised again in 2016, and an air pollution forecasting and warning system was implemented to help manage air pollution problems. At present, the Chinese government is trying to evaluate its policies on $PM_{2.5}$ and find a new paradigm to mitigate ongoing $PM_{2.5}$ pollution. In this context, a joint study between Korea and China has been initiated to investigate the characteristics and sources of ambient $PM_{2.5}$ and to identify factors contributing to the high $PM_{2.5}$ concentrations in northeast China. We expect that this academic collaboration will benefit both countries in their search for new policies for $PM_{2.5}$ reduction.

부하변동에 대한 바이패스 공조시스템의 특성 (The Characteristics of a Bypass Air Conditioning System for Load Variation)

  • 김보철;신현준;김정엽
    • 설비공학논문집
    • /
    • 제14권3호
    • /
    • pp.240-246
    • /
    • 2002
  • Bypass air conditioning systems are divided into three types; an outdoor air bypass, a mixed air bypass and a return air bypass system. What makes the return air by pass system more effective is that it directs all of moist outdoor air through the cooling coil. The bypass air conditioning system can maintain indoor R.H (Relative Humidity) less than a conventional CAV (Constant Air Volume) air conditioning system by adjusting face and bypass dampers at part load. When a design sensible load (the ratio of sensible load to total sensible load) is 70 percent (at this time, RSHF (Room Sensible Heat Factor) . 0.7), indoor R.H was maintained 59 percent by the return air bypass system, but 65 percent by the conventional CAV air conditioning system (valve control system). The bypass air conditioning system can also improve IAQ (Indoor Air Quality) in many buildings where the number of air change is high.

수도권 지역의 대기환경관리 시행계획 추진결과 평가를 위한 대기질 모델링 적용 방법 (Methodology of Application to Air Quality Model to Evaluate the Results of the Enforcement Plan in Seoul Metropolitan Area)

  • 유철;이대균;이용미;이미향;홍지형;이석조
    • 한국환경과학회지
    • /
    • 제20권12호
    • /
    • pp.1647-1661
    • /
    • 2011
  • The Government had devised legislation of Special Act and drew up guidelines for improving air quality in Seoul Metropolitan area. In 2007 local government of Seoul, Incheon and Gyeonggi conducted the results of application policy by reduced air pollutants emission for the first time. Although there was reduction of air pollutant emission in each local government, it was ineffective as expected using air pollution monitoring database. Therefore we worked out a way to prepare modeling input data using the results of enforcement plan. And we simulated surface $NO_2$ and PM10 before and after decrease in air pollutants emission and examine reduction effects of air pollution according to enforcement regulation except other influence, by using MM5-SMOKE-CMAQ system. Each local government calculated the amount of emission reduction under application policy, and we developed to prepare input data so as to apply to SMOKE system using emission reduction of enforcement plan. Distribution factor of emission reduction were classified into detailed source and fuel codes using code mapping method in order to allocate the decreased emission. The code mapping method also included a way to allocate spatial distribution by CAPSS distribution. According to predicted result using the reduction of NOx emission, $NO_2$ concentration was decreased from 19.1 ppb to 18.0 ppb in Seoul. In Gyeonggi and Incheon $NO^2$ concentrations were down to 0.65 ppb and 0.68 ppb after application of enforcement plan. PM10 concentration was reduced from 18.2 ${\mu}g/m^3$ to 17.5 ${\mu}g/m^3$ in Seoul. In Gyeonggi PM10 concentration was down to 0.51 ${\mu}g/m^3$ and in Incheon PM10 concentration was decreased about 0.47 ${\mu}g/m^3$ which was the lower concentration than any other cities.

전동차의 실내 공기청정도 측정 평가 (The Measurement of the Indoor Air Quality in Subway)

  • 소진섭;유성연;윤차중;김완종;강성해;박덕신;조영민;권순박;박은영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1325-1329
    • /
    • 2007
  • Indoor air quality is an important determinant of human health and comfort. However, the complexity of pollution sources and the multitude of parties responsible for creating indoor exposures makes the improvement of air quality difficult. The HVAC(Heating, Ventilating and Air-Conditioning) system is important facility to provide comfortable environment passenger service. The Ministry of Environment is established "Indoor Air Quality Management guidelines in Public Facilities"in December 2006. Hereupon, the train and the subway are included. In this research air quality in the Subway compartment has been measured. As a result, the concentrations of PM10 and $CO_2$ were reached to 93% and 61% of the regulation values, respectively. Thus, the indoor air qualities of subway have been proved that they satisfy the recommended guidelines by the Ministry of Environment.

  • PDF

서울시 아파트 가격에 대한 대기질의 영향 - 헤도닉 가격기법을 이용하여 - (An Effect of Air Quality on the Apartment Prices in Seoul: Using Hedonic Price Method)

  • 최종일;심성훈
    • 자원ㆍ환경경제연구
    • /
    • 제11권2호
    • /
    • pp.261-278
    • /
    • 2002
  • Based on the hedonic pricing method, this paper investigates the effect of air quality on the apartment price in Seoul. The empirical results show that both the structural variables such as years of construction, heating system, and size of apartment complex and accessability variables such as distances to subway station and parks provide statistically significant effects on the price of apartment, Especially, the dendity of sulfurous acid gas ($SO_2$) and ozone ($O_3$) in the air, indicating air quality, negatively affect the price of apartment, This implies that as the condition of air quality to become worse, apartment price decreases, Therefore, when the degree of aversion of apartment residents against the air pollution affects the formation of apartment's market price, the MWPT(Marginal Willingness to Pay) in order to improve the air quality 10% has been estimated as 36,000~39,000Won per month.

  • PDF

대기오염 측정 자료에 의한 지방도시의 대기환경규제지역 설정에 관한 타당성 검토 (Investigation on the Validation for Designating Air Quality Control Region among Provincial Cities by the Data Measured with Air Quality Monitoring Network)

  • 유미선;양성봉;우경빈
    • 한국환경과학회지
    • /
    • 제25권1호
    • /
    • pp.181-190
    • /
    • 2016
  • Regional air quality regulation is a system that allows the Minister of Environment to designate the local area as air quality control region where the concentrations of air pollutants are exceeding the environmental standards, and the local governments that administrate the regulated area have to develop and practise a plan for reducing the air pollutants. From the data observed yearly by the monitoring stations in 8 provincial cities with more than 0.5 million people was judged the compliance with air quality standards in each municipality for the period of 2003 to 2013. As the result of investigation on air pollutants concentrations of each city, it was found that there was no station that exceeds the ambient air quality standards of CO, $SO_2$ and 24-hour $NO_2$. But all municipalities exceeded the standards of 8-hour $O_3$, annual and 24-hour $PM_{10}$, and therefore 8 municipalities can be designated to be under the local air regulation. For the annual $NO_2$ were the monitoring sites necessary requirements for designation of the air quality regulation region in Cheongju, Cheonan, Daejeon and Gwangju area. Incase of 1-hour $O_3$, some of stations in Pohang, Cheongju, Cheonan and Changwon area were over the designation standards for the air quality control region.

지하주거의 실내공기환경 실태조사와 CO2 조절기 및 타이머에 의한 환기팬 자동운전에 관한 연구 (A Study on the Actual Conditions of Indoor Air Quality of Underground Dwellings and the Automatic Ventilating Fan Operated by CO2 Controller and Timer)

  • 권영철;박진철
    • KIEAE Journal
    • /
    • 제8권4호
    • /
    • pp.3-9
    • /
    • 2008
  • The rapid urbanization after 1970s caused the shortage of dwellings in urban areas. As the result, the underground dwellings were developed to compensate for the insufficient dwelling spaces. While the underground dwellings have some advantage in the respect of thermal and acoustic environment, they usually have the basic problems in the indoor air quality because of the lack of natural ventilation through small window areas. The purpose of this study is to investigate and to improve the indoor air quality of underground dwellings. Thirty Units in Seoul and Gyung-Gi Province were investigated into the indoor environmental conditions. For the purpose of the improvement of their indoor air quality, Automatically-operated ventilating fan was installed in a sample unit which has worst indoor environmental condition. Then the indoor air quality was monitored when it was operated by $CO_2$ control system and timer. Finally economic feasibility study was made considering the effect of the improvement of indoor air quality. The extra cost for installing timer could be paid back only in 10 months, so timer-installed automatic fan is recommended to improve the indoor air quality of underground dwellings.

Development of IoT based Real-Time Complex Sensor Board for Managing Air Quality in Buildings

  • Park, Taejoon;Cha, Jaesang
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제10권4호
    • /
    • pp.75-82
    • /
    • 2018
  • Efforts to reduce damages from micro dust and harmful gases in life have been led by national or local governments, and information on air quality has been provided along with real-time weather forecast through TV and internet. It is not enough to provide information on the individual indoor space consumed. So in this paper, we propose a IoT-based Real-Time Air Quality Sensing Board Corresponding Fine Particle for Air Quality Management in Buildings. Proposed board is easy to install and can be placed in the right place. In the proposed board, the air quality (level of pollution level) in the indoor space (inside the building) is easy and it is possible to recognize the changed indoor air pollution situation and provide countermeasures. According to the advantages of proposed system, it is possible to provide useful information by linking information about the overall indoor space where at least one representative point is located. In this paper, we compare the performance of the proposed board with the existing air quality measurement equipment.

환경보건학적 관점에서 본 메르스 사태의 문제점 - 병원 실내공기질 관리를 중심으로 - (Problems of the Middle East Respiratory Syndrome Outbreak from the Perspective of Environmental Health - Focusing on Control of Indoor Air Quality in Hospitals -)

  • 허다안;이정현;허은혜;문경환
    • 한국환경보건학회지
    • /
    • 제41권3호
    • /
    • pp.216-221
    • /
    • 2015
  • Since Patient Zero of MERS was diagnosed in May 20, 2015, cases of MERS continued to grow. The current situation, which people have been confirmed to be infected, suggested that contaminated indoor air could be the potential cause of hospital-acquired infections. It is important to address the indoor air quality in hospitals because pathogens can spread through air. While the heating, ventilating and air conditioning(HVAC) system is useful managing indoor air quality in hospitals, it can transmit the pathogens if operated improperly. Therefore, it is necessary to remove contaminants in hospitals and operate the HVAC system according to the guidelines, in order to maintain clean indoor air.

아파트주택에 있어서 실내공기청정기에 의한 환기의 수치해석 (A Numerical Analysis on Forced Ventilation using Indoor Air Cleaner in an Apartment House)

  • 고재윤;김일겸;최병훈;임장순
    • 설비공학논문집
    • /
    • 제13권3호
    • /
    • pp.217-223
    • /
    • 2001
  • There exist a number of approaches which can evaluate ventilation and indoor air quality. The measurement and analysis of indoor carbon dioxide concentrations can be useful for evaluating indoor air quality and ventilation. This paper describes a numerical analysis of carbon dioxide concentrations for evaluating indoor air quality and ventilation and the factors the need to be considered in their use. The conditions of this numerical analysis are tow types of positions and inlet velocities of ventilation system in a two-dimensional model of an apartment house. The simulation results could be used as a base data for further analysis for ventilation design of other industrial processes producing a proper ventilation system for a healthier and more comfortable environment in a building.

  • PDF